FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Panasonic Corporation of North America/
  3. ACJ96NKX-TGEA20

ACJ96NKX-TGEA20DECT 6.0 Handset

Panasonic Corporation of North America
DECT 6.0 Handset - FCC ID ACJ96NKX-TGEA20 - Panasonic Corporation of North America
Click to zoom

Application Details

Equipment Class
PUE - Part 15 Unlicensed PCS portable Tx held to ear
Date of Grant
Dec 08, 2013
Application Purpose
Original Equipment
Date of Application
Dec 08, 2013
Equipment Note
DECT 6.0 Handset
Frequency Range
1921.53600000 - 1928.44800000
Company
Panasonic Corporation of North America
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Manual Additional Digital Cordless Handset Model No. KX-TGEA20 KX-TGHA20 KX-TGEA20KX-TGHA20 Thank you for purchasing a Panasonic product. This unit is an additional handset compatible with the following series of Panasonic Digital Cordless Phone: - KX-TGE210/KX-TGE230/KX-TGE240/KX-TGE260/KX-TGE270 (KX-TGEA20) - KX-TGH260 (KX-TGHA20) (The corresponding models are subject to change without notice.) You must register this handset with your base unit before it can be used. This installation manual describes only the steps needed to register and begin using the handset. Please read the base unit’s operating instructions for further details. Please read this installation manual before using the unit and save it for future reference. For assistance, visit our Web site: http://www.panasonic.com/help for customers in the U.S.A. or Puerto Rico. Printed in Malaysia PNQX6369ZA PT1213MG0 TGEA_TGHA20(en)_1004_ver001.pdf 12013/10/04 18:56:56 Accessory information Supplied accessories Accessory item/Order numberQuantity Charger *1 1 AC adaptor/PNLV233Z1 Rechargeable batteries/HHR-4DPA2 Handset cover *2, *3 1 Belt clip (KX-TGEA20) *4 1 *1 KX-TGEA20: PNLC1050ZB KX-TGHA20: PNLC1051ZB *2 The handset cover comes attached to the handset. *3 KX-TGEA20: PNYNTGEA20BR (Black), PNYNTGEA20SR (Silver) KX-TGHA20: PNYNTGHA20BR *4 PNKE1312Z2 (Black), PNKE1312Z1 (Silver) Note: RPlease read the base unit’s operating instructions for additional/replacement accessories. – Optional headsets (KX-TGEA20): KX-TCA60, KX-TCA93, KX-TCA400, KX-TCA430 Setting up Connections/Wall mounting Connect the AC adaptor to the power outlet. Drive the screws () (not supplied) into the wall, if necessary. ( ) 27.2 mm (1 1 /16 inches) 1 2 1 2 For assistance, please visit http://www.panasonic.com/help Installation TGEA_TGHA20(en)_1004_ver001.pdf 22013/10/04 18:56:56 Note: RUse only the supplied Panasonic AC adaptor PNLV233. RThe AC adaptor must remain connected at all times. (It is normal for the adaptor to feel warm during use.) RMake sure that the wall and the fixing method are strong enough to support the weight of the unit. Battery installation/Battery charging Important: RUse the supplied rechargeable batteries. For replacement, we recommend using the Panasonic rechargeable batteries noted on page 2. RUSE ONLY rechargeable Ni-MH batteries AAA (R03) size ( 1 ). RDo NOT use Alkaline/Manganese/Ni-Cd batteries. RConfirm correct polarities ( , ). Charge for about 7 hours. RConfirm “Charging” is displayed ( 2 ). RWhen the batteries are fully charged, “Fully charged” is displayed. 