FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Sharp Corporation/
  3. APYHRO00320

APYHRO00320Cellular Phone

Sharp Corporation
Cellular Phone - FCC ID APYHRO00320 - Sharp Corporation
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Sep 27, 2022
Application Purpose
Original Equipment
Date of Application
Sep 22, 2022
Equipment Note
Cellular Phone
Frequency Range
1850.20000000 - 1909.80000000
Company
Sharp Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Package Label Drawing Confidential 本製品は精密機器の為、水濡れ、衝撃にご注意ください。ご使用の際は、お 願いとご注意をよくお読みの上、正しくお使いください。 MADE IN CHINA FCC ID : APYHRO00320 FCC ID FCC ID : APYHRO00320

Users Manual

Introduction Thank you for purchasing “(*****)”. Be sure to read this manual before and during use to ensure proper operation. zThe screens and illustrations in this manual are shown as examples. The actual screens and illustrations may differ. zKey illustrations in this manual differ from the actual design of the keys. zNote that “(*****)” is referred to as “handset” in this manual. zThis manual refers to microSD Card, microSDHC Card or microSDXC Card as “microSD Card” or “microSD”. zReproduction of this manual in part or in whole without prior permission is prohibited. zThe contents of this manual are subject to change without prior notice. 1 Contents/Precautions Basic package (includes warranty) (*****) Cradle Li-Ion Battery Pack Back cover (This picture is not final) 7 Contents/Precautions Precautions (ALWAYS FOLLOW THESE DIRECTIONS) „ Before use, read these “Precautions” carefully and use your handset properly. „ These precautions contain information intended to prevent bodily injur y to the user and to surrounding people, as well as damage to property, and must be observed at all times. „ The following symbols indicate the different degrees of injury or damage that may occur if information provided is not observed and the handset is used improperly. Danger This symbol indicates that “death or serious bodily injury ( *1 ) may directly and immediately result from improper use”. Warning This symbol indicates that “death or serious bodily injury ( *1 ) may result from improper use”. Caution This symbol indicates that “minor injury ( *2 ) and/or property damage ( *3 ) may result from improper use”. *1 Serious bodily injury: This refers to loss of eyesight, bodily injury, burns (high- and low-temperature), electric shock, broken bones, injuries with residual aftereffects from poisoning, etc., and injuries requiring hospital admission for treatment or long-term hospital attendance as an outpatient. *2 Minor injury: This refers to bodily injury, burns (high- and low-temperature), electric shock, etc. that do not require hospital admission for treatment or long-term hospital attendance as an outpatient. *3 Property damage: This refers to extended damage to buildings, furniture, livestock, pets, etc. „ The following symbols indicate specific directions. Indicates a prohibited action. Indicates not to handle the device with wet hands. Indicates not to disassemble the device. Indicates that instructions specified are compulsory (must be followed). Indicates not to use the device near water or get it wet. Indicates that the power cord must be unplugged from the outlet. 8 Contents/Precautions “Precautions” is explained in the following sections. zHandling the handset, adapters, nano UIM card and TV antenna cable (general) ..............................P. 8 z Handling the handset ...............................P.10 z Handling adapters .................................P.14 z Handling nano UIM card ............................P.16 z Handling near electronic medical equipment .............P.16 z Material list ......................................P.17 z Handling the sample (SIM eject tool) ...................P.18 Handling the handset, adapters, nano UIM card and TV antenna cable (general) Danger Do not use, store or leave the equipment in locations subject to high temperatures or accumulation of heat (near a fire or heating unit, in a kotatsu or bedding, under direct sunlight, inside a vehicle on a hot day, etc.). May cause fires, burns, bodily injury, electric shock, etc. Do not place the equipment inside cooking appliances such as microwave ovens and induction cookers or high pressure vessels such as pressure cookers, or near them. May cause fires, burns, bodily injury, electric shock, etc. Do not sprinkle sand, soil or dirt on the equipment or put the equipment directly on it. Also, do not touch the equipment when sand etc. is adhering to your hand. May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness/ dustproofness. ☞ P. 26 “Waterproof/Dustproof” Do not charge the equipment while it is wet with liquids such as water (drinking water, sweat, seawater, pet urine, etc.). May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness. ☞ P. 26 “Waterproof/Dustproof” Do not press the equipment strongly or broken it. Especially when you put and carry it in the pocket, do not let it hit or caught in the object . May cause fires, burns, bodily injury, etc. because of catching fire, exploding, overheating or leaking of the internal battery. ※Take particular care with the followings z Sitting or squatting down while you are putting the equipment in your pocket of trousers or skirt z Letting the equipment caught in the door or vehicular door while you are putting the equipment in your pocket of outerwear z Stepping on the equipment while it is placing on the soft object such as the sof a or bedding, floor 9 Contents/Precautions Do not attempt to disassemble or modify the equipment. May cause fires, burns, bodily injury, electric shock, etc. Do not get the equipment wet with liquids such as water (drinking water, sweat, seawater, pet urine, etc.). May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness. ☞ P. 26 “Waterproof/Dustproof” Do not allow liquids such as water (drinking water, sweat, seawater, pet urine, etc.) to get inside the charger terminal or external connection jack. May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness. ☞ P. 26 “Waterproof/Dustproof” Use only optional parts specified by ●●● . May cause fires, burns, bodily injury, electric shock, etc. Warning Do not subject the equipment to strong force, impacts or vibration such as letting it fall, stepping on it or throwing it. May cause fires, burns, bodily injury, electric shock, etc. Do not allow conductive materials …

Text truncated - open the document above for the full version.

