XXXTBNTVOHDPN 8VHU0DQXDO &OHMJTI &6 3FW 60N81W Table of Contents Basics 3FBENFGJSTU 1BDLBHFDPOUFOUT %FWJDFMBZPVU 4*.PS64*.DBSE #BUUFSZ 5VSOJOHUIFEFWJDFPOBOEPGG 5PVDITDSFFO )PNFTDSFFO -PDLTDSFFO /PUJGJDBUJPOQBOFM &OUFSJOHUFYU 4DSFFODBQUVSF 0QFOJOHBQQT .VMUJXJOEPX %FWJDFBOEEBUBNBOBHFNFOU $POOFDUJOHUPB57 &NFSHFODZNPEF Settings *OUSPEVDUJPO 8J'J #MVFUPPUI 5FUIFSJOHBOE.PCJMFIPUTQPU 'MJHIUNPEF %BUBVTBHF .PCJMFOFUXPSLT .PSF 4PVOEBOEOPUJGJDBUJPO %JTQMBZ .PUJPOTHFTUVSFT "QQMJDBUJPOT 8BMMQBQFS 5IFNFT -PDLTDSFFOTFDVSJUZ 1SJWBDZTBGFUZ &BTZNPEF "DDFTTJCJMJUZ "DDPVOUT #BDLVQBOESFTFU -BOHVBHFBOEJOQVU #BUUFSZ 4UPSBHF %BUFBOEUJNF 6TFSNBOVBM "CPVUEFWJDF Applications *OTUBMMJOHPSVOJOTUBMMJOHBQQT 1IPOF $POUBDUT .FTTBHFT *OUFSOFU &NBJM 5BCMFPG$POUFOUT $BNFSB (BMMFSZ 4NBSU.BOBHFS 41MBOOFS 4)FBMUI 47PJDF .VTJD 7JEFP 7PJDF3FDPSEFS .Z'JMFT .FNP $MPDL $BMDVMBUPS (PPHMFBQQT .JDSPTPGUBQQT Appendix "DDFTTJCJMJUZ 5SPVCMFTIPPUJOH 3FNPWJOHUIFCBUUFSZ OPOSFNPWBCMF UZQF Basics Read me first Please read this manual before using the device to ensure safe and proper use. r Descriptions are based on the device’s default settings. r S ome content may differ from your device depending on the region, service provider, model specifications, or device’s software. r C ontent (high quality content) that requires high CPU and RAM usage will affect the overall performance of the device. Apps related to the content may not work properly depending on the device’s specifications and the environment that it is used in. r Samsung is not liable for performance issues caused by apps supplied by providers other than Samsung. r Samsung is not liable for performance issues or incompatibilities caused by edited registry settings or modified operating system software. Attempting to customise the operating system may cause the device or apps to work improperly. r S oftware, sound sources, wallpapers, images, and other media provided with this device are licensed for limited use. Extracting and using these materials for commercial or other purposes is an infringement of copyright laws. Users are entirely responsible for illegal use of media. r You may incur additional charges for data services, such as messaging, uploading and downloading, auto-syncing, or using location services depending on your data plan. For large data transfers, it is recommended to use the Wi-Fi feature. r Default apps that come with the device are subject to updates and may no longer be supported without prior notice. If you have questions about an app provided with the device, contact a Samsung Service Centre. For user-installed apps, contact service providers. r Modifying the