1 2 RModel shown is KX-TGEA20. Note: RIf the batteries are fully charged, but the operating time seems to be shorter, clean the battery ends ( , ) and the charge contacts with a dry cloth and charge again. Registering a handset to a base unit 1Base unit: Press and hold MLOCATORN or MHANDSET LOCATORN for about 5 seconds. RDepending on the base unit, a registration tone sounds. For assistance, please visit http://www.panasonic.com/help 3 Installation TGEA_TGHA20(en)_1004_ver001.pdf 32013/10/04 18:56:56 RIf all registered handsets start ringing, press MLOCATORN or MHANDSET LOCATORN again to stop, then repeat this step. 2Handset: Place the handset on the base unit or charger, then wait until a long beep sounds and is displayed. Note: RIf an error tone sounds, or if is displayed, register the handset according to the base unit’s operating instructions. Display language 1MMENUN (right soft key) #110 2MbN: Select the desired setting. a MSAVEN a MOFFN For your safety To prevent severe injury and loss of life/property, read this section carefully before using the product to ensure proper and safe operation of your product. WARNING Power connection RCompletely insert the AC adaptor/power plug into the power outlet. Failure to do so may cause electric shock and/or excessive heat resulting in a fire. RRegularly remove any dust, etc. from the AC adaptor/power plug by pulling it from the power outlet, then wiping with a dry cloth. Accumulated dust may cause an insulation defect from moisture, etc. resulting in a fire. RUnplug the product from power outlets if it emits smoke, an abnormal smell, or makes an unusual noise. These conditions can cause fire or electric shock. Confirm that smoke has stopped emitting and contact the Panasonic Call Center at 1-800-211- PANA (1-800-211-7262). Installation RTo prevent the risk of fire or electrical shock, do not expose the product to rain or any type of moisture. RDo not place or use this product near automatically controlled devices such as automatic doors and fire alarms. Radio waves emitted from this product may cause such devices to malfunction resulting in an accident. 4 For assistance, please visit http://www.panasonic.com/help Installation TGEA_TGHA20(en)_1004_ver001.pdf 42013/10/04 18:56:56 CAUTION Installation and location RThe AC adaptor is used as the main disconnect device. Ensure that the AC outlet is installed near the product and is easily accessible. Battery RWe recommend using the supplied batteries or additional/replacement batteries noted on page 2 for replacement battery information. USE ONLY rechargeable Ni-MH batteries AAA (R03) size. RDo not mix old and new batteries. RDo not open or mutilate the batteries. Released electrolyte from the batteries is corrosive and may cause burns or injury to the eyes or skin. The electrolyte is toxic and may be harmful if swallowed. RExercise care when handling the batteries. Do not allow conductive materials such as rings, bracelets, or keys to touch the batteries, otherwise a short circuit may cause the batteries and/or the conductive material to overheat and cause burns. RCharge the batteries provided with or identified for use with this product only, in accordance with the instructions and limitations specified in this manual. ROnly use a compatible base unit (or charger) to charge the batteries. Do not tamper with the base unit (or charger). Failure to follow these instru…

