Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
3 45 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.Any changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. lf this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 2 Charging instructionsUseful diagram Table of Toxic and Hazardous Substances or Element English PARAMETER Mode PBE1020 Battery Lithium Polymer Wireless charging schematic diagram Battery Capacity 10000mAh/3.85V/38.5Wh Type-C Input 5V 3A /9V 2A/12V 1.5A 18W(Max) 15W (Max)/10W/7.5W/5W Size 1 Click to turn on the LED power indicator light. Without load, the light will automatically go o in about 35 seconds. Warnings Product Manual Wrapping paper Packing box Electronic parts Battery PCB Plastic indicates that said hazardous substance in all af the homogeneous materials for this part is below the limit requirement of SJ/T11363-2006. Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of SJ/T11363-2006. X Name of Hazardous Substance if the battery is not replaced properly, there will be a risk of explosion, if it is replaced with the wrong model of battery pack, there will be a risk of re or explosion, and it can only be replaced with the same type or equivalent type of battery. The battery must not be exposed to environments such as sunlight, re roasting, or similar excessive heat. When using, it should be placed in a place that is easy to dissipate heat, and should not be placed at the head of the bed, on the bedding, in the package or other environments that are not easy to dissipate heat. Avoid rainwater and other liquid erosion, and avoid infants and young children from cantact and play. Do not use this product in a high temperature or humid environment or leave it idle: Do not expose to the sun. The temperature range of this product: 0°C~25°C: (lt is recommended not to work in an environment higher than 25°C, and it is recommended not to work in an environment below 0°C.)) The storage temperature range of this product: -5°C~35°C, it cannat be left for a long time above the ambient temperature of 35°C. Do not cover or obscure this product with paper or other objects to avoid hindering the heat dissipation and cooling of this product. Do not use this product unattended. Do not drop, vibrate, knock, impact, or squeeze this product vigorously. Do not short circuit the positive and negative electrodes of the input or output of the product, To avoid re from equipment or external obiects. Please check that the output voltage of the charger matches this product before using this product, To avoid preduct damage. If the voltage of the charger does not match, it will cause the power bank to be overloaded,causing smoke, re and other dangers. Please unplug the charger after each full charge of the power bank. lf the power bank has abnormal conditions such as odor, heat, discoloration, deformation, night leakage and other abnormalitiles during use; Please deactivate it immediately. The battery should not be disassembled, impacted, squeezed or thrown into the re. Do not continue to use if severe buige occurs, Do not place in a high temperafure evirenment.it is forbidden to use it afterimmersion. The time when the product is in contact with the product indicator light should not exceed 1 minute. Dispose of it properly when disposed of. The product should be placed on the desktop when used, and the contact time shouid be less than 10s if it needs to be used in contact with the human body. If the skin gets on the battery liquid, wash it immediately with tap water and seek medical attention promptly. PbPBBPBDECdHgCr(VI) Wireless Charging 108.48*67.78*23.55mm 5V 3A /9V 2.22A/12V 1.67A/5V 4.5A/10V 2A 20W(Max) Type-C o u t put PBE1020 10000mAh JUCANI Wireless Charging POWER BANK
jucaniinc (SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154) AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:March31,2026 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BTY9-PBE1020 jucaniinc(“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,theapplicantisnot identifiedontheCoveredList,establishedpursuantto§1.50002ofreferencechapter,asanentity producing“covered”communicationequipment.Theequipmentforwhichauthorizationissoughtisnot “covered”telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentities identifiedontheCommission’sCoveredListthatprohibitedfromreceivinganequipmentauthorization pursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:BILLJIANG Title:CEO Address:SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154 Tel.:4709397499 Email:[email protected]
jucaniinc (SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154) 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:December4,2025 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:[2BTY9-PBE1020] ProductName:[JUCANIWirelessChargingPOWERBANK] Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:BILLJIANG Title:Manager Address:SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154 Tel.:4709397499 Email:[email protected] jucaniinc (SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154) 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) compliance ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck SBOM(SoftwareBillofMaterials)[ForDeviceisnotInherentcompliance] SectionComponentNameVersionSupplier 1 2 3
jucaniinc (SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154) U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:Apr.2,26 Ref:AttestationStatement–Part2.911(d)(7)filing FCCID:[2BTY9-PBE1020] [ jucaniinc ](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,[jucaniinc] (“theagent”)isourdesignatedU.S.agentforserviceofprocessfortheabovereferenceFCCID. TheapplicantacceptstomaintainanagentforserviceofprocessintheUnitedStatesfornoless thanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketingandimportationof theapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission-related administrativeorjudicialproceedinginvolvingtheequipment,whicheverislater.Theapplicant furtheracknowledgesitisourresponsibilitytoinformtheFCCwhenevertheagentinformation changes. [jucaniinc]("theagent)understanditistheagent'sobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S.addressand emailaddress. DesignatedU.S.Agent CompanyName:jucaniinc FRN:0037816311 Address: SuiteA2,7498ColchesterCourt,SanDiego, CA,US,92154 Signature: Tel:4709397499Email:[email protected] Applicant CompanyName:jucaniinc FRN:0037816311 Address:SuiteA2,7498ColchesterCourt,SanDiego, CA,US,92154 Signature: ContactPerson:BILLJIANG Tel:4709397499Email:[email protected]
jucaniinc (SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154) (March31,2026) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BTY9-PBE1020 PursuanttoSections0.457and0.459oftheCommission’s Rules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: Block Diagram Schematics Operational Description Sincerely, (Signature) Title:CEO Address:SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154 Tel.:4709397499 Email:[email protected]
jucaniinc (SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154) (March31,2026) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BTY9-PBE1020 I,theundersigned,herebyauthorize(ShenzhenHaiyunStandardTechnicalCO.,Ltd.)toactonourbehalf inallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(ShenzhenHaiyunStandardTechnicalCO.,Ltd.)shallhavethesameeffectasour ownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsofcertification, asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(jucaniinc). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, (Signature) (FullnameofcontactpersonlistedonFCC’swebsite)BILLJIANG (Title)CEO Tel:4709397499 Fax:/ Email:[email protected]
jucaniinc (SuiteA2,7498ColchesterCourt,SanDiego,CA,US,92154) APPLICANTCOMPANYLETTERHEAD We(jucaniinc)ProducemodelPBE1020,andseries models:PB-Elite-10K-20W,thedifferenceisOnlythemodelnameand colorsaredifferent,therestisthesame. Company:jucaniinc Date:2026-2-5 Signature:
FCC ID: 2BTY9-PBE1020 Page 1 / 3 EUTEXTERNALPHOTO EUTPhoto EUTPhoto FCC ID: 2BTY9-PBE1020 Page 2 / 3 EUTPhoto EUTPhoto FCC ID: 2BTY9-PBE1020 Page 3 / 3 EUTPhoto EUTPhoto
Lableand location
FCC ID: 2BTY9-PBE1020 Page 1 / 2 EUT INTERNAL PHOTOS EUT Photo EUT Photo FCC ID: 2BTY9-PBE1020 Page 2 / 2 EUT Photo EUT Photo Coil Antenna
HY-F CC 2.1093 Ver.1.1 Page 1 / 8Report No.: RF251229036-01-002 RF EXPOSURE REPORT FCC ID: 2BTY9-PBE1020 Test Report No...........: RF251229036-01-002 Product(s) Name.........: JUCANI Wireless Charging POWER BANK Model(s)....................: PBE1020, PB-Elite-10K-20W Trade Mark................: Applicant...................: jucani inc Address....................: Suite A2, 7498 Colchester Court San Diego, California 92154 Receipt Date..............: 2025.12.31 Test Date...................: 2026.01.07 ~ 2026.01.29 Issued Date................: 2026.01.30 Standards..................: FCC CFR Title 47 Part 1 §1.1307 FCC CFR Title 47 Part 1 §1.1310 FCC CFR Title 47 Part 2 §2.1093 KDB 680106 D01 Wireless Power Transfer v04 Testing Laboratory......: Shenzhen Haiyun Standard Technical Co., Ltd. Prepared By: Checked By: Approved By: Jason Huang Black Ding Tim Zhang HY-FCC 2.1093 Ver.1.1 Page 2 / 8 Report No.: RF251229036-01-002 Table of Contents History of this test report ............................................................................... 3 1. General Information .................................................................................. 4 1.1 General Description of EUT ................................................................................... 4 1.2 Test Location .......................................................................................................... 4 1.3 Description of support units ................................................................................... 4 1.4 Equipment used during test ................................................................................... 4 1.5 Measurement Uncertainty ...................................................................................... 4 2. RF exposure limit ...................................................................................... 5 3. Test setup for WPC ................................................................................... 6 4. Test results ................................................................................................ 7 HY-FCC 2.1093 Ver.1.1 Page 3 / 8 Report No.: RF251229036-01-002 History of this test report Original Report Issue Date: 2026.01.30 ● No additional attachment ○ Additional attachments were issued following record Attachment No. Issue Date Description HY-FCC 2.1093 Ver.1.1 Page 4 / 8 Report No.: RF251229036-01-002 1. General Information 1.1 General Description of EUT Sample No. POC251229036-S001 Product name JUCANI Wireless Charging POWER BANK Model name PBE1020, PB-Elite-10K-20W Test model PBE1020 Model difference Only the model name and colors are different Trade mark Power supply: DC 5V from adapter or DC 3.85V from battery WPT Output Power: 15W Max/10W/7.5W/5W Modulation type ASK Operating frequency 111-205kHz Antenna type Coil Antenna Antenna Gain 0 dBi 1.2 Test Location Company: Shenzhen Haiyun Standard Technical Co., Ltd. Address: No. 110-113, 115, 116, Block B, Jinyuan Business Building, Bao'an District, Shenzhen, China CNAS Registration Number: CNAS L18252 CAB identifier CN0145 A2LA Certificate Number 6823.01 1.3 Description of support units The EUT has been tested with associated equipment below: Description Manufacturer Model S/N Wireless charger load EESON SLY-YZB-A01 / 1.4 Equipment used during test The antennas provided to the EUT, please refer to the following table: No. Equipment Manufacturer Type No. Serial No. Calibration date Calibration interval 1 Electric and Magnetic Field Probe-Analyzer Narda EHP-200AC 180ZX10204 2025.04.24 1 year 1.5 Measurement Uncertainty Test Item Frequency Range Measurement Uncertainty Notes E-field 3kHz~30MHz ±7.5% (1) H-field 3kHz~30MHz ±7.5% (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. HY-FCC 2.1093 Ver.1.1 Page 5 / 8Report No.: RF251229036-01-002 2. RF exposure limit §1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of human expo sure to radio frequency(RF) radiation as specified in § 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of § 2.1093 of this chapter. HY-FCC 2.1093 Ver.1.1 Page 6 / 8Report No.: RF251229036-01-002 3.Test setup for WPC Note: Measurements should be made from all sides and the top of the primary/client pair, with the 0 cm measured from the probe(s) to the edge of the device. Equipment Approval Considerations: The EUT comply with KDB 680106 D01 Wireless Power Transfer v04. 1.Power transfer frequency is less than 1 MHz. Yes, the device operated in the frequency range from 111kHz to 205kHz. 2.The output power from each transmitting element (e.g., coil) is less than or equal to 15 watts. Yes, The maximum output power of each primary coil is 15 watts. 3.A client device providing the maximum permitted load is placed in phys ical contact with the transmitter(i.e., the surfaces of the transmitter and client device enclosures need to be in physical contact) Yes, the client device includes only single primary coil. 4. Only § 2.1091-Mobile exposure conditions apply (i.e., this provision does not cover § 2.1093-Portable exposure conditions). No, The EUT has portable exposure conditions. 5. The E-field and H-field strengths, at and beyond 20 cm surrounding the device surface, are demonstrated to be less than 50% of the applicable MPE limit, per KDB 447498, Table 1. Yes; The EUT’s field strength levels are less than 50% of the MPE limit. 6. For systems with more than one radiating structure, the conditions specified in (5) must be met when the system is fully loaded (i.e., clients absorbing maximum power available), and with all the radiating structures operating at maximum power at the same time, as per design conditions. Yes, the EUT has only one coil, all test modes met the conditions specified in (5). HY-FCC 2.1093 Ver.1.1 Page 7 / 8 Report No.: RF251229036-01-002 4. Test results Test Mode Description Mode 1 Charging …
Text truncated - open the document above for the full version.
HY- FCC part 15C Ver.1.1 Page 1 / 21Report No.: RF251229036-01-001 RF TEST REPORT FCC ID: 2BTY9-PBE1020 Test Report No...........: RF251229036-01-001 Product(s) Name.........: JUCANI Wireless Charging POWER BANK Model(s)....................: PBE1020, PB-Elite-10K-20W Trade Mark................: Applicant...................: jucani inc Address....................: Suite A2, 7498 Colchester Court San Diego, California 92154 Receipt Date..............: 2025.12.31 Test Date...................: 2026.01.07 ~ 2026.01.29 Issued Date................: 2026.01.30 Standards..................: 47 CFR FCC Part 15, Subpart C; ANSI C63.10:2020 Testing Laboratory......: Shenzhen Haiyun Standard Technical Co., Ltd. Prepared By: Checked By: Approved By: Jason Huang Black Ding Tim Zhang HY- FCC part 15C Ver.1.1 Page 2 / 21 Report No.: RF251229036-01-001 Table of Contents History of this test report ............................................................................... 4 1. General Information .................................................................................. 5 1.1 Applicant ................................................................................................................ 5 1.2 Manufacturer .......................................................................................................... 5 1.3 Basic Description of Equipment Under Test ........................................................... 5 1.4 Application of Standard .......................................................................................... 5 1.5 Independent Operation Modes .............................................................................. 5 2. Summary of Test Results ......................................................................... 6 2.1 Summary of Test Items .......................................................................................... 6 2.2 Special Accessories and Auxiliary Equipment ........................................................ 6 2.3 Test Condition ........................................................................................................ 6 2.4 Principle of Configuration Selection ....................................................................... 6 2.5 Test Instruments..................................................................................................... 7 2.6 Measurement Uncertainty ...................................................................................... 8 2.7 Test Location .......................................................................................................... 8 3. Test Procedure And Results .................................................................... 9 3.1 AC Power Line Conducted Emission ..................................................................... 9 3.1.1 Limit ................................................................................................................................ 9 3.1.2 Test Procedure ................................................................................................................ 9 3.1.3 Test Setup ....................................................................................................................... 9 3.1.4 Test Result .................................................................................................................... 10 3.2 Radiated Emissions ............................................................................................. 12 3.2.1 Limit .............................................................................................................................. 12 3.2.2 Test Procedure .............................................................................................................. 12 3.2.3 Test Setup ..................................................................................................................... 13 3.2.4 Test Result .................................................................................................................... 14 3.3 20dB bandwidth measurement ............................................................................ 18 3.3.1 Test standard ................................................................................................................ 18 3.3.2 Test Procedure .............................................................................................................. 18 3.3.3 Test Setup ..................................................................................................................... 18 3.3.4 Test results .................................................................................................................... 18 HY- FCC part 15C Ver.1.1 Page 3 / 21 Report No.: RF251229036-01-001 4. Antenna Requirement ............................................................................. 20 Test Specification ...................................................................................................................... 20 HY- FCC part 15C Ver.1.1 Page 4 / 21 Report No.: RF251229036-01-001 History of this test report Original Report Issue Date: 2026.01.30 ● No additional attachment ○ Additional attachments were issued following record Attachment No. Issue Date Description HY- FCC part 15C Ver.1.1 Page 5 / 21 Report No.: RF251229036-01-001 1. General Information 1.1 Applicant jucani inc Suite A2, 7498 Colchester Court San Diego, California 92154 1.2 Manufacturer jucani inc Suite A2, 7498 Colchester Court San Diego, California 92154 1.3 Basic Description of Equipment Under Test Sample No. POC251229036-S001 Product name JUCANI Wireless Charging POWER BANK Model name PBE1020, PB-Elite-10K-20W Test model PBE1020 Model difference Only the model name and colors are different Trade mark Power supply: DC 5V from adapter or DC 3.85V from battery WPT Output Power: 15W Max/10W/7.5W/5W Modulation type ASK Operating frequency 111-205kHz Antenna type Coil Antenna Antenna Gain 0 dBi 1.4 Appli…
Text truncated - open the document above for the full version.
1.MECHANICA LDIMENSION (UNIT:mm) 2.SCH EMA TICS: 1.Coilwith magneticsheet attached,magnetic sheetdimensions 44 ± 1mm, OpentheL-line groove. 2.Coillead-out position Adhesivepaper1-2 tons; ABC D 2 EH 44 ± 1. 0 20.5 ± 0.5 0.3 ± 0.05 60 ± 3 3 ± 1.5 1.2 5 ± 3 3.WINDING : 1.1Bottom printedtext 100 STEPSTART-FINISHWIRETYPETURNS T A P E RE MA RK N1S-F Hotairductline ⌀ 0.08*24mm *2P2UEW 10TS (Ref) 4.ELECTRICAL SPECIFICATIO N: ITEMLDCRQpriceHI-POT TESTCOND Coilwithmagnetic sheet S-F 100KHz,0.25V AT25 °C SPEC6.3uH ± 10% 85m Ω Max 5.BILFOF MATERIAL : NO.ITEM MATERIAL SPECIFICATI ON MANUFACT URER SG S NO . 1 Hotairline0.08*24 strands Hotairline 0.08*24strands NANJINGJIN NINGCO,LTD 2Lead-freetinstripLead-freetinstripQIAODO 3magneticsheet ⌀ 44*0.5 Manganese-zinc hardmagnetic sheetwithL-slot opening TAIYI CO.,LTD 4glue YellowRubber 9999 LIANCHENG CO.,LTD 5 High-temperature adhesivetape 8mmwidehigh- temperature adhesivetape CUDAK CO.,LTD HRSWELECTRONICSCO.,LTD PAR TNO TITL E Applemagneticcoil G44withslots+60mm DRAWNBY CHECKED BY APPROVEDBY HeWeihuaWeiLihongWeiLihong 6.SAMPLETESTDATA 6.1DIMENSION TEST(UNIT:mm) TESTITEMABCDEH SPEC 44 ± 1.0 20.5 ± 0.5 0.3 ± 0.05 60 ± 3 3 ± 1.5 1.25 ± 3 1 43.8720.510.3160 3.501.27 2 43.8920.530.29960.01 3.601.26 3 43.9120.510.3260.08 3.701.29 4 43.9820.490.3159.9 3.801.29 5 43.9720.50.3260.01 4.001.23 6 7 8 9 10 MAX43.9820.530.32 60.0 8 4.001.29 MIN43.8720.490.30 59.9 0 3.501.23 AVERAGE43.9220.510.31 60.0 0 3.721.27 6.2ELECTRICALTEST TESTITEM LDCRIDC QHI-POT S-FS-F TESTCOND100KHz/0.25v AT25 °C SPEC 6.5uH ± 10% 85m Ω (Max) 16.5468.00 26.4967.00 36.3868.80 46.5167.90 56.4866.90 6 7 MAX6.5468.80 MIN6.3866.90 AVERAGE6.4867.72 HRSWELECTRONICSCO.,LTD PARTNO TITLE Apple magneticcoil G44withslots +60mm DRAWNBYCHECKEDBY APPROV EDBY HeWeihua Wei Lihong Wei Lihong
FCC ID: 2BTY9-PBE1020 Page 1 of 2 APPENDIX 1 PHOTOS OF TEST SETUP Radiated emission Test Setup (Below 30MHz) Radiated emission Test Setup (30MHz~1GHz) FCC ID: 2BTY9-PBE1020 Page 2 of 2 Conducted Emission Test Setup MPE
Suite A2,7498 Colchester Court · San Diego, California, 92154 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.111 MHz - 0.205 MHz | - |

JUCANI T038 pro Headphone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
JUCANI Headphone Z8
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Jucani Speaker-01
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter