FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhejiang Feishen Vehicle Co., LTD./
  3. A6E-FSH9223

A6E-FSH92232CH 2.4GHz transmitter

Zhejiang Feishen Vehicle Co., LTD.
2CH 2.4GHz transmitter - FCC ID A6E-FSH9223 - Zhejiang Feishen Vehicle Co., LTD.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 04, 2026
Application Purpose
Original Equipment
Equipment Note
2CH 2.4GHz transmitter
Frequency Range
2410.00000000 - 2465.00000000
Company
Zhejiang Feishen Vehicle Co., LTD.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

(ZhejiangFeishenVehicleCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:September01,2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:A6E-FSH9223 ZhejiangFeishenVehicleCo.,Ltdcertifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903of theFCCrules. ZhejiangFeishenVehicleCo.,Ltdcertifiesthattheequipmentforwhichauthorizationissoughtdoesnot includecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofits successorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, JianFengDing/chiefinspector ZhejiangFeishenVehicleCo.,Ltd (ZhejiangFeishenVehicleCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:September01,2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:A6E-FSH9223 ZhejiangFeishenVehicleCo.,Ltdcertifiesthat,asofthedateofthefilingoftheapplication,theapplicant isnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiariesoraffiliates) asanentityproducing“covered”equipment. Sincerely, JianFengDing/chiefinspector ZhejiangFeishenVehicleCo.,Ltd

Attestation Statements

Zhejiang Feishen Vehicle Co.,Ltd U.S. Agent Designation for Service of Process - Certification Attestation Letter August 31, 2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: A6E-FSH9223 Applicant FRN: 0021413851 Zhejiang Feishen Vehicle Co.,Ltd certifies that, as of the date of the filing of the application, Global Product Services and Consultation LLC is our designated U.S. agent for service of process for the above referenced FCC ID. Zhejiang Feishen Vehicle Co.,Ltd accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Global Product Services and Consultation LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Global Product Services and Consultation LLC FCC Registration Number (FRN): 0033406703 Physical U.S. Company Address: 328 W Palm Ave. Monrovia, CA91016 Contact Person: Michael Chan Cell Phone : 626-366-4358 Agent Email Address: [email protected] Company: Zhejiang Feishen Vehicle Co.,Ltd Designated Agent: Global Product Services and Consultation LLC Company Representative: JianFeng Ding Designated Agent Representative: Michael Chan Title: chief inspector Signature: Title: Technical Director Signature: Date : 09/02/2026 SC : 6091029

Cover Letter(s)

(ZhejiangFeishenVehicleCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationof FCCID:A6E-FSH9223 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName Blockdiagram, Schematic, OperationalDescription Blockdiagram.pdf, Schematic.pdf, OperationalDescription.pdf Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. PursuanttoDA04-1705June15,2004oftheCommission’spublicnotice,wealsorequest temporaryconfidentialtreatmentofinformationaccompanyingthisapplicationasoutlinedbelow: Short-termconfidentialityrequested:180days ExhibitTypeFileName Internalphotos, Testsetupphotos, UserManual Internalphotos.pdf, Testsetupphotos.pdf, UserManual.pdf Sincerely, JianFengDing/chiefinspectorSeptember01,2026 ZhejiangFeishenVehicleCo.,Ltd

Cover Letter(s)

(ZhejiangFeishenVehicleCo.,Ltd) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Date:September01,2026 SUBJECT:FCCApplicationforFCCID:A6E-FSH9223 ToWhomItMayConcern: We,theundersigned,herebyauthorizeTonyWeiatEMTEK(NINGBO)CO.,LTD.onour behalf,toapplytotheFederalCommunicationsCommissiononourequipment.Anyand allactscarriedoutbyEMTEK(NINGBO)CO.,LTD.onourbehalfshallhavethesame effectasactsofourown. ThisistoadvisethatweareinfullcompliancewiththeAnti-DrugAbuseAct.We,the applicant,arenotsubjecttoadenialoffederalbenefitspursuanttoSection5301ofthe Anti-DrugActof1988,21USC853a,andnopartytotheapplicationissubjecttoadenial offederalbenefitspursuanttothatsection. Regards, JianFengDing/chiefinspector ZhejiangFeishenVehicleCo.,Ltd

