FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nube iO/
  3. 2BVYH-DR07N1

2BVYH-DR07N1Droplet Gen2

Nube iO
Droplet Gen2 - FCC ID 2BVYH-DR07N1 - Nube iO
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Sep 11, 2026
Application Purpose
Original Equipment
Equipment Note
Droplet Gen2
Frequency Range
902.30000000 - 914.90000000
Company
Nube iO
Country
Australia

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Droplet Gen2 Technical Data General Model Number DR-07-N1 - Base Model (Customisable/OEM Variants available). Dimensions 120mm × 40mm × 40mm or 4.72 in × 1.57 in × 1.57 in Power Supply Type: 3.6V Lithium-ion cell battery Expected Battery Life: 5-10 years pending the configured push rate Power Consumption Active current consumption: < 8 mA (typical) Sleep current: < 10 uA LoRa Push current: ~120mA for up to 1.5 seconds Data Push Rate COV and interval: The interval can be configured from 15 minutes to 60 minutes. IP Rating IP20 (Indoor Use) Operating Temperature –20 °C to 70 °C Storage Temperature –20 °C to 70 °C (battery disconnected) Operating Relative Humidity 5% to 95% (non-condensing) Material type Injection-molded ABS (UL94 V-1), white finish (HEX #FFFFFF. R: 255 G: 255 H: 255). Droplet V2 - Datasheet - Nube iO | 1 Droplet Gen2 by Nube iO is the next evolution of our industry-leading wireless LoRa® IoT sensor, engineered to capture accurate Temperature and Humidity data with greater reliability and performance than previous generations. Designed as a surface-mount, fully wireless device, Droplet Gen2 eliminates the need for physical sensor wiring, significantly reducing installation time, labour costs, and disruption for building occupants. Built on our enhanced Gen2 architecture, the Droplet leverages LoRa® technology to deliver a robust transmission range, energy efficiency, and minimal susceptibility to object interference compared to other wireless technologies. These advancements make Droplet Gen2 an ideal choice for monitoring, controlling, and optimising various spaces. Compliance & Certification CE (Europe): EN 300 220-2 (LoRa in 868 MHz band), EN 301 489 (EMC), EN 62368 (safety). FCC (USA): 47 CFR Part 15 C (915 MHz), FCC Part 15 B (EMC). IC (Canada): RSS-247 (LoRa), RSS-Gen (EMC). RoHS & REACH: All components compliant. (Battery Excluded) Wireless Communications LoRa® Supported Frequencies: AU923, US915, AS923, EU863 Spreading Factor: 7-12 Bandwidth: 125 kHz, 250 kHz and 500 kHz Peripheral Sensors Temperature Sensing Range: –40°C to 85°C Accuracy: ±0.2 °C Humidity Sensing Range: 0% to 100% Accuracy: ±2% RH About Nube iO At Nube iO, we make buildings smarter. From enterprise and industrial portfolios to light commercial and smart homes, our scalable, data-driven technology bridges BMS and IoT to connect devices, systems, and spaces - giving users simpler control, clearer visibility, and more sustainable operations. Built to scale from single sites to entire portfolios, our ecosystem — including traditional controls, wireless sensors, protocol-ready gateways and licence-free programming software — delivers seamless integration and efficient automation across diverse environments. Backed by global expertise and a commitment to continuous innovation, we make building automation smarter, simpler, and future-ready. Smarter Buildings. Forward Thinking. Unlock smarter, more sustainable building operations — book a demo at nube-io.com Document Code DR-2606 Person Responsible BTJ Date Last Updated 05/12/2025 Status Revision 3.0 Location Certification Gen 2/Documents_for_Certification Droplet V2 - Datasheet - Nube iO | 2 Revision Date Description Rev.1 05/12/2025 For Certification Rev.2 11/12/2025 Lora Frequencies Updated and about product updated Rev.3 17/06/2026 Operating Temperature and sensing temperature updated Droplet V2 - Datasheet - Nube iO | 3 FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.

