
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Keep instructions for future reference. Be sure Use & Care Guide stays with oven. Part No.8112P297-60 Code No. DE68-03143F Use & Care Guide Model AMV5206BA Over The Range Microwave Oven Important Safety Instructions . . . . . . . . . . . . . . . . . . 2 Precautions to Avoid Possible Exposure to Excessive Microwave Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . 8 Care and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Cooking Utensils . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Form No. A/08/05 2 Important Safety Instructions Installer: Please leave this guide with this appliance. Consumer: Please read and keep this Use & Care Guide for future reference. Keep sales receipt and/or cancelled check as proof of purchase. Model Number ________________________________ Serial Number_________________________________ Date of Purchase ______________________________ In our continuing effort to improve the quality and performance of our appliances, it may be necessary to make changes to the appliance without revising this guide. If you have questions, write us (include your model number and phone number) or call: Maytag Services SM Attn: CAIR ® Center P.O. Box 2370 Cleveland, TN 37320-2370 1-800-843-0304 U.S.A 1-866-587-2002 Canada 1-800-688-2080 (US TTY for hearing or speech impaired) (Mon.-Fri., 8 a.m.-8 p.m. Eastern Time) Internet: http://www.amana.com What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in this Use & Care Guide are not meant to cover all possible conditions and situations that may occur. Common sense, caution, and care must be exercised when installing, maintaining, or operating microwave. Always contact your dealer, distributor, service agent, or manufacturer about problems or conditions you do not understand. Recognize Safety Symbols, Words, Labels DANGER DANGER – Immediate hazards which WILL result in severe personal injury or death. WARNING WARNING – Hazards or unsafe practices which COULD result in severe personal injury or death. CAUTION CAUTION – Hazards or unsafe practices which COULD result in minor personal injury. To avoid personal injury or property damage, observe the following: 1. Do not deep fat fry in oven. Fat could overheat and be hazardous to handle. 2. Do not cook or reheat eggs in shell or with an unbroken yolk using microwave energy. Pressure may build up and erupt. Pierce yolk with fork or knife before cooking. 3. Pierce skin of potatoes, tomatoes, and similar foods before cooking with microwave energy. When skin is pierced, steam escapes evenly. 4. Do not operate oven without load or food in oven cavity. 5. Use only popcorn in packages designed and labeled for microwave use. Popping time varies depending on oven wattage. Do not continue to heat after popping has stopped. Popcorn will scorch or burn. Do not leave oven unattended. 6. Do not use regular cooking thermometers in oven. Most cooking thermometers contain mercury and may cause an electrical arc, malfunction, or damage to oven. 7. Do not use metal utensils in oven. 8. Never use paper, plastic, or other combustible materials that are not intended for cooking. 9. When cooking with paper, plastic, or other com- bustible materials, follow manufacturer's recom- mendations on product use. 10. Do not use paper towels which contain nylon or other synthetic fibers. Heated synthetics could melt and cause paper to ignite. 11. Do not heat sealed containers or plastic bags in oven. Food or liquid could expand quickly and cause container or bag to break. Pierce or open container or bag before cooking. 12. To avoid pacemaker malfunction, consult physician or pacemaker manufacturer about effects of microwave energy on pacemaker. CAUTION SAVE THESE INSTRUCTIONS 3 Important Safety Instructions Grounding Instructions Oven MUST be grounded. Grounding reduces risk of electric shock by providing an escape wire for the electric current if an electrical short occurs. This oven is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. See Installation Instructions. Consult a qualified electrician or servicer if grounding instructions are not completely understood, or if doubt exists as to whether the oven is properly grounded. Do not use an extension cord. If the product power cord is too short, have a qualified electrician install a three-slot receptacle. This oven should be plugged into a separate 60 hertz circuit with the electrical rating as shown in specifications table. When the oven is on a circuit with other equipment, an increase in cooking times may be required and fuses can be blown. Microwave operates on standard household current, 110- 120V. WARNING To avoid risk of electrical shock or death, this oven must be grounded and plug must not be altered. SAVE THESE INSTRUCTIONS Federal Communications Commission Radio Frequency Interference Statement (U.S.A. Only) This equipment generates and uses ISM frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with limits for ISM Equipment pursuant to part 18 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, th…
Text truncated - open the document above for the full version.
RBW 1 MHz VBW 1 MHz SWT 5 ms A IN1 Unit dB Ì V RF Att 50 dB Ref Lvl 120 dB Ì V Ref Lvl 120 dB Ì V 30 MHz/Center 2.45 GHzSpan 300 MHz P20 1VIEW1AV 30 40 50 60 70 80 90 100 110 20 120 1 2 3 Marker 1 [T1] 110.19 dB Ì V 2.46292585 GHz 1 [T1] 110.19 dB Ì V 2.46292585 GHz 2 [T1] 91.93 dB Ì V 2.43346693 GHz 3 [T1] 90.62 dB Ì V 2.46533066 GHz F1 F2 D1 110.09 dB Ì V D2 90.19 dB Ì V Date: 25.AUG.2005 02:26:58