FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sharp Corporation/
  3. APYHRO00180

APYHRO00180Cellular Phone

Sharp Corporation
Cellular Phone - FCC ID APYHRO00180 - Sharp Corporation
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 11, 2012
Application Purpose
Original Equipment
Date of Application
Nov 11, 2012
Equipment Note
Cellular Phone
Frequency Range
2412.00000000 - 2462.00000000
Company
Sharp Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ɜ ġ If you lose your handset or have it stolen, immediately take the steps necessary for suspending the use of the handset. ɜ ġ If the handset you purchased is damaged, bring your handset to a repair counter specified by DOCOMO after returning to Japan. Sales : Manufacturer : SHARP Corporation Don’t forget your mobile phone... or your manners! When using your mobile phone in a public place, don’t forget to show common courtesy and consideration for others around you. Universal number international prefixInternational call access codefor the country you stay -81-3-6718-1414 * (toll free) -8005931-8600 * From land-line phonesFrom DOCOMO mobile phones Failures encountered overseas <Network Support and Operation Center> <Universal number> * You might be charged a domestic call fee according to the call rate for the country you stay. ɦ For international call access codes for major countries and universal number international prefix, refer to DOCOMO International Services website. * You are charged a call fee to Japan when calling from a land-line phone, etc. ɦ If you use SH-01E, you should dial the number +81-3-6832-6600 (to enter “+”, touch “0” for a while). * You might be charged a domestic call fee according to the call rate for the country you stay. ɦ For international call access codes for major countries and universal number international prefix, refer to DOCOMO International Services website. * You are charged a call fee to Japan when calling from a land-line phone, etc. ɦ If you use SH-01E, you should dial the number +81-3-6718-1414 (to enter “+”, touch “0” for a while). -8000120-0151 * Universal number international prefix -81-3-6832-6600 * (toll free) International call access codefor the country you stay Loss or theft of handset or payment of cumulative cost overseas <docomo Information Center> From DOCOMO mobile phones From land-line phones <Universal number> (available 24 hours a day) (available 24 hours a day) ɦ Unavailable from land-line phones, etc. ɡ From DOCOMO mobile phones (In Japanese only) ɦ Unavailable from land-line phones, etc. (No prefix) 151 (toll free) ɡ From DOCOMO mobile phones (In Japanese only) Repairs (Business hours: 24 hours (open all year round)) (Business hours: 9:00 a.m. to 8:00 p.m.) ɦ Unavailable from part of IP phones. 0120-800-000 (toll free) ɡ From land-line phones (In Japanese only) 0120-005-250 (toll free) ɦ Service available in: English, Portuguese, Chinese, Spanish, Korean. (Business hours: 9:00 a.m. to 8:00 p.m. (open all year round)) ɦ Unavailable from part of IP phones. (No prefix) 113 (toll free) General Inquiries <docomo Information Center> ɜ Please confirm the phone number before you dial. ɜ For Applications or Repairs and After-Sales Service, please contact the above-mentioned information center or the docomo Shop e tc. near you on the NTT DOCOMO website. NTT DOCOMO website ȁ http://www.nttdocomo.co.jp/english/ ɦ Unavailable from part of IP phones. ɡ From land-line phones (In Japanese only) 0120-800-000 (toll free) INSTRUCTION MANUAL SH-01E ’12.9 (1st Edition) 12J SM193 ’12.9 1 㸭㸭∧ 6 Contents/Precautions Before use, read these “Precautions” carefully and use your handset properly. Keep this manual in a safe place for future reference. These precautions contain information intended to prevent bodily injury to the user and to surrounding people, as well as damage to property, and must be observed at all times. The following symbols indicate the different degrees of injury or damage that may occur if information provided is not observed and the handset is used improperly. The following symbols indicate specific directions. Precautions (ALWAYS FOLLOW THESE DIRECTIONS) Danger This symbol indicates that “death or serious bodily injury may directly and immediately result from improper use”. Warning This symbol indicates that “death or serious bodily injury may result from improper use”. Caution This symbol indicates that “minor injury and/or property damage may result from improper use”. Indicates a prohibited action. Indicates not to disassemble the device. Indicates not to use the device near water or get it wet. Indicates not to handle the device with wet hands. Indicates that instructions specified are compulsory (must be followed). Indicates that the power cord must be unplugged from the outlet. 7 Contents/Precautions “Precautions” is explained in the following six sections. Handling the handset, battery pack, adapters, desktop holder, docomo mini UIM card and 1Seg antenna cable (general) . . . . . . . . . . . . . . . . P. 7 Handling the handset . . . . . . . . . . . . . . . . . . P. 8 Handling battery pack . . . . . . . . . . . . . . . . . P. 11 Handling adapters and desktop holder . . . . P. 12 Handling docomo mini UIM card . . . . . . . . . P. 13 Handling near electronic medical equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P. 14 Do not use, store or leave the equipment in locations subject to high temperatures (near a fire or heating unit, in a kotatsu, under direct sunlight, inside a vehicle on a hot day, etc.). May cause fires, burns or bodily injury. Do not place the equipment inside cooking appliances such as microwave ovens or pressure cookers. May cause fires, burns, bodily injury or electric shock. Do not attempt to disassemble or modify the equipment. May cause fires, burns, bodily injury or electric shock. Do not get the equipment wet with water, drinking water, pet urine, etc. May cause fires, burns, bodily injury or electric shock. Refer to the following for details on waterproofness. n“Waterproof/Dust-proof” on P. 21 Use only the battery packs and adapters specified by NTT DOCOMO for use with the handset. May cause fires, burns, bodily injury or electric shock. Do not subject the equipment to strong force or impacts or throw it. May cause fires, burns, bodily injury or electric shock. Do not allow conductive materials (such as metal objects and pencil lead) to come into contact w…

Text truncated - open the document above for the full version.

External Photos

Model Name:SH-02E FCC ID: APYHRO00180 Photo(External)1/Nov/2012 1 / 11 / 1

ID Label/Location Info

1/Nov/2012 Model Name: SH-02E Spec Label and Location FCC ID: APYHRO00180 ○Spec Label Spec Label and Location Vendor : NTT DoCoMo ①① Color ② Approval Number of JATE ③ Certification Number of TELEC ④ Production Years & Months ⑤ Bar Code of IMEI ⑥ IMEI (Production Serial Number) ⑦ Country of production Caution : Turn off power in an aircraft. Don't remove this seal. Manufucturer/Applicant : SHARP Corporation FCC ID ○Location FCC ID ThFCCIDfthidi TheFCC ID for this device FCC ID: APYHRO00180 can be found under this cover.

Internal Photos

Model Name:SH-02E FCC ID: APYHRO00180 Photo(Internal)1/Nov/2012 1 / 5 Model Name:SH-02E FCC ID: APYHRO00180 Photo(Internal)1/Nov/2012 2 / 5 Model Name:SH-02E FCC ID: APYHRO00180 Photo(Internal)1/Nov/2012 3 / 5 Model Name:SH-02E FCC ID: APYHRO00180 Photo(Internal)1/Nov/2012 4 / 5 Model Name:SH-02E FCC ID: APYHRO00180 Photo(Internal)1/Nov/2012 5 / 5