External Photos

Report No.: Ti-EE26080198-AW 1 / 3 EUT EXTERNAL PHOTOS FRONT VIEW OF EUT REAR VIEW OF EUT Report No.: Ti-EE26080198-AW 2 / 3 LEFT VIEW OF EUT RIGHT VIEW OF EUT Report No.: Ti-EE26080198-AW 3 / 3 TOP VIEW OF EUT BOTTOM VIEW OF EUT --BLANK BELOW--

ID Label/Location Info

A6E-FSH9223

RF Exposure Info

Report No.: Ti-EE26080198-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 34 Web: www.titcgroup.com Template No.: TRP-FCC DASY-Body-2 (2026-04-30) Add: 601, Building 2, Intelligent Connected Vehicle Industrial Park, No.55, Xiangshan Road, Luotian Community, Yanluo Sub-district, Bao'an District, Shenzhen TEST REPORT Applicant: Zhejiang Feishen Vehicle Co., Ltd. Address: North Lake Road Hardware Science And Technology In Zheliang Province. Equipment Type: 2CH 2.4GHz transmitter Model Name: FSH9223 Brand Name: FS FCC ID: A6E-FSH9223 Test Standard: FCC 47 CFR Part 2.1093 (refer to section 3.1) Maximum SAR: Body 2.4GHz(1 g): 0.31 W/kg Limbs 2.4GHz(10 g): 0.13 W/kg Sample Arrival Date: Aug. 10, 2026 Test Date: Aug. 13, 2026 Date of Issue: Aug. 27, 2026 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Liu Haibo Checked by: Xu Rui Approved by: Liao Jianming (Technical Director) _______________ _______________ _______________ Report No.: Ti-EE26080198-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 34 Web: www.titcgroup.com Template No.: TRP-FCC DASY-Body-2 (2026-04-30) Add: 601, Building 2, Intelligent Connected Vehicle Industrial Park, No.55, Xiangshan Road, Luotian Community, Yanluo Sub-district, Bao'an District, Shenzhen Revision History Version Issue Date Revisions Content Rev. 01 Aug. 27, 2026 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ........................................................................................................ 4 1.1 Test Laboratory ............................................................................................................ 4 1.2 Test Location ................................................................................................................ 4 1.3 Test Environment Condition .......................................................................................... 4 2 PRODUCT INFORMATION ....................................................................................................... 5 2.1 Applicant Information .................................................................................................... 5 2.2 Manufacturer Information .............................................................................................. 5 2.3 General Description for Equipment under Test (EUT) ................................................... 5 2.4 Ancillary Equipment ...................................................................................................... 5 2.5 Technical Information ................................................................................................... 6 2.6 Antenna Location .......................................................................................................... 7 3 SUMMARY OF TEST RESULT ................................................................................................. 8 3.1 Test Standards ............................................................................................................. 8 3.2 Device Category and SAR Limit ................................................................................... 9 3.3 Test Result Summary ................................................................................................. 10 3.4 Test Uncertainty ......................................................................................................... 11 4 MEASUREMENT SYSTEM ..................................................................................................... 12 4.1 Specific Absorption Rate (SAR) Definition .................................................................. 12 4.2 DASY SAR System .................................................................................................... 13 5 SYSTEM VERIFICATION ........................................................................................................ 20 5.1 Purpose of System Check .......................................................................................... 20 5.2 System Check Setup .................................................................................................. 20 6 TEST POSITION CONFIGURATIONS .................................................................................... 21 6.1 Body-worn Position Conditions ................................................................................... 21 Report No.: Ti-EE26080198-701 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 34 Web: www.titcgroup.com Template No.: TRP-FCC DASY-Body-2 (2026-04-30) Add: 601, Building 2, Intelligent Connected Vehicle Industrial Park, No.55, Xiangshan Road, Luotian Community, Yanluo Sub-district, Bao'an District, Shenzhen 6.2 Limb-worn Position Conditions ................................................................................... 21 7 MEASUREMENT PROCEDURE ............................................................................................. 22 7.1 Measurement Process Diagram ................................................................................. 22 7.2 SAR Scan General Requirement ................................................................................ 23 7.3 Measurement Procedure ............................................................................................ 24 7.4 Area & Zoom Scan Procedure .................................................................................... 24 8 CONDUCTED RF OUTPUT POWER ...................................................................................... 25 9 TEST RESULT ........................................................................................................................ 26 9.1 2.4G ISM Band ........................................................................................................... 27 10 SAR Measurement Variability .................................................................................................. 28 11 SIMULTANEOUS TRANSMISSION .......................…

Text truncated - open the document above for the full version.

