Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Freedom-Air 2.0 Dual Remote Wireless Interchangeable Inflator Pump Operation Instruction Operation Instruction: 1. Plug in the pump, the power indicator will flash slowly for 30 seconds and then stops flashing which means the system is in standby mode. (Within 30 seconds, press any button to light LCD, then pressing “FIRM” button for 3 seconds will start to resync. LCD will display “SU” when the pump and remote are synced again successfully and enter the standby mode. The power indicator will flash when the pump is working. 2. Press any button to light LCD for operation. If there is no operation after 15 seconds LCD will turn off automatically to save battery life. 3. LEFT/RIGHT: press “LEFT/RIGHT” button to select left side or right side air chamber for further operation. LCD will show “L” or “R” accordingly. 4. FIRM: press “FIRM” button for one time, the pump will be activated to inflate and the pressure level shown on LCD will increase relative to pressure in air chamber, and scroll bar will scroll up to show that the pressure is increasing. At any time during the period of inflation, pressing any button will stop the inflation. Or when the pressure reaches the maximum (“50” on LCD), the inflation will stop automatically. 5. SOFT: press “SOFT” button, the pump will be activated to deflate and the pressure level shown on LCD Memory 1 Pressure Scroll Bar SOFT Left Memory 1 SST Pressure Level FIRM Memory 2 LEFT/RIGHT Right Memory 2 Low Battery Capacity will decrease relative to pressure in air chamber, and scroll bar will scroll down to show that the pressure is decreasing. At any time during the period of deflation, pressing any button will stop the deflation. Or when the pressure reaches the minimum (“0” on LCD), the deflation will stop automatically. 6. Memory: press “MEM1” or “MEM2” button, LCD will show “M1” or “M2” and the pump will be activated to inflate or deflate until the pressure in air chamber reaches the level memorized. When the pump is inflating or deflating to the level memorized, pressing any button will still stop inflation or deflation. 7. Setting Memory Level: when LCD shows a pressure level readout, before or after inflation or deflation, press and hold “MEM1” or “MEM2” button for 3 seconds, M1 or M2 indicator will flash and the current pressure level will be kept as a new memory level. The memory level for left or right side air chamber can be set in the same way, to be same or different. The default MEM1 level is 25mmHg (“25” on LCD). The default MEM2 level is 20 mmHg (“20” on LCD). 8. Smart Support Technology:SST is enabled by default to maintain level last selected or memory setting for continuous comfort. SST may be disabled/enabled by pressing “LEFT/RIGHT” for 3 seconds then, while still pressing “LEFT/RIGHT” button, quickly pressing “FIRM” button at which time LCD will display F1, at this time pressing “LEFT/RIGHT” will turn SST off or on. When disabled SST symbol will not show in the LCD display. 9. Actual Pressure Check: press and hold “LEFT/RIGHT” for 3 seconds then, while still pressing “LEFT/RIGHT L” button, quickly pressing “MEM2” button, LCD will display the actual pressure in air chamber and the pressure scroll bar will flash. The display of actual pressure will turn off after 15 seconds automatically or by pressing any button. 10. Special Note: A) The Max. pressure is 50mmHg. B) The pump will automatically stop after working continuously for 10 minutes. C) Real-time Pressure readout has a 10 mmHg margin when starting inflation, however, the real-time pressure will be displayed directly when it is lower than 10mmHg. After checking the actual pressure, the actual pressure will be treated as the last set level. D) Air Chamber Dimension Detection: to display the pressure level in air chamber accurately, Freedom-Air 2.0 Wireless Inflator Pump has a function to measure and record air chamber dimension automatically when it works in the first few times. Such a measurement can also be done manually by pressing “LEFT/RIGHT” button for 3 seconds then, while still pressing “LEFT/RIGHT” button, quickly pressing “SOFT” button at which time LCD will display AD and the inflator pump will start the measurement. It takes about 10 minutes to do such a measurement. 11. Troubleshooting: A) Range: wireless remote control range is 15-30' (5-10m) so if out of range the controller will show “Er”. B) Sync: while remotes are synced before delivery, if “Er” continues to show on LCD or when the wireless remote is replaced, please resync. To resync, disconnect power to the pump, then power it on again, the power indicator will flash slowly for 30 seconds. Within 30 seconds, press any button to light LCD, then press down “FIRM” button for 3 seconds and when the LCD shows “SU” the pump and remote are synced again successfully. C) Batteries: The remote is powered by three AAA-LR03-1.5V batteries. When the battery power is low, the LCD will show low battery capacity alert so please replace the batteries. If remote will not be used for a long time, please remove batteries. FCC Caution: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that …
Text truncated - open the document above for the full version.
NINGBO FOREVER ELECTRONIC APPLIANCE CO., LTD. 2023.04.28 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for A7GFAP-FA2 [NINGBO FOREVER ELECTRONIC APPLIANCE CO., LTD.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (Applicant signature) (Applicant printed name): MR.SHEN NINGBO FOREVER ELECTRONIC APPLIANCE CO., LTD. 2023.04.28 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for A7GFAP-FA2 [NINGBO FOREVER ELECTRONIC APPLIANCE CO., LTD. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name): MR.SHEN
Ningbo Forever Electronic Appliance Co., Ltd U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: InnoMax Corporation FRN: 0033750027 Contact Name: Irvin Saathoff Address: 530 West Elk Place, Denver, COLORADO 80216 Telephone No: 303-292-5846 Email: [email protected] This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature: Date:2023-05-06 Signed by (Printed Name/Title): Irvin Saathoff /Manager The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Ningbo Forever Electronic Appliance Co., Ltd FCC ID:A7GFAP-FA2 Contact Name: MR.SHEN Address: NO.375, NINGCHUAN ROAD, NINGBO, ZHEJIANG, CHINA Telephone No: +86-574-87801335 Email: [email protected] Applicant Signature: Date: 2023-05-06 Signed by (Printed Name/Title): MR.SHEN /Manager
NINGBO FOREVER ELECTRONIC APPLIANCE CO., LTD. 2023.04.28 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: Inflator Pump Trademark: N/A MODEL: FAP-FA2, FAPBT-FA2, FAP-FA3, FAPBT-FA3, FAP4-FA4, FAP4BT- FA4, FAP4-FA5, FAP4BT-FA5 FCC ID:A7GFAP-FA2 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : MR.SHEN/ Manager Contact information / address: NO.375, NINGCHUAN ROAD, NINGBO, ZHEJIANG, CHINA
NINGBO FOREVER ELECTRONIC APPLIANCE CO., LTD. 2023.04.28 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Shenzhen BCTC Testing Co., Ltd to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : MR.SHEN/ Manager Contact information / address: NO.375, NINGCHUAN ROAD, NINGBO, ZHEJIANG, CHINA
NINGBO FOREVER ELECTRONIC APPLIANCE CO., LTD. Model Difference 2023.04.28 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA RE: LETTER OF MODEL DIFFERENCE EUT NAME: Inflator Pump Trademark: N/A MODEL: FAP-FA2, FAPBT-FA2, FAP-FA3, FAPBT-FA3, FAP4-FA4, FAP4BT-FA4, FAP4-FA5, FAP4BT-FA5 FCC ID:A7GFAP-FA2 All the model are the same circuit and RF module, except model names. Sincerely Client’s signature: Client’s name / title : MR.SHEN/ Manager Contact information / address: NO.375, NINGCHUAN ROAD, NINGBO, ZHEJIANG, CHINA
External Photos
Label & label location 20 mm*10mm FCC ID:A7GFAP-FA2 Label location
Internal Photos Antenna
RF EXPOSURE EVALUATION METHOD FCC ID:A7GFAP-FA2 Applicable standard: In accordance with FCC 47 CFR part 2 (2.1093) this device has been defined as a portable device which is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable devices must be evaluated using the specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEEC95.1-1992. and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2003. Per FCC KDB 447498 D01 v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances s 50 mm are determined by: SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Modulation Test Channel Output Power (dBm) Limit (dBm) GFSK 2423MHz -4.840 21 GFSK 2439MHz -4.738 21 GFSK 2450MHz -4.444 21 max possible output power (PK,conducted):-4±1dBm 2.3dBi logarithmic terms convert to numeric result is nearly 1.698 -3dBm=0.50mW 2423MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]=0.50/5*√2.423 =0. 16≤3.0 2439 MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 0.50/5*√2.439 =0.16≤3.0 2450MHz [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,mm)] · [√f(GHz)]= 0.50/5*√2. 450 =0. 16≤3.0 Conclusion: 1. [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] < 3.0. 2. SAR Test Exclusion Thresholds is 3.0 for separation distance 5mm. Therefore, SAR test is not required.
1. AntennaDescription: AntennaplateMonopoleAntenna Antennapeakgain2.3dBi Frequencyrange2400MHz~2500MHz ConnecttypeDirectConnect 2.Antenna Size: 3. Antenna Radiation Pattern Radiation pattern @2.402GHz Manufacturer: Anhui Hong Xin Electronic Technology Co., Ltd Address: China PCB Industrial Park Economic Development Zone Guangde County, Anhui 242200 China. [email protected] [email protected]
No.:BCTC/RF-EMC-005 Page: 1 of 38 Edition:A.5 TEST REPORT Shenzhen BCTC Testing Co., Ltd. Report No.: BCTC2304725712E Applicant: Ningbo Forever Electronic Appliance Co., Ltd Product Name: Inflator Pump Model/Type Ref.: FAP-FA2 Tested Date: 2023-04-12 to 2023-04-23 Issued Date: 2023-04-23 Report No.: BCTC2304725712E No.:BCTC/RF-EMC-005 Page: 2 of 38 Edition:A.5 FCC ID:A7GFAP-FA2 The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen BCTC Testing Co., Ltd, this report can’t be reproduced except in full. The tested sample(s) and the sample information are provided by the client. Product Name: Inflator Pump Trademark: N/A Model/Type Ref.: FAP-FA2 FAPBT-FA2, FAP-FA3, FAPBT-FA3, FAP4-FA4, FAP4BT-FA4, FAP4-FA5, FAP4BT-FA5 Prepared For: Ningbo Forever Electronic Appliance Co., Ltd Address: NO.375, NINGCHUAN ROAD, NINGBO, ZHEJIANG, CHINA Manufacturer: Ningbo Forever Electronic Appliance Co., Ltd Address: NO.375, NINGCHUAN ROAD, NINGBO, ZHEJIANG, CHINA Prepared By: Shenzhen BCTC Testing Co., Ltd. Address: 1-2/F., Building B, Pengzhou Industrial Park, No.158, Fuyuan 1st Road, Zhancheng, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: 2023-04-12 Sample tested Date: 2023-04-12 to 2023-04-23 Issue Date: 2023-04-23 Report No.: BCTC2304725712E Test Standards: FCC Part15.247 ANSI C63.10-2013 Test Results: PASS Tested by: Approved by: Jeff.Fu/Project Handler Zero Zhou/Reviewer Report No.: BCTC2304725712E No.:BCTC/RF-EMC-005 Page: 3 of 38 Edition:A.5 Table Of Content Test Report Declaration Page 1. Version .................................................................................................................. 5 2. Test Summary ....................................................................................................... 6 3. Measurement Uncertainty ..................................................................................... 7 4. Product Information And Test Setup ..................................................................... 8 4.1 Product Information ............................................................................................... 8 4.2 Test Setup Configuration ...................................................................................... 8 4.4 Channel List .......................................................................................................... 9 4.5 Test Mode ............................................................................................................. 9 4.6 Table Of Parameters Of Text Software Setting ................................................... 10 5. Test Facility And Test Instrument Used ............................................................... 11 5.1 Test Facility ......................................................................................................... 11 5.2 Test Instrument Used .......................................................................................... 11 6. Conducted Emissions .......................................................................................... 13 6.1 Block Diagram Of Test Setup .............................................................................. 13 6.2 Limit .................................................................................................................... 13 6.3 Test Procedure ................................................................................................... 13 6.4 EUT Operating Conditions .................................................................................. 14 6.5 Test Result .......................................................................................................... 14 7. Radiated Emissions ............................................................................................. 15 7.1 Block Diagram Of Test Setup .............................................................................. 15 7.2 Limit .................................................................................................................... 16 7.3 Test Procedure ................................................................................................... 17 7.4 EUT Operating Conditions .................................................................................. 18 7.5 Test Result .......................................................................................................... 18 8. Radiated Band Emission Measurement And Restricted Bands Of Operation ..... 22 8.1 Block Diagram Of Test Setup .............................................................................. 22 8.2 Limit .................................................................................................................... 22 8.3 Test Procedure ................................................................................................... 23 8.4 EUT operating Conditions ................................................................................... 23 8.5 Test Result .......................................................................................................... 24 9. Power Spectral Density Test ............................................................................... 25 9.1 Block Diagram Of Test Setup .............................................................................. 25 9.2 Limit .................................................................................................................... 25 9.3 Test Procedure ................................................................................................... 25 9.4 EUT Operating Conditions .................................................................................. 25 9.5 Test Result .......................................................................................................... 26 10. Bandwidth Test .........................…
Text truncated - open the document above for the full version.
Report No.: BCTC2304725712E No.:BCTC/RF-EMC-00 5 Page: 37 of 38 Edition:A.5 15. EUT Test Setup Photographs Radiated Measurement Photos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.42 GHz - 2.45 GHz | 360.00 µW |

Mattress Inflation Air Pump
Equipment Class
DTS - Digital Transmission System
Remote Control for Mattress Inflation Air Pump
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter