AMWUT051PORTABLE FRS/GMRS PTT RADIO

Uniden America Corporation
PORTABLE FRS/GMRS PTT RADIO - FCC ID AMWUT051 - Uniden America Corporation
Click to zoom

Application Details

Equipment Class
FRF - Part 95 Family Radio Face Held Transmitter
Date of Grant
Nov 11, 2010
Application Purpose
Original Equipment
Date of Application
Nov 10, 2010
Equipment Note
PORTABLE FRS/GMRS PTT RADIO
Frequency Range
462.56250000 - 467.71250000
Company
Uniden America Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GMR2838-2CK 5 6 7 8 9 10 11 12 13 14 15 22 16 17 18 19 20 21 23 24 CHARGE *Range may vary depending on environmental and/or topographical conditions. • 15 GMRS / 7 FRS Channels • 121 Sub Codes (CTCSS Tone and DCS Code) • Up to 28 Mile Range* • Internal VOX Circuitry • 5 Selectable Call Tone Alerts • Backlit LCD Display • Optional Headset Accessories • Headset Jack 1 Antenna 2 PTT (Push-To-Talk) Button 3 Monitor Button 4 Channel Up/Down key 5 Call Key 6 Headset Jack 7 DC IN 9V 8 Menu/Power key 9 Volume Up/Down key 10 Microphone 11 Speaker 12 Battery Level Meter 13 Receive Indicator 14 Call Indicator 15 Scan Indicator 16 Hi Power Indicator 17 Low Power Indicator 18 Transmit Indicator 19 Volume Setting Indicator 20 Keypad Lock Indicator 21 VOX Indicator 22 Channel Indicator 23 Sub Code Indicator 24 Charging Contacts Congratulations on your purchase of the Uniden GMR2838-2CK (General Mobile Radio Service) waterproof radio. This lightweight, palm-sized, radio is a state-of-the-art device, equipped with many valuable features. Use it at sporting events, to stay in contact with family and friends, hiking, skiing, outdoors, or in a neighborhood watch for vital communication - even outside by the pool! Your radio complies with JIS4 water-proof standards, which means the radio is resistant to damage from light rain or water spray from all sides. • The radio will only meet this rating if fully assembled and all rubber seals and the jack cover is well maintained and correctly fitted. This means that the Headset plug is not inserted, and the Headset jack cover and the battery pack are attached and securely fastened. Note: If your radio is exposed to salt water, clean your radio thoroughly with a small amount of fresh water (do not submerse it) , and dry it before turning it on. PACKAGE CONTENTS Your package contains two radios, two rechargeable NiMH battery packs (#BP40), one AC adapter (#AD- 0001), one charging cradle (#RC1284), two belt clips and this reference guide. You can operate the unit using the rechargeable NiMH battery pack. To order the following optional accessories, visit our web site at www.uniden.com or call 1-800-554-3988 during regular business hours. Use only Uniden accessories. • NiMH Battery Pack - #BP40 • Charging Cradle - #RC1284 • Headset - #ZA-133 • AC Adapter - #AD-0001 • DC Adapter - #DC-1002 GMRS LICENSE The radio operates on the General Mobile Radio Service (GMRS) frequencies when using Channels 1-7 and channels 15-22. You must have a GMRS license issued by the Federal Communications Commission to legally use these channels. For licensing information and application forms, visit the FCC online at: www. fcc.gov/wtb/uls or call the FCC hotline at 1-800-418-3676. If you have any questions, you can contact the FCC direct at 1-888-225-5322. No license is required for operation on channels 8-14 or operation on any channel in Canada. INSTALL THE BATTERY Your radio uses a supplied NiMH battery pack. To install the NiMH battery pack: 1) Make sure your radio is OFF. 2) Release the battery latch at the bottom of the radio, and remove the cover. 3) Install the NiMH battery pack into the battery compartment. Be certain to follow the instructions written on the label on the battery pack. Installing the battery pack incorrectly will prevent the unit from operating. 4) Before placing the battery cover back on the radio, check the rubber seal around the battery compartment and the ribbon of the battery pack: make sure that the seal is in good condition and that there is no foreign matter under the seal. 5) Replace the battery compartment door. Note: If the rubber seal appears worn, nicked, or dried out, replacement seals are available from www.uniden.com or call 1-800-554-3988 during business hours. USING THE RADIO • Roger Beep • Battery Charger • Battery Level Meter • Channel Monitor • Channel Scan • Keypad Lock • DC IN 9V Jack BATTERY LEVEL AND LOW BATTERY ALERT This unit has a battery level meter on the display to indicate the status of the batteries. When the battery in the unit is low, the battery level meter icon flashes. Recharge the NiMH battery pack immediately. Warning! To avoid the risk of personal injury or property damage from fire or electrical shock, only use the Uniden accessories specifically designated for this product. GMR2838-2CK RADIO CHARGING THE RADIO 2) Charge the battery pack for 16 hours until the battery indicator stops flashing. Using the Charging Cradle 1) Connect the AC adapter (#AD-0001) to DC IN 9V jack and to a standard 120V AC wall outlet. 2) Set the charging cradle on the desk or tabletop, and place the radio in the charging cradle with the keypad facing forward. 3) Make sure that the LED illuminates. Charge the battery pack for 16 hours and remove the radio from the charging cradle after charging. Note: • For charging batteries directly without the cradle, use only the #DC-1002 Cigarette Lighter Adapter cord, available from www.Uniden.com. Other power cords could damage your radio. • DC IN 9V Jack of the radio is for charge only. Be sure to install the battery before charge. • Use only the supplied battery and AC adapter or approved accessories from Uniden. • Charge time may vary depending on the battery life remaining. • For fastest charging, turn off the radio before charging. • Battery must be installed for operation, even from external power. • If battery Power is low, you cannot operate the radio even using external power. Allow the batteries to charge before using. If you try to transmit while power is low, the radio will automatically turn off. Warrning! : • The charging cradle is not waterproof. If the charging cradle falls into water, unplug it before attempting to remove it from the water. Allow the cradle to dry completely before reconnecting the power. • Wipe off dirt or shake water from your radio before placing in the charging cradle if your radio is soiled or wet. Adjusting the Sound (Key Beeps) Your radio emits a beep each time one of th…