Attestation Statements

Rev 1/26/2023 Nube iO Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-08-26 FCC ID: 2BVYH-DR07N1 Ref. #1: Attestation Statements Part 2.911(d)(5)(i) Filing Nube iO certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Nube iO certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Ref. #2: Attestation Statements Part 2.911(d)(5)(ii) Filing Nube iO certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Applicant: Nube iO Address: 1/17 Cemetery Rd, Helensburgh, NSW 2508, Australia Contact Person: Hoai Hoang Tel.: +61 2 7906 8414 Email: [email protected] Sincerely, Signature:

Attestation Statements

Attestation Statements Date: 2026-08-26 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for(FCC ID: 2BVYH-DR07N1) Nube iO, the undersigned, hereby authorize FCC US Agent, LLC to act as our designated agent for service of process, Nube iO accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. FCC US Agent, LLC accepts the responsibility to act as designated agent for service of process. Applicant Information: Company name: Nube iO Contact Name: Hoai Hoang Address: 1/17 Cemetery Rd, Helensburgh, NSW 2508, Australia Telephone No: +61 2 7906 8414 Email: [email protected] FRN: 0038385738 Signature: Hoai Hoang Agent Information: Company Name: FCC US Agent, LLC Address:3722 Illinois Avenue, Saint Charles, IL, 60174, USA FRN: 0033402884 Contact Name: Tim Payne Telephone No: 708-571-3148 Email: [email protected] Signature: Tim Payne

Cover Letter(s)

Nube iO Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: August 26, 2026 Subject; Request for Confidentiality FCC ID: 2BVYH-DR07N1 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Hoai Hoang Title: Lead Hardware Design

Cover Letter(s)

Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Nube iO Date:2026-08-26 Product Model Number: DR-07-N1 FCC ID:2BVYH-DR07N1 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. Signature: By: Hoai Hoang Contact Listed on FCC Wesbite Title: Lead Hardware Design Email: [email protected] On behalf of: Nube iO

External Photos

Page 1 of 3 Report No.: LGT25L401 Appendix - External Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 3 Report No.: LGT25L401 Appendix - External Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 3 Report No.: LGT25L401 Appendix - External Photographs of EUT Constructional Details Photo 5 Photo 6

ID Label/Location Info

Label Size: 11mm*32mm FCC ID: 2BVYH-DR07N1

Internal Photos

Page 1 of 4 Report No.: LGT25L401 Appendix - Internal Photographs of EUT Constructional Details Photo 1 Photo 2 Page 2 of 4 Report No.: LGT25L401 Appendix - Internal Photographs of EUT Constructional Details Photo 3 Photo 4 Page 3 of 4 Report No.: LGT25L401 Appendix - Internal Photographs of EUT Constructional Details Photo 5 Photo 6 Page 4 of 4 Report No.: LGT25L401 Appendix - Internal Photographs of EUT Constructional Details Photo 7 Photo 8 ANT

RF Exposure Info

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 8 EMF TEST REPORT Product Name: Droplet Gen2 Model Number: DR-07-N1 FCC ID: 2BVYH-DR07N1 Issued For : Nube iO 1/17 Cemetery Rd, Helensburgh, NSW 2508, Australia Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25L401HA02 Sample Received Date: Dec. 22, 2025 Date of Test: Dec. 22, 2025 ~ Jul. 14, 2026 Date of Issue: Jul. 14, 2026 Report No.: LGT25L401HA02 Page 2 of 8 TEST REPORT CERTIFICATION Applicant: Nube iO Address: 1/17 Cemetery Rd, Helensburgh, NSW 2508, Australia Manufacturer: Shenzhen Elecrow Co.,ltd Address: 4-5th Floor, Building B,Nanchang Huafeng Industrial Park, Baoan District, Shenzhen, China 518126 Product Name: Droplet Gen2 Trademark: N/A Model Number: DR-07-N1 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47 CFR §2.1091 KDB 447498 D01 General RF Exposure Guidance v06 PASS Prepared by: Approved by: Chris Chen Vita Li Engineer Technical Director Report No.: LGT25L401HA02 Page 3 of 8 TABLE OF CONTENTS 1 . GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST LABORATORY 5 2 . FCC 47CFR §2.1091 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 EUT OPERATION CONDITION 7 2.4 CLASSIFICATION 7 2.5 TEST RESULT 8 Report No.: LGT25L401HA02 Page 4 of 8 Revision History Rev. Issue Date Revisions 00 Jul. 14, 2026 Initial Issue Report No.: LGT25L401HA02 Page 5 of 8 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name: Droplet Gen2 Test Model Number: DR-07-N1 Series Number: N/A Model Difference: N/A Frequency Bands: LoRa 902.3-914.9 MHz Battery: Capacity: 4000mAh Rated Voltage: 3.6V Hardware Version: V1.0 Software Version: V1.0.0 1.2 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 Report No.: LGT25L401HA02 Page 6 of 8 2. FCC 47CFR §2.1091 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 0.3-3.0 614 1.63 *(100) 3.0-30 1842/f 4.89/f *(900/f 2 ) 30-300 61.4 0.163 1.0 300 - 1500 -- -- F/300 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 0.3-1.34 614 1.63 *(100) 1.34-30 824/f 2.19/f *(180/f 2 ) 30-300 27.5 0.073 0.2 300 - 1500 -- -- F/1500 1500 – 100000 -- -- 1.0 F= Frequency in MHz * = Plane-wave equivalent power density. Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. Report No.: LGT25L401HA02 Page 7 of 8 2.3 EUT OPERATION CONDITION EUT was enabled to transmit and receive at lowest, middle and highest channels. 2.4 CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance from the antenna should be included in the User manual. So, this device is classified as Mobile device. Report No.: LGT25L401HA02 Page 8 of 8 2.5 TEST RESULT Turn up Result Mode Turn up Power LoRa -6±1dBm Note: dBm=dBuv/[email protected] The MPE result of worst mode: RF Function Max Turn up Power (dBm) Max Turn up Power (mW) Power Density (mW/cm²) Limit (mW/cm²) Ratio Result LoRa -5.00 0.32 0.0001 0.6015333 0.0001 Pass Note: 1. The Maximum Power Density is less than the limit, complies with the exemption requirements. ※※※※※END OF THE REPORT※※※※※