RF Exposure Info

ReportNo.:Ti-EE26080198-AC 1 / 32 CALIBRATIONREPORT F.1E-FieldProbe(EX3DV4-SN:7510) ReportNo.:Ti-EE26080198-AC 2 / 32 ReportNo.:Ti-EE26080198-AC 3 / 32 ReportNo.:Ti-EE26080198-AC 4 / 32 ReportNo.:Ti-EE26080198-AC 5 / 32 ReportNo.:Ti-EE26080198-AC 6 / 32 ReportNo.:Ti-EE26080198-AC 7 / 32 ReportNo.:Ti-EE26080198-AC 8 / 32 ReportNo.:Ti-EE26080198-AC 9 / 32 ReportNo.:Ti-EE26080198-AC 10 / 32 ReportNo.:Ti-EE26080198-AC 11 / 32 ReportNo.:Ti-EE26080198-AC 12 / 32 ReportNo.:Ti-EE26080198-AC 13 / 32 ReportNo.:Ti-EE26080198-AC 14 / 32 ReportNo.:Ti-EE26080198-AC 15 / 32 ReportNo.:Ti-EE26080198-AC 16 / 32 ReportNo.:Ti-EE26080198-AC 17 / 32 ReportNo.:Ti-EE26080198-AC 18 / 32 ReportNo.:Ti-EE26080198-AC 19 / 32 ReportNo.:Ti-EE26080198-AC 20 / 32 ReportNo.:Ti-EE26080198-AC 21 / 32 ReportNo.:Ti-EE26080198-AC 22 / 32 ReportNo.:Ti-EE26080198-AC 23 / 32 F.2DataAcquisitionElectronics(DAE4-SN:1711) ReportNo.:Ti-EE26080198-AC 24 / 32 ReportNo.:Ti-EE26080198-AC 25 / 32 ReportNo.:Ti-EE26080198-AC 26 / 32 F.32450MHzDipole ReportNo.:Ti-EE26080198-AC 27 / 32 ReportNo.:Ti-EE26080198-AC 28 / 32 ReportNo.:Ti-EE26080198-AC 29 / 32 ReportNo.:Ti-EE26080198-AC 30 / 32 ReportNo.:Ti-EE26080198-AC 31 / 32 ReportNo.:Ti-EE26080198-AC 32 / 32 D2450V2DipoleimpedanceandreturnlossValidation Meas.ResultsCurrentMeas.PreviousMeas.Max.Deviation Meas.Data2026.05.062025.05.06/ ReturnLoss(dB)-24.133-27.271-11.51% Impedance 51.716Ω+5.464 jΩ 51.780Ω+5.716 jΩ -0.252Ω (Imaginarypart) ReturnLoss Impedance --ENDOFREPORT--

RF Exposure Info

8 CONDUCTED RF OUPUT POWER 8.1 2.4G Hopping Output Power Ti-EE26080198-AP 1/2 8.12.4G Hopping Output Power 2.4G Hopping-Ant.1 2.4G ModeChannal Frequency (MHz) Conducted power (dBm) Tune up (dBm) SAR Test GFSK Low241013.5715.00Yes Mid243714.8116.00Yes High246515.7317.00Yes Ti-EE26080198-AP 2/2

RF Exposure Info

Ti-EE26080198-ASC 1/1 SystemCheck:Head2450MHz ExposureConditions Phantom Section,TSL Position, Test Distance [mm] BandGroup, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Ambient Temperature [°C] Liquid Temperature [°C] Flat, HSL Validation band CW, 0-- 2450.0, 2450 7.711.7838.622.321.4 HardwareSetup PhantomTSL,MeasuredDateProbe,CalibrationDateDAE,CalibrationDate Twin-SAMV8.0(30degprobetilt)- 2090 HBBL-600-100002026-08-13EX3DV4-SN7510,2025-11-11DAE4Sn1711,2025-11-11 ScanSetup AreaScanZoomScan GridExtents[mm]80.0x80.030.0x30.0x30.0 GridSteps[mm]10.0x10.05.0x5.0x1.5 SensorSurface[mm]3.01.4 GradedGridYesYes GradingRatio1.51.5 MAIAN/AN/A SurfaceDetectionVMS+6pVMS+6p ScanMethodMeasuredMeasured MeasurementResults AreaScanZoomScan Date2026-08-132026-08-13 psSAR1g[W/kg]5.315.36 psSAR10g[W/kg]2.282.39 PowerDrift[dB]0.08-0.03 PowerScalingDisabledDisabled ScalingFactor[dB] TSLCorrectionNocorrectionNocorrection M2/M1[%]71.4 Dist3dBPeak[mm]9.6 --BLANKBELOW--

RF Exposure Info

ReportNo.:Ti-EE26080198-AT 1 / 1 NormalModeRFPowerRange(2.4GHopping) Band(GHz)ModeChannelFreq.(MHz)Range(dBm) 2.4GFSK Low2410 [13.00,15.00] Mid2437 [14.00,16.00] High2465 [15.00,17.00] --BLANKBELOW--

RF Exposure Info

Ti-EE26080198-ATD-2 1 Meas.1BodyPlanewithFrontSide0mmonLowChannelin2.4GHoppingmodewithAntenna1 ExposureConditions Phantom Section,TSL Position, TestDistance [mm] BandGroup, UID Frequency [MHz], Channel Number Conversion Factor TSL Conductivity [S/m] TSL Permittivity Ambient Temperature [°C] Liquid Temperature [°C] Flat, HSL FRONT, 0.00 D2450CW, 0-- 2410.0, 10 7.711.7340.122.321.4 HardwareSetup PhantomTSL,MeasuredDateProbe,CalibrationDateDAE,CalibrationDate Twin-SAMV8.0(30degprobetilt)- 2090 HBBL-600-100002026-08-13EX3DV4-SN7510,2025-11-11DAE4Sn1711,2025-11-11 ScanSetup AreaScanZoomScan GridExtents[mm]96.0x216.030.0x30.0x30.0 GridSteps[mm]12.0x12.05.0x5.0x5.0 SensorSurface[mm]3.01.4 GradedGridYesYes GradingRatio1.51.5 MAIAYY SurfaceDetectionVMS+6pVMS+6p ScanMethodMeasuredMeasured MeasurementResults AreaScanZoomScan Date2026-08-132026-08-13 psSAR1g[W/kg]0.0370.041 psSAR10g[W/kg]0.0160.018 PowerDrift[dB]0.000.12 PowerScalingDisabledDisabled ScalingFactor[dB] TSLCorrectionNocorrectionNocorrection M2/M1[%]45.5 Dist3dBPeak[mm]15.0

Test Report

深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  1 FeishengElectronicsCo.,Ltd. Address:FeishengElectronics,3rdFloor,BuildingA8,GuangxingtengIndustrialPark,Longdong Community,BaolongStreet,LonggangDistrict,Shenzhen Phonenumber:0755-85218289FAX:0755-85223189 AntennaSpecificationApprovalDocument CUSTOMERNAME : NingBoJingRunControlTechnologyCo.,Ltd CustomerMaterialCode:/ TYPENAME:FS-WZ-TG-074 SPECIFICATON : CopperTubeAntenna-2.4G-1.13IPEXGen1 Connector-1.13Cable-DualSilvercable-Gray-L=130MM 一、NewlyApproved 二、MaterialApproved 三、SPECApproved Manufacturer/SupplierR&D Acknowledgment CustomerConfirmation  (APPROVALBY): ( APPROVALBY ): (APPROVALDATE):2026-03-16(APPROVALDATE): SUPPLIERCUSTOMER RF:Structures:BusinessTESTEDCHECKEDAPPROVED GuoXiXuLongGuZhifei SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  2 INDEX. 1)Covercover.................................................................................1 2)Catalog........................................................................................2 3)2Ddrawings................................................................................3 4)Productspecificationparameters................................................4 5)Testreportofpassivewaveformlossvalue..............................5-9 6)Environmentaltestreport.....................................................10-13 Modifytherecord VersionsDatesRFModifythecontent A02026-03-16HuYongqi SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD.  3 SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  4 ProductFeaturesSpecificationTable 一、Basiccharacteristicsoftheproduct: DESCRIPTIONVALUE FrequencyRange2400-2500MHz Impedance50Ω VSWRComparingWaveforms Gain2.84DBi RadiationOmni-directional PolarizationlinearVertical ConnectormodelI-PEX(MHFI) Operatingtemperature-40°C~+85°C Storagetemperature-45 °C ~+85 °C SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  5 Testdataandgraphs 1.Summary: ThisreporttoaccountforthemeasurementsetupandresultoftheAntenna.Themeasurement setupincludess-parameter,ThemeasureddataforAntennaarepresentedandanalysis. 2.S-ParameterMeasurementS: A.Reflectioncoefficient: (a)Instrument:NetworkAnalyzer (b)Setup: (1)CalibratetheNetworkAnalyzerbyoneportcalibrationusingO.S.L.calibrationkits. (2)ConnecttheantennaundertesttotheNetworkAnalyzer. (3)MeasuretheS11(reflectioncoefficient)showninFig.1. (4)Generally,theS11islessthan–10dBtoensurethe90%VSWR2.0:1powerinto antennaandonlylessthan10%powerbacktosystem. 一 Fig.1AntennameasuredinNetworkAnalyzer SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  6 3.S-ParameterMeasurementResultS: S-Parametertestdata: S-Parametertestimage: FrequencyMHz 240024502500 LossDBvalue1.381.391.75 SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  7 Productactualphoto: Darkroomtestenvironment: SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  8 Passivevalues: 2D/3D: SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  9 SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. SHENZHEN FEISHENG ELECTRONICS CO.,LTD. 深圳市飞胜电子有限公司 SHENZHENFEISHENGELECTRONICSCO.,LTD.  10 Environmentaltestrequirements PrefaceTestitemsTestmethodsandconditionsTestequipmentTestresults 1 Temperature and humidity test ReferenceE1A364-31MethodThree,Test ConditionA Thepurposeofthistestprocessisto conductdetailedstandardtests.The productsusedareaffectedbyhigh humidityandheat.Influencethe performanceofthematerialfor evaluation. K.SONINS THS-A4L-150 Qualified Requirements: Temperature:85°C Humidity:90~95%(R.H) Time:72hours 2 Low temperature test RefertoFeishengElectronicTest Specification Themeasuredsampleshouldbetraveledin atemperature-balancedenvironment,and itstemperaturesetting Se…

Text truncated - open the document above for the full version.

Test Report

ReportNo.ENB2606290089W00101RPage1of52Ver.1.0 TESTREPORT ProductName:2CH2.4GHztransmitter ModelNumber:FSH9223 FCCID:A6E-FSH9223 Preparedfor:ZhejiangFeishenVehicleCo.,Ltd Address:NorthLakeRoadHardwareScienceAndTechnologyIn, Yongkang,ZheJiangProvince,China Preparedby:EMTEK(NINGBO)CO.,LTD. Address:BNo.8,Building8,Lane216,QingyiRoad,Ningbo High-TechZone,Ningbo,Zhejiang,China Tel:+86-574-27907998 Fax:+86-574-27721538 ReportNumber:ENB2606290089W00101R Date(s)ofTests:July01,2026toJuly25,2026 Dateofissue:July26,2026 $ 二维码 $ ReportNo.ENB2606290089W00101RPage2of52Ver.1.0 TableofContents 1TESTRESULTCERTIFICATION..........................................................................................................................................3 2EUTTECHNICALDESCRIPTION.......................................................................................................................................5 3SUMMARYOFTESTRESULT.............................................................................................................................................6 4TESTMETHODOLOGY........................................................................................................................................................7 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS.............................................................................................7 4.2MEASUREMENTEQUIPMENTUSED.........................................................................................................................7 4.3DESCRIPTIONOFTESTMODES.................................................................................................................................9 5FACILITIESANDACCREDITATIONS..............................................................................................................................10 5.1FACILITIES...................................................................................................................................................................10 5.2EQUIPMENT.................................................................................................................................................................10 5.3LABORATORYACCREDITATIONSANDLISTINGS...............................................................................................10 6TESTSYSTEMUNCERTAINTY.........................................................................................................................................11 7SETUPOFEQUIPMENTUNDERTEST............................................................................................................................12 7.1RADIOFREQUENCYTESTSETUP1........................................................................................................................12 7.2RADIOFREQUENCYTESTSETUP2........................................................................................................................12 7.3CONDUCTEDEMISSIONTESTSETUP....................................................................................................................14 7.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM....................................................................................15 7.5SUPPORTEQUIPMENT...............................................................................................................................................15 8FREQUENCYHOPPINGSYSTEMREQUIREMENTS.....................................................................................................16 8.1StandardApplicable........................................................................................................................................................16 8.2EUTPseudorandomFrequencyHoppingSequence.......................................................................................................16 8.3EqualHoppingFrequencyUse.......................................................................................................................................17 8.4FrequencyHoppingSystem............................................................................................................................................17 9TESTREQUIREMENTS......................................................................................................................................................18 9.120DB&99%BANDWIDTH............................................................................................................................................18 9.2CARRIERFREQUENCYSEPARATION.....................................................................................................................23 9.3NUMBEROFHOPPINGFREQUENCIES...................................................................................................................25 9.4AVERAGETIMEOFOCCUPANCY(DWELLTIME)................................................................................................27 9.5MAXIMUMPEAKCONDUCTEDOUTPUTPOWER...............................................................................................29 9.6CONDUCTEDSUPRIOUSEMISSION........................................................................................................................31 9.7RADIATEDSPURIOUSEMISSION............................................................................................................................38 9.8CONDUCTEDEMISSIONTEST.................................................................................................................................51 9.9ANTENNAAPPLICATION...........................................................................................................................................52 ReportNo.ENB2606290089W00101RPage3of52Ver.1.0 1TESTRESULTCERTIFICATION Applicant:ZhejiangFeishenVehicleCo.,Ltd Address:NorthLakeRoadHardwareScienceAndTechnologyIn,Yongkang,ZheJiang Province,China Manufacturer:ZhejiangFeishenVehicleIndustryCo.,Ltd. Address:98BeihuRoadHardwareScientificandTechnologic…

Text truncated - open the document above for the full version.

Contact Information

Applicant

JianFeng Ding
[email protected]Fax: 86-579-87295396

Technical Contact

Global Product Services and Consultation LLCMichael Chan
[email protected]

328 W Palm Ave. · Monrovia, California, 91016 · United States

Test Firm

EMTEK (NINGBO) Co., Ltd.Tony Wei
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz37.40 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. The highest reported SAR for body and product specific (10 g extremity) exposure conditions are 0.31 W/kg and 0.13 W/kg, respectively.

Other Applications from Zhejiang Feishen Vehicle Co., LTD.

Remote Controller - FCC ID A6E-GT15 - Zhejiang Feishen Vehicle Co., LTD.
A6E-GT15

Remote Controller

May 18, 2020

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
QUADTRANSMITTER - FCC ID A6E-FSHTX - Zhejiang Feishen Vehicle Co., LTD.
A6E-FSHTX

QUADTRANSMITTER

May 01, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
QUADCOPTER - FCC ID A6E-FSHRX - Zhejiang Feishen Vehicle Co., LTD.
A6E-FSHRX

QUADCOPTER

May 01, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
2.4 GHz Digital Proportional R/C System - FCC ID A6EZJFSH62832 - Zhejiang Feishen Vehicle Co., LTD.
A6EZJFSH62832

2.4 GHz Digital Proportional R/C System

Mar 08, 2012

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified