Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
SHARE3DCAM S30 PRO User Manual V1.0 2026.04 SHARE3DCAM LIMITED Disclaimer and Warning The copyright of this document and all other collateral documents belong to SHARE3DCAM LIMITED (abbreviated as “SHARE3DCAM ”). SHARE3DCAM has the final interpretation right of this document and all other collateral documents. By using SHARE3DCAM products, user agree to SHARE3DCAM 's relevant disclaimer terms SHARE3DCAM has right to update, modify or terminate the content of this document without prior notice. For update information, visit website “www.SHARE3DCAM.com” and click on the product page for this product. This product is not a toy. Do not allow people under the age of 18 to touch or use the SHARE3DCAM S30 PRO handheld LiDAR device . Do not modify or disassemble the SHARE3DCAM S30 PRO handheld LiDAR device. The user shall bear full responsibility for any product malfunctions, safety incidents, or economic losses resulting from self-disassembly, modification, or alteration of the product. Please read and understand the operating documents and precautions carefully before installing, setting up and using this product, and understand user's legal rights, responsibilities and safety instructions; otherwise, SHARE3DCAM has the right to exempt itself from any responsibility and incidental liability for safety issues and property losses caused by failure to accurately understand the product safety use rules. Before using the product, users have promised to be responsible for their own actions and all consequences arising therefrom. The user agrees to use this product for legitimate purposes and accepts these terms and all applicable laws and regulations established by national authorities pertaining to this product. To the maximum extent permitted by law, in no case shall SHARE3DCAM be liable for any indirect, consequential, punitive, incidental, special or punitive damages, including liability for losses suffered due to user's purchase, use or inability to use this product (even if SHARE3DCAM has been informed of the possibility of such loss). Please use this product in compliance with the relevant national laws and regulations on drones and related products. SHARE3DCAM does not assume any responsibility for any consequences of using this product in violation of relevant national laws and regulations, including but not limited to legal disputes, civil liability, criminal liability, economic losses, etc. Catalog 1 Product Overview .................................................................... 1 1.1 Product Introduction .......................................................... 1 1.2 Features ............................................................................. 1 1.3 In the Box ........................................................................... 3 1.4 Product Parameter ............................................................. 3 2 Installation ............................................................................... 7 2.1 Device Components ........................................................... 7 2.2 Installation ......................................................................... 1 2.3 Disassembly ........................................................................ 2 2.4 Charge ................................................................................ 3 3 Scanning Operation ................................................................. 4 3.1 Power On ........................................................................... 8 3.2 Device Starting Up .............................................................. 8 3.3 Device Connect Mobile APP ............................................... 8 3.4 Start Scanning .................................................................. 11 3.5 Parameter Setting ............................................................ 12 3.6 New Project ...................................................................... 14 3.7 Control Point Collection ................................................... 17 3.8 Data Collection ................................................................. 19 3.9 Data Saving ....................................................................... 21 3.10 Power Off ....................................................................... 21 4 SHARE Capture Data Manager ............................................... 22 4.1 Data Storage ..................................................................... 22 4.2 Local ................................................................................. 24 4.3 Review Data ..................................................................... 25 5 SHARE PointClouds Studio ..................................................... 26 5.1 Software Configuration Requirements ............................ 26 5.2 Data Processing ................................................................ 27 6 Device Maintenance .............................................................. 30 6.1 Precaution ........................................................................ 30 7 After Sales .............................................................................. 32 7.1 Shipment .......................................................................... 32 7.2 After-sales Service ............................................................ 33 1 1 Product Overview 1.1 Product Introduction SHARE3DCAM S30 PRO is a handheld 3D LiDAR scanner designed and developed by SHARE3DCAM. It integrates high- precision LiDAR, surveying, mapping wide-angle camera and built-in RTK module. It deeply integrates LiDAR and image, and cooperates with self-developed point cloud algorithm. Single person operation can obtain accurate color point cloud data by scanning with a SHARE3DCAM S30 PRO , which complete spatial mapping in a short time. Whether they are architectural designers, construction workers or surveying professionals, they can quickly obtain real-scene 3D information by using …
Text truncated - open the document above for the full version.
SHARE3DCAM LIMITED Room 3502, Yuehai Landmark Building, No. 2018, Buxin Road, Dongxiao Community, Dongxiao Sub-district, Luohu District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/05/06 U.S. Agent Designation SHARE3DCAM LIMITED acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BVWM-S30PRO): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Phone of U.S. agent: (626) 588-8039 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of SHARE3DCAM LIMITED with the FRN [0038358826] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature Hongpeng Yan Manager SHARE3DCAM LIMITED Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID: 2BVWM-S30PRO External Photos of the EUT FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO
Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BVWM-S30PRO
FCC ID: 2BVWM-S30PRO Internal Photos of the EUT FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO GNSS ANT FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO WIFI ANT 2 BT/WIFI ANT 1 FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO FCC ID: 2BVWM-S30PRO
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure MPE Report Reference No. ..................... : FCC ID............................................. : CTA26040800504 2BVWM-S30PRO Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Apr. 30, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : SHARE3DCAM LIMITED Address............................................ : Room 3502, Yuehai Landmark Building, No. 2018, Buxin Road, Dongxiao Community, Dongxiao Sub-district, Luohu District, Shenzhen, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Real-Scene 3D LiDAR Scanner Trade Mark ....................................... : SHARE3DCAM Manufacturer .................................... : SHARE3DCAM LIMITED Model/Type reference ...................... : SHARE3DCAM S30 PRO Listed Models ................................... : N/A Rating ............................................... : Input: 20V1.5A Battery: 14.4V 3150mAh 45.36Wh Result ............................................... : PASS Report No.: CTA26040800504 Page 2 of 11 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Real-Scene 3D LiDAR Scanner Model /Type : SHARE3DCAM S30 PRO Applicant : SHARE3DCAM LIMITED Address : Room 3502, Yuehai Landmark Building, No. 2018, Buxin Road, Dongxiao Community, Dongxiao Sub-district, Luohu District, Shenzhen, China Manufacturer : SHARE3DCAM LIMITED Address : Room 3502, Yuehai Landmark Building, No. 2018, Buxin Road, Dongxiao Community, Dongxiao Sub-district, Luohu District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26040800504 Page 3 of 11 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 6 2.4 Modifications ............................................................................................................ 6 3 TEST ENVIRONMENT ....................................................................................................... 7 3.1 Address of the test laboratory .................................................................................. 7 3.2 Test Facility .............................................................................................................. 7 3.3 Statement of the measurement uncertainty ............................................................. 7 4 Test limit .............................................................................................................................. 8 4.1 Requirement ............................................................................................................ 8 4.2 MPE Calculation Method ......................................................................................... 8 4.3 Conducted Power Results ....................................................................................... 9 4.4 Manufacturing tolerance ........................................................................................ 10 4.5 Standalone MPE Result ......................................................................................... 11 4.6 Simultaneous Transmission for MPE Result ......................................................... 11 5 Conclusion ......................................................................................................................... 11 Report No.: CTA26040800504 Page 4 of 11 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou…
Text truncated - open the document above for the full version.
