FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. FUJIAN AOWEI FITNESS EQUIPMENT CO., LTD./
  3. 2BSYW-AW-80

2BSYW-AW-80Intelligent Massage Chair

FUJIAN AOWEI FITNESS EQUIPMENT CO., LTD.
Intelligent Massage Chair - FCC ID 2BSYW-AW-80 - FUJIAN AOWEI FITNESS EQUIPMENT CO., LTD.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Nov 26, 2025
Application Purpose
Original Equipment
Equipment Note
Intelligent Massage Chair
Frequency Range
2402.00000000 - 2480.00000000
Company
FUJIAN AOWEI FITNESS EQUIPMENT CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Intelligent Massage Chair User Manual 804 Manual Heat AUTO We reserve the right to finalinterpretation of the manual. The pictures are for references only,Please refer to the real subiect. 110-240V ,50/60Hz. •Refrain from using waist massage for individuals with acute low back pain, disc herniation, or lumbar displacement, as well as those suffering from arthritis. •Consult a doctor before usage if: •a. Muscle atrophy due to age or a thin body is present. •b. Low back pain is attributed to bone or visceral problems. •c. Prone to sprains, bruises, or violent reactions during transportation. •d. History of heart or organ surgery. •Stop using the device if rash, redness, itch, or other symptoms occur; consult a doctor. •Handle the power cord gently; avoid rude pulling. •Avoid using the device while wearing head jewelry such as hair clips. •Empty pants pockets (e.g., cell phone, keys) before using the device. •Remove watches, nail covers, and rings when massaging hands or arms. •Ensure the wheel is in the storage position before sitting down. •Stop the device's operation before leaving the seat to prevent accidents. •Avoid suddenly pulling out the power plug or turning off the power switch during the massage. •IRefrain from standing or sitting on the back cover and armrest to prevent tipping over and causing injury. •Do not move the device while someone is seated in the device to avoid acci- dents or injuries. •Avoid using the device on heating equipment like an electric blanket. •Do not place the remote control on the seat. •Ensure the device is connected to a socket with a matching grounding plug. Note: Follow these guidelines meticulously for a safe and effective user experience. •Ensure the device is grounded to reduce the risk of electric shock in the event of a functional failure. •Use the provided power cord with grounding lead and plug it into a properly installed and grounded outlet according to local codes and regulations. •Improper connection of the equipment's grounding lead poses an electric shock hazard; consult a professional electrician for inspection if unsure. •Do not modify the plug and socket attached to the appliance; professional electri- cians should handle proper socket installations. •Ensure the device is connected to a socket with a matching grounding plug shape; using adapter sockets is not allowed. •If the power cord is damaged, contact us for a replacement. Speakers Manual Heat AUTO Shoulder airbag Remote controller Arm airbag Seat cushion Leg part Pillow Cloak Quick-access button Armrest Electric cabinet Side cover plate Manual Heat Auto Zero Gravity Neck to buttocks: 2D manipulator massage Speakers Leg airbag massage; roller massage at the sole of foot Neck Massage Shoulder, arm airbag massage Heating in the waist HI-MASSAGE-CHAIR HI START-MASSAGE OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK END-MASSAGE INCREASE-MASSAGE REDUCE-MASSAGE START-MODE-ONE START-MODE-TWO START-MODE-THREE START-MODE-FOUR START-MODE-FIVE START-MODE-SIX START-HEAT END-HEAT INCREASE-AIR REDUCE-AIR START-FOOT END-FOOT BACK-RISE BACK-DOWN BACK-STOP START-AIR END-AIR START-ZERO Command Reply Wake up words Power on Power off Increase massage intensity MODE - ONE MODE - TWO MODE - THREE MODE - FOUR END-ZERO MODE - FIVE MODE - SIX Turn on heating Turn off heating Increase airbag strength Reduce airbag strength Start foot massage End foot massage Back-rise massage Back-down massage Back-stop massage Start massage End air massage Start -zero grarity End zero grarity Reduce massage intensity Function When you hear the AI voice "Thank you for using", you need to say "Hi Massage Chair" to wake up the massage chair for using. SPEED This device is equipped with an offline voice AI function. The command entries are as follows: 7.9 inch The area of base Cushion The area of leg Diagram 1 1) 2) 3) 143 lbs Gently lower the device with caution to avoid crushing your feet. Avoid opening the legs until the appliance is completely flat, as a sudden release may cause the legs to bounce back, potentially damaging the floor. For added protection, it is advisable to place cushions or other items on the floor. Diagram 2 1) 2) 3) Diagram 3 Avoid excessive pressure to prevent damage caused by the chair falling completely When using the caster for movement, place a cushion on the floor to prevent floor scratching. Exercise caution to maintain the device's integrity during use. device device INSTRUCTION Precautions before use Manu a l Heat A UTO Prior to use, check the surroundings to ensure no people, pets, or objects are near the appliance. Ensure a clear and safe environment for operation. INSTRUCTION Manu a l Heat A UTO 1.Ensure there are no foreign objects between the machine gaps. 2.Check for any items in the leg, foot, and other positions before starting the massage. INSTRUCTION Manual Heat Auto Zero Gravity Key inspection area 3. Check the fabric for damage and ensure there are no cracks. Pay special attention to the fabric covering the massage balls in the backrest area. us via ordernumber. MGC-804 110-240V ,50/60Hz INSTRUCTION Password:8888. device's device's device device 1) 2) This product with a wireless charging function, charging power of 10W. If your phone with a wireless charging function, you can put it on the wireless charging area for charging. Adjustable recline angle 129°~152°; Max shoe size 44. 110-240V ,50/60Hz device's device device SPEED WIDE TIME Upon opening, the massage chair automatically reclines for shoulder position adjustment. When turned off, the display screen powers down, and the massage chair returns to the standby position. Note these operational features for convenient use. In Automatic transmission mode A1, the massage chair provides even massage coverage to the neck, waist, and hips. This mode incorporates various techniques such as kneading, eight-character kneading, and dynamic kneading. It offers a rich combination of beating actions with different st…