Text truncated - open the document above for the full version.

Cover Letter(s)

EXHIBIT A STATEMENT OF SECURITY CODE This cordless telephone system has more than 1,000 billion combinations that are provided by the following means:  Provided with 128 bits for security codes.  When shipped from the factory, the security code is decided by the manufacture. It is memorized in a memory IC.  Base and Handset knows each other’s security code information.

Cover Letter(s)

Panasonic Corporation of North America Two Riverfront Plaza, 9 th Floor, Newark, NJ 07102-5490 Tel/Fax: 201-348-7758 / [email protected] Richard Mullen, Group Manager Product Safety and Compliance Division Power of Attorney December 5, 2013 PCTP-13-F006 Federal Communication Commission Equipment Authorization Division / Application Processing Branch 7435 Oakland Mills Road Columbia, Maryland 21046 To whom it may concern; Panasonic Corporation of North America hereby authorizes Nemko AS to act on our behalf in all matters relating to the preparation of TCB Certification application for the below described product, which are in compliance with FCC Part 15D. Any and all acts carried out by Nemko AS on our behalf shall have the same effects as acts of our own for a period of one year from the date of this letter. Type Filing: Original Application for DECT Cordless Telephone Handset, Model KX-TGEA20 1 Product Classification: Part 15 Unlicensed PCS Portable Tx Held to Ear (PUE) FCC ID Handset Unit ACJ96NKX-TGEA20 FCC Rule Part: FCC Part 15, Subpart D Frequency Range: 1921.536 ~ 1928.448 MHz Responsible Panasonic Corporation of North America Applicant & Grantee: Two Riverfront Plaza, 9 th Floor, Newark, NJ 07102-5490 Responsible Manufacturer: Panasonic System Networks Co., Ltd. Sincerely yours, Richard Mullen Richard Mullen Group Manager Panasonic Corporation of North America Product Safety and Compliance Department 1 DECT Handset under FCC ID: ACJ96NKX-TGEA20 may be marketed with DECT Bases, which will be Part 15D certified under the following FCC IDs: ACJ96NKX-TGE270, ACJ96NKX-TGE240, or ACJ96NKX-TGE230. Panasonic Corporation of North America Two Riverfront Plaza, 9 th Floor, Newark, NJ 07102-5490 Tel/Fax: 201-348-7758 / [email protected] Richard Mullen, Group Manager Product Safety and Compliance Division Request for Confidentiality December 5, 2013 PCTP-13-F006 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, Maryland 21046 To whom it may concern; Type Filing: Original Application for DECT Cordless Telephone Handset, Model KX-TGEA20 Product Classification: Part 15 Unlicensed PCS Portable Tx Held to Ear (PUE) FCC ID Handset Unit ACJ96NKX-TGEA20 FCC Rule Part: FCC Part 15, Subpart D In accordance with provisions of Sections 0.457 and 0.459 of the Commission’s Rules and Section 552(b)(4) of the Freedom of Information Act, we request permanent confidentiality for exhibits, which contain: (1) Antenna Construction; (2) Description of Electrical Circuitry; (3) Schematic Diagrams of Handset Unit and RF Unit; and (4) Block Diagram. The transmitter is not user adjustable and does not have a Tune-Up Procedure. These exhibits contain proprietary, confidential and trade secrets material, which would not be routinely made available for public inspection. In accordance with FCC Public DA 04-1705, we request forty-five day short-term confidentiality, starting from the from the issuance of equipment authorization date, for exhibits, which contain: (1) External Photographs of Handset Unit and RF Unit; (2) Internal Photographs of Handset Unit and RF Unit; (3) Test Setup Photographs; and (4) User Manual. These exhibits contain pre-market information, which could give our competitors unfair advantage should this information be released before this product is actually introduced into the common marketplace. Sincerely yours, Richard Mullen Richard Mullen Group Manager Panasonic Corporation of North America Product Safety and Compliance Department

External Photos

EXTERNAL PHOTOGRAPHS KX-TGEA20 Top View Bottom View

ID Label/Location Info

EXHIBIT B MARKINGS Portable Unit: FCC ID Label (Nameplate) The marking will be shown on the battery compartment of the portable unit.

Internal Photos

INTERNAL PHOTOGRAPHS Internal View Internal View 2 Bottom View

RF Exposure Info

The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Confidential Page 1 of 31 Report Dosimetric Assessment of the Portable Device KX-TGAE20 (FCC ID: ACJ96NKX-TGAE20) (IC: 216A-KXTGAE20) According to the FCC Requirements November 22, 2013 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Panasonic System Networks Co., Ltd. 1 - 62, 4 - chome Minoshima, Hakata, Fukuoka 812-8531 Japan The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. This version supersedes all previous versions of this report. SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Confidential Page 2 of 31 Dasy_Report_FCC_DECT_1900_Head_Body_1.0/10.07.2013/AvB Executive Summary The KX-TGAE20 is a new cordless phone (Portable Device) from Panasonic operating in the 1920 MHz frequency range. The device has an integrated antenna and work in US DECT standard. The objective of the measurements done by IMST was the dosimetric assessment of one device in a worst case setup in head and body worn configuration. The handset was set to use one specific frequency and maximum output power during the measurement. The examinations have been carried out with the dosimetric assessment system „DASY4“. The measurements were made according to the 47 CFR § 2.1093 [47CFR] for evaluating compliance of mobile and portable devices with FCC limits for human exposure (general population) to radiofrequency emissions, IEEE 1528-2003 [IEEE1528-2003] and IC RSS 102 Issue 4. Additional information and guidelines given by the following FCC documents were used:  SAR Measurement Requirements for 100 MHz to 6 GHz [KDB 865664 D01 v01r01]  Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies [KDB 447498 D01 v05r01] All measurements have been performed in accordance to the recommendations given by SPEAG. SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Confidential Page 3 of 31 Dasy_Report_FCC_DECT_1900_Head_Body_1.0/10.07.2013/AvB Compliance Statement The Panasonic KX-TGAE20 cordless phone (FCC ID: ACJ96NKX-TGAE20; IC: 216A-KXTGAE20) is in compliance with the following standards for uncontrolled exposure:  47 CFR § 2.1093 [47CFR]  IC RSS 102 Issue 4 [RSS 102],  IEEE Std. C95.1 - 1999 [C95.1-1999],  IEEE Std. C95.3 - 2002 [C95.3-2002],  IEEE 1528-2003 [IEEE 1528-2003],  The latest version of all relevant FCC OET KDB Procedures The phone was tested in addition to the head positions in the following body worn configurations:  Display towards the phantom, headset + belt clip attached, distance 0 mm  Display towards the ground, headset + belt clip attached, distance 0 mm The maximum results of SAR for the KX-TGAE20 are as follows: Band Frequency [MHz] CH Phantom Configuration Figure No. Highest Measured SAR 1g [W/kg] Highest Reported SAR 1g [W/kg] Plot No. US DECT 1924.992 2 Left Head Cheek 15 0.034 0.034 1 Body Worn Pos. 1 19 0.019 0.019 5 prepared by: ........................................ reviewed by: ..................................... Alexander Rahn André van den Bosch test engineer quality assurance engineer SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Confidential Page 4 of 31 Dasy_Report_FCC_DECT_1900_Head_Body_1.0/10.07.2013/AvB Table of Contents 1 SUBJECT OF INVESTIGATION .......................................................................................................... 5 2 THE IEEE STANDARD C95.1-1999 AND THE FCC EXPOSURE CRITERIA .................................... 5 2.1 DISTINCTION BETWEEN EXPOSED POPULATION, DURATION OF EXPOSURE AND FREQUENCIES ........... 5 2.2 DISTINCTION BETWEEN MAXIMUM PERMISSIBLE EXPOSURE AND SAR LIMITS .................................... 6 2.3 SAR LIMIT ..................................................................................................................................... 6 3 THE FCC MEASUREMENT PROCEDURE ......................................................................................... 7 3.1 GENERAL REQUIREMENTS .............................................................................................................. 7 3.2 DEVICE OPERATING NEXT TO A PERSON’S EAR ................................................................................ 7 3.2.1 PHANTOM REQUIREMENTS ......................................................................................................... 7 3.2.2 TEST POSITIONS ........................................................................................................................ 7 3.2.3 TEST TO BE PERFORMED .......................................................................................................... 10 3.2.4 MEASUREMENT VARIABILITY ..................................................................................................... 10 4 BODY-WORN CONFIGURATIONS ................................................................................................... 11 4.1 POC (PTT) POSITION ................................................................................................................... 11 4.2 PHANTOM REQUIREMENTS ............................................................................................................ 11 4.3 TEST TO BE PERFORMED .............................................................................................................. 11 5 THE MEASUREMENT SYSTEM ........................................................................................................ 12 5.1 PHANTOMS................................................................................................................................... 13 5.2 E-FIELD-PROBES ...........................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Plots Page 1 of 7 Appendix for the Report Dosimetric Assessment of the Portable Device KX-TGAE20 (FCC ID: ACJ96NKX-TGAE20) (IC: 216A-KXTGAE20) According to the FCC Requirements SAR Distribution Plots November 22, 2013 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Panasonic System Networks Co., Ltd. 1 - 62, 4 - chome Minoshima, Hakata, Fukuoka 812-8531 Japan The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. This version supersedes all previous versions of this report. SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Plots Page 2 of 7 dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo 1 SAR Distribution Plots, Head Measurement Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: TGEA20_yplm_1.da4 DUT: Panasonic; Type: KX-TGEA20; Program Name: DECT Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:24 Medium parameters used: f = 1924.99 MHz; σ = 1.4 mho/m; ε r = 40.6; ρ = 1000 kg/m 3 Phantom section: Left Section DASY4 Configuration: - Probe: ET3DV6R - SN1669; ConvF(5.05, 5.05, 5.05); Calibrated: 19.02.2013 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn631; Calibrated: 23.09.2013 - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Cheek Left/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.037 mW/g Cheek Left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.16 V/m; Power Drift = -0.152 dB Peak SAR (extrapolated) = 0.068 W/kg SAR(1 g) = 0.034 mW/g; SAR(10 g) = 0.018 mW/g Maximum value of SAR (measured) = 0.038 mW/g Fig. 1: SAR distribution for DECT US, channel 2, cheek position, left side of head, (November 19, 2013). SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Plots Page 3 of 7 dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: TGEA20_yplm_2.da4 DUT: Panasonic; Type: KX-TGEA20; Program Name: DECT Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:24 Medium parameters used: f = 1924.99 MHz; σ = 1.4 mho/m; ε r = 40.6; ρ = 1000 kg/m 3 Phantom section: Left Section DASY4 Configuration: - Probe: ET3DV6R - SN1669; ConvF(5.05, 5.05, 5.05); Calibrated: 19.02.2013 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn631; Calibrated: 23.09.2013 - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Tilted Left/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.017 mW/g Tilted Left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 3.71 V/m; Power Drift = -0.176 dB Peak SAR (extrapolated) = 0.028 W/kg SAR(1 g) = 0.016 mW/g; SAR(10 g) = 0.00943 mW/g Fig. 2: SAR distribution for DECT US, channel 2, tilted position, left side of head, (November 19, 2013). SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Plots Page 4 of 7 dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: TGEA20_yprm_1.da4 DUT: Panasonic; Type: KX-TGEA20; Program Name: DECT Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:24 Medium parameters used: f = 1924.99 MHz; σ = 1.4 mho/m; ε r = 40.6; ρ = 1000 kg/m 3 Phantom section: Right Section DASY4 Configuration: - Probe: ET3DV6R - SN1669; ConvF(4.89, 4.89, 4.89); Calibrated: 19.02.2013 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn631; Calibrated: 23.09.2013 - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Cheek Right/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.026 mW/g Cheek Right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.24 V/m; Power Drift = -0.028 dB Peak SAR (extrapolated) = 0.040 W/kg SAR(1 g) = 0.025 mW/g; SAR(10 g) = 0.014 mW/g Maximum value of SAR (measured) = 0.027 mW/g Fig. 3: SAR distribution for DECT US, channel 2, cheek position, right side of head, (November 19, 2013). SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Plots Page 5 of 7 dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: TGEA20_yprm_2.da4 DUT: Panasonic; Type: KX-TGEA20; Program Name: DECT Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:24 Medium parameters used: f = 1924.99 MHz; σ = 1.4 mho/m; ε r = 40.6; ρ = 1000 kg/m 3 Phantom section: Right Section DASY4 Configuration: - Probe: ET3DV6R - SN1669; ConvF(4.89, 4.89, 4.89); Calibrated: 19.02.2013 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn631; Calibrated: 23.09.2013 - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 Tilted Right/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 0.016 mW/g Tilted Right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 3.68 V/m; Power Drift = -0.179 dB Peak SAR (extrapolated) = 0.025 W/kg SAR(1 g) = 0.015 mW/g; SAR(10 g) = 0.00866 mW/g Fig. 4: SAR distribution for DECT US, channel 2, tilted position, right side of head, (November 19, 2013) SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGAE20_Plots Page 6 of 7 dasy_report_fcc_DECT_1900_plots_1.0.doc/110.…

Text truncated - open the document above for the full version.

RF Exposure Info

The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. SAR_Report_Nemko_60320_6130400_FCC_DECT_KX-TGEA20_CalData Appendix for the Report Dosimetric Assessment of the Portable Device KX-TGEA20 from Panasonic (FCC ID: ACJ96NKX-TGEA20) (IC: 216A-KXTGEA20) According to the FCC Requirements Calibration Data November 22, 2013 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Panasonic System Networks Co., Ltd. 1 - 62, 4 - chome Minoshima, Hakata, Fukuoka 812-8531 Japan SAR_Report_FCC_DECT_1900_1.2.doc/25.11.2011/AR The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. Cal_D1900V2_SN5d051_Sep2013_V2 Page 1 of 7 Calibration Certificate Certificate No: Cal_D1900V2_SN5d051_Sep2013_V2 Object: D1900V2 SN: 5d051 Date of Calibration: September 25, 2013 Next Calibration: September 2015 Object Condition: In Tolerance Calibration Equipment used: Test Equipment Serial Number Last calibration Calibrated by Next calibration Powermeter E4416A GB41050414 Nov 12 Rohde&Schwarz (262487-D-K-15012- 01-00-2012-11) Nov 14 Power Sensor E9301H US40010212 Nov 12 Rohde&Schwarz (262492-D-K-15012- 01-00-2012-11) Nov 14 Powermeter E4417A GB41050441 Nov 12 Rohde&Schwarz (262488-D-K-15012- 01-00-2012-11) Nov 14 Power Sensor E9301A MY41495584 Nov 12 Rohde&Schwarz (262489-D-K-15012- 01-00-2012-11) Nov 14 Network Analyzer E5071C MY46103220 Jul 13 Rohde&Schwarz (11-300285997) Jul 15 Reference Probe EX3DV4 SN 3536 Sep 12 SPEAG (EX3-3536_Sep12) Sep 13 DAE3 SN 335 Feb 13 SPEAG (DAE3-335_Feb13) Feb 14 Cal_D1900V2_SN5d051_Sep2013_V2 Page 2 of 7 Calibration is performed according the following standards: IEEE 1528-2003 "IEEE Recommended Practice for Determining the Peak Spatial - Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless Communication Devices: Measurement Technique", December 2003 IEC 62209-1 "Procedure to measure the Specific Absorption Rate (SAR) for hand - held devices used in close proximity to the ear (frequency range of 300 MHz to 3GHz)", February 2005 IEC 62209-2 "Evaluation of Human Exposure to Radio Frequency Fields from Handheld and Body-Mounted Wireless Communication Devices in the Frequency Range of 30 MHz to 6 GHz: Human models, Instrumentation, and Procedures ", Part 2: “Procedure to determine the Specific Absorption Rate (SAR) for including accessories and multiple transmitters” Edition 1.0, 2010-01 Additional Documentation: DASY 4/5 System Handbook prepared by: reviewed by: Alexander Rahn André van den Bosch test engineer quality assurance engineer 08 Cal_D1900V2_SN5d051_Sep2013_V2 Page 3 of 7 Measurement Conditions DASY Version: Dasy 4; V4.7 Phantom: SAM Phantom 1059 Distance Dipole Center – TSL: 10mm With spacer Area Scan resolution dx, dy = 10mm Zoom Scan resolution dx, dy, dz = 5mm Frequency: 1900 MHz ± 1MHz Head TSL Parameters Temperature Permittivity Conductivity Nominal Head TSL Parameters 22.0 40.00 1.40 Measured Head TSL Parameters 21.8 41.4 ± 6% 1.43 S/m ± 6% SAR Result with Head TSL Averaged over 1g SAR measured 250 mW input power 9.80 mW/g SAR normalized normalized to 1W 39.20 mW/g SAR for nominal Head TSL parameters normalized to 1W 39.01 mW/g ± 16.5 % (k=2) Averaged over 10g SAR measured 250 mW input power 4.93 mW/g SAR normalized normalized to 1W 19.72 mW/g SAR for nominal Head TSL parameters normalized to 1W 19.66 mW/g ± 16.5 % (k=2) Cal_D1900V2_SN5d051_Sep2013_V2 Page 4 of 7 Body TSL Parameters Temperature Permittivity Conductivity Nominal Body TSL Parameters 22.0 53.30 1.52 Measured Body TSL Parameters 21.7 55.00 ± 6% 1.51 S/m ± 6% SAR Result with Body TSL Averaged over 1g SAR measured 250 mW input power 9.53 mW/g SAR normalized normalized to 1W 38.12 mW/g SAR for nominal Body TSL parameters normalized to 1W 38.54 mW/g ± 16.5 % (k=2) Averaged over 10g SAR measured 250 mW input power 4.85 mW/g SAR normalized normalized to 1W 19.40 mW/g SAR for nominal Body TSL parameters normalized to 1W 19.54 mW/g ± 16.5 % (k=2) General Antenna Parameters Antenna Parameters with Head TSL Impedance, transformed to feed point 47.6 Ω + 0.21 jΩ Return Loss -32.05 dB Antenna Parameter with Body TSL Impedance, transformed to feed point 52.4 Ω – 0.83 jΩ Return Loss -32.06 dB After long term use with 100W radiated power, only a slight warming of the dipole near the feed point can be measured. The dipole is made of standard semigrid coaxial cable. The center conductor of the feeding line is directly connected to the second arm of the dipole. The antenna is therefore short-circuited for DC signals. Additional EUT Data Manufactured by: SPEAG Manufactured on: May, 2004 Cal_D1900V2_SN5d051_Sep2013_V2 Page 5 of 7 SAR Result with Head TSL Test Laboratory: IMST GmbH, DASY Blue (I); File Name: 250913_b_3536.da4 DUT: Dipole 1900 MHz SN: 5d051; Type: D1900V2; Serial: D1900V2 - SN5d051 Program Name: System Performance Check at 1900 MHz Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium parameters used: f = 1900 MHz; σ = 1.43 mho/m; ε r = 41.4; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY4 Configuration: - Probe: EX3DV4 - SN3536; ConvF(8.41, 8.41, 8.41); Calibrated: 24.09.2012 - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 18.02.2013 - Phantom: SAM Glycol 1176; Type: Speag; Serial: 1176 - Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186 d=10mm, Pin=250mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 10.8 mW/g d=10mm, Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 87.1 V/m; Power Drift = -0.014 dB Peak SAR (extrapolated) = 19.2 W/kg SAR…

Text truncated - open the document above for the full version.

Test Report

Report No. 248567-1 Template version: B Nemko Norway Nemko AS, Instituttveien 6, P.O. Box 96 Kjeller, 2007 Kjeller, Norway TEL +47 22 96 03 30 FAX +47 22 96 05 50 EMAIL [email protected] ENTERPRISE NUMBER NO974404532 nemko.com/no Test Report Product UPCS Handset Name and address of the applicant Panasonic Corporation of North America Name and address of the manufacturer Panasonic System Networks Co., Ltd. 1-62, 4-chome, Minoshima, Hakata-ku Fukuoka 812-8531, Japan Model KX-TGEA20 Rating 2.4 V DC (Secondary Batteries, 2xAAA Ni-MH cells) Trademark Panasonic Serial number / Additional information DECT 6.0 Tested according to FCC Part 15, subpart D Isochronous UPCS Device, 1920 – 1930 MHz Industry Canada RSS 213, Issue 2 2 GHz License-exempt Personal Communications Service Devices (LE-PCS) Order number 248567 Tested in period 2013.11.18 to 2013.12.05 Issue date 2013.12.05 Name and address of the testing laboratory Instituttveien 6 Kjeller, Norway FCC No: 994405 IC OATS: 2040D-1 TEL: (+47) 22 96 03 30 FAX: (+47) 22 96 05 50 Prepared by [Frode Sveinsen] Approved by [G.Suhanthakumar] This report shall not be reproduced except in full without the written approval of Nemko. Opinions and interpretations expressed within this report are not part of the current accreditation. This report was originally distributed electronically with digital signatures. For more information contact Nemko. TEST REPORT FCC part 15D Report no.: 248567-1 FCC ID: ACJ96NKX-TGEA20 Nemko Norway, Instituttveien 6, Kjeller, Norway Page 2 (48) CONTENTS 1 INFORMATION ................................................................................................................................. 3 1.1 Tested Item..........................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Ben Botros(Manager - Regulatory & Compliance)
[email protected]201-348-7760Fax: 00000

Test Firm

Nemko ASFrode Sveinsen
[email protected]47-22-96-03-35Fax: 47-22-96-05-50

Technical Specifications

#Rule PartsFrequency RangePower Output
115D1.92 GHz - 1.93 GHz82.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. SAR compliance for body-worn operating conditions is restricted to belt clips, holsters or similar accessories that have no metallic component in the assembly. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The highest reported SAR for stand-alone exposure condition is < 0.10 W/kg

Other Applications from Panasonic Corporation of North America

ACJ-EAH-A1000

Digital Wireless Stereo Headphones

Aug 19, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ACJ9TGFZVNF3G1

Contactless Smart Card Reader

Jun 16, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Car AV Control Unit for CDC - FCC ID ACJ932AM2301 - Panasonic Corporation of North America
ACJ932AM2301

Car AV Control Unit for CDC

Jan 29, 2025

Equipment Class

DTS - Digital Transmission System
ACJ96NKX-TGEA60B

DECT Handset

Aug 13, 2024

Equipment Class

PUE - Part 15 Unlicensed PCS portable Tx held to ear
ACJ96NKX-TGE630B

DECT Base Unit

Aug 12, 2024

Equipment Class

PUB - Part 15 Unlicensed PCS Base Station