KX-TGP600 KX-TPA60 Operating Instructions SIP Cordless Phone SIP Cordless Handset KX-TGP600 KX-TPA60 Model No. Model No. Thank you for purchasing this Panasonic product. Please read this manual carefully before using this product and save this manual for future use. Please use only the batteries provided and charge the batteries for about 6 hours before using the handset for the first time. For details, see "Charging the Batteries" in this manual. Note RIn this manual, the suffix of each model number is omitted unless necessary. Document Version: 2014-05 Outline T his manual describes information about the installation and operation of KX-TGP600/KX-TPA60. Related Documentation RQuick Start Guide Describes basic information about the installation and safety precautions to prevent personal injury and/or damage to property. RAdministrator Guide Describes detailed information on the configuration and management of this unit. Manuals and supporting information are provided on the Panasonic Web site at: http://panasonic.net/pcc/support/sipphone Note RThe contents and design of the software are subject to change without notice. For Future Reference Record the information in the space below for future reference. Note RThe serial number of this product may be found on the labels affixed to the following places: – base unit: the back of the unit. – handset: the inside of the battery compartment on the back of the handset. – charger: the bottom of the charger. You should note the serial numbers of these units in the space provided and retain this manual as a permanent record of your purchase to aid in identification in the event of theft. MODEL NO. SERIAL NO. DATE OF PURCHASE NAME OF DEALER DEALER’S ADDRESS DEALER’S TEL. NO. 2 Introduction Important Information Data Security ......................................................4 Additional Information .........................................5 For Best Performance .........................................9 Battery Information ...........................................10 Before Operating the Telephone Accessory Information ......................................12 Location of Controls ..........................................14 Handset Functions ............................................16 Soft Keys ..........................................................17 Other Icons .......................................................17 Feature Operations Making Calls .....................................................18 Receiving Calls .................................................18 During a Conversation ......................................18 Useful Features ................................................18 Customizing the Telephone Using the Handset Phonebook .........................19 Entering Characters ..........................................19 Changing Handset Settings ..............................19 Installation and Setup Installation and Setup .......................................20 Appendix Appendix ...........................................................23 Troubleshooting ................................................23 Error Messages ................................................23 Index Index..................................................................24 3 Table of Contents Data Security RT his telephone communicates using digital signals that are difficult to intercept. However, it is possible that the signals could be intercepted by a third party. RTo avoid unauthorized access to this product: – Keep the password (e.g., PIN for registration) secret. – Change the default password. – Set a password that is random and cannot be easily guessed. – Change the password regularly. RThis product can store your private/confidential information. To protect your privacy/confidentiality, we recommend that you erase the information such as the phonebook or call log from the memory before you dispose of, transfer or return the product, or have the product repaired. RSet the password when you register the handset to the base unit. RIt is recommended that you lock the phonebook to prevent stored information from being leaked when you carry the handset or if the handset is lost. 4 Important Information Additional Information Information for Users on Collection and Disposal of Old Equipment and used Batteries These symbols on the products, packaging, and/or accompanying documents mean t hat used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. Information on Disposal in other Countries outside the European Union T hese symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): T his symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. The following declaration is applicable to KX-TGP600/KX-TPA60 o…
Text truncated - open the document above for the full version.
KX-TGP600 KX-TPA60 Manuel d’utilisation KX-TGP600 KX-TPA60 Nº de modèle Nº de modèle Téléphone sans fil SIP Combiné sans fil SIP Merci d’avoir acheté ce produit Panasonic. Veuillez lire attentivement ce manuel avant d’utiliser ce produit et gardez-le pour toute consultation ultérieure. N’utilisez que les piles fournies et rechargez-les pendant environ 6 heures avant la première utilisation du combiné. Pour les détails, consultez "Recharge des piles" dans ce manuel. Remarque RDans le présent manuel, le suffixe des numéros de modèle est omis, sauf s’il est nécessaire de l’indiquer. Version du document : 2014-05 Aperçu Ce manuel donne des renseignements sur l’installation et le fonctionnement du KX-TGP600/KX-TPA60. Documents connexes RGuide de démarrage rapide Donne des renseignements de base sur l’installation et les mesures de sécurité pour empêcher les blessures et/ ou les dommages matériels. RGuide de l’administrateur Donne des renseignements sur la configuration et la gestion de cet appareil. Les manuels et les renseignements complémentaires sont disponibles sur le site Web de Panasonic à l’adresse : http://panasonic.net/pcc/support/sipphone Remarque RLe contenu et la configuration du logiciel sont indiqués sous réserve de modifications sans préavis. Pour consultation future Inscrivez les renseignements dans l’espace ci-dessous aux fins de consultation future. Remarque RLe numéro de série de ce produit est indiqué sur les étiquettes collées aux emplacements suivants : – unité de base : à l’arrière de l’appareil. – combiné : à l’intérieur du compartiment des piles à l’arrière du combiné. – chargeur : sur le dessous du chargeur. Vous devriez noter les numéros de série de ces appareils dans l’espace réservé et conserver le présent manuel à titre de preuve d’achat permanente aux fins d’identification en cas de vol. Nº DE MODÈLE NUMÉRO DE SÉRIE DATE D’ACHAT NOM DU DÉTAILLANT ADRESSE DU DÉTAILLANT NUMÉRO DE TÉLÉPHONE DU DÉTAILLANT 2 Introduction Renseignements importants Sécurité des données ..................................................4 Renseignements supplémentaires ..............................5 Pour un rendement optimal .......................................10 Renseignements sur les piles ....................................11 Avant d’utiliser le téléphone Renseignements sur les accessoires ........................13 Emplacement des commandes .................................15 Fonctions du combiné ...............................................17 Touches de sélection .................................................18 Autres icônes .............................................................18 Fonctionnalités Pour faire des appels .................................................19 Pour recevoir des appels ...........................................19 Pendant une conversation .........................................19 Fonctions pratiques ...................................................19 Personnalisation du téléphone Utilisation du répertoire téléphonique du combiné ....20 Saisie de caractères ..................................................20 Modification des paramètres du combiné ..................20 Installation et configuration Installation et configuration ........................................21 Annexe Annexe ......................................................................24 Dépannage ................................................................24 Messages d’erreur .....................................................24 Index Index..................................................................25 3 Table des matières Sécurité des données RCe téléphone communique au moyen de signaux numériques difficiles à intercepter. Il est cependant possible que ceux-ci soient interceptés par un tiers. RPour empêcher l’accès non autorisé à l’appareil : – Garder le mot de passe (ex. le NIP pour l’enregistrement) secret. – Modifier le mot de passe par défaut. – Choisir un mot de passe aléatoire et difficile à deviner. – Modifier le mot de passe régulièrement. RCet appareil peut mettre en mémoire des renseignements privés/confidentiels. Pour protéger votre vie privée/ confidentialité, nous vous recommandons d’effacer les renseignements tels que le répertoire téléphonique ou journal des appels de la mémoire avant de jeter, transférer ou retourner l’appareil, ou avant de le faire réparer. RRégler le mot de passe lors de l’enregistrement du combiné sur l’unité de base. RIl est recommandé de verrouiller le répertoire téléphonique afin d’empêcher une fuite des renseignements sauvegardés lors du transport ou en cas de perte du combiné. 4 Renseignements importants Renseignements supplémentaires Avis aux utilisateurs concernant la collecte et la mise au rebut des piles et des appareils électriques et électroniques usagés Apposé sur le produit lui-même, sur son emballage, ou figurant dans la documentation qui l’ac- compagne, ce symbole indique que les piles et appareils électriques et électroniques usagés doi- vent être séparés des ordures ménagères. Afin de permettre le traitement, la valorisation et le recyclage adéquats des piles et des appareils usagés, veuillez les porter à l’un des points de collecte prévus, conformément à la législation na- tionale en vigueur ainsi qu’aux directives 2002/96/CE et 2006/66/CE. En mettant les piles et appareils usagés au rebut conformément à la réglementation en vigueur, vous contribuez à prévenir le gaspillage de ressources précieuses ainsi qu’à protéger la santé humaine et l’environnement contre les effets potentiellement nocifs d’une manipulation inappro- priée des déchets. Pour de plus amples renseignements sur la collecte et le recyclage des piles et appareils usa- gés, veuillez vous renseigner auprès de votre mairie, du service municipal d’enlèvement des dé- chets ou du point de vente où vous avez acheté les articles concernés. Le non-respect de la réglementation relative à la mise au rebut des déchets est passible d’amen- des. Pour les …
Text truncated - open the document above for the full version.
EXHIBIT A STATEMENT OF SECURITY CODE This cordless telephone system has more than 1,000 billion combinations that are provided by the following means: ∑ Provided with 128 bits for security codes. ∑ When shipped from the factory, the security code is decided by the manufacture. It is memorized in a memory IC. ∑ Base and Handset knows each other’s security code information.
FCC Part 15D – Compliance Information Nemko AS, Instituttveien 6, 2007 Kjeller, Norway kx-tgp600_tpa60 fcc part 15d declarations Tel: +47 22 96 03 30 Fax: +47 22 96 05 50 Page 1 (5) rev.2.3 17-Jul-2013 Email: [email protected] EUT AND PRODUCT INFORMATION Type of Equipment UPCS (DECT 6.0) Applicant Name Panasonic System Networks Co., Ltd. Address 1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka, 812-8531, Japan Contact Michihito Miyazaki Telephone +81-50-3380-2671 Email [email protected] Grantee Code ACJ IC Company Number 216A Brand Name Panasonic Model Number KX-TGP600 (Base), KX-TPA60 (Handset) FP PP Repeater EUT Type/System FCC ID ACJ96NKX-TGP600 ACJ96NKX-TPA60 Industry Canada ID 216A-KXTGP600 216A-KXTPA60 Model name KX-TGP600 KX-TPA60 HW Version PNLB2350ZAxx PNLB2348ZAxx SW Version SW00.010 SW0.50 Maximum Antenna Gain 2dBi 1.5dBi Can the EUT be Initiating Device YES YES YES Does the EUT transmit signaling channels YES YES YES Max number of slots in use simultaneously 10 slot 1 slot Test standard: FCC part 15D RSS-213, Issue 2 / RSS-GEN, Issue 3 Frequency Band 1921.536 – 1928.448 MHz Number of RF Channels 5 Frame Period 10 ms Max. Burst length 723us / duplex channel Min. Burst Length 106us / signaling channel Minimum Number of System Channels 60 (12 duplex channels per RF carrier) Supported DECT Slot Types Full Slot Long Slot Operating Mode Simplex Duplex FCC Part 15D – Compliance Information Nemko AS, Instituttveien 6, 2007 Kjeller, Norway kx-tgp600_tpa60 fcc part 15d declarations Tel: +47 22 96 03 30 Fax: +47 22 96 05 50 Page 2 (5) rev.2.3 17-Jul-2013 Email: [email protected] ANTENNAS Base (FP) Antenna Type Internal External 1 λ/4 monopole Antenna 2 λ/4 monopole Antenna 3 4 Does RX and TX use the same antenna(s)? Yes No Handset (PP) Antenna Type Internal External 1 λ/4 PIFAntenna 2 Does RX and TX use the same antenna(s)? Yes No ANTENNA DIVERSITY Antenna Diversity Supported TX RX Base (FP) 1 2 3 4 Handset (PP) 1 2 VOLTAGE AND TEMPERATURE RANGES VOLTAGES FP PP Repeater Nominal Voltage 120V AC DC 2.6V Cut-Off Voltage (if applicable) 2.35V POWER SOURCE Type Manufacturer Base or Repeater PQLV219 (AC Adaptor for Base) Panasonic Handset (PP) (charger) PNLV226 (AC Adaptor for charger) Panasonic Data Connections PSTN Others (please specify) .... .LAN(RJ-45) FCC Part 15D – Compliance Information Nemko AS, Instituttveien 6, 2007 Kjeller, Norway kx-tgp600_tpa60 fcc part 15d declarations Tel: +47 22 96 03 30 Fax: +47 22 96 05 50 Page 3 (5) rev.2.3 17-Jul-2013 Email: [email protected] ANCILLARY EQUIPMENT Description Charger cradle Type PNLC1061ZA (Charger for KX-TPA60) Manufacturer Panasonic HOST DEVICE Description Type Manufacturer ADDITIONAL INFORMATION FCC Part 15D – Compliance Information Nemko AS, Instituttveien 6, 2007 Kjeller, Norway kx-tgp600_tpa60 fcc part 15d declarations