
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Model Name: CDMA SH007 Photo (External) FCC ID: APYHRO00119 1/3 Model Name: CDMA SH007 Photo (External) FCC ID: APYHRO00119 2/3 Model Name: CDMA SH007 Photo (External) FCC ID: APYHRO00119 3/3
Model Name: CDMA SH007 FCC ID Location (On Spec Label) FCC ID:APYHRO00119 ○Spec Label ①,② Production Years & Month ③,④ Products Code ⑤,⑥ Production Number ⑦ Barcode of Production Number ⑧ Certification Number of TELEC ⑨ Approval Number of JATE ○Location Caution:Turn off power in aircrafts and hospitals. Don’t remove this label. ⑩ FCC ID: APYHRO00119 Vendor:KDDI Corp.・Okinawa Cellular Corp. Manufacture/Applicant: SHARP Corp. Made in China
Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 1/8 Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 2/8 Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 3/8 Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 4/8 Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 5/8 Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 6/8 Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 7/8 Model Name: CDMA SH007 Photo (Internal) FCC ID: APYHRO00119 8/8
Test report No. : 30EE0254-HO Page : 2 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ...................................................................................... 3 SECTION 2: Equipment under test (E.U.T.) ........................................................................ 3 SECTION 3: Test specification, procedures & results ......................................................... 4 SECTION 4: Operation of E.U.T. during testing ................................................................. 7 SECTION 5: Conducted Emission ......................................................................................... 9 SECTION 6: Radiated Emission .......................................................................................... 10 APPENDIX 1: Photographs of test setup............................................................................. 11 Conducted Emission .................................................................................................................... 11 Radiated Emission ....................................................................................................................... 12 Worst Case Position (Horizontal: X-axis/ Vertical:Y-axis) ..................................................... 13 APPENDIX 2: Data of EMI test ........................................................................................... 14 Conducted Emission .................................................................................................................... 14 Radiated Emission ....................................................................................................................... 16 APPENDIX 3: Test instruments ........................................................................................... 20 Test report No. : 30EE0254-HO Page : 3 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Sharp Corporation, Communication Systems Group Address : 2-13-1, Iida Hachihonmatsu, Higashi-Hiroshima City, Hiroshima, 739-0192 Japan Telephone Number : +81-82-420-1630 Facsimile Number : +81-82-420-1624 Contact Person : Hachiroh Hidaka SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Cellular Phone Model No. : CDMA SH007 Serial No. : Refer to Section 4, Clause 4.2 Receipt Date of Sample : March 2, 2010 Country of Mass-production : China (Guangdong Province) Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Model No: CDMA SH007 (referred to as the EUT in this report) is the Cellular Phone. Feature of EUT : Model No: CDMA SH007 is 1XEV-DO Hybrid CDMA Tri-Band Cellular Phone. CDMA SH007 is designed by Sharp Corporation exclusively for au, a cellular phone carrier owned by KDDI corporation in Japan. Clock frequency(ies) in the system : CPU: 19.2MHz, 384MHz RTC: 32.768kHz Test report No. : 30EE0254-HO Page : 4 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test specification Test specification : FCC Part 15 Subpart B: 2010, final revised on January 22, 2010 and effective March 1, 2010 Title : FCC 47CFR Part15 Radio Frequency Device Subpart B Unintentional Radiators 3.2 Procedures and results Item Test Procedure Limits Deviation Worst margin Result Conducted emission FCC: ANSI C63.4: 2003 7. AC powerline conducted emission measurements Class B N/A [QP] 16.8dB 0.20623MHz, L [AV] 13.1dB 1.03368MHz, N Complied Radiated emission FCC: ANSI C63.4: 2003 8. Radiated emission measurements Class B N/A 8.4dB 665.432MHz Horizontal Complied *Note: UL Japan, Inc’s EMI Work Procedure QPM05. 3.3 Addition to standard No addition, exclusion nor deviation has been made from the standard. Test report No. : 30EE0254-HO Page : 5 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 3.4 Uncertainty EMI The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2. Conducted emission (+dB) Test room (semi- anechoic chamber) 150kHz-30MHz No.1 2.6dB No.2 2.9dB No.3 3.3dB No.4 2.8dB Radiated emission Radiated emission (10m*)(+dB) (3m*)(+dB) (1m*)(+dB) Test room (semi- anechoic chamber) 9kHz -30MHz 30MHz -300MHz 300MHz -1GHz 9kHz -30MHz 30MHz -300MHz 300MHz -1GHz 1GHz -18GHz 18GHz -26.5GHz 26.5GHz -40GHz No.1 2.7dB 4.8dB 5.0dB 2.9dB 4.8dB 5.0dB 3.9dB 4.5dB 4.4dB No.2 - - - 3.5dB 4.8dB 5.1dB 4.0dB 4.3dB 4.2dB No.3 - - - 3.8dB 4.6dB 4.7dB 4.0dB 4.5dB 4.4dB No.4 - - - 3.5dB 4.4dB 4.9dB 4.0dB 4.6dB 4.5dB *10m/3m/1m = Measurement distance Conducted Emission test The data listed in this test report has enough margin, more than the site margin. Radiated emission test(3m) The data listed in this test report has enough margin, more than the site margin. Test report No. : 30EE0254-HO Page : 6 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 3.5 Test Location UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. code: 200572-0 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 FCC Registration Number IC Registration N…
Text truncated - open the document above for the full version.
Test report No. : 30EE0254-HO Page : 11 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Conducted Emission Photo 1 Photo 2 Test report No. : 30EE0254-HO Page : 12 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Radiated Emission Photo 1 Photo 2 Test report No. : 30EE0254-HO Page : 13 of 20 Issued date : March 11, 2010 FCC ID : APYHRO00119 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst Case Position (Horizontal: X-axis/ Vertical:Y-axis) X-axis Y-axis Z-axis
Sharp Plaza · Mahwah, New Jersey · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |
Smartphone
Equipment Class
DTS - Digital Transmission SystemSmart phone
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterSmart phone
Equipment Class
DTS - Digital Transmission SystemBT remote control
Equipment Class
DTS - Digital Transmission SystemSmart phone
Equipment Class
NII - Unlicensed National Information Infrastructure TX