Test Report

ISM 868 / 915 MHz ANTENNA FEATURES& BENEFITS DATA AND DEVICES /// ISM868 / 915 MHzANTENNA SPECIFICATIONS P/N2195835-1/-2/-3/-5/-6/-72195835-4/-8 Frequency Range (MHz)863-928863-928 VSWR< 2.3:1< 2.3:1 Average Efficiency35%47% Peak Gain1.4dBi-0.9dBi AverageGain-4.5dB-3.2dB Power Handling10 Watt cw Feed Point Impedance50 ohms unbalanced PolarizationLinear Size38 mm x 9.0 mm x 0.2 mm Weight< 0.9 g MountingAdhesive flexible tape Mating ConnectorsMHF type receptacle (TE PN 2337019-1), MHF4 type receptacle (TE PN: 2334884-1) Operating Temperature -40 to +85°C Storage Temperature -40 to +85°C Hazardous MaterialsA certificate of conformance is available from the product page on TE website. •ISM antenna, including of 868 / 915 ISM and IoT products •Available cable lengths: 50,100,150,200 mm, custom specific (Different cable lengths having impact on RF performance, see individual RF data) •Available connectors: MHF, MHF4 or compatible, custom specific •FPC with double side adhesive tape simplifies mounting within the device even on curved areas •Omnidirectional coverage Part Number: X-2195835-X (see page 7 for details) Return LossVSWR Efficiency RF DATA ≤ 150 mm cable length P/N: 2195835-1/ -2/-3/ -5/-6/-7 Data measured in free space and on plastic device enclosure ISM868 / 915MHzANTENNA Standard Antenna Solutions DATA AND DEVICES /// ISM868 / 915 MHzANTENNA Azimuth Elevation 2 Elevation 1 Test setup Azimuth Plane Elevation 1 Plane Elevation 2 Plane RADIATION PATTERN ≤ 150 mm cable length P/N: 2195835-1/ -2/-3/ -5/-6/-7 Data measured in free space and on plastic device enclosure 0° 90° 0° 90° Y X Z ISM868 / 915MHzANTENNA Standard Antenna Solutions DATA AND DEVICES /// ISM868 / 915 MHzANTENNA Return LossVSWR Efficiency RF DATA for 200 mm cable length P/N: 2195835-4/ -8 Data measured in free space and on plastic device enclosure DATA AND DEVICES /// ISM868 / 915 MHzANTENNA ISM868 / 915MHzANTENNA Standard Antenna Solutions Azimuth Elevation 2 Elevation 1 Test setup Azimuth Plane Elevation 1 Plane Elevation 2 Plane Z 0° 90° 0° 90° Y X RADIATION PATTERN for 200 mm cable length P/N: 2195835-4/ -8 Data measured in free space and on plastic device enclosure DATA AND DEVICES /// ISM868 / 915 MHzANTENNA ISM868 / 915MHzANTENNA Standard Antenna Solutions DIMENSIONS KEEP OUT AREA NOTES 1. Antenna designed to be mounted on plastic cover. 2. Area in blue indicates Keep Out Area 3. Contact TE if keep out zone cannot be guaranteed. Dimension: mm Diagrams is not into scale DATA AND DEVICES /// ISM868 / 915 MHzANTENNA ISM868 / 915MHzANTENNA Standard Antenna Solutions Dimension: mm Diagrams is not into scale DATA AND DEVICES /// ISM868 / 915 MHzANTENNA ISM868 / 915MHzANTENNA Standard Antenna Solutions 1-2195835-230011.811.13MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 1-2195835-12509.841.13MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2195835-42007.871.13MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2195835-31505.901.13MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2195835-21003.931.13MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 2195835-1501.971.13MHF-TYPE PLUGRECEPTACLE (TE PN: 2337019-1) 1-2195835-430011.811.13MHF4L-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 1-2195835-32509.841.13MHF4L-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 2195835-82007.871.13MHF4L-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 2195835-71505.901.13MHF4L-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 2195835-61003.931.13MHF4L-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) 2195835-5501.971.13MHF4L-TYPE PLUGRECEPTACLE (TE PN: 2334884-1) PARTMMINCH CABLE (OD) mm CONNECTOR TYPEPART NUMBER IMAGE NUMBERCABLE LENGTH(A)(ON CABLE)MATING COMPONENTS MATING COMPONENTS TO PART NUMBERS AND DIMENSIONS TE TECHNICAL SUPPORT CENTER USA: +1 (800) 522-6752 Canada: +1 (905) 475-6222 Mexico: +52 (0) 55-1106-0800 Latin/S. America: +54 (0) 11-4733-2200 Germany: +49 (0) 6251-133-1999 UK: +44 (0) 800-267666 France: +33 (0) 1-3420-8686 Netherlands: +31 (0) 73-6246-999 China: +86 (0) 400-820-6015 For phone numbers in other countries, go to te.com/support-center te.com TE Connectivity, TE Connectivity (logo) are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2020 TE Connectivity Ltd. family of companies All Rights Reserved. 09/2020 PACKAGING DATA AND DEVICES /// ISM868 / 915 MHzANTENNA ISM868 / 915MHzANTENNA Standard Antenna Solutions