Tel: +47 22 96 03 30 Fax: +47 22 96 05 50 Page 4 (5) rev.2.3 17-Jul-2013 Email: [email protected] MANUFACTURERS DECLARATIONS FCC part 15.323 (c)(5) The applicant declares that the system in this application has more than 40 duplex system access channels defined, and that the system is operating in Least Interfered Channel (LIC) mode in accordance with this section. Applicant Agrees Yes No FCC part 15.323 (c)(5) No device or group of co-operating devices located within 1m of each other shall during any frame period occupy more than 6 MHz of aggregate bandwidth, or alternatively, more than one third of the time and spectrum windows defined by the system. Applicant Agrees Yes No FCC part 15.323 (c)(10) The applicant hereby declares that the system in this application does use the criteria of (c)(10) of this section. Applicant Agrees Yes No FCC part 15.323 (c)(11) The applicant hereby declares that system in this application does not use the criteria of (c)(11) of this section. Applicant Agrees Yes No FCC part 15.323 (c)(12) The provisions of (c)(10) or (c)(11) of this section shall not be used to extend the range of spectrum occupied over space or time for the purpose of denying fair access to spectrum to other devices. Applicant Agrees Yes No FCC part 15.307 (b) The Applicant is a participating member of UTAM, Inc. and will provide an affidavit from UTAM, Inc. certifying this. Confirmed By Applicant Yes No ADDITIONAL REMARKS: > DECLARED BY: May 13, 2014 Date Michihito Miyazaki Name (print) Signature FCC Part 15D – Compliance Information Nemko AS, Instituttveien 6, 2007 Kjeller, Norway kx-tgp600_tpa60 fcc part 15d declarations Tel: +47 22 96 03 30 Fax: +47 22 96 05 50 Page 5 (5) rev.2.3 17-Jul-2013 Email: [email protected] About this document This document specifies the information that is needed to select the correct testcases and test procedures for testing to FCC Part 15D. The form must be completed by the applicant and submitted to Nemko before testing is started. Preparation of Equipment for Testing Note (a): Number of samples for testing The following samples are needed for FCC 15D testing: RF Conducted Tests: One sample with a 50 ohm antenna connector (preferably SMA Female). Only one antenna connector is needed for these tests even if the equipment has more than one antenna. Monitoring Tests: One sample with 50 ohm antenna connectors fitted to all antennas (preferably SMA female). Additionally we need a companion device that will work together with the EUT, the companion device must also have antenna connectors on all antennas. Radiated Tests: One sample with integral antennas. This sample will be used to measure Antenna Gain, Part 15B and Power-Line Conducted tests. Note (b): Monitoring Tests Monitoring tests are performed by establishing a connection from the handset (or the initiating device) to the base station (or the responding device). Most tests are performed by establishing connections from the initiating device to the responding device and observing which channel and/or timeslot is used. For monitoring tests we need a EUT and a Companion device that both have antenna conn…
Text truncated - open the document above for the full version.