Text truncated - open the document above for the full version.

Attestation Statements

FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. U.S.AgentLetterofAttestation To:FederalCommunicationsCommissionDate:Nov.26,25 [FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD.](“theapplicant”)certifiesthat,asofthedateof thefilingoftheapplication,[TRANS-PACCHINALLC](“theagent”)isourdesignatedU.S.agentfor serviceofprocessfortheabovereferenceFCCID.Theapplicantacceptstomaintainanagentfor serviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., ortheconclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingthe equipment,whicheverislater.Theapplicantfurtheracknowledgesitisourresponsibilitytoinform theFCCwhenevertheagentinformationchanges. [TRANS-PACCHINALLC]("theagent)understanditistheagent'sobligationtoacceptserviceof processintheUnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddress. DesignatedU.S.Agen 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: [2BSYW-AW-80] t CompanyName:TRANS-PACCHINALLC FRN:0036394526 Address: 3715S182ndStreet,C120Seatac,WA98188 UnitedStates Signature: ContactPerson:LisaLee Tel:(818)818-0538 Email:[email protected] Applicant CompanyName:FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. FRN:0037615259 Address:SecondFloor,3rdFloor,132SansheRoad, GuankouTown,JimeiDistrict,Xiamen,Fujian,China Signature: ContactPerson:MinggaiZhou Tel:+8613537687759 Email:[email protected]

Attestation Statements

FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:Nov.26,25 7435OaklandMillsRoad, Columbia,MD21046,USA FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD.(“theapplicant”)certifiesthat,asofthedateofthefilingof theapplication,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002of referencechapter,asanentityproducing“covered”communicationequipment.Theequipmentforwhich authorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillanceequipment producedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfromreceivinganequipment authorizationpursuanttosection§2.903oftheFCCrules Ref: Information Required by Section 2.911(d)(5)(i) & (ii) FCC ID: 2BSYW-AW-80 . Sincerelyyours, ApplicantSignature PrintedName:MinggaiZhou Title::ElectricalEngineer Address:SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict,Xiamen,Fujian,China Tel.:+8613537687759 Email:[email protected]

Attestation Statements

FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Nov.26,25 7435OaklandMillsRoad, Columbia,MD21046,USA Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered Subject: Attestation of Compliance with FCC Covered List Software Requirements FCC ID: 2BSYW-AW-80 Product Name: Intelligent Massage Chair " softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:MinggaiZhou Title::ElectricalEngineer Address:SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict,Xiamen,Fujian,China Tel.:+8613537687759 Email:[email protected] FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck

Cover Letter(s)

DifferencesDeclaration Towhomconcern, WeFUJIANAOWEIFITNESSEQUIPMENTCO.,LTD.Hereby declares: TheproductmodelAW-80isthesamePCBlayout,electronic schematicandAntennawith804-1,804-2,804-3,804-4,RMP22-SCH, RMP23-BEI,RMC-EL-804L,MC-5000,MGC-804,HD-T804,AW-804- 3A. Accordingtodifferentmarketsdemand,Weusedifferentmodelsto distinguish.Inadditiontothemodeldifference,wemakesurethatthe productsaresame. Sincerelyyours, Signature: Name(inprint):MinggaiZhou Title:(ElectricalEngineer) Tel:+8613537687759 Email:[email protected] Date:2025.11.26

Cover Letter(s)

FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD.  BlockDiagram Schematics  OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. Sincerely, (Signature) Title:ElectricalEngineer Address:SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict,Xiamen,Fujian, China Tel.:+8613537687759 Email:[email protected] (Nov. 21, 2025) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject:Confidentiality Request for: FCC ID: 2BSYW-AW-80 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request permanent confidential treatment of the exhibits accompanying this certification application as outlined below : m

Cover Letter(s)

FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. Sincerely, (Signature) MinggaiZhou (ElectricalEngineer) Tel:+8613537687759 Fax:/ Email:[email protected] (Nov. 21, 2025) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID:2BSYW-AW-80 I, the undersigned, hereby authorize (Guangdong KEYS Testing Technology Co., Ltd.) to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by (Guangdong KEYS Testing Technology Co., Ltd.) shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by DERYCOM CERTIFICATION SERVICES, INC., still resides with FUJIAN AOWEI FITNESS EQUIPMENT CO., LTD. We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. m

External Photos

FCCID:2BSYW-AW-80 Page 1 / 3 PHOTOSOFEUTEXTERNALPHOTOS EUTPhoto EUTPhoto FCCID:2BSYW-AW-80 Page 2 / 3 EUTPhoto EUTPhoto FCCID:2BSYW-AW-80 Page 3 / 3 EUTPhoto EUTPhoto

ID Label/Location Info

FCCID:2BSYW-AW-80

Internal Photos

FCCID:2BSYW-AW-80 Page 1 / 4 PHOTOSOFEUTEXTERNALPHOTOS EUTPhoto EUTPhoto FCCID:2BSYW-AW-80 Page 2 / 4 EUTPhoto EUTPhoto FCCID:2BSYW-AW-80 Page 3 / 4 EUTPhoto EUTPhoto FCCID:2BSYW-AW-80 Page 4 / 4 EUTPhoto EUTPhoto

RF Exposure Info

TestReport ReportNo.:RKEYS251013039Date:Oct.13,2025Page1of6 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection.This reportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. RFEXPOSUREEVALUATIONREPORT for Product:IntelligentMassageChair Model:AW-80,804-1,804-2,804-3,804-4,RMP22-SCH,RMP23-BEI,RMC-EL-804L, MC-5000,MGC-804,HD-T804,AW-804-3A FCCID:2BSYW-AW-80 ReportNo.:RKEYS251013039 Issuedfor FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. SecondFloor,3rdFloor,132SansheRoad,GuankouTown,Jimei District,Xiamen,Fujian,China Issuedby GuangdongKEYSTestingTechnologyCo.,Ltd. Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong, China ReportNo.:RKEYS251013039Date:Oct.13,2025Page 2 of 6 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection.This reportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. TABLEOFCONTENTS PAGE 1.TESTCERTIFICATION...................................................................................................................................................3 2.GENERALINFORMATION............................................................................................................................................4 2.1.GENERALDESCRIPTIONOFE.U.T..........................................................................................................................4 3.RFEXPOSUREEVALUATION.......................................................................................................................................5 3.1.REQUIREMENT.............................................................................................................................................................5 3.2.TUNE-UPRESULT.........................................................................................................................................................5 3.3.EVALUATIONRESULT................................................................................................................................................6 3.4.CONCLUSION.................................................................................................................................................................6 ReportNo.:RKEYS251013039Date:Oct.13,2025Page 3 of 6 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection.This reportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. 1. TESTCERTIFICATION Product:IntelligentMassageChair Trademark:/ FCCID:2BSYW-AW-80 Model:AW-80 ModelList(s): 804-1,804-2,804-3,804-4,RMP22-SCH,RMP23-BEI,RMC-EL-804L, MC-5000,MGC-804,HD-T804,AW-804-3A Applicant:FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. Address: SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict, Xiamen,Fujian,China Manufacturer:FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. Address: SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict, Xiamen,Fujian,China Applicable Standards: CFR47,FCCPart2.1093 KDB447498D01V06 TheaboveequipmenthasbeentestedbyGuangdongKEYSTestingTechnologyCo.,Ltd.andfound compliancewiththerequirementsinthetechnicalstandardsmentionedabove.Thetestresults presentedinthisreportonlyrelatetotheproduct/systemtested.Theothersimilarequipmentwillnot necessarilyproducethesameresultsduetoproductiontoleranceandmeasurementuncertainties. Preparedby: EvanFang/Engineer Approvedby:BruceZhang/Manager ReportNo.:RKEYS251013039Date:Oct.13,2025Page 4 of 6 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection.This reportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. 2. GENERALINFORMATION 2.1.GeneralDescriptionofE.U.T. ProductName IntelligentMassageChair ModelName AW-80 SpecificationBluetooth Operating frequency 2402-2480MHz NumberofChannel 79 Antennainstallation PCBantenna AntennaGain 1.68dBi TypeofModulation GFSK,π/4-DQPSK,8DPSK ReportNo.:RKEYS251013039Date:Oct.13,2025Page 5 of 6 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection.This reportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. 3. RFEXPOSUREEVALUATION 3.1.Requirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06Section4.3.1 StandaloneStandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1-gheador bodyand10-gextremitySARevaluationforgeneralpopulationexposurecondit…

Text truncated - open the document above for the full version.

Test Report

TestReport ReportNo.:RKEYS250922046Date:Nov.26,2025Page1of41 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection. Thisreportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. FCCRFTESTREPORT For Product:IntelligentMassageChair Model:AW-80,804-1,804-2,804-3,804-4,RMP22-SCH,RMP23-BEI,RMC-EL-804L, MC-5000,MGC-804,HD-T804,AW-804-3A FCCID:2BSYW-AW-80 ReportNo.:RKEYS250922046 Issuedfor FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict,Xiamen, Fujian,China Issuedby GuangdongKEYSTestingTechnologyCo.,Ltd. Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong, China ReportNo.:RKEYS250922046Date:Nov.26,2025Page 2 of 41 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection. Thisreportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. TABLEOFCONTENTS 1.TESTCERTIFICATION..................................................................................................3 2.TESTSUMMARY............................................................................................................4 3.TESTSITE.......................................................................................................................5 3.1.TESTFACILITY.........................................................................................................................5 3.2.MEASUREMENTUNCERTAINTY............................................................................................5 3.3.TESTENVIRONMENTCONDITION.........................................................................................5 4.TESTEQUIPMENTLIST................................................................................................6 5.EUTDESCRIPTION........................................................................................................8 5.1.DESCRIPTIONOFTESTCONFIGURATION.............................................................................9 5.2.EQUIPMENTMODIFICATIONS................................................................................................9 6.TESTMETHODOLOGY................................................................................................10 6.1.EUTSYSTEMOPERATION.....................................................................................................10 7.SETUPOFEQUIPMENTUNDERTEST.......................................................................11 7.1.DESCRIPTIONOFSUPPORTUNITS.......................................................................................11 7.2.BLOCKDIAGRAMOFEUTCONFIGURATION......................................................................11 7.3.EUTEXERCISESOFTWARE...................................................................................................11 8.TESTRESULTSANDMEASUREMENTDATA............................................................12 8.1.ANTENNAREQUIREMENT....................................................................................................12 8.2.MAXIMUMCONDUCTEDOUTPUTPOWER..........................................................................13 8.3.99%BANDWIDTH...................................................................................................................15 8.4.20DBBANDWIDTH.................................................................................................................17 8.5.CARRIERFREQUENCYSEPARATION...................................................................................19 8.6.NUMBEROFHOPPINGFREQUENCY....................................................................................21 8.7.TIMEOFOCCUPANCY(DEWLLTIME)..................................................................................23 8.8.OUTOFBANDCONDUCTEDEMISSIONS.............................................................................25 8.9.BANDEDGE............................................................................................................................27 8.10.RADIATEDSPURIOUSEMISSIONS......................................................................................30 8.11.CONDUCTEDEMISSION......................................................................................................37 9.PHOTOGRAPHSOFTESTSET-UP..............................................................................40 10.PHOTOGRAPHSOFEUT............................................................................................41 ReportNo.:RKEYS250922046Date:Nov.26,2025Page 3 of 41 GuangdongKEYSTestingTechnologyCo.,Ltd. Address:Building1,No.18,ShihuanRoad,DongchengSubdistrict,Dongguan,Guangdong,China Tel:+86-0769-22221088http://www.keys-lab.comE-mail:[email protected] Thisreportisonlyresponsibleforthetestresultsofthesamplessubmittedforinspection,andisnotresponsibleforthesourceofthesamplessubmittedforinspection. Thisreportshallnotbealtered,increasedordeleted.WithoutwrittenapprovalofKEYS,thistestreportshallnotbecopiedexceptinfullandpublishedasadvertisement. 1.TESTCERTIFICATION Product: IntelligentMassageChair Trademark: / Model: AW-80 Applicant: FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. Address: SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict, Xiamen,Fujian,China Manufacturer: FUJIANAOWEIFITNESSEQUIPMENTCO.,LTD. Address: SecondFloor,3rdFloor,132SansheRoad,GuankouTown,JimeiDistrict, Xiam…

Text truncated - open the document above for the full version.

Test Report

Antennaspecification QuickReferenceDate FrequencRange 2400~2500MHz Ant.PortInputPwr.(dBm) 0(Typ.BTclass2outputpower) Tot.Rad.Pwr.(dBm)-1.2(Inputpwr–losspwr) PeakEIRP(dBm) Directivity(dBi) 1(alldirectionantenna) Efficiency(dB) 60.2% Gain(dBi) 1.68(PeakGainXZ-plane) MaximumPower(dBm)1.7(XY-plane) MinimumPower(dBm)-4(XY-plane) Avg.Power(dBm)-0.5(XY-plane) InputImpendence(ohm)50 PolarizationType Vertical&Horizontal VSWR <1.4 Manufacturer : FUJIANAOWEIFITNESSEQUIPMENTCO., LTD. AntennaLayout&moduleonthesystemboard AntennaGain GainTable [email protected] XZ-planeYZ-plane Efficiency Peak Avg. Peak Avg. Peak Avg. ModuleBoard 1.35-0.581.68 -1.42 1.11 -1.07 60.2% ReturnLoss TheEnvironmentofAntennaRadiationPattem 3Dradiationpatterndiagram XY-plane XZ-planeYZ-plane

Test Report

FCCID:2BSYW-AW-80 1/15 AppendixA:TestResultsofBluetoothBR&EDR DutyCycle TestResult ModulationPacketsChannel OnTime (ms) Period (ms) DutyCycle (%) DutyCycle (linear) DutyCycle Factor(dB) 1/T GFSKDH5 02.8863.74877.000.77001.13510.3465 392.8863.74877.000.77001.13510.3465 782.8863.74877.000.77001.13510.3465 π/4DQPSK2-DH5 02.8923.74877.160.77161.12610.3458 392.8923.74877.160.77161.12610.3458 782.8923.74877.160.77161.12610.3458 8DPSK3-DH5 02.8943.74877.210.77211.12330.3455 392.8923.74877.160.77161.12610.3458 782.8943.74877.210.77211.12330.3455 TestGraphs GFSK(DH5)_Channel0GFSK(DH5)_Channel39 GFSK(DH5)_Channel78π/4DQPSK(2-DH5)_Channel0 FCCID:2BSYW-AW-80 2/15 π/4DQPSK(2-DH5)_Channel39π/4DQPSK(2-DH5)_Channel78 8DPSK(3-DH5)_Channel08DPSK(3-DH5)_Channel39 8DPSK(3-DH5)_Channel78 FCCID:2BSYW-AW-80 3/15 ConductedOutputPower TestResult ModulationPacketTypeChannel PeakOutput Power (dBm) PeakOutput Power (mW) Limit (dBm) Result GFSKDH5 0-0.760.84 ≤30 PASS 39-0.810.83PASS 78-1.210.76PASS π/4DQPSK2-DH5 0-0.730.84PASS 39-0.780.83PASS 78-1.270.75PASS 8DPSK3-DH5 0-0.730.85PASS 39-0.760.84PASS 78-1.200.76PASS TestGraphs PeakOutputPower GFSK_Channel0 PeakOutputPower GFSK_Channel39 PeakOutputPower GFSK_Channel78 PeakOutputPower π/4DQPSK_Channel0 FCCID:2BSYW-AW-80 4/15 PeakOutputPower π/4DQPSK_Channel39 PeakOutputPower π/4DQPSK_Channel78 PeakOutputPower 8DPSK_Channel0 PeakOutputPower 8DPSK_Channel39 PeakOutputPower 8DPSK_Channel78 FCCID:2BSYW-AW-80 5/15 99%Bandwidth TestResult ModulationChannelCenterFrequency(MHz)99%BW(MHz) GFSK 024020.87590 3924410.87354 7824800.86151 π/4DQPSK 024021.1956 3924411.2154 7824801.2010 8DPSK 024021.2147 3924411.2160 7824801.2082 TestGraphs GFSK_DH5_Channel0π/4DQPSK_2-DH5_Channel0 GFSK_DH5_Channel39π/4DQPSK_2-DH5_Channel39 GFSK_DH5_Channel78π/4DQPSK_2-DH5_Channel78 FCCID:2BSYW-AW-80 6/15 8DPSK_3-DH5_Channel08DPSK_3-DH5_Channel39 8DPSK_3-DH5_Channel78 FCCID:2BSYW-AW-80 7/15 20dBBandwidth TestResult ModulationChannelCenterFrequency(MHz)20dBBandwidth(MHz) GFSK 02402MHz1.006 392441MHz0.9651 782480MHz1.029 π/4DQPSK 02402MHz1.308 392441MHz1.312 782480MHz1.318 8DPSK 02402MHz1.295 392441MHz1.299 782480MHz1.294 TestGraphs GFSK_DH5_Channel0GFSK_DH5_Channel39 GFSK_DH5_Channel78π/4DQPSK_2-DH5_Channel0 π/4DQPSK_2-DH5_Channel39π/4DQPSK_2-DH5_Channel78 FCCID:2BSYW-AW-80 8/15 8DPSK_3-DH5_Channel08DPSK_3-DH5_Channel39 8DPSK_3-DH5_Channel78 FCCID:2BSYW-AW-80 9/15 CarrierFrequenciesSeparation TestResult ModulationPacket LeftCenter frequency (MHz) RightCenter frequency (MHz) Hopping Frequency Separation (MHz) Limit(MHz)Result GFSKDH52440.08132441.20251.12120.74PASS π/4DQPSK2-DH52439.88332441.21091.32760.92PASS 8DPSK3-DH52440.04892441.18391.13500.92PASS TestGraphs GFSKπ/4DQPSK 8DPSK FCCID:2BSYW-AW-80 10/15 ConductedOutOfBandEmission TestResult Non-Hopping ModulationPacketChannel OOB Emission Frequency (MHz) OOB Emission Level (dBm) Limit (dBm) OverLimit (dB) Result GFSKDH5 0 2400.00-51.201-20.86-30.341PASS 7206.38-37.963-20.86-17.103PASS 397323.74-35.144-20.93-14.214PASS 78 2483.50-57.837-21.25-36.587PASS 7439.85-39.227-21.25-17.977PASS π/4DQPSK2-DH5 0 2400.00-50.828-20.8-30.028PASS 7206.38-44.328-20.8-23.528PASS 397323.11-40.016-20.86-19.156PASS 78 2483.50-57.199-21.31-35.889PASS 7439.85-47.432-21.31-26.122PASS 8DPSK3-DH5 0 2400.00-52.494-20.8-31.694PASS 7206.38-35.440-20.8-14.640PASS 397323.74-41.271-21.12-20.151PASS 78 2483…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Minggai Zhou
[email protected]Fax: /

Test Firm

Guangdong KEYS Testing Technology Co., Ltd.Bruce Zhang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz900.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.