Test Report

The test report is effective only with both signature and specialized stamp. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report only apply to the tested sample. Shenzhen LGT Test Service Co., Ltd. Tel: 0755-89668180 E-mail:[email protected] Web: www.lgt-cert.com Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Page 1 of 28 RF TEST REPORT Product Name: Droplet Gen2 Model Number: DR-07-N1 FCC ID: 2BVYH-DR07N1 Issued For : Nube iO 1/17 Cemetery Rd, Helensburgh, NSW 2508, Australia Issued By : Shenzhen LGT Test Service Co., Ltd. Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Report Number: LGT25L401RF02 Sample Received Date: Dec. 22, 2025 Date of Test: Mar. 05, 2026 ~ Jul. 14, 2026 Date of Issue: Jul. 14, 2026 Report No.: LGT25L401RF02 Page 2 of 28 TEST REPORT CERTIFICATION Applicant: Nube iO Address: 1/17 Cemetery Rd, Helensburgh, NSW 2508, Australia Manufacturer: Shenzhen Elecrow Co.,ltd Address: 4-5th Floor, Building B,Nanchang Huafeng Industrial Park, Baoan District, Shenzhen, China 518126 Product Name: Droplet Gen2 Trademark: N/A Model Number: DR-07-N1 Sample Status: Normal APPLICABLE STANDARDS STANDARD TEST RESULTS FCC Part 15.249, Subpart C ANSI C63.10-2020 + COR. 1-2023+C63.10A-2024 + ERRATA TO C63.10A-2024 PASS Prepared by: Approved by: Chris Chen Vita Li Engineer Technical Director Report No.: LGT25L401RF02 Page 3 of 28 Table of Contents Page 1. SUMMARY OF TEST RESULTS 5 1.1 TEST LABORATORY 6 1.2 MEASUREMENT UNCERTAINTY 6 2. GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF THE EUT 7 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 9 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 14 4. RADIATED EMISSION MEASUREMENT 15 4.1 RADIATED EMISSION LIMITS 15 4.2 TEST PROCEDURE 16 4.3 TEST SETUP 17 4.4 EUT OPERATING CONDITIONS 17 4.5 FIELD STRENGTH CALCULATION 18 4.6 TEST RESULTS 19 4.7 TEST RESULTS (BAND EDGE REQUIREMENTS) 24 4.8 TEST RESULTS (EIRP REQUIREMENTS) 24 5. BANDWIDTH TEST 25 5.1 TEST PROCEDURE 25 5.2 TEST SETUP 25 5.3 EUT OPERATION CONDITIONS 25 5.4 TEST RESULTS 25 6. ANTENNA REQUIREMENT 27 6.1 STANDARD REQUIREMENT 27 6.2 EUT ANTENNA 27 APPENDIX I - MEASUREMENT PHOTOS 28 Report No.: LGT25L401RF02 Page 4 of 28 Revision History Rev. Issue Date Revisions 00 Jul. 14, 2026 Initial Issue Report No.: LGT25L401RF02 Page 5 of 28 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part 15.249, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A -- 15.249 Radiated Spurious Emission PASS -- 15.205 Restricted Band Edge Emission PASS -- 15.249 20dB Bandwidth Pass -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020 + COR. 1-2023+C63.10A-2024 + ERRATA TO C63.10A-2024. Report No.: LGT25L401RF02 Page 6 of 28 1.1 TEST LABORATORY Company Name: Shenzhen LGT Test Service Co., Ltd. Address: Room 205, Building 13, Zone B, Zhenxiong Industrial Park, No.177, Renmin West Road, Jinsha, Kengzi Street, Pingshan District, Shenzhen, Guangdong, China Accreditation Certificate: FCC Registration No.: 746540 CAB ID: CN0136 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Occupied Channel Bandwidth ±0.46% 2 RF Output Power, Conducted ±0.71dB 3 Power Spectral Density, Conducted ±1.57dB 4 Unwanted Emission, Conducted ±0.63dB 5 Conducted emission ±2.80dB 6 All Emissions, Radiated (0.009-30MHz) ±2.16dB 7 All Emissions, Radiated (30MHz-1GHz) ±4.61dB 8 All Emissions, Radiated (1GHz-18GHz) ±5.49dB Note: The measurement uncertainty is not included in the test result. Report No.: LGT25L401RF02 Page 7 of 28 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name: Droplet Gen2 Test Model Number: DR-07-N1 Series Number: N/A Model Difference: N/A Product Description: Operation Frequency: 902.3-914.9 MHz Modulation Type: LoRa Antenna Type: FPC Antenna Antenna Gain(dBi): 1.4 Battery: Capacity: 4000mAh Rated Voltage: 3.6V Hardware Version: V1.0 Software Version: V1.0.0 Connecting I/O Port(s): Please refer to the Note 1. Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User Manual. 2. The antenna information refers to the manufacturer provide report, applicable only to the tested sample identified in the report. Due to the incorrect antenna information, a series of problems such as the accuracy of the test results will be borne by the customer. Report No.: LGT25L401RF02 Page 8 of 28 3. Channel List Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 0 902.3 22 906.7 44 911.1 1 902.5 23 906.9 45 911.3 2 902.7 24 907.1 46 911.5 3 902.9 25 907.3 47 911.7 4 903.1 26 907.5 48 911.9 5 903.3 27 907.7 49 912.1 6 903.5 28 907.9 50 912.3 7 903.7 29 908.1 51 912.5 8 903.9 30 908.3 52 912.7 9 904.1 31 908.5 53 912.9 10 904.3 32 908.7 54 913.1 11 904.5 33 908.9 55 913.3 12 904.7 34 909.1 56 913.5 13 904.9 35 909.3 57 913.7 14 905.1 36 909.5 58 913.9 15 905.3 37 909.7 59 914.1 16 905.5 38 909.9 60 914.3 17 905.7 39 910.1 61 914.5 18 905.9 40 910.3 62 914.7 19 906.1 41 910.5 63 914.9 20 906.3 42 910.7 / / 21 906.5 43 910.9 / / Test Frequency Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 0 902.3 32 908.7 63 914.9 Report No.: LGT25L401RF02 Page 9 of 28 2.2 DESCRIPTION OF THE TEST M…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 Report No.: LGT25L401 Appendix - Test Setup photos Set-up for Radiated Spurious Emission, Below 1GHz Set-up for Radiated Spurious Emission, Above 1GHz

Contact Information

Applicant

Hoai Hoang
[email protected]Fax: /

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue, Saint Charles, IL, 60174, US · United States

Test Firm

Shenzhen LGT Test Service Co., Ltd.Wen Wen
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.3 MHz - 914.9 MHz-
Confidentiality
Long Term

Other Applications from Nube iO

LoRaLink - FCC ID 2BVYH-UL01N1 - Nube iO
2BVYH-UL01N1

LoRaLink

Sep 18, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Zoneconnex - FCC ID 2BVYH-ZC01N1 - Nube iO
2BVYH-ZC01N1

Zoneconnex

May 20, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Touch Point LCD - FCC ID 2BVYH-TP01N1 - Nube iO
2BVYH-TP01N1

Touch Point LCD

May 19, 2026

Equipment Class

DTS - Digital Transmission System