device’s operating system or installing softwares from unofficial sources may result in device malfunctions and data corruption or loss. These actions are violations of your Samsung licence agreement and will void your warranty. r %FQFOEJOHPOUIFSFHJPOPSNPEFM TPNFEFWJDFTBSFSFRVJSFEUPSFDFJWFBQQSPWBMGSPN UIF'FEFSBM$PNNVOJDBUJPOT$PNNJTTJPO '$$ *GZPVSEFWJDFJTBQQSPWFECZUIF'$$ ZPVDBOWJFXUIF'$$*%PGUIFEFWJDF5PWJFXUIF'$$*% UBQ4FUUJOHT About PhoneStatus r Supprted features may differPSMBCFMMFEEJGGFSFOUMZEFQFOEJOHPOXIFUIFSZPVS EFWJDFJTBTJOHMFPSEVBM4*..PEFM #BTJDT Instructional icons WarningTJUVBUJPOTUIBUDPVMEDBVTFJOKVSZUPZPVSTFMGPSPUIFST CautionTJUVBUJPOTUIBUDPVMEDBVTFEBNBHFUPZPVSEFWJDFPSPUIFSFRVJQNFOU NoticeOPUFT VTBHFUJQT PSBEEJUJPOBMJOGPSNBUJPO Package contents $IFDLUIFQSPEVDUCPYGPSUIFGPMMPXJOHJUFNT r %FWJDF r 2VJDLTUBSUHVJEF r 5IFJUFNTTVQQMJFEXJUIUIFEFWJDFBOEBOZBWBJMBCMFBDDFTTPSJFTNBZWBSZ EFQFOEJOHPOUIFSFHJPOPSTFSWJDFQSPWJEFS r 5IFTVQQMJFEJUFNTBSFEFTJHOFEPOMZGPSUIJTEFWJDFBOENBZOPUCFDPNQBUJCMF XJUIPUIFSEFWJDFT r "QQFBSBODFTBOETQFDJGJDBUJPOTBSFTVCKFDUUPDIBOHFXJUIPVUQSJPSOPUJDF r :PVDBOQVSDIBTFBEEJUJPOBMBDDFTTPSJFTGSPNZPVSMPDBM4BNTVOHSFUBJMFS.BLF TVSFUIFZBSFDPNQBUJCMFXJUIUIFEFWJDFCFGPSFQVSDIBTF r 6TFPOMZ4BNTVOHBQQSPWFEBDDFTTPSJFT6TJOHVOBQQSPWFEBDDFTTPSJFTNBZDBVTF UIFQFSGPSNBODFQSPCMFNTBOENBMGVODUJPOTUIBUBSFOPUDPWFSFECZUIFXBSSBOUZ r "WBJMBCJMJUZPGBMMBDDFTTPSJFTJTTVCKFDUUPDIBOHFEFQFOEJOHFOUJSFMZPO NBOVGBDUVSJOHDPNQBOJFT'PSNPSFJOGPSNBUJPOBCPVUBWBJMBCMFBDDFTTPSJFT SFGFS UPUIF4BNTVOHXFCTJUF #BTJDT Device layout .JDSPQIPOF .JDSPQIPOF -PVETQFBLFS #BDLLFZ .VMUJQVSQPTFKBDL 'SPOUDBNFSB 4QFBLFS 1PXFSLFZ 5PVDITDSFFO 3FDFOUTLFZ )FBETFUKBDL 'JOHFSQSJOUSFDPHOJUJPOTFOTPS -&%JOEJDBUPS 1SPYJNJUZ-JHIUTFOTPS 4*.DBSEUSBZ .BJOBOUFOOB *OGSBSFEQPSU 'MBTI 7PMVNFLFZ /'$BOUFOOB8JSFMFTT DIBSHJOHDPJM 3FBSDBNFSB .JDSPQIPOF (14BOUFOOB #BTJDT r %POPUDPWFSUIFBOUFOOBBSFBXJUIZPVSIBOETPSPUIFSPCKFDUT5IJTNBZDBVTF DPOOFDUJWJUZQSPCMFNTPSESBJOUIFCBUUFSZ r 6TJOHB4BNTVOHBQQSPWFETDSFFOQSPUFDUPSJTSFDPNNFOEFE6OBQQSPWFETDSFFO QSPUFDUPSTNBZDBVTFUIFTFOTPSTUPNBMGVODUJPO r %POPUBMMPXXBUFSUPDPOUBDUUIFUPVDITDSFFO5IFUPVDITDSFFONBZNBMGVODUJPO JOIVNJEDPOEJUJPOTPSXIFOFYQPTFEUPXBUFS Keys KeyFunction Power r 1SFTTBOEIPMEUPUVSOUIFEFWJDFPOPSPGG r 1SFTTUPUVSOPOPSMPDLUIFTDSFFO Recents r 5BQUPPQFOUIFMJTUPGSFDFOUBQQT r 5BQBOEIPMEUPMBVODIUIFTQMJUTDSFFOWJFX Home r 1SFTTUPUVSOPOUIFTDSFFOXIJMFUIFTDSFFOJTMPDLFE r 1SFTTUPSFUVSOUPUIF)PNFTDSFFO r 1SFTTBOEIPMEUPMBVODIGoogle Back r 5BQUPSFUVSOUPUIFQSFWJPVTTDSFFO Volume r 1SFTTUPBEKVTUUIFEFWJDFWPMVNF #BTJDT SIM or USIM card Installing the SIM or USIM card *OTFSUU…
Text truncated - open the document above for the full version.
