Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 16, 2014
Application Purpose
Original Equipment
Date of Application
Oct 15, 2014
Equipment Note
Blood Glucose Meter
Frequency Range
2402.00000000 - 2480.00000000
Company
Bionime Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Preface 32 Preface Thank you for selecting the GE006 Blood Glucose Monitoring System. This manual provides all the information you need to operate this product for accurate test results. Please read this entire manual before you start any testing. For people living with diabetes, it is important to regularly monitor blood glucose levels to effectively reduce complications from the disease. The easy-to-use GE006 Blood Glucose Monitoring System provides accurate, reliable test results to help you better manage your diabetes. The GE006 Blood Glucose Monitoring System is designed for in vitro diagnostic use only (for self-testing by a single user outside the body). Testing requires only a small amount of fresh capillary whole blood from either the fingertip, palm or forearm. The GE006 Blood Glucose Monitoring System is manufactured and supported by Bionime Corporation. If you have any questions or concerns, please contact your local Bionime Customer Service or call us at 886 0800 241 688 GMT+08:00, 08:30~17:30. The GE006 Blood Glucose Monitoring System is a personal blood glucose monitoring system to be used for self-testing only. It is not recommended for multiple users. A healthcare professional should be contacted when Customer Service is not available. Caution 54 Precaution - Before using the GE006 Blood Glucose Monitoring System to test your blood glucose, please read all of the instructions and conduct all of the tests including the quality control test (Refer to page 37). - Please perform the quality control test regularly to make sure the test results are accurate. - The GE006 Blood Glucose Meter can only be used with GE006 Blood Glucose Test Strips. Other brands’ test strips should not be used under any circumstances. The use of other brands’ strips may give inaccurate results. - The GE006 Blood Glucose Monitoring System is intended for in vitro diagnostic use only. The GE006 Blood Glucose test results using fresh capillary whole blood samples from the fingertip, palm and forearm are calibrated to be the equivalent to that of plasma testing. - The GE006 Blood Glucose Monitoring System is intended for self-testing. It should not be used to screen for or diagnose diabetes mellitus. - If the GE006 Blood Glucose Meter and Test Strips are exposed to a substantial change in temperature, please wait 30 minutes before measurement . - Follow all environmental protection regulations when disposing of batteries. - Avoid contact with dripping or splashing liquids. - The minimum blood sample size to test using the GE006 Blood Glucose Monitoring System is 0.75μL: ( ) Blood sample size above 3.0μL might contaminate the test strip port and the meter. Blood sample size below 0.75μL may cause an inaccurate result or may prevent a meter reading. An Er4 reading will be displayed if the sample size is too small. In this case, repeat the test with a new test strip. Sample Size Example 0.75μL 1.0 1.5μL 2.0μLμL 3.0μL Important Safety Notes: - The GE006 Blood Glucose Meter and Lancing Device are for single patient use. Do not share them with anyone including other family members. - All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after following the cleaning and disinfecting procedures. - Users should wash their hands thoroughly with soap and water before and after handling the meter, lancing device, or test strips. Please refer to the section "Cleaning and Disinfecting Procedures" on page 47. Table of Contents 76 Table of Contents About the Blood Glucose Monitoring System The Blood Glucose Monitoring System ........................................................... The GE006 Blood Glucose Meter ................................................................................... The GE006 Blood Glucose Test Strip .......................................................................... Before Testing Meter Activation and Battery Change ...................................................................................... Setting Up Your Meter - Setting the Date, Time and Volume ............................................................... Turning On/Off the Meter ............................................................................................................... Turning On/Off the Bluetooth ..................................................................................................... Handling the GE006 Blood Glucose Test Strip .................................................................................. Testing Procedure Getting Ready for Testing .............................................................................................................. Performing a Blood Glucose Test ........................................................................................... Setting Markers ....... Alternative Site Testing ................................................................................................................... View Window Appearance .......................................................................................................... Understanding Test Results and Messages ............................................................................................................. GE006 GE006.......................................................... ............................................................. ............................................................... ................................................ ......................... ................................................ ................................................ ................................... ................................................ ................................................... ........................................................................................................................................................................... ................................................ .…

Text truncated - open the document above for the full version.

External Photos

Report No.: ER/2014/90018 FCC ID ADU-GM232: Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group EXTERNAL PHOTOGRAPHS OF EUT Report No.: ER/2014/90018 FCC ID ADU-GM232: Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group Front View of EUT Back View of EUT Report No.: ER/2014/90018 FCC ID ADU-GM232: Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group Side View of EUT – 1 Side View of EUT – 2 Report No.: ER/2014/90018 FCC ID ADU-GM232: Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8…

Text truncated - open the document above for the full version.

Internal Photos

Report No.: ER/2014/90018 FCC ID: ADU-GM232 Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group EXTERNAL PHOTOGRAPHS OF EUT Report No.: ER/2014/90018 FCC ID: ADU-GM232 Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group Internal View of EUT – 1 Internal View of EUT – 2 Report No.: ER/2014/90018 FCC ID: ADU-GM232 Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group Internal View of EUT – 3 Internal View of EUT – 4

RF Exposure Info

Report No.: ER/2014/90018 FCC ID:ADU-GM232 Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group RF EXPOSURE Standard Applicable According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Com- mission’s guideline. This is a Portable device with its physical nature to be used nearby, the distance between radiating structure and human is less than 20cm. As per KDB 447498 D01 $4.3.1, The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where 1 f (GHz) is the RF channel transmit frequency in GHz 2 Power and distance are rounded to the nearest mW and mm before calculation Measurement Result: Step 1: (<50mW) This is a portable device and the Max avg output power with upper tolerance is (1.11mW) lower than the threshold given and derived as formula given above, where For upper tolerance of max. output power, refer to operational description. =1.107(mW)/5 (mm)*√2.442 (GHz) = 0.346< 3.0 Frequency (MHz) Avg Power (dBm) Output Power (W) Limit (W) 2442 0.44 0.00111 1 Watt = 30 dBm As the result of calculation result indicates, the RF exposure generating from given transmitter (transmitter em- ployed digital modulation) can be excluded from SAR measurement, and is deemed compliant with RF exposure as per FCC. Report No.: ER/2014/90018 FCC ID:ADU-GM232 Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group The table of quick reference in terms of power threshold Note that the table present above is the table of quick reference, indexing the level of power threshold with respect to the corresponding frequency. The value of the index may be deviated, and therefore, the derivation of exemption based on KDB447498 D01 is used in this test report, relevantly. .

Test Report

ACX Advanced Ceramic X AT3216 Series Multilayer Chip Antenna Features ™ Monolithic SMD with small, low-profile and light-weight type. ™ Wide bandwidth Applications ™Bluetooth/Wireless LAN/Home RF ™ISM band 2.4GHz applications Specifications Part Number Frequency Range (MHz) Peak Gain (XZ-V) Average Gain (XZ-V) VSWR Impedance AT3216 -B2R7HAA_ 2400 ~ 2500 0.5 dBi typ. -0.5 dBi typ.2 max. 50 Ω Q’ty/Reel (pcs) : 3,000pcs Operating Temperature Range : -40 ~ +85 o C Storage Temperature Range : -40 ~ +85 o C Power Capacity : 3W max. Part Number AT 3216 - B 2R7 HAA ‡ ‡ i ghfe dc c Type AT : Antenna d Dimensions ( L × W ) 3.2× 1.6 mm e Material Code B f Frequency Range 2R7=2700MHz g Specification Code HAA h Packaging T: Tape & Reel B: Bulk i Soldering =lead-containing /LF=lead-free Terminal Configuration No. Terminal Name No. Terminal Name c Feeding Point d NC d c ACX Advanced Ceramic X Dimensions and Recommended PC Board Pattern Unit : mm a W T L Mark L W T a Dimensions 3.2±0.2 1.6±0.2 1.3+ 0.1/-0.2 0.5±0.3 (a) Without Matching Circuits (b) With Matching Circuits 1.2pF 3.3nH 2.6 4.2 1.6 1.9 2.7nH 0.4 * *Line width should be designed to match 50Ω characteristic impedance, depending on PCB material and thickness. ACX Advanced Ceramic X Typical Electrical Characteristics (T=25 o C) ™Test Board Ground 13.5mm 6.5mm 39.5mm 4mm No Ground Matching Circuit 50Ω Feed Line 19mm Antenna 6.5mm ™Return Loss (a) Without Matching Circuits (b) With Matching Circuits ACX Advanced Ceramic X Radiation Patterns .... XZ cut @2.45GHz Vertical Horizontal YZ cut @2.45GHz Vertical Horizontal XZ-V/XZ-H YZ-V/YZ-H XY cut @2.45GHz Vertical Horizontal Z 270 o 0 o X Y XY-cut scanning direction Y 270 o 0 o X Z XZ-cut scanning direction Z X 0 o 270 Y YZ-cut scanning direction 180 180 180 o XY-V/XY-H 90 o 90 o 90 o Advanced Ceramic X Corp. 16 Tzu Chiang Road, Hsinchu Industrial District Hsinchu Hsien 303, Taiwan TEL:886-3-5987008 FAX:886-3-5987001 E-mail: [email protected] http://www.acxc.com.tw

Test Report

Report No.: ER/2014/90018 FCC ID: ADU-GM232 Issue Date: Sep. 30, 2014 Page: 1 of 58 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C REQUIREMENT OF Product Name: Blood Glucose Meter Marketing Name: GE006 Brand Name: GE / Rightest Model No.: GE006 / GM232 Model Difference: By customer named FCC ID: ADU-GM232 Report No.: ER/2014/90018 Issue Date: Sep. 30, 2014 FCC Rule Part: §15.247, Cat: DTS Prepared for: BIONIME CORPORATION No.100, Sec.2, Daqing St., South Dist., Taichung City 40242, Taiwan(R.O.C) Prepared by: SGS Taiwan Ltd. Electronics & Communication Laboratory No.134, Wu Kung Road, New Taipei Industrial Park, Wuku District, New Taipei City, Taiwan 24803 Note: This report shall not be reproduced except in full, without the written approval of SGS Taiwan Ltd. This doc- ument may be altered or revised by SGS Taiwan Ltd. per- sonnel only, and shall be noted in the revision section of the document. Report No.: ER/2014/90018 FCC ID: ADU-GM232 Issue Date: Sep. 30, 2014 Page: 2 of 58 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or ap- pearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. SGS Taiwan Ltd. No.134,WuKungRoad,NewTaipeiIndustrialPark,WukuDistrict,NewTaipeiCity,Taiwan24803/北北路134 t (8862) 22993279 f (8862) 22980488 www.tw.sgs.com Member of SGS Group VERIFICATION OF COMPLIANCE Applicant: BIONIME CORPORATION No.100, Sec.2, Daqing St., South Dist., Taichung City 40242, Tai- wan(R.O.C) Product Name: Blood Glucose Meter Market Name: GE006 Brand Name: GE / Rightest Model No.: GE006 / GM232 Model Difference: By customer named File Number: ER/2014/90018 FCC ID: ADU-GM232 Date of test: Sep. 03, 2014 ~ Sep. 30, 2014 Date of EUT Received: Sep. 03, 2014 We hereby certify that: The above equipment was tested by SGS Taiwan Ltd. Electronics & Communication Laboratory The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4:2009 the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rules Part 15.247. The test results of this report relate only to the tested sample identified in this report. Test By: Date: Sep. 30, 2014 Marcus Tseng / Engineer Prepared By: Date: Sep. 30, 2014 Allen Tsai / Engineer Approved By: Date: Sep. 30, 2014 Jim Chang / Supervisor Report No.: ER/2014/90018 FCC ID: ADU-GM232 Issue Date: Sep. 30, 2014 Page: 3 of 58 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under th…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: ER/2014/90018 FCC ID:ADU-GN232 Issue Date: Sep. 30, 2014 Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 說留不 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for elec- tronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdict…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jen Huang(QSS Assistant Manager)
[email protected]886-4-23692388Fax: 886-4-22617586

Technical Contact

SGS Taiwan Ltd.Willis Chen
[email protected]886-2-22993279

134, Wu Kung Road,Wuku Industrial · Taiwan

Non-Technical Contact

SGS Taiwan Ltd.Willis Chen
[email protected]886-2-22993279

Test Firm

SGS Taiwan Ltd.Jason Lin
[email protected]886-2-2299-3279Fax: 886 2 2298 2248

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.

Other Applications from Bionime Corporation

Blood Glucose Monitoring System - FCC ID ADU-MAXTEL - Bionime Corporation
ADU-MAXTEL

Blood Glucose Monitoring System

Sep 27, 2022

Equipment Class

PCB - PCS Licensed Transmitter
Blood Glucose Meter - FCC ID ADU-GM700PRO2 - Bionime Corporation
ADU-GM700PRO2

Blood Glucose Meter

Jul 12, 2021

Equipment Class

DTS - Digital Transmission System
Receiver for CGM - FCC ID ADU-HR310 - Bionime Corporation
ADU-HR310

Receiver for CGM

Nov 22, 2020

Equipment Class

DTS - Digital Transmission System
RIGHTEST Continuous Glucose Monitoring System (CGMS) - FCC ID ADU-HM312 - Bionime Corporation
ADU-HM312

RIGHTEST Continuous Glucose Monitoring System (CGMS)

Nov 09, 2020

Equipment Class

DTS - Digital Transmission System
Blood Glucose Meter - FCC ID ADU-GM232C - Bionime Corporation
ADU-GM232C

Blood Glucose Meter

Sep 22, 2015

Equipment Class

DTS - Digital Transmission System