Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Ref : ACR.262.4.2.MVGB.A SHENZHEN STS TEST SERVICES CO., LTD. 1/F., BUILDING 2, ZHUOKE SCIENCE PARK,No.190, CHONGQING ROAD,FUYONG STREET, BAO’ AN DISTRICT, SHENZHEN,GUANGDONG,CHINA MVG COMOSAR REFERENCE DIPOLE FREQUENCY: 750 MHZ SERIAL NO.: SN 30/14 DIP0G750-331 SAR Reference Dipole Calibration Report Calibrated at MVG Z.I. de la pointe du diable Technopôle Brest Iroise - 295 avenue Alexis de Rochon 29280 PLOUZANE - FRANCE Calibration date: Summary: Page: 1/11 3 07/04/2023 Accreditations #2-6789 and #2-6814 Scope available on www.cofrac.fr This document presents the method and results from an accredited SAR reference dipole calibration performed in MVG using the COMOSAR test bench. All calibration results are traceable to national metrology institutions. SAR REFERENCE DIPOLE CALIBRATION REPORT Ref: ACR.262.4.2.MVGB.A Customer Name Distribution : Shenzhen STS Test Services Co., Ltd. Name Function Date Signature Prepared by : Jérôme LUC Technical Manager 7/0 /202 Checked by : Jérôme LUC Technical Manager Approved by : Yann Toutain Laboratory Director Issue Date Modifications A Initial release Name Jérôme LUC Page: 2/11 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 3 4 7/0 /202 3 4 7/0 /202 3 4 7/0 /202 3 4 3 SAR REFERENCE DIPOLE CALIBRATION REPORT TABLE OF CONTENTS 1 Introduction ................................................................................................................ 4 2 Device Under Test ..................................................................................................... 4 3 Product Description ................................................................................................... 4 3.1 General Information _______________________________________________________ 4 4 Measurement Method ................................................................................................ 5 4.1 Return Loss Requirements __________________________________________________ 5 4.2 Mechanical Requirements ___________________________________________________ 5 5 Measurement Uncertainty .......................................................................................... 5 5.1 Return Loss ______________________________________________________________ 5 5.2 Dimension Measurement ___________________________________________________ 5 5.3 Validation Measurement ____________________________________________________ 5 6 Calibration Measurement Results .............................................................................. 6 6.1 Return Loss and Impedance In Head Liquid ____________________________________ 6 6.2 Return Loss and Impedance In Body Liquid ____________________________________ 6 6.3 Mechanical Dimensions ____________________________________________________ 6 7 Validation measurement ............................................................................................ 7 7.1 Head Liquid Measurement __________________________________________________ 7 7.2 SAR Measurement Result With Head Liquid ____________________________________ 8 7.3 Body Liquid Measurement __________________________________________________ 9 7.4 SAR Measurement Result With Body Liquid __________________________________ 10 8 List of Equipment .................................................................................................... 11 Page: 3/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 1 INTRODUCTION This document contains a summary of the requirements set forth by the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards for reference dipoles used for SAR measurement system validations and the measurements that were performed to verify that the product complies with the fore mentioned standards. 2 DEVICE UNDER TEST Device Under Test Device Type COMOSAR 750 MHz REFERENCE DIPOLE Manufacturer MVG Model SID750 Serial Number SN 30/14 DIP0G750-331 Product Condition (new / used) Used A yearly calibration interval is recommended. 3 PRODUCT DESCRIPTION 3.1 GENERAL INFORMATION MVG’s COMOSAR Validation Dipoles are built in accordance to the IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards. The product is designed for use with the COMOSAR test bench only. Figure 1 – MVG COMOSAR Validation Dipole Page: 4/11 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH Ref: ACR.262.4.2.MVGB.A 3 SAR REFERENCE DIPOLE CALIBRATION REPORT 4 MEASUREMENT METHOD The IEEE 1528, OET 65 Bulletin C and CEI/IEC 62209 standards provide requirements for reference dipoles used for system validation measurements. The following measurements were performed to verify that the product complies with the fore mentioned standards. 4.1 RETURN LOSS REQUIREMENTS The dipole used for SAR system validation measurements and checks must have a return loss of -20 dB or better. The return loss measurement shall be performed against a liquid filled flat phantom, with the phantom constucted as outlined in the fore mentioned standards. 4.2 MECHANICAL REQUIREMENTS The IEEE Std. 1528 and CEI/IEC 62209 standards specify the mechanical components and dimensions of the validation dipoles, with the dimensions frequency and phantom…
Text truncated - open the document above for the full version.
Page 1 of 2 FCC ID: 2BSW8-WAVE10 Setup photo AC Conduction RF Conduction Page 2 of 2 FCC ID: 2BSW8-WAVE10 RE (30 MHz-1GHz) RE (1-18GHz) RE (Above 18GHz)
SARSetupphotosforFCCID:2BSW8-WAVE10 RightTouch RightTilt LeftTouch LeftTilt LimbsFrontside(separationdistanceis0mm) LimbsBackside(separationdistanceis0mm) LimbsLeftside(separationdistanceis0mm) LimbsRightside(separationdistanceis0mm) LimbsBottomside(separationdistanceis0mm) LimbsTopside(separationdistanceis0mm) BodyFrontside(separationdistanceis10mm) BodyBackside(separationdistanceis10mm) BodyLeftside(separationdistanceis10mm) BodyRightside(separationdistanceis10mm) BodyBottomside(separationdistanceis10mm) BodyTopside(separationdistanceis10mm)
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2601248W07 Issued for HONG KONG LELEGAO TECHNOLOGY CO.,LIMITED 19H Maxgrand Plaza, No.3 Tai Yau Street, San Po Kong, Kowloon, HongKong, China Product Name: 4G Smart phone Brand Name: Blackview Model Name: WAVE 10 Series Model(s): N/A FCC ID: 2BSW8-WAVE10 Test Standards: FCC Part15.247 Page 2 of 85 Report No.: STS2601248W07 TEST REPORT Applicant’s Name ................. : HONG KONG LELEGAO TECHNOLOGY CO.,LIMITED Address ................................. : 19H Maxgrand Plaza, No.3 Tai Yau Street, San Po Kong, Kowloon, HongKong, China Manufacturer's Name ........... : Shenzhen Doke Electronic Co., LTD Address ................................. : 801, Building3, 7th Industrial Zone, Yulv Community, Yutang Road, Guangming District, Shenzhen, China Product Description Product Name ........................ : 4G Smart phone Brand Name ........................... : Blackview Model Name .......................... : .. : WAVE 10 Series Model(s) .................... : N/A Test Standards ..................... : FCC Part 15.247 Test Procedure........................: ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ...................... : 23 Jan. 2026 Date (s) of performance of tests ............. : 23 Jan. 2026 ~ 15 Feb. 2026 Date of Issue .......................................... : 25 Feb. 2026 Test Result .............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 85 Report No.: STS2601248W07 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 RADIATED EMISSION MEASUREMENT 17 4. DUTY CYCLE 35 4.1 TEST STANDARD 35 4.2 TEST PROCEDURE 35 4.3 DEVIATION FROM STANDARD 35 4.4 TEST SETUP 35 4.6 TEST RESULTS 35 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 36 5.1 LIMIT 36 5.2 TEST PROCEDURE 36 5.3 DEVIATION FROM STANDARD 36 5.4 TEST SETUP 36 5.5 EUT OPERATION CONDITIONS 36 5.6 TEST RESULTS 36 6. POWER SPECTRAL DENSITY TEST 37 6.1 LIMIT 37 6.2 TEST PROCEDURE 37 6.3 DEVIATION FROM STANDARD 37 6.4 TEST SETUP 37 6.5 EUT OPERATION CONDITIONS 37 6.6 TEST RESULTS 37 Page 4 of 85 Report No.: STS2601248W07 Table of Contents Page 7. BANDWIDTH TEST 38 6.1 LIMIT 38 7.2 TEST PROCEDURE 38 7.3 DEVIATION FROM STANDARD 38 7.4 TEST SETUP 38 7.5 EUT OPERATION CONDITIONS 38 7.6 TEST RESULTS 38 8. PEAK OUTPUT POWER TEST 39 8.1 LIMIT 39 8.2 TEST