Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 2026-05-29 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BV6WRB07A01, FCC ID: 2BV6WRB07C01, FCC ID: 2BV6WRB07CDOCK01 FRN: 0038437992 [FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Lin Yu Title: Certification Engineer Address: No. 2 Baohui Road, Yang’e Village, Lunjiao Street, Shunde, Foshan, Guangdong, China Tel.: +86 18825151523 Email: [email protected]
FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 2026-05-29 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BV6WRB07A01, FCC ID: 2BV6WRB07C01, FCC ID: 2BV6WRB07CDOCK01 FRN: 0038437992 [FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Lin Yu Title: Certification Engineer Address: No. 2 Baohui Road, Yang’e Village, Lunjiao Street, Shunde, Foshan, Guangdong, China Tel.: +86 18825151523 Email: [email protected]
TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 The following is a sample Agency Request letter, which needs to be completed on company letterhead, signed by an authorized Applicant/Agent, and submitted to TÜV Rheinland. Authority to Act as Agent Date: 2026-05-28 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TÜV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. / No. 2 Baohui Road, Yang’e Village, Lunjiao Street, Shunde, Foshan, Guangdong, China For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 2026-05-28 Agreement is valid for 12 months from the above date. By: __________________________ Lin Yu (Signature) (Print name) Certification Engineer +86 18825151523 (Title) (Telephone) On behalf of: FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. (Company Name)
FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. MS-0044715 Page 1 of 1 Revision 1 Date: 2026-05-29 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BV6WRB07A01, FCC ID: 2BV6WRB07C01, FCC ID: 2BV6WRB07CDOCK01 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC/IC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photos Short Term Permanent Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup Photos Short Term Permanent User’s Manual Short Term Permanent Part List FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of specify number of days not to exceed 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: _______________________________________________ _________Lin Yu_______________ (Signature/Title) (Print name) Tel.: +86 18825151523 Email: [email protected]
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN262URK 003 Auftrags-Nr.: Order no.: 27222188 Seite 1 von 10 Page 1 of 10 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2026-03-05 Auftraggeber: Client: FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. No. 2 Baohui Road, Yang’e Village, Lunjiao Street, Shunde, Foshan, Guangdong, China Prüfgegenstand: Test item: Robot Vacuum Cleaner Bezeichnung / Typ-Nr.: Identification / Type no.: RB07-C (Trademark: Dyson) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 2: Section 2.1091 RSS-102 Issue 6 December 2023 Wareneingangsdatum: Date of sample receipt: 2026-03-09 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004220759-008/009 Prüfzeitraum: Testing period: 2026-03-20 - 2026-04-02 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2026-05-28 Ausstellungsdatum: Issue date: 2026-05-28 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BV6WRB07C01 IC: 35617-RB07C01 HVIN: RB07-C Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Bell Hu Hardy Suo Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN262URK 003 Test report no.: Seite 2 von 10 Page 2 of 10 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel sieh…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN262URK 002 Auftrags-Nr.: Order no.: 27222188 Seite 1 von 23 Page 1 of 23 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2026-03-05 Auftraggeber: Client: FOSHAN SILVER STAR INTELLIGENT MANUFACTURING CO., LTD. No. 2 Baohui Road, Yang’e Village, Lunjiao Street, Shunde, Foshan, Guangdong, China Prüfgegenstand: Test item: Robot Vacuum Cleaner Bezeichnung / Typ-Nr.: Identification / Type no.: RB07-C (Trademark: Dyson) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15: Subpart C Section 15.247 RSS-247 Issue 4 July 2025 RSS-Gen Issue 5 February 2021 Wareneingangsdatum: Date of sample receipt: 2026-03-09 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004220759-007/008/009 Prüfzeitraum: Testing period: 2026-03-18 - 2026-04-02 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X genehmigt von: authorized by: X Datum: Date: 2026-05-28 Ausstellungsdatum: Issue date: 2026-05-28 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BV6WRB07C01 IC: 35617-RB07C01 HVIN: RB07-C Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Bell Hu Hardy Suo Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN262URK 002 Test report no.: Seite 2 von 23 Page 2 of 23 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Ri…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix B CN262URK 002 Page 33 of 95 Occupied Channel Bandwidth 99% (2452 MHz; 30.000 dBm; 11n_40 MHz) 99 % Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2452.000000 37.500000 --- --- 2433.125000 2470.625000 (continuation of the "99 % Bandwidth" table from column 6 ...) DUT Frequency (MHz) Result 2452.000000 PASS Measurement Setting Instrument Value Target Value Start Frequency 2.41200 GHz 2.41200 GHz Stop Frequency 2.49200 GHz 2.49200 GHz Span 80.000 MHz 80.000 MHz RBW 500.000 kHz >= 400.000 kHz VBW 2.000 MHz >= 1.500 MHz SweepPoints 320 ~ 320 Sweeptime 1.000 ms AUTO Reference Level 10.000 dBm 10.000 dBm Attenuation 30.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 100 100 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype Sweep AUTO Preamp off off Stablemode Trace Trace Stablevalue 0.30 dB 0.30 dB Run 67 / max. 150 max. 150 Stable 3 / 3 3 Max Stable Difference 0.00 dB 0.30 dB -30 -20 -10 0 10 15 24122420 2440 2460 2480 2492 Level in dBm Frequency in MHz 99 % Bandwidth 37.500 MHz Prüfbericht - Produkte Test Report - Products Appendix B CN262URK 002 Page 34 of 95 Wi-Fi 802.11 ax(HE20) mode Occupied Channel Bandwidth 99% (2412 MHz; 30.000 dBm; 11ax20MHz) 99 % Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2412.000000 19.200000 --- --- 2402.350000 2421.550000 (continuation of the "99 % Bandwidth" table from column 6 ...) DUT Frequency (MHz) Result 2412.000000 PASS Measurement Setting Instrument Value Target Value Start Frequency 2.39200 GHz 2.39200 GHz Stop Frequency 2.43200 GHz 2.43200 GHz Span 40.000 MHz 40.000 MHz RBW 200.000 kHz >= 200.000 kHz VBW 1.000 MHz >= 600.000 kHz SweepPoints 400 ~ 400 Sweeptime 47.266 μs AUTO Reference Level 10.000 dBm 10.000 dBm Attenuation 30.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 100 100 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype FFT AUTO Preamp off off Stablemode Trace Trace Stablevalue 0.30 dB 0.30 dB Run 67 / max. 150 max. 150 Stable 3 / 3 3 Max Stable Difference 0.00 dB 0.30 dB -30 -20 -10 0 10 15 2392 2400 2410 2420 2432 Level in dBm Frequency in MHz 99 % Bandwidth 19.200 MHz Prüfbericht - Produkte Test Report - Products Appendix B CN262URK 002 Page 35 of 95 Occupied Channel Bandwidth 99% (2437 MHz; 30.000 dBm; 11ax20MHz) 99 % Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2437.000000 19.100000 --- --- 2427.450000 2446.550000 (continuation of the "99 % Bandwidth" table from column 6 ...) DUT Frequency (MHz) Result 2437.000000 PASS Measurement Setting Instrument Value Target Value Start Frequency 2.41700 GHz 2.41700 GHz Stop Frequency 2.45700 GHz 2.45700 GHz Span 40.000 MHz 40.000 MHz RBW 200.000 kHz >= 200.000 kHz VBW 1.000 MHz >= 600.000 kHz SweepPoints 400 ~ 400 Sweeptime 47.266 μs AUTO Reference Level 10.000 dBm 10.000 dBm Attenuation 30.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 100 100 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype FFT AUTO Preamp off off Stablemode Trace Trace Stablevalue 0.30 dB 0.30 dB Run 83 / max. 150 max. 150 Stable 3 / 3 3 Max Stable Difference 0.00 dB 0.30 dB -30 -20 -10 0 10 15 2417 2430 2440 2450 2457 Level in dBm Frequency in MHz 99 % Bandwidth 19.100 MHz Prüfbericht - Produkte Test Report - Products Appendix B CN262URK 002 Page 36 of 95 Occupied Channel Bandwidth 99% (2462 MHz; 30.000 dBm; 11ax20MHz) 99 % Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2462.000000 19.200000 --- --- 2452.350000 2471.550000 (continuation of the "99 % Bandwidth" table from column 6 ...) DUT Frequency (MHz) Result 2462.000000 PASS Measurement Setting Instrument Value Target Value Start Frequency 2.44200 GHz 2.44200 GHz Stop Frequency 2.48200 GHz 2.48200 GHz Span 40.000 MHz 40.000 MHz RBW 200.000 kHz >= 200.000 kHz VBW 1.000 MHz >= 600.000 kHz SweepPoints 400 ~ 400 Sweeptime 47.266 μs AUTO Reference Level 10.000 dBm 10.000 dBm Attenuation 30.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 100 100 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype FFT AUTO Preamp off off Stablemode Trace Trace Stablevalue 0.30 dB 0.30 dB Run 77 / max. 150 max. 150 Stable 3 / 3 3 Max Stable Difference 0.11 dB 0.30 dB -30 -20 -10 0 10 15 2442 2450 2460 2470 2482 Level in dBm Frequency in MHz 99 % Bandwidth 19.200 MHz Prüfbericht - Produkte Test Report - Products Appendix B CN262URK 002 Page 37 of 95 Wi-Fi 802.11 ax(HE40) mode Occupied Channel Bandwidth 99% (2422 MHz; 30.000 dBm; 11ax40MHz) 99 % Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2422.000000 38.250000 --- --- 2402.875000 2441.125000 (continuation of the "99 % Bandwidth" table from column 6 ...) DUT Frequency (MHz) Result 2422.000000 PASS Measurement Setting Instrument Value Target Value Start Frequency 2.38200 GHz 2.38200 GHz Stop Frequency 2.46200 GHz 2.46200 GHz Span 80.000 MHz 80.000 MHz RBW 500.000 kHz >= 400.000 kHz VBW 2.000 MHz >= 1.500 MHz SweepPoints 320 ~ 320 Sweeptime 1.000 ms AUTO Reference Level 10.000 dBm 10.000 dBm Attenuation 30.000 dB AUTO Detector MaxPeak MaxPeak SweepCount 100 100 Filter 3 dB 3 dB Trace Mode Max Hold Max Hold Sweeptype Sweep AUTO Preamp off off Stablemode Trace Trace Stablevalue 0.30 dB 0.30 dB Run 71 / max. 150 max. 150 Stable 3 / 3 3 Max Stable Difference 0.00 dB 0.30 dB -30 -20 -10 0 10 15 2382 2400 2420 2440 2462 Level in dBm Frequency in MHz 99 % Bandwidth 38.250 MHz Prüfbericht - Produkte Test Report - Products Appendix B CN262URK 002 Page 38 of 95 Occupied Channel Bandwidth 99% (2437 MHz; 30.000 dBm; 11ax40MHz) 99 % Bandwidth DUT Frequency (MHz) Bandwidth (MHz) Limit Min (MHz) Limit Max (MHz) Band Edge Left (MHz) Band Edge Right (MHz) 2437.000000 38.250000 --- --- 2417.875000 2456.125000 (continuation …
Text truncated - open the document above for the full version.
1 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 承认书 客户名称:银星 机种名称:914/914A 睿德料号: RD1822501NB87-1 版本号:V2.0 研发结构:刘齐富 研发射频:陈锐 批准:帅凯成 生效日期:2025年11月24日 客户审核: 客户批准: 生效日期: 深圳市南山区沙河西路3011号白沙科技产业园3楼B区 电话 :0755-26625028 传 真:0755-26624118 2 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 目录 1承认书封面 2承认书目录 3修改记录 4规格参数 5性能数据 6结构图纸 3 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 修改记录 RevisionDate Change Notification Description R:A 2025.10.27 初版 R:B 2025.11.24 第二版 R:C2026.3.4第三版 4 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 规格参数 1.ElectricalCharacteristics Frequency 2400-2500MHz SWR <2.0 Polarizationvertical Impedance 50Ohm 2.Material&MechanicalCharacteristics MaterialofRadiator PCB MaterialofPlasticPCB CableType OD1.13mm ConnectorType Cable+Plug 3.Environmental OperationTemperature -40°C~+65°C StorageTemperature -40°C~+80°C AntennaColorStoragelife<2year 4 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 天线图片 : 天线装配示意图: 7 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 性能数据 Freq(MHz)Efficiency(%)Efficiency(dB) Gain(dBi) 2400 50%-3.003.55 2410 48%-3.213.25 2420 47%-3.323.22 2430 46%-3.333.35 2440 46%-3.393.39 2450 46%-3.363.41 2460 45%-3.453.28 2470 45%-3.503.13 2480 45%-3.453.08 2490 45%-3.482.96 2500 45%-3.482.91 7 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. OTA有源数据 ZW32静态 2.4GB模11M 1 713 TRP 17.7817.8518.03 TIS -81.5-82.63-81.86 2.4GG模 TRP(6M 17.7117.7117.83 TIS(54M -68.46-69.79-68.96 2.4GN模 TRP(dBm)(MCS0) 17.717.717.81 TIS(MCS7 -66.2-67.06-66.96 动态 2.4GB模11M 1713 TRP 17.8317.8418.01 TIS -68.11-69.42-69.15 2.4GG模 TRP(6M 17.7317.6617.75 TIS(54M -60.26-63.29-59.81 2.4GN模 TRP(dBm)(MCS0) 17.6817.6417.72 TIS(MCS7 -63.27-64.53-59.37 7 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. OTA有源数据 PS31 静态 2.4GB模11M 2.4GB模11M1713 TRP 17.4417.3817.56 TIS -81.27-80.98-81.25 2.4GG模 TRP(6M 17.11717.1 TIS(54M -65.44-66.16-66.82 2.4GN模 TRP(dBm)(MCS0) 17.116.9917.1 TIS(MCS7 -65.45-65.89-66.43 动态 2.4GB模11M 1713 TRP 17.4717.4517.61 TIS -72.21-71.89-70.89 2.4GG模 TRP(6M 17.1216.9217.07 TIS(54M -64.28-64.88-63.8 2.4GN模 TRP(MCS0) 17.0716.9617.06 TIS(MCS7 -62.5-63.21-63.6 7 ETHET 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. S11logMag/Smith参数 7 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 2D图 7 深圳市睿德通讯科技有限公司 ShenzhenEthetaCommunicationTechnologyCo.,LTD. 3D图
1435 Arapahoe Ave Boulder CO 80302 · Boulder, Colorado, 80302 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.40 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 264.90 mW |
| 3 | 15C | 2.42 GHz - 2.45 GHz | 103.80 mW |