Panasonic Corporation of North America Two Riverfront Plaza, 9 th Floor, Newark, NJ 07102-5490 Tel/Fax: 201-348-7758 / [email protected] Richard Mullen, Group Manager Product Safety and Compliance Division Authority to Act as Agent July 16, 2014 PCNF-14-F046 Nemko Canada Inc. 303 River Road Ottawa, Ontario, Canada K1V 1H2 Re: Original FCC Certification Application for DECT 6.0 Cordless Telephone Handset Station for SIP Server or PBX under FCC ID: ACJ96NKX-TPA60 Attn: Director of Certification On our behalf, I appoint Nemko A/S, Instituttveien 6, N-2007 Kjeller, Norway, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Nemko Canada Inc., still resides with Panasonic Corporation of North America. Any and all acts carried out by Nemko on our behalf shall have the same effects as acts of our own for a period of one year from the date of this letter. Please advise the undersigned if you have any questions or comments. Thank you for your attention and cooperation in this matter. Sincerely yours, Richard Mullen Richard Mullen Group Manager Panasonic Corporation of North America Product Safety and Compliance Division Panasonic Corporation of North America Two Riverfront Plaza, 9 th Floor, Newark, NJ 07102-5490 Tel/Fax: 201-348-7758 / [email protected] Richard Mullen, Group Manager Product Safety and Compliance Division Request for Confidentiality July 16, 2014 PCNF-14-F046 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Original FCC Certification Application for DECT 6.0 Cordless Telephone Handset Station for SIP Server or PBX under FCC ID: ACJ96NKX-TPA60 To whom it may concern; In accordance with provisions of Sections 0.457 and 0.459 of the Commission’s Rules and Section 552(b)(4) of the Freedom of Information Act, we request permanent confidentiality for the below exhibits. The transmitter is not user adjustable and does not have a provided Tune-Up Procedure. The below exhibits contain proprietary, confidential and trade secrets material, which would not be routinely made available for public inspection. • Schematic Diagrams of Handset Unit and RF Unit • Block Diagrams of Handset Unit and RF Unit • Description of Electrical Circuitry • Antenna Construction In accordance with FCC Public DA 04-1705, we request forty-five day short-term confidentiality, starting from the issuance of equipment authorization date, for the below exhibits. These exhibits contain pre-market information, which could give our competitors unfair advantage should this information be released before this product is actually introduced into the common marketplace. • External Photographs of Handset Unit and RF Unit • Internal Photographs of Handset Unit and RF Unit • Test Setup Photographs • User Manual Please advise the undersigned if you have any questions or comments. Thank you for your attention and cooperation in this matter. Sincerely yours, Richard Mullen Richard Mullen Group Manager Panasonic Corporation of North America Product Safety and Compliance Division
EXHIBIT D-1 EXTERNAL PHOTOGRAPHS Page 1 of 2 EXHIBIT D-1 EXTERNAL PHOTOGRAPHS Page 2 of 2
EXHIBIT B MARKINGS
EXHIBIT D-2 INTERNAL PHOTOGRAPHS Page 1 of 2 EXHIBIT D-2 EXTERNAL PHOTOGRAPHS Page 2 of 2
Partslist Partsnumber Vender Partsnumber Ref OR1 OR2 RE1 PNLB2348ZA-GW-S1 PCB RE2 B1ABGE000011 BC817K-40 Q204 B1ABGE000014 RE2 B1ADCF000040 2SA1774TLQR Q200 DSA900100L B1ADCF000196 RE2 B1ADCF000040 2SA1774TLQR Q205 DSA900100L B1ADCF000196 RE1 B3AFB0000570 QSMW-C13P LED501 RE1 B3AFB0000570 QSMW-C13P LED502 RE1 B3AFB0000570 QSMW-C13P LED503 RE1 B3AFB0000570 QSMW-C13P LED504 RE1 B3AFB0000570 QSMW-C13P LED505 RE1 B3AFB0000570 QSMW-C13P LED506 RE2 C0DBZYY00357 BU90030G-TR IC104 RE2 C2HBCY000148 DCX81ACPCFAE4FNC-P IC1 VJ1 C3FBPY000283 W25Q64FVSSIG-TRAY IC100 RE1 D4FB1R100026 FSMD110-16-R P1 RE2 DB2J20100L DB2J20100L D200 RE2 DSC9001S0L DSC9001S0L Q201 RE2 DSC9001S0L DSC9001S0L Q501 RE2 ECUE0J105KBQ ECUE0J105KBQ C2 RE2 ECUE0J105KBQ ECUE0J105KBQ C6 RE2 ECUE0J105KBQ ECUE0J105KBQ C11 RE1 ECUE0J105KBQ ECUE0J105KBQ C13 RE2 ECUE0J105KBQ ECUE0J105KBQ C15 RE1 ECUE0J105KBQ ECUE0J105KBQ C18 RE1 ECUE0J105KBQ ECUE0J105KBQ C19 RE2 ECUE0J105KBQ ECUE0J105KBQ C21 RE2 ECUE1A104KBQ ECUE1A104KBQ C8 RE1 ECUE1A104KBQ ECUE1A104KBQ C12 RE2 ECUE1A104KBQ ECUE1A104KBQ C20 RE2 ECUE1A104KBQ ECUE1A104KBQ C22 RE2 ECUE1A104KBQ ECUE1A104KBQ C23 RE2 ECUE1A104KBQ ECUE1A104KBQ C24 RE2 ECUE1A104KBQ ECUE1A104KBQ C25 RE2 ECUE1A104KBQ ECUE1A104KBQ C29 RE2 ECUE1A104KBQ ECUE1A104KBQ C30 RE2 ECUE1A104KBQ ECUE1A104KBQ C100 RE2 ECUE1A104KBQ ECUE1A104KBQ C301 RE2 ECUE1A104KBQ ECUE1A104KBQ C302 RE1 ECUE1A104KBQ ECUE1A104KBQ C502 RE2 ECUE1H100DCQ ECUE1H100DCQ C56 RE2 ECUE1H100DCQ ECUE1H100DCQ C68 RE2 ECUE1H100DCQ ECUE1H100DCQ C512 RE2 ECUE1H100DCQ ECUE1H100DCQ L54 RE2 ECUE1H102KBQ ECUE1H102KBQ C205 RE2 ECUE1H102KBQ ECUE1H102KBQ C316 RE2 ECUE1H102KBQ ECUE1H102KBQ C321 RE2 ECUE1H102KBQ ECUE1H102KBQ C322 RE2 ECUE1H151JCQ ECUE1H151JCQ C331 RE2 ECUE1H1R5CCQ ECUE1H1R5CCQ C71 RE2 ECUE1H1R5CCQ ECUE1H1R5CCQ C74 RE2 ECUE1H2R0CCQ ECUE1H2R0CCQ C65 RE2 ECUE1H2R0CCQ ECUE1H2R0CCQ R52 RE1 ECUE1H330JCQ ECUE1H330JCQ C27 RE2 ECUE1H471KBQ ECUE1H471KBQ C320 RE2 ECUE1H5R0CCQ ECUE1H5R0CCQ C64 RE2 ECUV0J225KBV ECUV0J225KBV C3 RE2 ECUV0J225KBV ECUV0J225KBV C4 RE2 ECUV1A105KBV ECUV1A105KBV C103 RE1 ECUV1A225KBV ECUV1A225KBV C14 RE2 ECUV1C104KBV ECUV1C104KBV C212 RE2 ECUV1C393KBV ECUV1C393KBV C305 RE2 ECUV1C393KBV ECUV1C393KBV C325 RE2 EEE0JA221WP EEE0JA221WP C204 RE2 ERJ6RSJR10V ERJ6RSJR10V R201 RE2 EXB24V332JX EXB24V332JX RA300 D1H43322A008 RE2 EZAEG2A50AX EZAEG2A50AX D51 RE2 F1G1H1R8A765 UMK105CH1R8BV-F C57 RE2 F1G1H1R8A765 UMK105CH1R8BV-F C58 RE2 F1G1H1R8A765 UMK105CH1R8BV-F C59 RE2 F1G1HR20A801 GRM1554C1HR20WA01D C66 RE2 F1G1HR50A765 UMK105CH0R5BV-F L53 RE2 F1G1HR80A801 GRM1554C1HR80WA01D C67 RE2 F1H0J1060003 JMK107BJ106MA-T C1 F1H0J1060006 RE2 F1H0J1060003 JMK107BJ106MA-T C5 F1H0J1060006 RE2 F1H0J1060003 JMK107BJ106MA-T C9 F1H0J1060006 RE2 F1H0J1060003 JMK107BJ106MA-T C26 F1H0J1060006 RE2 F1H0J1060003 JMK107BJ106MA-T C31 F1H0J1060006 RE2 F1H0J1060003 JMK107BJ106MA-T C101 RE2 F1H0J1060003 JMK107BJ106MA-T C315 F1H0J1060006 RE2 F1H0J2260001 GRM188B30J226MEA0D C10 F1H0J226A062 RE2 F1H0J2260001 GRM188B30J226MEA0D C37 F1H0J226A062 RE2 F1H0J2260001 GRM188B30J226MEA0D C38 F1H0J226A062 RE2 F1H0J2260001 GRM188B30J226MEA0D C105 F1H0J226A062 RE2 F1J0J476A013 JMK212BJ476MG-T C317 F1J0J476A068 RE2 G1C220MA0320 BRL2012T220M L1 RE2 G1C2N7Z00007 HK10052N7S-T C69 RE2 G1C3N3Z00005 HK10053N3S-T C73 RE2 G1C4N7Z00004 HK10054N7S-T C70 RE2 G1C4N7Z00004 HK10054N7S-T L55 RE2 G1C8N2J00004 HK10058N2J-T L58 RE2 G1CR15JA0097 HK1005R15J-T L4 RE2 H0J138500015 DSX321G-13.824M-13824BA0A X1 RE2 J0JCC0000276 BLM15BD102SN1D L302 RE2 J0JCC0000286 BLM15AG102SN1D L303 RE2 J0JCC0000287 BLM15AG221SN1D L301 RE2 J0JCC0000407 BK1005HW601-T R316 RE2 J0JDC0000103 BK1005HS241-T L3 RE1 J0JYC0000102 BLM15HB121SN1D L501 RE2 K1KA03AA0263 BM03B-SRSS-TBT(LF)(SN) CN100 RE1 K1MY11BA0277 IMSA-9681S-11Y901 CN3 RE2 K2HD103D0001 02-828R0-33BKA CN301 K2HD1YYE0002 RE2 K5H252Y00002 0603FT2.5APCC F201 AP1 L0CBAY000097 BOM6013EP-G423-C1033 MIC RE1 LNJ826W83RA LNJ826W83RA LED530 RE1 PNERJ2GE0R00X PNERJ2GE0R00X L2 RE2 PNERJ2GE0R00X PNERJ2GE0R00X L21 RE2 PNERJ2GE0R00X PNERJ2GE0R00X L22 RE2 PNERJ2GE0R00X PNERJ2GE0R00X L52 RE2 PNERJ2GE0R00X PNERJ2GE0R00X R310 RE2 PNERJ2GE0R00X PNERJ2GE0R00X R311 RE2 PNERJ2GE0R00X PNERJ2GE0R00X R314 RE2 PNERJ2GE0R00X PNERJ2GE0R00X R317 RE1 PNERJ2GE0R00X PNERJ2GE0R00X R507 RE2 PNERJ2GEJ100X PNERJ2GEJ100X R6 RE1 PNERJ2GEJ101X PNERJ2GEJ101X R520 RE2 PNERJ2GEJ102X PNERJ2GEJ102X R306 RE2 PNERJ2GEJ103X PNERJ2GEJ103X R109 RE2 PNERJ2GEJ103X PNERJ2GEJ103X R208 RE1 PNERJ2GEJ103X PNERJ2GEJ103X R518 RE2 PNERJ2GEJ104X PNERJ2GEJ104X R7 RE2 PNERJ2GEJ104X PNERJ2GEJ104X R8 RE2 PNERJ2GEJ104X PNERJ2GEJ104X R9 RE2 PNERJ2GEJ104X PNERJ2GEJ104X R210 RE2 PNERJ2GEJ104X PNERJ2GEJ104X R307 RE2 PNERJ2GEJ104X PNERJ2GEJ104X R308 RE2 PNERJ2GEJ104X PNERJ2GEJ104X R309 RE2 PNERJ2GEJ105X PNERJ2GEJ105X R14 RE2 PNERJ2GEJ122X PNERJ2GEJ122X R500 RE2 PNERJ2GEJ122X PNERJ2GEJ122X R501 RE2 PNERJ2GEJ122X PNERJ2GEJ122X R502 RE2 PNERJ2GEJ122X PNERJ2GEJ122X R503 RE2 PNERJ2GEJ122X PNERJ2GEJ122X R504 RE2 PNERJ2GEJ122X PNERJ2GEJ122X R505 RE2 PNERJ2GEJ152X PNERJ2GEJ152X R506 RE2 PNERJ2GEJ222X PNERJ2GEJ222X R303 RE2 PNERJ2GEJ222X PNERJ2GEJ222X R304 RE2 PNERJ2GEJ222X PNERJ2GEJ222X R305 RE2 PNERJ2GEJ303X PNERJ2GEJ303X R209 RE2 PNERJ2GEJ303X PNERJ2GEJ303X R213 RE2 PNERJ2GEJ330X PNERJ2GEJ330X R107 RE2 PNERJ2GEJ332X PNERJ2GEJ332X R300 RE2 PNERJ2GEJ332X PNERJ2GEJ332X R302 RE2 PNERJ2GEJ334X PNERJ2GEJ334X R120 RE2 PNERJ2GEJ391X PNERJ2GEJ391X R301 RE1 PNERJ2GEJ471X PNERJ2GEJ471X R515 RE2 PNERJ2GEJ472X PNERJ2GEJ472X R110 RE2 PNERJ2GEJ473X PNERJ2GEJ473X R205 RE2 PNERJ2GEJ510X PNERJ2GEJ510X R50 RE2 PNERJ2GEJ680X PNERJ2GEJ680X R104 RE2 PNERJ2GEJ680X PNERJ2GEJ680X R105 RE2 PNERJ2GEJ680X PNERJ2GEJ680X R106 RE2 PNERJ3GEYJ680V PNERJ3GEYJ680V R108 RE2 PNERJ8GEYJ3R3V PNERJ8GEYJ3R3V R207 RE2 PNMC1032ZA/Z1 PNMC1032ZA/Z1 RF_Shild RE2 PQCUV0J106KB PQCUV0J106KB C102
SAR_Report_Nemko_60320_6140249_FCC_DECT_KX-TPA60_CalData The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-00. Appendix for the Report Dosimetric Assessment of the Portable Device KX-TPA60 from Panasonic (FCC ID: ACJ96NKX-TPA60) (IC: 216A-KXTPA60) According to the FCC Requirements Calibration Data July 11, 2014 IMST GmbH Carl-Friedrich-Gauß-Str. 2 - 4 D-47475 Kamp-Lintfort Customer Panasonic System Networks Co., Ltd. 1 - 62, 4 - chome Minoshima, Hakata, Fukuoka 812-8531 Japan The Testcenter facility ‘Dosimetric Test Lab’ within IMST GmbH is accredited by the German National ‘Deutsche Akkreditierungsstelle GmbH (DAkkS)’ for testing according to the scope as listed in the accreditation certificate: D-PL-12139-01-01. Cal_D1900V2_SN5d051_Sep2013_V2 Page 1 of 7 Calibration Certificate Certificate No: Cal_D1900V2_SN5d051_Sep2013_V2 Object: D1900V2 SN: 5d051 Date of Calibration: September 25, 2013 Next Calibration: September 2015 Object Condition: In Tolerance Calibration Equipment used: Test Equipment Serial Number Last calibration Calibrated by Next calibration Powermeter E4416A GB41050414 Nov 12 Rohde&Schwarz (262487-D-K-15012- 01-00-2012-11) Nov 14 Power Sensor E9301H US40010212 Nov 12 Rohde&Schwarz (262492-D-K-15012- 01-00-2012-11) Nov 14 Powermeter E4417A GB41050441 Nov 12 Rohde&Schwarz (262488-D-K-15012- 01-00-2012-11) Nov 14 Power Sensor E9301A MY41495584 Nov 12 Rohde&Schwarz (262489-D-K-15012- 01-00-2012-11) Nov 14 Network Analyzer E5071C MY46103220 Jul 13 Rohde&Schwarz (11-300285997) Jul 15 Reference Probe EX3DV4 SN 3536 Sep 12 SPEAG (EX3-3536_Sep12) Sep 13 DAE3 SN 335 Feb 13 SPEAG (DAE3-335_Feb13) Feb 14 Cal_D1900V2_SN5d051_Sep2013_V2 Page 2 of 7 Calibration is performed according the following standards: I…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15D | 1.92 GHz - 1.93 GHz | 55.00 mW |
Digital Wireless Stereo Headphones
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterContactless Smart Card Reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Car AV Control Unit for CDC
Equipment Class
DTS - Digital Transmission SystemDECT Handset
Equipment Class
PUE - Part 15 Unlicensed PCS portable Tx held to earDECT Base Unit
Equipment Class
PUB - Part 15 Unlicensed PCS Base Station