PROCEDURE 39 8.3 DEVIATION FROM STANDARD 39 8.4 TEST SETUP 39 8.5 EUT OPERATION CONDITIONS 39 8.6 TEST RESULTS 39 9. ANTENNA REQUIREMENT 40 9.1 STANDARD REQUIREMENT 40 9.2 EUT ANTENNA 40 APPENDIX 1-TEST DATA 41 DUTY CYCLE 41 MAXIMUM PEAK CONDUCTED OUTPUT POWER 48 -6DB BANDWIDTH 49 MAXIMUM POWER SPECTRAL DENSITY LEVEL 56 BAND EDGE 63 CONDUCTED RF SPURIOUS EMISSION 72 Page 5 of 85 Report No.: STS2601248W07 Revision History Rev. Issue Date Report No. Effect Page Contents 00 25 Feb. 2026 STS2601248W07 ALL Initial Issue Page 6 of 85 Report No.: STS2601248W07 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 85 Report No.: STS2601248W07 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.751dB 2 Unwanted Emissions, conducted ±2.888dB 3 All emissions, radiated 9K-30MHz ±2.48dB 4 All emissions, radiated 30M-1GHz ±2.52dB 5 All emissions, radiated 1G-18GHz ±3.48dB 6 All emissions, radiated>18GHz ±4.18dB 7 Conducted Emission (9KHz-150KHz) ±2.48dB 8 Conducted Emission (150KHz-30MHz) ±2.52dB 9 Occupied Channel Bandwidth ±3.6% 10 Power Spectral Density, conducted ±1.214dB 11 Duty Cycle ±3.2% Page 8 of 85 Report No.: STS2601248W07 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name 4G Smart phone Brand Name Blackview Model Name WAVE 10 Series Model(s) N/A Model Difference N/A Product Des…
Text truncated - open the document above for the full version.
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2601248W06 Issued for HONG KONG LELEGAO TECHNOLOGY CO.,LIMITED 19H Maxgrand Plaza, No.3 Tai Yau Street, San Po Kong, Kowloon, HongKong, China Product Name: 4G Smart phone Brand Name: Blackview Model Name: WAVE 10 Series Model(s): N/A FCC ID: 2BSW8-WAVE10 Test Standards: FCC Part15.247 Page 2 of 77 Report No.: STS2601248W06 TEST REPORT Applicant’s Name ................. : HONG KONG LELEGAO TECHNOLOGY CO.,LIMITED Address ................................. : 19H Maxgrand Plaza, No.3 Tai Yau Street, San Po Kong, Kowloon, HongKong, China Manufacturer's Name .......... : Shenzhen Doke Electronic Co., LTD Address ................................. : 801, Building3, 7th Industrial Zone, Yulv Community, Yutang Road, Guangming District, Shenzhen, China Product Description Product Name ....................... : 4G Smart phone Brand Name .......................... : Blackview Model Name .......................... : ... : WAVE 10 Series Model(s) .................... : N/A Test Standards ..................... : FCC Part15.247 Test Procedure ...................... : ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the IC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ..................... : 23 Jan. 2026 Date (s) of performance of tests ............. : 23 Jan. 2026 ~ 15 Feb. 2026 Date of Issue .......................................... : 25 Feb. 2026 Test Result.............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 77 Report No.: STS2601248W06 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.6 EQUIPMENTS LIST 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 20 4.4 EUT OPERATING CONDITIONS 21 4.5 FIELD STRENGTH CALCULATION 21 4.6 TEST RESULTS 22 5. DUTY CYCLE 43 5.1 TEST STANDARD 43 5.2 TEST PROCEDURE 43 5.3 DEVIATION FROM STANDARD 43 5.4 TEST SETUP 43 5.6 TEST RESULTS 43 6. CONDUCTED SPURIOUS & BAND EDGE EMISSION 44 6.1 LIMIT 44 6.2 TEST PROCEDURE 44 6.3 TEST SETUP 44 Page 4 of 77 Report No.: STS2601248W06 Table of Contents Page 6.4 EUT OPERATION CONDITIONS 44 6.5 TEST RESULTS 44 7. POWER SPECTRAL DENSITY TEST 45 7.1 LIMIT 45 7.2 TEST PROCEDURE 45 7.3 TEST SETUP 45 7.4 EUT OPERATION CONDITIONS 45 7.5 TEST RESULTS 45 8. BANDWIDTH TEST 46 8.1 LIMIT 46 8.2 TEST PROCEDURE 46 8.3 TEST SETUP 46 8.4 EUT OPERATION CONDITIONS 46 8.5 TEST RESULTS 46 9. PEAK OUTPUT POWER TEST 47 9.1 LIMIT 47 9.2 TEST PROCEDURE 47 9.3 TEST SETUP 47 9.4 EUT OPERATION CONDITIONS 47 9.5 TEST RESULTS 47 10. ANTENNA REQUIREMENT 48 10.1 STANDARD REQUIREMENT 48 10.2 EUT ANTENNA 48 APPENDIX 1-TEST DATA 49 DUTY CYCLE 49 MAXIMUM PEAK CONDUCTED OUTPUT POWER 53 -6DB BANDWIDTH 57 MAXIMUM POWER SPECTRAL DENSITY LEVEL 61 BAND EDGE 65 CONDUCTED RF SPURIOUS EMISSION 70 APPENDIX 2- EUT TEST PHOTO 77 Page 5 of 77 Report No.: STS2601248W06 Revision History Rev. Issue Date Report No. Effect Page Contents 00 25 Feb. 2026 STS2601248W06 ALL Initial Issue Page 6 of 77 Report No.: STS2601248W06 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted bands of operation PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- Note: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 77 Report No.: STS2601248W06 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.751dB 2 Unwanted Emissions, conducted ±2.888dB 3 All emissions, radiated 9K-30MHz ±2.48dB 4 All emissions, radiated 30M-1GHz ±2.52dB 5 All emissions, radiated 1G-18GHz ±3.48dB 6 All emissions, radiated>18GHz ±4.18dB 7 Conducted Emission (9KHz-150KHz) ±2.48dB 8 Conducted Emission (150KHz-30MHz) ±2.52dB 9 Occupied Channel Bandwidth ±3.6% 10 Power Spectral Density, conducted ±1.214dB 11 Duty Cycle ±3.2% Page 8 of 77 Report No.: STS2601248W06 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTIO…
Text truncated - open the document above for the full version.
Shenzhen Xinbinuo Communication Technology Co., Ltd Customer: JIU ZHOU Project: R6883D ME: Xiao Xiang-13316888409 RF: RiXin Huang - 13682667404 Date: 2026/1/20 Report Type: Version No.: V1.0 Status: T0 Frequency band: GSM:B2/B3/B5/B8 WCDMA:B1/B2/B4/B5/B8 FDD-LTE: B1/B2/B3/B4/B5/B7/B8/B12/B17/B18/B19/B20/B26/B28A/B28B/B66 TDD-LTE: B38/40/41 GPS 2.4G/5G WIFI/BT Antenna matching circuit: Shenzhen Xinbinuo Communication Technology Co., Ltd Shenzhen Xinbinuo Communication Technology Co., Ltd Passive main antenna : Passive GPS/Wifi/BT antenna : Shenzhen Xinbinuo Communication Technology Co., Ltd Passive Diversity antenna : Shenzhen Xinbinuo Communication Technology Co., Ltd Antenna gain: Frequency(MHZ) Gain(dBi) Frequency(MHZ) Gain(dBi) GSM850 -3.7 LTE B12 -4.3 GSM900 -3.0 LTE B17 -4.4 DCS1800 1.4 LTE B18 -3.8 PCS1900 1.7 LTE B19 -3.7 WCDMA B1 1.8 LTE B20 -3.6 WCDMA B2 1.7 LTE B26 -3.7 WCDMA B4 1.3 LTE B28 -4.2 WCDMA B5 -3.7 LTE B66 1.9 Shenzhen Xinbinuo Communication Technology Co., Ltd Main antenna OTA: WCDMA B8 -3.4 LTE B38 1.3 LTE B1 2.2 LTE B40 1.5 LTE B2 2.1 LTE B41 1.4 LTE B3 1.6 GPS 1.3 LTE B4 1.7 WIFI 2.4G/BT 1.1 LTE B5 -3.9 WIFI 5.8G 1.7 LTE B7 1.4 LTE B8 -3.2 Band Channel TRP TIS GSM 850 128 26.1 190 26.6 251 26.8 -101.5 Shenzhen Xinbinuo Communication Technology Co., Ltd EGSM900 1 27.5 62 27.7 124 28.0 -101.6 DCS1800 512 24.5 698 24.4 885 25.1 -102.5 PCS1900 512 26.2 661 26.2 810 25.7 -102.0 WCDMA Band 1 10562 18.2 10700 17.7 10838 17.1 -103.7 WCDMA Band 2 9662 18.0 9800 17.7 9938 17.2 -103.2 WCDMA Band 4 1538 17.0 1675 17.4 Shenzhen Xinbinuo Communication Technology Co., Ltd 1736 18.4 -101.8 WCDMA Band 5 4357 15.9 4400 16.2 4458 16.6 -104.2 WCDMA Band 8 2937 15.4 3013 16.5 3088 16.5 -100.3 Band Channel TRP TIS FDD-LTE (10M) B1 50 18.5 300 17.6 550 18.0 -93.3 B2 650 18.7 900 18.5 1150 18.3 -92.7 B3 1250 17.5 Shenzhen Xinbinuo Communication Technology Co., Ltd 1575 17.7 1900 18.6 -92.8 B4 2000 17.3 2175 17.7 2350 17.7 -93.3 B5 2450 16.9 2525 17.1 2600 17.4 -92.1 B7 2800 18.9 3100 18.0 3400 18.5 -92.2 B8 3500 16.6 3625 17.9 3750 18.2 -90.5 B12 5060 15.3 5095 15.7 5130 15.9 -90.8 Shenzhen Xinbinuo Communication Technology Co., Ltd B17 5780 15.8 5790 16.5 5800 16.9 -89.1 FDD-LTE (10M) B18 5900 16.7 5925 17.0 5950 17.4 -91.9 B19 6050 17.3 6075 17.5 6100 17.8 -91.9 B20 6200 17.7 6300 17.6 6400 17.9 -90.4 B26 8740 17.3 8865 17.8 8990 18.6 -91.0 B28A 9310 15.7 9360 16.2 Shenzhen Xinbinuo Communication Technology Co., Ltd WIFI OTA: 9460 16.1 -90.9 B28B 9410 16.5 9510 16.7 9560 17.8 -90.2 B66 66486 18.0 66886 17.4 67286 17.1 -91.4 TDD-LET(20M) B38 9410 18.5 9510 18.2 9560 18.5 -91.1 B40 38750 17.9 39150 18.2 39550 18.3 -91.8 B41 40620 17.3 -90.9 Shenzhen Xinbinuo Communication Technology Co., Ltd WIFI OTA 2.4G Band Channel TRP TIS b(11M) 1 12.5 6 13.3 13 14.0 -82.3 g(54M) 1 10.7 6 10.9 13 11.6 -71.2 n(MCS7) 1 10.5 6 11.0 13 11.8 -65.1 a(54M) 36 9.9 56 13.0 165 12.8 -73.2 Shenzhen Xinbinuo Communication Technology Co., Ltd 5G n(MCS7) 36 9.5 56 12.8 165 12.0 -66.8 AC(MCS7) 36 9.6 56 12.6 165 11.5 -64.5 GPS Test: Measured site:Ping'an Rd Weather:Sunny Max S/N :40.7 Stars:31 Positioning time:45s Shenzhen Xinbinuo Communication Technology Co., Ltd 3D Pattern Shenzhen Xinbinuo Communication Technology Co., Ltd Environmental treatment Shenzhen Xinbinuo Communication Technology Co., Ltd Shenzhen Xinbinuo Communication Technology Co., Ltd
SAR REFERENCE WAVEGUIDE CALIBRATION REPORT Ref: ACR.262.12. .MVGB.A Frequency (MHz) 1 g SAR (W/kg) 10 g SAR (W/kg) required measured required measured 5200 159.00 163.88 (16.39) 56.90 57.29 (5.73) 5400 166.40 172.23 (17.22) 58.43 59.16 (5.92) 5600 173.80 181.28 (18.13) 59.97 61.57 (6.16) 5800 181.20 188.95 (18.90) 61.50 63.45 (6.35) SAR MEASUREMENT PLOTS @ 5200 MHz SAR MEASUREMENT PLOTS @ 5400 MHz Page: 8/13 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 2 3 SAR REFERENCE WAVEGUIDE CALIBRATION REPORT Ref: ACR.262.12. .MVGB.A SAR MEASUREMENT PLOTS @ 5600 MHz SAR MEASUREMENT PLOTS @ 5800 MHz Page: 9/13 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 2 3 SAR REFERENCE WAVEGUIDE CALIBRATION REPORT Ref: ACR.262.12. .MVGB.A 7.3 BODY LIQUID MEASUREMENT Frequency MHz Relative permittivity ( r ’) Conductivity (σ) S/m required measured required measured 5200 49.0 ±10 % PASS 5.30 ±10 % PASS 5300 48.9 ±10 % 5.42 ±10 % 5400 48.7 ±10 % PASS 5.53 ±10 % PASS 5500 48.6 ±10 % 5.65 ±10 % 5600 48.5 ±10 % PASS 5.77 ±10 % PASS 5800 48.2 ±10 % PASS 6.00 ±10 % PASS 7.4 SAR MEASUREMENT RESULT WITH BODY LIQUID Software OPENSAR V4 Phantom SN 20/09 SAM71 Probe SN 18/11 EPG122 Liquid Body Liquid Values 5200 MHz: eps' :50.69 sigma : 4.98 Body Liquid Values 5400 MHz: eps' :48.45 sigma : 5.82 Body Liquid Values 5600 MHz: eps' :50.57 sigma : 6.37 Body Liquid Values 5800 MHz: eps' :48.19 sigma : 6.45 Distance between dipole waveguide and liquid 0 mm Area scan resolution dx=8mm/dy=8mm Zoon Scan Resolution dx=4mm/dy=4m/dz=2mm Frequency 5200 MHz 5400 MHz 5600 MHz 5800 MHz Input power 20 dBm Liquid Temperature 21 °C Lab Temperature 21 °C Lab Humidity 45 % Frequency (MHz) 1 g SAR (W/kg) 10 g SAR (W/kg) measured measured 5200 158.49 (15.85) 55.40 (5.54) 5400 167.20 (16.72) 57.39 (5.74) 5600 175.65 (17.57) 59.48 (5.95) 5800 183.06 (18.31) 61.62 (6.16) Page: 10/13 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 2 3 SAR REFERENCE WAVEGUIDE CALIBRATION REPORT Ref: ACR.262.12. .MVGB.A BODY SAR MEASUREMENT PLOTS @ 5200 MHz BODY SAR MEASUREMENT PLOTS @ 5400 MHz BODY SAR MEASUREMENT PLOTS @ 5600 MHz Page: 11/13 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 2 3 SAR REFERENCE WAVEGUIDE CALIBRATION REPORT Ref: ACR.262.12. .MVGB.A BODY SAR MEASUREMENT PLOTS @ 5800 MHz Page: 12/13 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 2 3 SAR REFERENCE WAVEGUIDE CALIBRATION REPORT Ref: ACR.262.12. .MVGB.A 8 LIST OF EQUIPMENT Equipment Summary Sheet Equipment Description Manufacturer / Model Identification No. Current Calibration Date Next Calibration Date Phantom MVG SN-20/09-SAM71 Validated. No cal required. Validated. No cal required. COMOSAR Test Bench Version 3 NA Validated. No cal required. Validated. No cal required. Network Analyzer Rhode & Schwarz ZVA SN100132 Calipers Carrera CALIPER-01 Reference Probe MVG EPG122 SN 18/11 Signal Generator Agilent E4438C MY49070581 Amplifier Aethercomm SN 046 Characterized prior to test. No cal required. Characterized prior to test. No cal required. Power Meter HP E4418A US38261498 Power Sensor HP ECP-E26A US37181460 Directional Coupler Narda 4216-20 01386 Characterized prior to test. No cal required. Characterized prior to test. No cal required. Temperature and Humidity Sensor Control Company 15098832 SAM Multimeter Keithley 2000 1188656 Page: 13/13 This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Dipole vH 02/202 02/2022 5 /2023 01/202 6 0/ 10/202 2022 3 /2023 01/202 6 /2023 01/202 6 01 1 01 01 /2023 01/202 6 /2023 01/202 6 01 01 11 /2023 11 /2020 2 3