Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarant ee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Caution THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. IMPORTANT NOTE : FCC RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.5 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IC Information to User This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement. HVIN(Hardware Version Id Number): ANDANTE PMN(Product Marketing Name): Digital Pen IC: 23775-ANDANTE with pencap : approximately 30days / with pencap : approximately 10 days USB TYPE-C connection - 2hours to full charge This device complies with part 15 of the FCC Rules. Operation i s subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may caus e undesired operation.
FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarant ee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. Caution THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. IMPORTANT NOTE : FCC RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.5 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IC Information to User This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement. HVIN(Hardware Version Id Number): ANDANTE PMN(Product Marketing Name): Digital Pen IC: 23775-ANDANTE with pencap : approximately 30days / with pencap : approximately 10 days USB TYPE-C connection - 2hours to full charge This device complies with part 15 of the FCC Rules. Operation i s subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may caus e undesired operation.
Uspace2 #B-703, 670 Daewangpangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea Tel No : +82-31-606-6337 Rev 11/20/07 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of (FCC ID : ADM-ANDANTE ) Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block diagram Block diagram(ADM-ANDANTE).pdf Parts List Part List(ADM-ANDANTE).pdf Schematics Schematics_PCB Layout Schematics(ADM-ANDANTE).pdf Schematics_PCB Layout(ADM-ANDANTE) Operational description Operational description_Antenna specification Operational description(ADM-ANDANTE).pdf Operational description_Antenna specification (ADM- ANDANTE).pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Signature: Contact name : ChulMin, In Company position: Principal Research Enginner Company name: Anoto Korea Corp.
Uspace2 #B-703, 670 Daewangpangyo-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, Korea Tel No : +82-31-606-6337 Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date:Dec 31,2019 SUBJECT: FCC Application for (FCC ID : ADM-ANDANTE) To Whom It May Concern: We, the undersigned, hereby authorize Young-taek, Lee at CTK on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by CTK on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Signature: Contact name :ChulMin,In Company position: PrincipalResearchEnginner Company name: AnotoKoreaCorp.
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com EUT External Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Label Photographs 38 mm 8 mm
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com EUT Internal Photographs CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Battery Antenna
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 1 of 3 RF EXPOSURE EVALUATION Applicant Anoto Korea Corp. Applicant Address Uspace2 #B-703, 670, Daewangpangyo-ro, Seongnam-si, Republic of South Korea (Zip : 13494) Product Description Digital Pen FCC ID ADM-ANDANTE IC 23775-ANDANTE RF power Bluetooth : -2.30 dBm Peak Conducted Bluetooth LE : -4.77 dBm Peak Conducted Antenna type Chip Antenna Antenna Gain 2.1 dBi(Peak) Frequency Range 2 402 MHz – 2 480 MHz Number of channels Bluetooth : 79 Bluetooth LE : 40 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 2 of 3 ** RF Exposure Evaluation** Limits SAR Test Exclusion Thresholds for 100 MHz - 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table, The equation and threshold in Note 1 must be applied to determine SAR test exclusion. Note 1: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by : CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Page 3 of 3 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]* [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where - f(GHz) is the RF channel transmit frequency in GHz - Power and distance are rounded to the nearest mW and mm before calculation - The result is rounded to one decimal place for comparison - 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1f) is applied to determine SAR test exclusion. Output Power: Mode Frequency (MHz) Maximum output power to antenna (mW) SAR Test Exclusion Threshold (mW) Bluetooth 2 402 0.955 10 Bluetooth LE 2 402 0.541 10 Per FCC KDB 447498 D01v06, the SAR exclusion threshold for distances ≤50mm is defined by the following equation : [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]* [√f(GHz)] ≤ 3.0 Base on the maximum conducted power of the antenna to use separation distance, SAR was not required; Bluetooth : [(0.955 / 5) * √2.402] = 0.296 (≤ 3.0) Bluetooth LE : [(0.541 / 5) * √2.402] = 0.168 (≤ 3.0) Result : As a result of the calculation above, the SAR test is exempt.
TEST REPORT CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-00075 Page (1) / (38) Pages CTK-D151-06 R101 Rev.0 1. Client ◦ Name : ANOTO KOREA Corp. ◦ Address : Uspace2 #B-703, 670, Daewangpangyo-ro Bundang-gu, Seongnam-si, Gyeonggi-do, Korea 2. Manufacturer ◦ Name : ANOTO KOREA Corp. ◦ Address : Uspace2 #B-703, 670, Daewangpangyo-ro Bundang-gu, Seongnam-si, Gyeonggi -do, Korea 3. Use of Report : For FCC Certification and Canadian Certification 4. Test Sample / Model : Digital Pen / ANDANTE 5. Date of Test : 2019-12-20 to 2019-12-27 6. Test Standard(method) used : FCC 47 CFR part 15 subpart C 15.247, RSS-Gen Issue 5, RSS-247 Issue 2, ANSI C63.10-2013 7. Testing Environment : Temp.: (21 ± 5) °C, Humidity: (48 ± 3) % R.H. 8. Test Results : Compliance The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be reproduced, except in full. Affirmation Tested by Bong-seok Kim: (Signature) Technical Manager Young-taek Lee: (Signature) 2020-01-02 Republic of KOREA CTK Co., Ltd. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-00075 Page (2) / (38) Pages CTK-D151-06 R101 Rev.0 REPORT REVISION HISTORY Date Revision Page No 2020-01-02 Issued (CTK-2020-00075) all This report shall not be reproduced except in full, without the written approval of CTK Co., Ltd. This document may be altered or revised by CTK Co., Ltd. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by CTK Co., Ltd. will constitute fraud and shall nullify the document. CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-00075 Page (3) / (38) Pages CTK-D151-06 R101 Rev.0 CONTENTS 1. General Product Description ........................................................................................ 4 1.1 Client Information .............................................................................................. 4 1.2 Product Information ............................................................................................ 4 1.3 Peripheral Devices .............................................................................................. 4 2. Facility and Accreditations ........................................................................................... 5 2.1 Test Facility........................................................................................................ 5 2.2 Laboratory Accreditations and Listings .................................................................. 5 2.3 Calibration Details of Equipment Used for Measurement .......................................... 5 3. Test Specifications ..................................................................................................... 6 3.1 Standards.......................................................................................................... 6 3.2 Mode of operation during the test ......................................................................... 6 3.3 Maximum Measurement Uncertainty ..................................................................... 7 3.4 Test Software ..................................................................................................... 7 4. Technical Characteristic Test ........................................................................................ 8 4.1 6dB Bandwidth ................................................................................................... 8 4.2 Maximum peak Conducted Output Power ............................................................. 14 4.3 Power Spectral Density ..................................................................................... 17 4.4 Band Edge & Conducted Spurious emission .......................................................... 20 4.5 Radiated Emission ............................................................................................ 25 4.6 AC Power Line Conducted Emissions ................................................................... 35 APPENDIX A – Test Equipment Used For Tests ................................................................. 38 CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-00075 Page (4) / (38) Pages CTK-D151-06 R101 Rev.0 1. General Product Description 1.1 Client Information Company ANOTO KOREA Corp. Contact Point Uspace2 #B-703, 670, Daewangpangyo-ro Bundang-gu, Seongnam- si, Gyeonggi-do, Korea Contact Person Name : Chulmin, In E-mail : [email protected] Tel : +32-600-0824 1.2 Product Information FCC ID ADM-ANDANTE IC 23775-ANDANTE Product Description Digital Pen Model name ANDANTE Operating Frequency 2 402 MHz - 2 480 MHz RF Output Power -4.77 dBm (0.333 mW) Antenna Specification Antenna type : Chip Antenna Peak Gain : 2.1 dBi Number of channels 40 Channel Spacing 2 MHz Type of Modulation GFSK Power Source DC 3.7 V 1.3 Peripheral Devices - For Conducted Measurement and Radiated Measurement Device Manufacturer Model No. Serial No. Note Computer SAMSUNG NT560XBV 0Z8S91AM400511W AC/DC Adapter SAMSUNG A13-040N2A AD-4019A CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 Report No.: CTK-2020-00075 Page (5) / (38) Pages CTK-D151-06 R101 Rev.0 2. Facility and Accreditations 2.1 Test Facility The measurement facility is located at (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yong-in-si, Gyeonggi-do, Korea. 2.2 Laboratory Accreditations and Listings Country Agency Registration Number USA FCC 805871 CANADA ISED 8737A-2 KOREA NRRA KR0025 2.3 Calibration Details of Equipment Used for Measurement Test equipment and te…
Text truncated - open the document above for the full version.
CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Test Setup Photos and Configuration Radiated Electric Field Emissions CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com CTK Co., Ltd. (Ho-dong), 113, Yejik-ro, Cheoin-gu, Yongin-si, Gyeonggi-do, 449-100, Korea Tel: +82-31-339-9970 Fax: +82-31-624-9501 www.e-ctk.com Conducted Emissions Line Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 300.00 µW |

Digital Pen
Equipment Class
DTS - Digital Transmission System