RF Exposure Info

JAPAN QUALITY ASSURANCE ORGANIZATION Page 1 of 61 Technical document No. 23163-1201 JQA File No. : KL80120405 Issue Date : October 18, 2012 TEST REPORT (SAR EVALUATION) Applicant : Sharp Corporation, Communication Systems Group Address : 2-13-1, Iida, Hachihonmatsu, Higashi-Hiroshima City, Hiroshima, 739-0192, Japan Products : Cellular Phone Model No. : SH-02E Serial No. : 004401114215334 FCC ID : APYHRO00180 Test Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Test Results : Passed Date of Test : October 5 ~ 17, 2012 Kousei Shibata Manager Japan Quality Assurance Organization KITA-KANSAI Testing Center SAITO EMC Branch 7-3-10, Saito-asagi, Ibaraki-shi, Osaka 567-0085, Japan ● The measurement values stated in Test Report was made with traceable to National Institute of Advanced Industrial Science and Technology (AIST) of Japan, National Institute of Information and Communications Technology (NICT) of Japan , and Laboratory for EMF and Microwave Electronics at the Swiss Federal Institute of Technology (ETH) in Zürich, Switzerland. ● The applicable standard, testing condition and testing method which were used for the tests are based on the request of the applicant. ● The test results presented in this report relate only to the offered test sample. ● The contents of this test report cannot be used for the purposes, such as advertisement for consumers. ● This test report shall not be reproduced except in full without the written approval of JQA. ● VLAC does not approve, certify or warrant the product by this test report. VLAC-001-2 JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 2 of 61 Technical document No. 23163-1201 TABLE OF CONTENTS Page 1 Description of the Device Under Test (DUT).......................................................................................3 2 Summary of Test Results......................................................................................................................4 3 Test Procedure.......................................................................................................................................5 4 Test Location..........................................................................................................................................5 5 Recognition of Test Laboratory.............................................................................................................5 6 Measurement System Diagram............................................................................................................6 7 System Components..............................................................................................................................7 8 Measurement Process..........................................................................................................................11 9 Measurement Uncertainties...............................................................................................................12 10 Test Arrangement................................................................................................................................14 11 Tissue Verification...............................................................................................................................16 12 System Validation................................................................................................................................18 13 RF Output Power Measurements.......................................................................................................21 14 SAR Measurements.............................................................................................................................28 15 Test Setup Photographs......................................................................................................................52 16 Test Instruments.................................................................................................................................60 17 Appendix...............................................................................................................................................61 JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 3 of 61 Technical document No. 23163-1201 1 Description of the Device Under Test (DUT) 1. Manufacturer : Sharp Corporation, Communication Systems Group 2-13-1, Iida, Hachihonmatsu, Higashi-Hiroshima City, Hiroshima, 739-0192, Japan 2. Products : Cellular Phone 3. Model No. : SH-02E 4. Serial No. : 004401114215334 5. Product Type : Pre-production 6. Date of Manufacture : September, 2012 7. Transmitting Frequency : 826.4 MHz – 846.6 MHz (WCDMA Band V) 824.2 MHz – 848.8 MHz (GSM 850) 1850.2 MHz – 1909.8 MHz (PCS 1900) 2412 MHz – 2462 MHz (WLAN 802.11b/g/n) 5150 MHz – 5250 MHz (WLAN 802.11a/n, W52) 5250 MHz – 5350 MHz (WLAN 802.11a/n, W53) 5500 MHz – 5700 MHz (WLAN 802.11a/n, W56) 2402 MHz – 2480 MHz (Bluetooth) 8. Battery Option : Lithium-ion Battery Pack (2320mAh) 9. Power Rating : 4.0VDC 10. EUT Grounding : None 11. Device Category : Portable Device (§2.1093) 12. Exposure Category : General Population/Uncontrolled Exposure 13. FCC Rule Part(s) : 22(H), 24(E), 15.247, 15.407 14. EUT Authorization : Certification 15. Received Date of DUT : October 3, 2012 JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 4 of 61 Technical document No. 23163-1201 2 Summary of Test Results Applied Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Evaluating Compliance with FCC Guidelines for Human Exposure to Radio- freque…

Text truncated - open the document above for the full version.

RF Exposure Info

Appendix 1 – System Validation Plots JAPAN QUALITY ASSURANCE ORGANIZATION Date/Time: 2012/10/05 9:32:41 Test Laboratory: JAPAN QUALITY ASSURANCE ORGANIZATION System Validation (Head) DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d081 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium: HSL900 Medium parameters used: f = 835 MHz; σ = 0.9 mho/m; ε r = 41.8; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY4 (High Precision Assessment) DASY4 Configuration: zProbe: ET3DV6 - SN1679; ConvF(6.16, 6.16, 6.16); Calibrated: 2012/08/17 zSensor-Surface: 4mm (Mechanical Surface Detection) zElectronics: DAE4 Sn508; Calibrated: 2011/11/14 zPhantom: SAM 1200; Type: QD 000 P40 CA; Serial: 1200 zMeasurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 184 Antenna Input Power 250 mW/Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 2.56 mW/g Antenna Input Power 250 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 55.8 V/m; Power Drift = 0.010 dB Peak SAR (extrapolated) = 3.40 W/kg SAR(1 g) = 2.37 mW/g; SAR(10 g) = 1.56 mW/g Maximum value of SAR (measured) = 2.56 mW/g 0 dB = 2.56mW/g JAPAN QUALITY ASSURANCE ORGANIZATION Date/Time: 2012/10/06 9:33:06 Test Laboratory: JAPAN QUALITY ASSURANCE ORGANIZATION System Validation (Body) DUT: Dipole 835 MHz; Type: D835V2; Serial: 4d081 Communication System: CW; Frequency: 835 MHz;Duty Cycle: 1:1 Medium: MSL900 Medium parameters used: f = 835 MHz; σ = 0.968 mho/m; ε r = 55.4; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY4 (High Precision Assessment) DASY4 Configuration: zProbe: ET3DV6 - SN1679; ConvF(6.21, 6.21, 6.21); Calibrated: 2012/08/17 zSensor-Surface: 4mm (Mechanical Surface Detection) zElectronics: DAE4 Sn508; Calibrated: 2011/11/14 zPhantom: SAM 1200; Type: QD 000 P40 CA; Serial: 1200 zMeasurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 184 Antenna Input Power 250 mW/Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 2.60 mW/g Antenna Input Power 250 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 53.7 V/m; Power Drift = 0.003 dB Peak SAR (extrapolated) = 3.41 W/kg SAR(1 g) = 2.39 mW/g; SAR(10 g) = 1.59 mW/g Maximum value of SAR (measured) = 2.59 mW/g 0 dB = 2.59mW/g JAPAN QUALITY ASSURANCE ORGANIZATION Date/Time: 2012/10/07 9:42:48 Test Laboratory: JAPAN QUALITY ASSURANCE ORGANIZATION System Validation (Head) DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d112 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium: HSL1900 Medium parameters used: f = 1900 MHz; σ = 1.41 mho/m; ε r = 40.3; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY4 (High Precision Assessment) DASY4 Configuration: zProbe: ET3DV6 - SN1679; ConvF(5.06, 5.06, 5.06); Calibrated: 2012/08/17 zSensor-Surface: 4mm (Mechanical Surface Detection) zElectronics: DAE4 Sn508; Calibrated: 2011/11/14 zPhantom: SAM 1200; Type: QD 000 P40 CA; Serial: 1200 zMeasurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 184 Antenna Input Power 250 mW/Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 11.3 mW/g Antenna Input Power 250 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 94.8 V/m; Power Drift = -0.016 dB Peak SAR (extrapolated) = 17.0 W/kg SAR(1 g) = 9.92 mW/g; SAR(10 g) = 5.24 mW/g Maximum value of SAR (measured) = 11.3 mW/g 0 dB = 11.3mW/g JAPAN QUALITY ASSURANCE ORGANIZATION Date/Time: 2012/10/08 9:40:17 Test Laboratory: JAPAN QUALITY ASSURANCE ORGANIZATION System Validation (Body) DUT: Dipole 1900 MHz; Type: D1900V2; Serial: 5d112 Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium: MSL1900 Medium parameters used: f = 1900 MHz; σ = 1.56 mho/m; ε r = 53; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY4 (High Precision Assessment) DASY4 Configuration: zProbe: ET3DV6 - SN1679; ConvF(4.51, 4.51, 4.51); Calibrated: 2012/08/17 zSensor-Surface: 4mm (Mechanical Surface Detection) zElectronics: DAE4 Sn508; Calibrated: 2011/11/14 zPhantom: SAM 1200; Type: QD 000 P40 CA; Serial: 1200 zMeasurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 184 Antenna Input Power 250 mW/Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 11.4 mW/g Antenna Input Power 250 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 93.5 V/m; Power Drift = 0.012 dB Peak SAR (extrapolated) = 16.6 W/kg SAR(1 g) = 10 mW/g; SAR(10 g) = 5.32 mW/g Maximum value of SAR (measured) = 11.4 mW/g 0 dB = 11.4mW/g JAPAN QUALITY ASSURANCE ORGANIZATION Date/Time: 2012/10/09 10:53:22 Test Laboratory: JAPAN QUALITY ASSURANCE ORGANIZATION System Validation (Head) DUT: Dipole 2450 MHz; Type: D2450V2; Serial: 714 Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: HSL2450 Medium parameters used: f = 2450 MHz; σ = 1.81 mho/m; ε r = 38.8; ρ = 1000 kg/m 3 Phantom section: Flat Section Measurement Standard: DASY4 (High Precision Assessment) DASY4 Configuration: zProbe: EX3DV4 - SN3808; ConvF(7.45, 7.45, 7.45); Calibrated: 2012/09/20 zSensor-Surface: 2mm (Mechanical Surface Detection) zElectronics: DAE4 Sn508; Calibrated: 2011/11/14 zPhantom: SAM 1200; Type: QD 000 P40 CA; Serial: 1200 zMeasurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 184 Antenna Input Power 250 mW/Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm Maximum value of SAR (measured) = 20.2 mW/g Antenna Input Power 250 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 108.1 V/m; Power Drift = 0.013 dB Peak SAR (extrapolated) = 28.4 W/kg SAR(1 g) = 13.3 mW/g; SAR(10 g) = 6.12 mW/g Maximum value of SAR (measured) = 20.8 mW/g 0 dB = 20.8mW/g JAPAN QUALITY ASSURANCE ORGANIZATION Date/Time: 2012/10/10 9:…

Text truncated - open the document above for the full version.

RF Exposure Info

JAPAN QUALITY ASSURANCE ORGANIZATION Appendix 3 – Dosimetric E-Field Probe – ET3DV6, S/N: 1679 Calibration Data JAPAN QUALITY ASSURANCE ORGANIZATION Appendix 3 – Dosimetric E-Field Probe – EX3DV4, S/N: 3808 Calibration Data JAPAN QUALITY ASSURANCE ORGANIZATION Appendix 4 – System Validation Dipole – D835V2, S/N: 4d081 Calibration Data JAPAN QUALITY ASSURANCE ORGANIZATION Appendix 4 – System Validation Dipole – D1900V2, S/N: 5d112 Calibration Data JAPAN QUALITY ASSURANCE ORGANIZATION Appendix 4 – System Validation Dipole – D2450V2, S/N: 714 Calibration Data

Test Setup Photos

JQA File No. : KL80120411 Issue Date : October 30, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : CFR 47 FCC Rules and Regulations Part 15 Page 98 of 99 Technical document No. 23199-1201 7.10 Test Setup (Photographs) 7.10.1 AC Powerline Conducted Emission – Front View – – Side View – Photograph present configuration with maximum emission JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120411 Issue Date : October 30, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : CFR 47 FCC Rules and Regulations Part 15 Page 99 of 99 Technical document No. 23199-1201 7.10.2 Radiated Emission – Front View– – Rear View – Photograph present configuration with maximum emission JAPAN QUALITY ASSURANCE ORGANIZATION

Test Setup Photos

JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 52 of 61 Technical document No. 23163-1201 15 Test Setup Photographs 15.1 Left Head – Cheek/Touch Position – – Ear/Tilt Position – JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 53 of 61 Technical document No. 23163-1201 – Cheek/Touch Position w/ touch-pen– JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 54 of 61 Technical document No. 23163-1201 15.2 Right Head – Cheek/Touch Position – – Ear/Tilt Position – JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 55 of 61 Technical document No. 23163-1201 – Cheek/Touch Position w/ touch-pen– JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 56 of 61 Technical document No. 23163-1201 15.3 Body w/ 1.0 cm (hotspot mode) – Top Edge – – Bottom Edge – JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 57 of 61 Technical document No. 23163-1201 – Left Edge – – Right Edge – JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 58 of 61 Technical document No. 23163-1201 – Front Side – – Rear Side – JAPAN QUALITY ASSURANCE ORGANIZATION JQA File No. : KL80120405 Issue Date : October 18, 2012 Model No. : SH-02E FCC ID : APYHRO00180 Standard : FCC/OET Bulletin 65 Supplement C (Edition 01-01) Page 59 of 61 Technical document No. 23163-1201 – Rear Side w/ touch-pen – – Rear Side w/ headset –

Contact Information

Applicant

Taihei Ohtsuka(Division Manager, ESG & Q promotion div.)
[email protected]+81-50-5433-4157Fax: -

Technical Contact

Sharp Electronics CorporationSteve Petruska
[email protected]201-529-9689

Sharp Plaza · Mahwah, New Jersey

Non-Technical Contact

Sharp Electronics CorporationSteve Petruska
[email protected]201-529-9689

Test Firm

Japan Qlty. Assur. Org. Kitakansai Testing CenterHiroyuki Nakamura
[email protected]81-72-640-5270Fax: 81-72-640-5271

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz144.88 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is Conducted. SAR compliance for body-worn accessory operation is based on a separation distance of 1.0 cm between the unit and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly. The highest reported SAR for head, body-worn accessory including product specific (wireless router), and simultaneous transmission use conditions are < 0.1 W/kg, < 0.1 W/kg, < 0.1 W/kg, and 0.69 W/kg respectively. This device also contains functions that are not operational in U.S. territories.

Other Applications from Sharp Corporation

APYHRO00343

Smartphone

Aug 17, 2026

Equipment Class

DTS - Digital Transmission System
APYHRO00342

Smart phone

Jul 29, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
APYHRO00341

Smart phone

May 28, 2026

Equipment Class

DTS - Digital Transmission System
APYHRO00340

BT remote control

Dec 01, 2025

Equipment Class

DTS - Digital Transmission System
APYHRO00339

Smart phone

Sep 17, 2025

Equipment Class

NII - Unlicensed National Information Infrastructure TX