Text truncated - open the document above for the full version.

Cover Letter(s)

Celltech Labs Inc. 21-364 Lougheed Road, Kelowna, B.C. Canada V1X 7R8 Tel. 250-765-7650 • Fax. 250-765-7645 • e-mail: [email protected] www.celltechlabs.com Date: November 9, 2010 Timco Engineering, Inc. Telecommunication Certification Body 849 NW State Road 45 Newberry, FL 32669 SUBJECT: Uniden America Corporation FCC ID: AMWUT051 Parts 95A/B - Certification On behalf of Uniden America Corporation is an application for Parts 95A/B Certification of the Portable FRS/GMRS Push- To-Talk (PTT) Radio Transceiver described below. This device has been tested and complies with the requirements for certification under FCC Rule Parts 95A/B. Device Classification: Part 95 Family Radio Face Held Transmitter (FRF) Device Description: Portable FM FRS/GMRS PTT Radio Transceiver Model Name / No.(s): GMR2838 Frequency Range(s): 462.5500 - 462.7250 MHz (GMRS Channels 15-22) 462.5625 - 462.7125 MHz (GMRS/FRS Channels 1-7) 467.5625 - 467.7125 MHz (FRS Channel 8-14) Antenna Type: Fixed External (Non-detachable) RF Output Power Measured: 0.75 Watts ERP (GMRS) 0.27 Watts ERP (FRS) Submitted within this application is the TCB Form 731, applicant’s authorization letter, applicant’s long-term confidentiality request, FCC Parts 95A/B measurement report and test setup photographs, SAR RF Exposure measurement report and test setup photographs, FCC ID label and location, internal and external device photographs, block diagram (confidential), schematic diagrams (confidential), circuit description (confidential) and the user manual. If you have any questions or comments concerning the above, please contact the undersigned. Sincerely, Jonathan Hughes Project Manager Celltech Labs Inc. cc: Uniden America Corporation

Cover Letter(s)

REQUEST FOR LONG-TERM CONFIDENTIALITY November 8, 2010 To: Federal Communications Commission Equipment Authorization Branch Laboratory Division Office of Engineering and Technology 7435 Oakland Mills Road Columbia, Maryland 21046 Subject: Data for FCC Certification under Part 95 Applicant: Uniden America Corporation 4700 Amon Carter Blvd., Fort Worth, Texas 76155 Jon Suehiro, Engineering and Regulatory Affairs TYPE OF EQUIPMENT: FRS/GMRS Hand Held Transmitter FCC IDENTIFIER: AMWUT051 Dear Sir or Madam: Some of the material included in this application contains trade secrets and proprietary information not customarily released to the public. Because public disclosure of the material might be harmful to the applicant and provide unjustified benefits to its competitors, it is requested that the following be withheld from public disclosure: Circuit Description (File Name: UT051 Circuit Description - CONFIDENTIAL.pdf) Schematic Diagrams (File Name: UT051 Schematic Diagrams - CONFIDENTIAL.pdf) Block Diagram (File Name: UT051 Block Diagram - CONFIDENTIAL.pdf) Trade secrets and proprietary information can be held confidential. Therefore, we wish to invoke the act under the provisions of 47CFR, Sections 0.457(d) and 0.459. Please contact the undersigned if you have any questions or need any further information. Regards, Jon Suehiro Engineering and Regulatory Affairs Uniden America Corporation 4700 Amon Carter Blvd., Fort Worth, Texas 76155

Cover Letter(s)

Uniden America Corporation 4700 Amon Carter Blvd. Fort Worth, TX 76155 817-858-3300 Fax: 817-858-3328 LIMITED AGENCY AGREEMENT November 4, 2010 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Attn: Director of Certification RE: Equipment Authorization for FCC Certification We, Uniden America Corporation (hereinafter “Uniden”), hereby authorize Jonathan Hughes, Product Manager of Celltech Labs, Inc., located at 21-364 Lougheed Road in Kelowna, BC V1X 7R8, to act as our agent for the purpose of testing and preparing an equipment authorization application for our device identified by the FCC Certification number AMWUT051 under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is today, November 4, 2010. This limited agency agreement expires on November 4, 2011, unless sooner terminated or extended by written notice to Celltech Labs, Inc. and Federal Communications Commission. Uniden certifies that equipment manufactured, imported, or marketed under the FCC Certification number AMWUT051 will comply with the parameters established in the application for equipment authorization unless the changes are in full compliance to the provisions in the FCC Rules and Regulations that allow such changes. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by Celltech Labs, Inc., resides with Uniden America Corporation located at 4700 Amon Carter Blvd, Fort Worth, Texas 76155. Uniden America Corporation 4700 Amon Carter Blvd. Fort Worth, TX 76155 817-858-3300 Fax: 817-858-3328 If you have any questions or comments, please do not hesitate to contact me. Regards, Jon Suehiro Manager, Engineering and Regulatory Affairs

Cover Letter(s)

Celltech Labs Inc. 21-364 Lougheed Road, Kelowna, B.C. Canada V1X 7R8 Tel. 250-765-7650 • Fax. 250-765-7645 • e-mail: [email protected] www.celltechlabs.com Date: November 16, 2010 Timco Engineering, Inc. Telecommunication Certification Body 849 NW State Road 45 Newberry, FL 32669 SUBJECT: Uniden America Corporation FCC ID: AMWUT051 (Timco Job No. 2571UC10) IC: 513C-UT051 ((Timco Job No. 2572IC10) We hereby request for the user manual exhibit originally submitted with this application to be superseded with the attached revised user manual. The originally submitted user manual inadvertently contains a text box placed over diagrams and text on page 1. Please refer to the revised user manual with text box removed and replace the original user manual submitted. If you have any questions or comments concerning the above, please contact the undersigned. Thank you. Sincerely, Jonathan Hughes Project Manager Celltech Labs Inc. cc: Uniden America Corporation

External Photos

Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 EXTERNAL DUT PHOTOGRAPHS Front Side of DUT Back Side of DUT Back Side of DUT with Plastic Belt-Clip Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 EXTERNAL DUT PHOTOGRAPHS DUT with Headset/Boom-Microphone audio accessory (P/N: ZA-133) Plastic Belt-Clip accessory Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 EXTERNAL DUT PHOTOGRAPHS Top end of DUT Bottom end of DUT Left and Right Sides of DUT Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 EXTERNAL DUT PHOTOGRAPHS DUT with Ni-MH Battery Pack installed DUT with Ni-MH Battery Pack removed Front Side of Ni-MH Battery Pack Model: BP40 Back Side of Ni-MH Battery Pack Model: BP40

ID Label/Location Info

UT052.DOC 1 ID Label/Location Info The FCC Label complies with the section 2.925(d) of the FCC Rules and will be placed in the battery compartment due to limited space. This label will be readily visible at the time of purchase. 1) Rating label: 32 mm (W) x 7.2 mm (H) 2) STATEMENT label: 32 mm (W) x 17 mm (H) MODEL: MODEL: MODEL: MODEL: GMR2838 GMR2838GMR2838 GMR2838 FCC ID: AMWUT051 FCC ID: AMWUT051 FCC ID: AMWUT051 FCC ID: AMWUT051 MADE IN MADE IN MADE IN MADE IN VIETNAM VIETNAMVIETNAM VIETNAM IC: 513C IC: 513CIC: 513C IC: 513C- -- -UT051 UT051UT051 UT051

Internal Photos

Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 INTERNAL DUT PHOTOGRAPHS Bottom Side of PCB (with shielding) Bottom Side of PCB (shielding removed) Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 INTERNAL DUT PHOTOGRAPHS VCO Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 INTERNAL DUT PHOTOGRAPHS Top Side of PCB (with LCD Display) Top Side of PCB (LCD Display removed)

RF Exposure Info

Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 2010 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc. Page 1 of 32 Date(s) of Evaluation November 03, 2010 Test Report Serial No. 110310AMW -T1060-E95U Test Report Revision No. Rev. 1.0 (Initial Release) Test Report Issue Date November 09, 2010 Description of Test(s) Specific Absorption Rate RF Exposure Category Gen. Pop. / Uncontrolled Test Lab Certificate No. 2470.01 DECLARATION OF COMPLIANCE - SAR RF EXPOSURE EVALUATION (FCC/IC) Name CELLTECH LABS INC. Test Lab Information Address 21-364 Lougheed Road, Kelowna, British Columbia V1X 7R8 Canada Test Lab Accreditation(s) A2LA ISO/IEC 17025:2005 (A2LA Test Lab Certificate No. 2470.01) Name UNIDEN AMERICA CORPORATION Applicant Information Address 4700 Amon Carter Boulevard, Fort Worth, Texas 76155 United States Application Type(s) FCC TCB Certification IC CB Certification FCC 47 CFR §2.1093 Standard(s) Applied IC Health Canada Safety Code 6 OET Bulletin 65, Supplement C (Edition 01-01) FCC KDB 447498 D01v04 IC RSS-102 Issue 4 IEEE1528-2003 Procedure(s) Applied IEC62209-1:2005 FCC ID: AMWUT051 Device Identifier(s) IC:513C-UT051 Date of Sample Receipt November 03, 2010 Date(s) of Evaluation November 03, 2010 Device Model(s) GMR2838 Test Sample Serial No. None (Identical Prototype) Hardware / Firmware Revision No.s Hardware EPP Stage Firmware EPP Stage Device Description Portable FM UHF GMRS/FRS Push-To-Talk (PTT) Radio Transceiver 462.5500 - 462.7250 MHz (GMRS Channels 15-22) 462.5625 - 462.7125 MHz (GMRS/FRS Channels 1-7) Transmit Frequency Range(s) 467.5625 - 467.7125 MHz (FRS Channels 8-14) 0.75 W 28.75 dBm ERP462.5625 MHz GMRS Ch. 1 RF Output Power Measured 0.27 W 24.31 dBm ERP467.5625 MHz FRS Ch. 8 Battery Type(s) Tested Ni-MH Battery Pack 4.8 V 550 mAh Model: BP40 Antenna Type(s) Tested External Non-detachable (-0.5 dBi Gain) Body-worn Accessories Tested Plastic Belt-Clip (supplied with DUT) Audio Accessories Tested Headset-Microphone (P/N: ZA-133) Face-held 0.655 W/kg 1g50% PTT duty cycle Max. SAR Level(s) Evaluated Body-worn 0.500 W/kg 1g50% PTT duty cycle FCC/IC Spatial Peak SAR Limit Head/Body 1.6 W/kg1g50% PTT duty cycle General Population / Uncontrolled RF Exposure Environment Celltech Labs Inc. declares under its sole responsibility that this wireless portable device has demonstrated compliance with the Specific Absorption Rate (SAR) RF exposure requirements specified in FCC 47 CFR §2.1093 and Health Canada’s Safety Code 6 for the General Population / Uncontrolled Exposure environment. The device was tested in accordance with the measurement procedures specified in FCC OET Bulletin 65, Supplement C (Edition 01-01), Industry Canada RSS-102 Issue 4, IEEE Standard 1528-2003 and International Standard IEC 62209-1:2005. All measurements were performed in accordance with the SAR system manufacturer recommendations. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of m y knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results and statements contained in this report pertain only to the device(s) evaluated. This test report shall not be reproduced partially, or in full, without the prior written approval of Celltech Labs Inc. Test Report Approved BySean JohnstonLab ManagerCelltech Labs Inc Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable GMRS/FRS UHF PTT Radio Transceiver DUT Model(s): GMR2838 2010 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc. Page 2 of 32 Date(s) of Evaluation November 03, 2010 Test Report Serial No. 110310AMW -T1060-E95U Test Report Revision No. Rev. 1.0 (Initial Release) Test Report Issue Date November 09, 2010 Description of Test(s) Specific Absorption Rate RF Exposure Category Gen. Pop. / Uncontrolled Test Lab Certificate No. 2470.01 TABLE OF CONTENTS 1.0 INTRODUCTION ___________________________________________________________________ 4 2.0 SAR MEASUREMENT SYSTEM ______________________________________________________ 4 3.0 REFERENCE OUTPUT POWER MEASUREMENT ________________________________________ 4 4.0 SAR MEASUREMENT SUMMARY_____________________________________________________ 5 5.0 DETAILS OF SAR EVALUATION______________________________________________________ 6 6.0 SAR EVALUATION PROCEDURES____________________________________________________ 6 7.0 SYSTEM PERFORMANCE CHECK ____________________________________________________ 7 8.0 SAR PROBE CALIBRATION & MEASUREMENT FREQUENCIES ___________________________ 8 9.0 SIMULATED EQUIVALENT TISSUES __________________________________________________ 8 10.0 SAR LIMITS _____________________________________________________________________ 8 11.0 ROBOT SYSTEM SPECIFICATIONS __________________________________________________ 9 12.0 PROBE SPECIFICATION (ET3DV6) _________________________________________________ 10 13.0 BARKSI PLANAR PHANTOM ______________________________________________________ 10 14.0 DEVICE HOLDER ________________________________________________________________ 10 15.0 TEST EQUIPMENT LIST __________________________________________________________ 11 16.0 MEASUREMENT UNCERTAINTIES__________________________________________________ 12 17.0 REFERENCES __________________________________________________________________ 13 APPENDIX A - SAR MEASUREMENT DATA _______________________________________________ 14 APPENDIX B - SYSTEM PERFORMANCE CHECK DATA____________________________________ 19 APPENDIX C - MEASURED FLUID DIELECTRIC PARAMETERS ______________________________ 22 APPENDIX D - SAR TEST SETUP PHOTOGRAPHS ___________…

Text truncated - open the document above for the full version.

Test Report

Test Report Serial No.: 110310AMW -T1060-E95U Test Report Issue Date: November 9, 2010 Measurement Date(s): November 03-04, 2010 Test Report Revision No.: Revision 1.0 Rule Part(s) Applied: FCC 47 CFR §2, §95A, §95B Industry Canada RSS-210 (I7), RSS-Gen (I2) Test Site Registration(s): FCC Site Registration #: 714830 Industry Canada Site File #: IC 3874A-1 Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable FRS/GMRS PTT Radio Transceiver DUT Model(s): GMR2838 2010 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc. Page 1 of 31 DECLARATION OF COMPLIANCE - FCC PART 95(A/B) & IC RSS-210 (Issue 7) Name CELLTECH LABS INCORPORATED Test Lab Information Address 21-364 Lougheed Road, Kelowna, British Columbia V1X 7R8 Canada Test Site Registration No.(s) FCC 714830 IC 3874A-1 Name UNIDEN AMERICA CORPORATION Applicant Information Address 4700 Amon Carter Boulevard, Fort W orth, Texas 76155 United States FCC 47 CFR Part 2 47 CFR Part 95 Subpart A 47 CFR Part 95 Subpart B IC RSS-210 Issue 7 RSS-Gen Issue 2 Standard(s) & Procedure(s) ANSI TIA/EIA-603-C-2004 C63.4-2003 FCC Part 95 Family Face Held Transmitter (FRF) 47 CFR §95 (Subpart A/B) Device Classification(s) IC Low-power Licence-exempt Radiocommunication Device RSS-210 Issue 7 Device Category FCC/IC Portable RF Exposure Category General Population / Uncontrolled Application Type FCC/IC Certification FCC ID: AMW UT051 Device Identifier(s) IC: 513C-UT051 Device Under Test (DUT) Portable FM FRS/GMRS UHF Push-To-Talk (PTT) Radio Transceiver Device Model(s) GMR2838 Date of Sample Receipt November 03, 2010 Date(s) of Evaluation November 03-04, 2010 Test Sample Serial No.(s) None (Conducted Tests) - Identical Prototype None (Radiated Tests) - Identical Prototype Hardware / Firmware Revision No.s Hardware EPP Stage Firmware EPP Stage Number of Channels 22 462.5500 - 462.7250 MHz (GMRS Channels 15-22) 462.5625 - 462.7125 MHz (GMRS/FRS Channels 1-7) Transmit Frequency Range(s) 467.5625 - 467.7125 MHz (FRS Channels 8-14) Mode Frequency Channel dBm Watts Method GMRS 462.5625 MHz 1 28.75 0.75 ERP Max. RF Output Power Tested FRS 467.5625 MHz 8 24.31 0.27 ERP Modulation Type(s) FM Emission Designator(s) 11K0F3E Antenna Type(s) Tested External Non-detachable Antenna Gain Specification -0.5 dBi Power Source(s) Tested NiMH Battery Pack 4.8 V 550 mAh Model: BP40 This wireless device has demonstrated compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in FCC 47 CFR Rule Part 2, Part 95 Subpart A, Part 95 Subpart B; Industry Canada RSS-210 Issue 7, RSS-Gen Issue 2; ANSI TIA/EIA-603-C-2004 and ANSI C63.4-2003. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all pers ons taking them. The results and statements contained in this report pertain only to the device(s) evaluated. This test report shall not be reproduced partially, or in full, without the prior written approval of Celltech Labs Inc. Test Report Approved By Sean Johnston Lab Manager Celltech Labs Inc. Test Report Serial No.: 110310AMW -T1060-E95U Test Report Issue Date: November 9, 2010 Measurement Date(s): November 03-04, 2010 Test Report Revision No.: Revision 1.0 Rule Part(s) Applied: FCC 47 CFR §2, §95A, §95B Industry Canada RSS-210 (I7), RSS-Gen (I2) Test Site Registration(s): FCC Site Registration #: 714830 Industry Canada Site File #: IC 3874A-1 Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable FRS/GMRS PTT Radio Transceiver DUT Model(s): GMR2838 2010 Celltech Labs Inc. This document is not to be reproduced in whole or in part without the prior written permission of Celltech Labs Inc. Page 2 of 31 TABLE OF CONTENTS 1.0 SCOPE.......................................................................................................................................................... 4 2.0 REFERENCES .............................................................................................................................................. 4 2.1 Normative References ................................................................................................................................... 4 3.0 PASS/FAIL CRITERIA ................................................................................................................................... 4 4.0 FACILITIES AND ACCREDITATIONS........................................................................................................... 5 5.0 GENERAL INFORMATION............................................................................................................................ 5 5.1 Applicant Information ..................................................................................................................................... 5 5.2 DUT Description ............................................................................................................................................ 5 5.3 Rule Part(s) & Classification(s) ...................................................................................................................... 5 5.4 Mode(s) of Operation Tested......................................................................................................................... 6 5.5 Modification(s) ............................................................................................................................................... 6 Appendix A RF Output Power Measurement.................................................................................................. 7 Appendix B Modulation Characteristics (Modulation Limiting)......…

Text truncated - open the document above for the full version.

Test Setup Photos

Applicant: Uniden America Corporation FCC ID: AMWUT051 IC: 513C-UT051 DUT Type: Portable FM GMRS/FRS PTT Radio Transceiver DUT Model(s): GMR2838 Celltech Project No.: 1060 TEST SETUP PHOTOGRAPHS

Contact Information

Applicant

Paul Roby
[email protected]817-858-3624Fax: 817-858-3333

Test Firm

Celltech Labs. IncBen Hewson
[email protected]250-765-7650Fax: 250-765-7645

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
295B462.5625 MHz - 467.7125 MHz270.00 mW11K0F3E2.5 ppm
Confidentiality
Long Term
Grant Notes
Listed Power is ERP. This device is authorized to operate in the following radio services: FRS (Part 95B) or GMRS (Part 95A). There must be an informational insert inside the box (product package) or the User�s Manual must include information that clearly informs the consumer (buyer/owner) when the radio is transmitting on GMRS frequencies, that operation on GMRS frequencies requires an FCC license and such operation is subject to additional rules specified in 47 C.F.R. Part 95. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific antennas / belt-clips / holsters / accessories tested for this device. Users must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device complies with OET Bulletin 65 for General Population use. The highest reported SAR levels are: Head: 0.66 W/kg for 50% Duty Cycle, Body 0.50 W/kg for 50% Duty Cycle

Other Applications from Uniden America Corporation

AMWUA2405

RADAR DETECTOR

Apr 15, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
AMWUA2406

RADAR DETECTOR

Apr 15, 2026

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
AMWUA2402

RADAR DETECTOR

Jul 23, 2024

Equipment Class

CRD - Part 15 Radar Detector
Wi-Fi Bluetooth Combo Module - FCC ID AMWUA2404 - Uniden America Corporation
AMWUA2404

Wi-Fi Bluetooth Combo Module

Feb 17, 2024

Equipment Class

DTS - Digital Transmission System
RADAR DETECTOR - FCC ID AMWUA2301 - Uniden America Corporation
AMWUA2301

RADAR DETECTOR

Feb 15, 2023

Equipment Class

CRD - Part 15 Radar Detector