Samsung Electronics America, Inc 19 Chapin Rd, Building D. Pine Brook, NJ 07058 Date: July 14, 2020 FCC ID: A3LSMN981W To whom it may concern: We, the undersigned, hereby authorize PCTEST Engineering Laboratory LLC, to act on our behalf in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. Any and all acts carried out by PCTEST Engineering Laboratory, LLC on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to any application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S. C. 862. Sincerely, Jenni Chun General Manager Regulatory & Environmental Affairs Samsung Electronics CO. LTD TEL: +1-973-808-6375 Fax : 1-973-808-6361 E-mail: [email protected]
SAMSUNG ELECTRONICS CO., LTD 129, Samsung-ro, Yeongtong-gu Suwon-si, Gyeonggi-do, 443-742 Korea 2020.07.04 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT : Label Statement FCC ID : A3LSMN981W To whom i t may concern We hereby provide the following attestations according to CFR 2.935 and FCC KDB 784748 D02: At t he time of purchase, the FCC ID is readily and physically visible to the purchaser on the exterior package per CFR 2.935(f). The FCC ID will be readily legible without the aid of magnification according to CFR 2.935(d). The literature in the package describes how to access the electronic display to find the FCC ID per CRF 2.935(b) and FCC KDB 784748. Per CFR 2.935(c), the user will be able to access this information within a maximum of 3 steps. The user will be able to access this information without a SIM card, special accessories or supplemental plug -ins. Per CFR 2.935(e), We, Samsung have programmed the e-label and it is not able to be modified by any third party. Per CFR 2.935(f), the FCC ID will be able to survive normal shipping and handling so it is visible for inspection at the time of import. Should y ou have any questions or comments concerning the above, please contact the undersigned. Sincer ely Yours, Jenni Chun / General Manager Samsung Electronics America, Inc. Address: 19 Chapin Rd., Building D Pine Brook, NJ 07058 Tel: 1-973-808-6375
Date: 2020.07.04 PCTEST TCB/CB Div. of PCTEST Engineering Lab., LLC. 7185 Oakland Mills Road Columbia, MD 21046 Samsung Electronics Co., LTD. 129, Samsung-ro, Yeongtong-gu Suwon-City, Gyeonggi-do, 16677, Korea Subject: Samsung Electronics Co., Ltd. FCC ID: A3LSMN981W To Whom it May Concern We attest the following regarding FCC ID: A3LSMN981W 1.MPR is permanently implemented for all channel BWs, modulations, frequency bands and RB sizes. 2.A-MPR was disabled for all SAR test samples for SAR testing purposes only. 3.We confirm the specific MPR targets and tolerances shown in the SAR Report. 4. LTE Rel.16 implementation is limited. The uplink does not support other carrier aggregation nor enhanced SC-FDMA. Features such as CoMP, HetNet, Relay, SON, cross carrier scheduling, Uplink MIMO and M2M/D2 are also not supported. SVLTE is not supported as described in the operational description. 5.This device complies with FCC Part 27.75(a)(1) requirements: Mobile and portable stations that operate on any portion of frequencies in the paired 1755-1780 MHz and 2155-2180 MHz band must be capable of operating on all frequencies in the paired 1710-1780 MHz and 2110-2180 MHz band, using the same air interfaces that the equipment utilizes on any frequencies in the paired 1710-1780 MHz and 2110-2180 MHz band. 6.This device complies with FCC Part 27.75(a)(2) requirements: Mobile and portable stations that operate on any portion of frequencies in the 600 MHz band must be capable of operating on all frequencies in the 600 MHz band using the same air interfaces that the equipment utilizes on any frequencies in the 600 MHz band. 7.This device complies with FCC Part 27.77 requirements: Mobile and portable station in the 1695-1710 MHz and 1755-1780 MHz bands may operate only when under the control of base station. Base stations that enable mobile or portable equipment to operate in the 1695-1710 MHz and 1755-1780 MHz band are subjected to prior coordination requirements. Should you have any questions or comm ents conc erning the above, please contact the undersigned. S incerely, Jenni Chun / General Manager Samsung E lectronics America, Inc. Address: 19 Chapin Rd., Building D Pine Brook, NJ 07058 Tel: 1-973-808-6375
Date: 2020.07.04 Samsung Electronics Co., LTD. 129, Samsung-ro, Yeongtong-gu Suwon-City, Gyeonggi-do, 443-742, Korea Subject: 5G Sub-6GHz HAC Attestation FCC ID: A3LSMN981W To Whom it May Concern We attest the handset as designed is expected to exhibit similar audio intensity levels between a OTT VoIP call placed over a 4G LTE and a 5G Sub-6GHz data connection. This device does not currently support VoNR but does not prohibit VoNR after sale when supported by the CMRS service provider. Should you have any questions or comments concerning the above, please contact the undersigned. Sincerely, Jenni Chun / General Manager Samsung Electronics America, Inc. Address: 19 Chapin Rd., Building D Pine Brook, NJ 07058 Tel: 1-973-808-6375
Date: July 23 rd , 2020 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: SAMSUNG ELECTRONICS CO.,LTD. FCC ID: A3LSMN981W Part 20.19 Certification To Whom It May Concern: The following are the model designations and their associated key features for this FCC ID, according to requirement in the KDB 285076 D01. We, Samsung Electronics, hereby declare the samples evaluated in this application are equivalent to production samples. This device features a HAC mode software setting which activates audio gains and shaping during HAC operation to improve audio performance for users with hearing loss. Jenni Chun General Manager Samsung Electronics Co., Ltd. CDMA GSM WCDMA LTE NR CDMA GSM WCDMA LTE LTE Band 41 Implementation NR GPS NFC SMS,MMS Bluetooth (BT), Bluetooth LE WIFI MS T VoLTE VoWIFI P re - insta lle d VoIP Applic a tion S pe c ia l Voic e Interfaces: Yes Yes Google Duo Profiles not included in held-to-ear mode: BT Key Features: Yes Yes Yes Yes Yes Yes Radio Services: EVDO GPRS/EGPRS HSDPA/HSUPA, DC-HSDPA/HSPA+ FDD / TDD Power Class 3 FDD, TDD, EN-DC Only FCC ID:A3LSMN981W Model(s):SM-N981W Air Interfaces: BC0 GSM 850/1900 B2/4/5 B2/4/5/7/12/13/25/29(DL Only)/30/38/41/46(DL Only)/66/71 n71/66/41
SAMS UNG ELECTRONICS AMERICA, INC. American QA Lab 19 Chapin Rd, Building D. Pine Brook, NJ 07058 Date: July 14, 2020 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 RE:Request of Confidentiality for FCC ID: A3LSMN981W To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, SAMSUNG ELECTRONICS CO.,LTD. hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily re leased to th e public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 day s after the grant as outlined in Public Notice DA 04-1705. This provision will give SAMSUNG ELECTRONICS CO.,LTD. temporary confidentiality of commercially sensitive information pri or to product release. The requested Permanent and Short-Term Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST ExhibitDescription PERMANENT 1 Block Diagram 2 Operational Description 3 Schematics 4 Parts List & Tune-Up Procedure SHORT-TERM 5 External Photos 6 Internal Photos 7 Test-Setup Photos 8 Users Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Sincerely, Jenni Chun General Manager Regulatory & Environmental Affairs Samsung Electronics CO. LTD TEL: +1-973-808-6375 Fax : 1-973-808-6361 E-mail: [email protected]
FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W
Description of E-label on the A3LSMN981W Date: 2020.07.01 FCC ID: A3LSMN981W This model is applied E-label, please find description of E-label below. 1.FCC I D (E-label): Settings > About Phone > Status FCC certific ation FCC ID: A3LSMN981W <De vice Display Screen> 2.FCC ID on the Quick Start Guide The FCC has granted an Equipment Authorization for this model device based on the compliance of all reported SAR levels with the FCC RF exposure guide lines. This device has a FCC ID number A3LSMN981W [Model Number: SM-N981W] and the specific SAR levels for this device can be found at the following. FC C website: www.fcc.gov/oet/ea/ The SAR information for this device can be found on Samsung’s website: www.samsung.com/sar 3.Insturction of E-label on the User manual (online manual)
FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W FCC ID : A3LSMN981W
© 2020 PCTEST A P P E N D I X B : SY S T E M V E R I F I C A T I O N B1 PCTEST DUT: Dipole 750 MHz; Type: D750V3; Serial: 1054 Communication System: UID 0, CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: 750 Head Medium parameters used: f = 750 MHz; σ = 0.873 S/m; ε r = 41.208; ρ = 1000 kg/m 3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 06/08/2020; Ambient Temp: 22.3°C; Tissue Temp: 22.0°C Probe: EX3DV4 - SN7410; ConvF(9.95, 9.95, 9.95) @ 750 MHz; Calibrated: 7/16/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2019 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) 750 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.39 W/kg SAR(1 g) = 1.65 W/kg Deviation(1 g) = -4.40% 0 dB = 2.16 W/kg = 3.34 dBW/kg B2 PCTEST DUT: Dipole 750 MHz; Type: D750V3; Serial: 1054 Communication System: UID 0, CW; Frequency: 750 MHz; Duty Cycle: 1:1 Medium: 750 Head Medium parameters used: f = 750 MHz; σ = 0.875 S/m; ε r = 40.611; ρ = 1000 kg/m 3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 06/11/2020; Ambient Temp: 24.0°C; Tissue Temp: 22.5°C Probe: EX3DV4 - SN7410; ConvF(9.95, 9.95, 9.95) @ 750 MHz; Calibrated: 7/16/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2019 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) 750 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x15x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.38 W/kg SAR(1 g) = 1.65 W/kg Deviation(1 g) = -4.40% 0 dB = 2.16 W/kg = 3.34 dBW/kg B3 PCTEST DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d132 Communication System: UID 0, CW; Frequency: 835 MHz; Duty Cycle: 1:1 Medium: 835 Head Medium parameters used: f = 835 MHz; σ = 0.886 S/m; ε r = 40.641; ρ = 1000 kg/m 3 Phantom section: Flat Section; Space: 1.5 cm Test Date: 06/10/2020; Ambient Temp: 24.0°C; Tissue Temp: 21.6°C Probe: EX3DV4 - SN7410; ConvF(9.88, 9.88, 9.88) @ 835 MHz; Calibrated: 7/16/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1322; Calibrated: 7/11/2019 Phantom: Twin-SAM V8.0; Type: QD 000 P41 Ax; Serial: 1966 Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) 835 MHz System Verification at 23.0 dBm (200 mW) Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 2.79 W/kg SAR(1 g) = 1.86 W/kg Deviation(1 g) = -3.63% 0 dB = 2.49 W/kg = 3.96 dBW/kg B4 PCTEST DUT: Dipole 1750 MHz; Type: D1750V2; Serial: 1150 Communication System: UID 0, CW; Frequency: 1750 MHz; Duty Cycle: 1:1 Medium: 1750 Head; Medium parameters used: f = 1750 MHz; σ = 1.353 S/m; ε r = 39.243; ρ = 1000 kg/m 3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 06/10/2020; Ambient Temp: 23.5°C; Tissue Temp: 21.7°C Probe: EX3DV4 - SN7551; ConvF(8.34, 8.34, 8.34) @ 1750 MHz; Calibrated: 9/19/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 9/17/2019 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1792 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) 1750 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 7.22 W/kg SAR(1 g) = 3.78 W/kg Deviation(1 g) = 3.56% 0 dB = 5.84 W/kg = 7.66 dBW/kg B5 PCTEST DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d148 Communication System: UID 0, CW; Frequency: 1900 MHz; Duty Cycle: 1:1 Medium: 1900 Head; Medium parameters used: f = 1900 MHz; σ = 1.451 S/m; ε r = 39.329; ρ = 1000 kg/m 3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 06/12/2020; Ambient Temp: 23.9°C; Tissue Temp: 22.0°C Probe: EX3DV4 - SN7551; ConvF(8.05, 8.05, 8.05) @ 1900 MHz; Calibrated: 9/19/2019 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1333; Calibrated: 9/17/2019 Phantom: Twin-SAM V5.0; Type: QD 000 P40 CD; Serial: 1792 Measurement SW: DASY52, Version 52.10 (4);SEMCAD X Version 14.6.14 (7483) 1900 MHz System Verification at 20.0 dBm (100 mW) Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 8.09 W/kg SAR(1 g) = 4.19 W/kg Deviation(1 g) = 7.16% 0 dB = 6.12 W/kg = 7.87 dBW/kg B6 PCTEST DUT: Dipole 2300 MHz; Type: D2300V2; Serial: 1073 Communication System: UID 0, CW; Frequency: 2300 MHz; Duty Cycle: 1:1 Medium: 2450 Head Medium parameters used: f = 2300 MHz; σ = 1.671 S/m; ε r = 40.381; ρ = 1000 kg/m 3 Phantom section: Flat Section; Space: 1.0 cm Test Date: 06/05/2020; Ambient Temp: 23.5°C; Tissue Temp: 22.9°C Probe: EX3DV4 - SN3589; ConvF(7.11, 7.11, 7.11) @ 2300 MHz; Calibrated: 1/21/2020 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn1558; Calibrated: 1/13/2020 Phantom: Twin-SAM V5.0 (30); Type: QD 000 P40 CD; Serial: 1647 Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) 2300 MHz System Verification at 20.0 dBm (100 mW) Area Scan (8x9x1): Measurement grid: dx=12mm, dy=12mm Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 9.85 W/kg SAR(1 g) = 4.8 W/kg Deviation(1 g) = -2.44% 0 dB = 7.87 W/kg = 8.96 dBW/kg B7 PCTEST DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 719 Communication System: UID 0, CW; Frequency: 2450 MHz; Duty Cycle: 1:1 Medium: 2450 Head Medium parameters used: f = 2450 MHz; σ = 1.79 S/m; ε r = 38.583; ρ = 1000 kg/m 3 Phantom section: Flat Section; Space: 1.0cm Test Date: 06/07/2020; Ambient T…
Text truncated - open the document above for the full version.
FCC ID: A3LSMN981W SAR EVALUATION REPORT Approved by: Quality Manager Test Dates: DUT Type: APPENDIX C: Page 1 of 3 06/03/20 - 07/13/20 Portable Handset © 2020 PCTEST REV 21.4 M 09/11/2019 A P P E N D I X C : S A R T I S S U E S P E C I F I C A T I O N S Measurement Procedure for Tissue verification: 1) The network analyzer and probe system was configured and calibrated. 2) The probe was immersed in the tissue. The tissue was placed in a nonmetallic container. Trapped air bubbles beneath the flange were minimized by placing the probe at a slight angle. 3) The complex admittance with respect to the probe aperture was measured 4) The complex relative permittivity ε ’ can be calculated from the below equation (Pournaropoulos and Misra): where Y is the admittance of the probe in contact with the sample, the primed and unprimed coordinates refer to source and observation points, respectively, , is the angular frequency, and . Figure C-1 Note: Liquid recipes are proprietary SPEAG. Since the composition is approximate to the actual liquids utilized, the manufacturer tissue-equivalent liquid data sheets are provided below. ( ) − = b a b a r r d d d r r j a b j Y 0 2 / 1 0 ' 0 2 0 ) ( exp cos ln 2 − + = cos 2 2 2 2 r 1 − = j FCC ID: A3LSMN981W SAR EVALUATION REPORT Approved by: Quality Manager Test Dates: DUT Type: APPENDIX C: Page 2 of 3 06/03/20 - 07/13/20 Portable Handset © 2020 PCTEST REV 21.4 M 09/11/2019 Figure C-2 600 – 5800 MHz Body Tissue Equivalent Matter FCC ID: A3LSMN981W SAR EVALUATION REPORT Approved by: Quality Manager Test Dates: DUT Type: APPENDIX C: Page 3 of 3 06/03/20 - 07/13/20 Portable Handset © 2020 PCTEST REV 21.4 M 09/11/2019 Figure C-3 600 – 5800 MHz Head Tissue Equivalent Matter
FCC ID: A3LSMN981W SAR EVALUATION REPORT Approved by: Quality Manager Test Dates: DUT Type: APPENDIX D: Page 1 of 1 06/03/20 – 07/13/20 Portable Handset © 2020 PCTEST REV 21.4 M 09/11/2019 A P P E N D I X D : S A R S Y S T E M V A L I D A T I O N Per FCC KDB Publication 865664 D02v01r02, SAR system validation status should be documented to confirm measurement accuracy. The SAR systems (including SAR probes, system components and software versions) used for this device were validated against its performance specifications prior to the SAR measurements. Reference dipoles were used with the required tissue- equivalent media for system validation, according to the procedures outlined in FCC KDB Publication 865664 D01v01r04 and IEEE 1528-2013. Since SAR probe calibrations are frequency dependent, each probe calibration point was validated at a frequency within the valid frequency range of the probe calibration point, using the system that normally operates with the probe for routine SAR measurements and according to the required tissue-equivalent media. A tabulated summary of the system validation status including the validation date(s), measurement frequencies, SAR probes and tissue dielectric parameters has been included. Table D-1 SAR System Validation Summary – 1g Table D-2 SAR System Validation Summary – 10g NOTE: While the probes have been calibrated for both CW and modulated signals, all measurements were performed using communication systems calibrated for CW signals only. Modulations in the table above represent test configurations for which the measurement system has been validated per FCC KDB Publication 865664 D01v01r04 for scenarios when CW probe calibrations are used with other signal types. SAR systems were validated for modulated signals with a periodic duty cycle, such as GMSK, or with a high peak to average ratio (>5 dB), such as OFDM according to FCC KDB Publication 865664 D01v01r04. COND. PERM. (σ) (εr) SENSITIVITY PROBE LINEARITY PROBE ISOTROPY MOD. TYPE DUTY FACTOR PAR L 750 9/24/2019 7410 750 Head 0.878 42.471 PASS PASS PASS N/A N/A N/A L 835 9/24/2019 7410 835 Head 0.911 42.199 PASS PASS PASS GMSK PASS N/A P 1750 10/2/2019 7551 1750 Head 1.346 39.45 PASS PASS PASS N/A N/A N/A P 1900 10/2/2019 7551 1900 Head 1.444 39.26 PASS PASS PASS GMSK PASS N/A E 2300 2/5/2020 3589 2300 Head 1.717 39.033 PASS PASS PASS N/A N/A N/A E 2450 2/5/2020 3589 2450 Head 1.823 38.835 PASS PASS PASS OFDM/TDD PASS PASS E 2600 2/5/2020 3589 2600 Head 1.933 38.635 PASS PASS PASS TDD PASS N/A H 5250 5/7/2020 7357 5250 Head 4.644 35.12 PASS PASS PASS OFDM N/A PASS H 5600 5/7/2020 7357 5600 Head 5.03 34.51 PASS PASS PASS OFDM N/A PASS H 5750 5/7/2020 7357 5750 Head 5.207 34.26 PASS PASS PASS OFDM N/A PASS L 750 8/20/2019 7410 750 Body 0.941 54.921 PASS PASS PASS N/A N/A N/A E 750 2/21/2020 3589 750 Body 0.965 53.65 PASS PASS PASS N/A N/A N/A P 835 9/26/2019 7551 835 Body 0.991 54.104 PASS PASS PASS GMSK PASS N/A I 1750 4/7/2020 7527 1750 Body 1.506 54.99 PASS PASS PASS N/A N/A N/A L 1750 8/16/2019 7410 1750 Body 1.467 53.429 PASS PASS PASS N/A N/A N/A H 1900 6/1/2020 7357 1900 Body 1.555 51.21 PASS PASS PASS GMSK PASS N/A J 1900 1/1/2020 7571 1900 Body 1.579 51.919 PASS PASS PASS GMSK PASS N/A K 2300 9/5/2019 7547 2300 Body 1.893 52.45 PASS PASS PASS N/A N/A N/A K 2450 9/6/2019 7547 2450 Body 1.996 51.898 PASS PASS PASS OFDM/TDD PASS PASS K 2600 9/5/2019 7547 2600 Body 2.176 52.04 PASS PASS PASS TDD PASS N/A G 5250 6/8/2020 7538 5250 Body 5.4 47.53 PASS PASS PASS OFDM N/A PASS G 5600 6/8/2020 7538 5600 Body 5.857 46.97 PASS PASS PASS OFDM N/A PASS G 5750 6/8/2020 7538 5750 Body 6.061 46.723 PASS PASS PASS OFDM N/A PASS CW VALIDATION MOD. VALIDATION SAR SYSTEM # FREQ. [MHz] DATE PROBE SN PROBE CAL. POINT COND.PERM. (σ)(εr)SENSITIVITY PROBE LINEARITY PROBE ISOTROPY MOD. TYPE DUTY FACTORPAR I17504/7/202075271750Body1.50654.99PASSPASSPASSN/AN/AN/A L17508/16/201974101750Body1.46753.429PASSPASSPASSN/AN/AN/A J19001/1/202075711900Body1.57951.919PASSPASSPASSGMSKPASSN/A K23009/5/201975472300Body1.89352.45PASSPASSPASSN/AN/AN/A K24509/6/201975472450Body1.99651.898PASSPASSPASSOFDM/TDDPASSPASS K26009/5/201975472600Body2.17652.04PASSPASSPASSTDDPASSN/A G52506/8/202075385250Body5.447.53PASSPASSPASSOFDMN/APASS G56006/8/202075385600Body5.85746.97PASSPASSPASSOFDMN/APASS G57506/8/202075385750Body6.06146.723PASSPASSPASSOFDMN/APASS CW VALIDATIONMOD. VALIDATION SAR SYSTEM # FREQ. [MHz]DATEPROBE SNPROBE CAL. POINT
FCC ID: A3LSMN981W SAR EVALUATION REPORT Reviewed by: Quality Manager Test Dates: DUT Type: APPENDIX G: Page 1 of 5 06/03/20 - 07/13/20 Portable Handset © 2020 PCTEST REV 20.05 M 11/15/2017 APPENDIX G P O W E R R E D U C T I O N V E R I F I C A T I O N Per the May 2017 TCBC Workshop Notes, demonstration of proper functioning of the power reduction mechanisms is required to support the corresponding SAR configurations. The verification process was divided into two parts: (1) evaluation of output power levels for individual or multiple triggering mechanisms and (2) evaluation of the triggering distances for proximity-based sensors. G.1 Power Verification Procedure The power verification was performed according to the following procedure: 1. A base station simulator was used to establish a conducted RF connection and the output power was monitored. The power measurements were confirmed to be within expected tolerances for all states before and after a power reduction mechanism was triggered. For licensed modes, the device state index as displayed on the device UI was recorded before and after the mechanism was triggered. 2. Step 1 was repeated for all relevant modes and frequency bands for the mechanism being investigated. 3. Steps 1 and 2 were repeated for all individual power reduction mechanisms and combinations thereof. For the combination cases, one mechanism was switched to a 'triggered' state at a time; powers were confirmed to be within tolerances after each additional mechanism was activated. G.2 Distance Verification Procedure The distance verification procedure was performed according to the following procedure: 1. A base station simulator was used to establish an RF connection and to monitor the power levels. The device being tested was placed below the relevant section of the phantom with the relevant side or edge of the device facing toward the phantom. For licensed modes, the device state index on the device UI was monitored to determine the triggering state. 2. The device was moved toward and away from the phantom to determine the distance at which the mechanism triggers and the output power is reduced, per KDB Publication 616217 D04v01r02 and FCC Guidance. Each applicable test position was evaluated. The distances were confirmed to be the same or larger (more conservative) than the minimum distances provided by the manufactur…
Text truncated - open the document above for the full version.
7185 Oakland Mills Road · Columbia · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 26 | 27 | 2.50 GHz - 2.69 GHz | 166.00 mW | 97M5W7D | 2.5 ppm |
Portable Handset
Equipment Class
CXX - Communications Rcvr for use w/ licensed Tx and CBsPortable Handset
Equipment Class
6VL - 15E 6 GHZ Very Low Power DeviceBT,BLE Tablet DTS,UNII a,b,g,n,ac,ax,be and digitizer
Equipment Class
DTS - Digital Transmission SystemPortable Handset
Equipment Class
6CD - 15E 6 GHz Low Power Dual ClientBT,BLE Tablet DTS,UNII a,b,g,n,ac,ax and Digitizer
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter