Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
2 3 1 Optical disc library system for long-term data archiving using Blu-ray disc™ technology DataArchiver unit(Preliminary) Sustainable storage Low T.C.O. Long term archiving Suitable for preserving valuable data •Less migration with long media life, 50-year longevity •Reducing the cost for data migration, operation cost, media purchasing and electric power Energy-saving and natural-resource-saving data preservation •No electric power required for media storage since the media can be preserved for long time in the office environment •No media disposal is necessary on data migration High data density/high capacity •12 BD-R discs held in ultra thin magazine makes 1.2TB/magazine and 108TB/unit maximum. •Magazine can be taken out from the unit and stored in a shelf. Magazine can be managed by RFID in it High performance •216MB/s read and write •200ms of access time DataArchiver unit and its media Characteristics System configuration examples NAS connection (CIFS protocol) Magazine shelf -Each magazine is managed by its RFID -Surveillance function with RFID -Door lock mechanism with user identification LAN DA Manager NAS head with magazine management function DataArchiver unit Client PC Example of generic IT sysme Server Archiving Video source VTRVideo ingestion system Data archiving system LAN SAS Filed video data DataArchiver unit Example of video archiving system :Video data flow
One Panasonic Way 4B-8 Secaucus, NJ 07094 Tel: 201-348-7758 / Fax: 201-392-4564
Request for Confidentiality Date: July 5, 2013 UL Japan, Inc. 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan FCC ID : ACJ-LB-DM9 Applicant : Panasonic Corporation of North America To whom it may concern: Please be advised that the following information is to be held confidential on behalf of us, referring to the FCC rules 0.457 and 0.459: Block Diagram Theory of Operation Schematics The application contains technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Sincerely, ご署名下さい。 Richard Mullen Group Manager Panasonic Corporation of North America One Panasonic Way 4B-8 Secaucus, NJ 07094 Tel: 201-348-7758 / Fax: 201-392-4564
Request for Short-Term Confidentiality Date: July 5, 2013 UL Japan, Inc. 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan FCC ID : ACJ-LB-DM9 Applicant : Panasonic Corporation of North America To whom it may concern: Please be advised that the following information is to be held in confidence for 160 days from the date of the Grant of Equipment Authorization and behalf of us, referring to the FCC rules 0.457 and 0.459: External Photos Internal Photos Test Setup Photos User Manual The application contains technical information, which we deem to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Sincerely, ご署名下さい。 ____________________________________ Richard Mullen Group Manager Panasonic Corporation of North America One Panasonic Way 4B-8 Secaucus, NJ 07094 Tel: 201-348-7758 / Fax: 201-392-4564
Product Photo(outside) SIDE SIDE FRONT BOTTOM REAR TOP
Radio Frequency Identification/RFID (13.56MHz) Part both sides 䛆 Module 䛇 䛆 Antenna 䛇
Radio Frequency Identification/RFID (13.56MHz) Part position Module position Decomposition Antenna position Module position Antenna position
A-005-12-C (FCC ID : ACJ-LB-DM9) Page 2 of 22 KEC Testing Division Table of Contents 1. LABORATORY INFORMATION ..................................................................................................................... 3 1.1. Laboratory Accreditation .............................................................................................................................. 3 1.2. Test Facility .................................................................................................................................................. 3 1.3. Measurement Uncertainty ............................................................................................................................. 3 2. GENERAL INFORMATION ............................................................................................................................. 4 2.1. Product Description ...................................................................................................................................... 4 3. TESTED SYSTEM .............................................................................................................................................. 5 3.1. Reference Rule and Specification ................................................................................................................. 5 3.2. Date of Test ................................................................................................................................................... 5 3.3. Deviation of Standard ................................................................................................................................... 5 3.4. Test Mode ..................................................................................................................................................... 5 3.5. Block Diagram of TEST System .................................................................................................................. 6 3.6. List of Test System ....................................................................................................................................... 7 3.7. List of Cables ................................................................................................................................................ 7 4. AC POWER LINE CONDUCTED EMISSION MEASUREMENT .............................................................. 8 4.1. Test Procedure .............................................................................................................................................. 8 4.2. Test Results ................................................................................................................................................... 9 5. Radiated Emission (The Frequency Range of 9kHz to 30MHz) .................................................................... 11 5.1. Test Procedure ............................................................................................................................................ 11 5.2. Test Results ................................................................................................................................................. 12 6. Radiated Emission (The Frequency Range of above 30MHz) ....................................................................... 13 6.1. Test Procedure ............................................................................................................................................ 13 6.2. Test Results ................................................................................................................................................. 14 7. FREQUENCY TOLERANCE OF CARRIER SIGNAL ................................................................................ 16 7.1. Test Procedure ............................................................................................................................................ 16 7.2. Test Results ................................................................................................................................................. 17 8. TEST EQUIPMENT ......................................................................................................................................... 21 APPENDIX A (20dB BANDWIDTH MEASUREMENT) .................................................................................. 22 M130709: This page (Page 2 of 22) is amended for the original test report (Report No. A-005-12-C, dated 15 March 2013). A-005-12-C (FCC ID : ACJ-LB-DM9) Page 3 of 22 KEC Testing Division 1. LABORATORY INFORMATION 1.1. Laboratory Accreditation The KEC has been accredited by the following organizations based on their criteria for testing laboratory (ISO/IEC 17025). (1) American Association for Laboratory Accreditation (A2LA) : Accreditation Number: 2070.01 (2) Japan Accreditation Board for Conformity Assessment (JAB) : Accreditation Number: RTL02810 (3) Voluntary EMC Laboratory Accreditation Center Inc. (VLAC) : Accreditation Number: VLAC-005 1.2. Test Facility All tests described in this report were performed by: Name: KEC Electronic Industry Development Center Testing Division Address: 3-2-2, Hikari-dai, Seika-cho, Soraku-gun, Kyoto 619-0237 Japan Anechoic Chamber : No.1 No.2 No.3 No.6 No.7 No.8 No.9 No.10 No.11 No.12 Shielded Room : No.1 No.7 No.8 No.9 No.10 Harmonic Current Meas. Room : 1.3. Measurement Uncertainty The result of a measurement is only an approximation or estimate of the value of a specific quantity. And thus the measurand is complete only when a statement of uncertainty is given. KEC quotes Measurement Uncertainty (U) as follows. Conducted Disturbance at M ains Port (150kHz-30M Hz)+2.6 / -2.8 dB Conducted Disturbance at M ains Port (9kHz-30M Hz)+2.9 / -3.3 dB Conducted Disturbance at Telecommunication Ports ISN method (None-Shield ty p e)+2.6 / -2.9 dB Conducted Disturbance at Telecommunication Ports ISN method (Shield ty…
Text truncated - open the document above for the full version.
A-005-12-C (FCC ID : ACJ-LB-DM9) Page 1 of 2 KEC Testing Division 1. APPENDIX Photographs of EUT System Configuration AC Power Line Conducted Emission Measurement A-005-12-C (FCC ID : ACJ-LB-DM9) Page 2 of 2 KEC Testing Division Radiated Emission (The Frequency Range of 9kHz to 30MHz) Radiated Emission (The Frequency Range of above 30MHz)
3-2-2, Hikari-dai, Seika-cho Soraku-guni · Kyoto · Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |
Digital Wireless Stereo Headphones
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterContactless Smart Card Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Car AV Control Unit for CDC
Equipment Class
DTS - Digital Transmission SystemDECT Handset
Equipment Class
PUE - Part 15 Unlicensed PCS portable Tx held to earDECT Base Unit
Equipment Class
PUB - Part 15 Unlicensed PCS Base Station