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. ........................................... : CTA26040800501 2BVWM-S30PRO Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Apr. 30, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : SHARE3DCAM LIMITED Address ............................................ : Room 3502, Yuehai Landmark Building, No. 2018, Buxin Road, Dongxiao Community, Dongxiao Sub-district, Luohu District, Shenzhen, China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Real-Scene 3D LiDAR Scanner Trade Mark ....................................... : SHARE3DCAM Manufacturer .................................... : SHARE3DCAM LIMITED Model/Type reference ...................... : SHARE3DCAM S30 PRO Listed Models ................................... : N/A Modulation ....................................... : GFSK, Π/4DQPSK, 8DPSK Frequency ........................................ : From 2402MHz to 2480MHz Ratings ............................................. : Input: 20V1.5A Battery: 14.4V 3150mAh 45.36Wh Result ............................................... : PASS Report No.: CTA26040800501 Page 2 of 51 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Real-Scene 3D LiDAR Scanner Model /Type : SHARE3DCAM S30 PRO Applicant : SHARE3DCAM LIMITED Address : Room 3502, Yuehai Landmark Building, No. 2018, Buxin Road, Dongxiao Community, Dongxiao Sub-district, Luohu District, Shenzhen, China Manufacturer : SHARE3DCAM LIMITED Address : Room 3502, Yuehai Landmark Building, No. 2018, Buxin Road, Dongxiao Community, Dongxiao Sub-district, Luohu District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26040800501 Page 3 of 51 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description ........................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 6 2.6 EUT operation mode ......................................................................................................................... 6 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 6 3.1 Address of the test laboratory ........................................................................................................... 6 3.2 Test Facility........................................................................................................................................ 7 3.3 Environmental conditions ......................................................................................…
Text truncated - open the document above for the full version.
Report No.: CTA26040800501 Page 47 of 51 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Report No.: CTA26040800501 Page 48 of 51 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Report No.: CTA26040800501 Page 49 of 51 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Report No.: CTA26040800501 Page 50 of 51 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Report No.: CTA26040800501 Page 51 of 51 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn ......................End of Report........................
1 FCC Appendix RF Test Data for BT FCC ID : 2BVWM-S30PRO Company : SHARE3DCAM LIMITED EUT : Real-Scene 3D LiDAR Scanner Model Number : SHARE3DCAM S30 PRO Report No. : CTA26040800501 Reviewed By : Eric Wang 2 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Freq(MHz) 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.960 2401.547 2402.507 --- --- 2441 0.942 2440.553 2441.495 --- --- 2480 0.930 2479.550 2480.480 --- --- 2DH5 Ant1 2402 1.335 2401.346 2402.681 --- --- 2441 1.359 2440.331 2441.690 --- --- 2480 1.332 2479.340 2480.672 --- --- 3DH5 Ant1 2402 1.284 2401.367 2402.651 --- --- 2441 1.293 2440.367 2441.660 --- --- 2480 1.287 2479.367 2480.654 --- --- 3 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 4 2DH5_Ant1_2402 2DH5_Ant1_2441 5 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 6 3DH5_Ant1_2480 7 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.86712 2401.5784 2402.4455 --- --- 2441 0.88579 2440.5743 2441.4600 --- --- 2480 0.86471 2479.5764 2480.4411 --- --- 2DH5 Ant1 2402 1.1912 2401.4149 2402.6061 --- --- 2441 1.1886 2440.4163 2441.6049 --- --- 2480 1.1818 2479.4202 2480.6020 --- --- 3DH5 Ant1 2402 1.1942 2401.4135 2402.6077 --- --- 2441 1.1866 2440.4204 2441.6070 --- --- 2480 1.1988 2479.4122 2480.6110 --- --- 8 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 9 2DH5_Ant1_2402 2DH5_Ant1_2441 10 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 11 3DH5_Ant1_2480 12 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 -2.63 ≤20.97 PASS 2441 -2.88 ≤20.97 PASS 2480 -2.95 ≤20.97 PASS 2DH5 Ant1 2402 -3.40 ≤20.97 PASS 2441 -3.72 ≤20.97 PASS 2480 -3.87 ≤20.97 PASS 3DH5 Ant1 2402 -3.18 ≤20.97 PASS 2441 -3.43 ≤20.97 PASS 2480 -3.48 ≤20.97 PASS 13 Appendix D: Carrier frequency separation Test Result TestMode Antenna Freq(MHz) Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 0.956 ≥0.640 PASS 2DH5 Ant1 Hop 1.106 ≥0.906 PASS 3DH5 Ant1 Hop 0.944 ≥0.862 PASS 14 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 15 16 Appendix E: Time of occupancy Test Result TestMode Antenna Freq(MHz) BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH1 Ant1 Hop 0.408 319 0.13 ≤0.4 PASS DH3 Ant1 Hop 1.663 164 0.273 ≤0.4 PASS DH5 Ant1 Hop 2.912 106 0.309 ≤0.4 PASS 2DH1 Ant1 Hop 0.418 316 0.132 ≤0.4 PASS 2DH3 Ant1 Hop 1.668 151 0.252 ≤0.4 PASS 2DH5 Ant1 Hop 2.916 110 0.321 ≤0.4 PASS 3DH1 Ant1 Hop 0.415 318 0.132 ≤0.4 PASS 3DH3 Ant1 Hop 1.664 157 0.261 ≤0.4 PASS 3DH5 Ant1 Hop 2.918 105 0.306 ≤0.4 PASS 17 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop 18 DH5_Ant1_Hop 19 2DH1_Ant1_Hop 2DH3_Ant1_Hop 20 2DH5_Ant1_Hop 21 3DH1_Ant1_Hop 3DH3_Ant1_Hop 22 3DH5_Ant1_Hop 23 24 Appendix F: Number of hopping channels Test Result TestMode Antenna Freq(MHz) Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 3DH5 Ant1 Hop 79 ≥15 PASS 25 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop 26 27 Appendix G: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 -3.19 -57.77 ≤-23.19 PASS High 2480 -3.56 -57.27 ≤-23.56 PASS Low Hop_2402 -10.25 -57.76 ≤-30.25 PASS High Hop_2480 -9.65 -57.05 ≤-29.65 PASS 2DH5 Ant1 Low 2402 -6.02 -57.53 ≤-26.02 PASS High 2480 -7.40 -57.49 ≤-27.4 PASS Low Hop_2402 -13.32 -57.42 ≤-33.32 PASS High Hop_2480 -12.62 -57.25 ≤-32.62 PASS 3DH5 Ant1 Low 2402 -8.81 -57.29 ≤-28.81 PASS High 2480 -6.79 -57.21 ≤-26.79 PASS Low Hop_2402 -10.89 -57.44 ≤-30.89 PASS High Hop_2480 -11.02 -56.87 ≤-31.02 PASS 28 Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 29 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 30 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 31 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 32 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 33 Appendix H: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference -4.00 -4.00 --- PASS 30~1000 -4.00 -67.45 ≤-24 PASS 1000~26500 -4.00 -46.67 ≤-24 PASS 2441 Reference -3.95 -3.95 --- PASS 30~1000 -3.95 -68.07 ≤-23.95 PASS 1000~26500 -3.95 -47.38 ≤-23.95 PASS 2480 Reference -3.59 -3.59 --- PASS 30~1000 -3.59 -68.17 ≤-23.59 PASS 1000~26500 -3.59 -47.04 ≤-23.59 PASS 2DH5 Ant1 2402 Reference -7.21 -7.21 --- PASS 30~1000 -7.21 -68 ≤-27.21 PASS 1000~26500 -7.21 -52.84 ≤-27.21 PASS 2441 Reference -8.61 -8.61 --- PASS 30~1000 -8.61 -67.51 ≤-28.61 PASS 1000~26500 -8.61 -52.91 ≤-28.61 PASS 2480 Reference -7.85 -7.85 --- PASS 30~1000 -7.85 -67.8 ≤-27.85 PASS 1000~26500 -7.85 -53.85 ≤-27.85 PASS 3DH5 Ant1 2402 Reference -7.16 -7.16 --- PASS 30~1000 -7.16 -67.81 ≤-27.16 PASS 1000~26500 -7.16 -52.42 ≤-27.16 PASS 2441 Reference -7.71 -7.71 --- PASS 30~1000 -7.71 -66.79 ≤-27.71 PASS 1000~26500 -7.71 -53.39 ≤-27.71 PASS 2480 Reference -9.39 -9.39 --- PASS 30~1000 -9.39 -68.25 ≤-29.39 PASS 1000~26500 -9.39 -53.98 ≤-29.39 PASS 34 Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 35 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 36 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 37 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference 38 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference
39 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 40 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 41 3DH5_Ant1_2402_0~Reference 3DH5_Ant1_2402_30~1000 42 3DH5_Ant1_2402_1000~26500 3DH5_Ant1_2441_0~Reference 3DH5_Ant1_2441_30~1000 43 3DH5_Ant1_2441_1000~26500 3DH5_Ant1_2480_0~Reference 44 3DH5_Ant1_2480_30~1000 3DH5_Ant1_2480_1000~26500 45 Appendix I: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] DC [%] xFactor Limit Verdict DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 2DH5 Ant1 2402 2.92 3.76 77.66 1.10 --- --- 2441 2.92 3.74 78.07 1.08 --- --- 2480 2.92 3.75 77.87 1.09 --- --- 3DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 46 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 47 2DH5_Ant1_2402 2DH5_Ant1_2441 48 2DH5_Ant1_2480 3DH5_Ant1_2402 3DH5_Ant1_2441 49 3DH5_Ant1_2480 50 Appendix J: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict DH5 Ant1 Low 2402 AV 2310.000 -59.95 2.00 1.10 38.35 ≤54 PASS AV 2384.945 -58.34 2.00 1.10 39.96 ≤54 PASS AV 2390.000 -59.29 2.00 1.10 39.01 ≤54 PASS Peak 2310.000 -50.58 2.00 0.00 46.62 ≤74 PASS Peak 2357.330 -48.16 2.00 0.00 49.04 ≤74 PASS Peak 2390.000 -49.46 2.00 0.00 47.74 ≤74 PASS High 2480 AV 2483.500 -57.72 2.00 1.10 40.58 ≤54 PASS AV 2483.600 -57.54 2.00 1.10 40.76 ≤54 PASS AV 2500.000 -58.58 2.00 1.10 39.72 ≤54 PASS Peak 2483.500 -49.96 2.00 0.00 47.24 ≤74 PASS Peak 2495.360 -48.46 2.00 0.00 48.74 ≤74 PASS Peak 2500.000 -51.85 2.00 0.00 45.35 ≤74 PASS 2DH5 Ant1 Low 2402 AV 2310.000 -59.74 2.00 1.10 38.56 ≤54 PASS AV 2369.195 -58.36 2.00 1.10 39.94 ≤54 PASS AV 2390.000 -59.51 2.00 1.10 38.79 ≤54 PASS Peak 2310.000 -51.33 2.00 0.00 45.87 ≤74 PASS Peak 2374.340 -48.31 2.00 0.00 48.89 ≤74 PASS Peak 2390.000 -50.6 2.00 0.00 46.60 ≤74 PASS High 2480 AV 2483.500 -58.89 2.00 1.09 39.40 ≤54 PASS AV 2484.080 -58.06 2.00 1.09 40.23 ≤54 PASS AV 2500.000 -58.81 2.00 1.09 39.48 ≤54 PASS Peak 2483.500 -49.02 2.00 0.00 48.18 ≤74 PASS Peak 2498.640 -47.13 2.00 0.00 50.07 ≤74 PASS Peak 2500.000 -50.16 2.00 0.00 47.04 ≤74 PASS 3DH5 Ant1 Low 2402 AV 2310.000 -59.84 2.00 1.10 38.46 ≤54 PASS AV 2374.970 -58.47 2.00 1.10 39.83 ≤54 PASS AV 2390.000 -59.44 2.00 1.10 38.86 ≤54 PASS Peak 2310.000 -52.38 2.00 0.00 44.82 ≤74 PASS Peak 2342.420 -48.24 2.00 0.00 48.96 ≤74 PASS Peak 2390.000 -52.4 2.00 0.00 44.80 ≤74 PASS High 2480 AV 2483.500 -…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |

Real-Scene 3D LiDAR Scanner
Equipment Class
DTS - Digital Transmission System