Attestation Statements

1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 Date: September 20, 2022 (TCB) . FCC ID: APYHRO00320 Declaration letter Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Declaration letter for label requirement The label is permanently affixed in the battery compartment, and our device (FCC ID: APYHRO00320) will be sold to market without the battery installed. The users can see the label during the battery installation process. The battery cover can be opened without any special tools. If you have any questions regarding the declaration, please don’t hesitate to contact us. Sincerely yours, ______________________________________ Sharp Corporation Taihei Ohtsuka Deputy General Manager, Quality Promotion Office 1 Takumi-cho, Sakai-ku, Sakai City Osaka Japan 590-8522 Email : [email protected]

Cover Letter(s)

1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 Date: September 7, 2022 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Request for Confidentiality FCC ID: APYHRO00320 To Whom It May Concern, Pursuant to the provision s of Sections 0.457 and 0.459 of Commission’s rules (47CFR § 0.457, § 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. Sch ematic Diagram Block Diagram Part List Operational Description Tune-up Procedure Ab ove mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT § 2.803 and the importation rules in 47 CFR § 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. Ext ernal Photos Intern al Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those in formation will be available for public review once the grant of equipment authorization is issued. B est Regards, __ ____________________ Taihei Ohtsuka [email protected] (TCB) .0

Cover Letter(s)

1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 Date: September 7, 2022 Power of Attorney To whom it may concern, Please be notified that I, Taihei Ohtsuka, have designated Amanda Wu in Bureau Veritas Consumer Products Services (Hong Kong) Limited, Taoyuan branch principally located at No.19, HuaYa 2nd Rd., Wenhua Vil., Guishan Dist., Taoyuan City 33383, Taiwan R.O.C., as the person being responsible for this project and to sign the form 731 and other documentation. Any and all acts carried out by Amanda Wu in Bureau Veritas Consumer Products Services (Hong Kong) Limited, Taoyuan branch on the matters of relating to all processes required in the FCC approval and any communication needed with the national authority, shall have the same legal authority as acts on our own behalf. W e further certify that neither the applicant nor any party to this application, as defined in 47 CFR Ch. 1.2002(b), is subject to a denial to Federal benefits, that include FCC benefits, pursuant to section 5301 of the Anti-Drug Abuse Act of 1998, 21 U.S.C. 862. This authorization is limited to the product of as following: FCC ID: APYHRO00320 If you have any acknowledgement and response, please send it to Bureau Veritas Consumer Products Services (Hong Kong) Limited, Taoyuan branch directly. Should you have any questions or comments regarding this matter, please don’t hesitate to contact me. Sincerely yours, ______________________ Taihei Ohtsuka [email protected] (TCB) .0

External Photos

Reference No.: BGTL-WTW-P22050889_EXT 1 of 4 CONSTRUCTION PHOTOS OF EUT Reference No.: BGTL-WTW-P22050889_EXT 2 of 4 Reference No.: BGTL-WTW-P22050889_EXT 3 of 4 Reference No.: BGTL-WTW-P22050889_EXT 4 of 4

ID Label/Location Info

FCC ID Location FCC ID: APYHRO00320 ○Location Device * The FCC ID is bottom of the battery case. ○Labeling for Purchasing The FCC ID is printed on the package. FCC ID: APYHRO00320 Model Name Manufacturer

Internal Photos

Reference No.: BGTL-WTW-P22050889_INT 1 of 19 CONSTRUCTION PHOTOS OF EUT Reference No.: BGTL-WTW-P22050889_INT 2 of 19 WWAN Antenna WLAN/BT Antenna Reference No.: BGTL-WTW-P22050889_INT 3 of 19 Reference No.: BGTL-WTW-P22050889_INT 4 of 19 Reference No.: BGTL-WTW-P22050889_INT 5 of 19 Reference No.: BGTL-WTW-P22050889_INT 6 of 19 Reference No.: BGTL-WTW-P22050889_INT 7 of 19 Reference No.: BGTL-WTW-P22050889_INT 8 of 19 Reference No.: BGTL-WTW-P22050889_INT 9 of 19 Reference No.: BGTL-WTW-P22050889_INT 10 of 19 Reference No.: BGTL-WTW-P22050889_INT 11 of 19 Reference No.: BGTL-WTW-P22050889_INT 12 of 19 Reference No.: BGTL-WTW-P22050889_INT 13 of 19 Reference No.: BGTL-WTW-P22050889_INT 14 of 19 Reference No.: BGTL-WTW-P22050889_INT 15 of 19 Reference No.: BGTL-WTW-P22050889_INT 16 of 19 Reference No.: BGTL-WTW-P22050889_INT 17 of 19 Reference No.: BGTL-WTW-P22050889_INT 18 of 19 Reference No.: BGTL-WTW-P22050889_INT 19 of 19

RF Exposure Info

SAR Test Report Report Format Version 5.0.0 Page No. : 1 of 29 Report No. : SFBGTL-WTW-P22050889 Issued Date : Sep. 01, 2022 SAR Test Report Report No. : SFBGTL-WTW-P22050889 Applicant : SHARP Corporation Mobile Communication BU Address : 2-13-1 Iida Hachihonmatsu Higashi-hiroshima City, Hiroshima 730-0192, Japan Manufacturer : Sharp Corporation Address : 1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Product : Cellular Phone FCC ID : APYHRO00320 Brand : SHARP FCC Rule Part : CFR §2.1093 Standards : IEC/IEEE 66209-1528:2020 KDB 865664 D01 v01r04, KDB 865664 D02 v01r02, KDB 248227 D01 v02r02, KDB 447498 D01 v06, KDB 648474 D04 v01r03, KDB 941225 D01 v03r01, KDB 941225 D06 v02r01 Sample Received Date : Jul. 21, 2022 Date of Testing : Aug. 06, 2022 ~ Aug. 10, 2022 Lab Address : No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location : No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City, Taiwan CERTIFICATION: The above equipment have been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch–Lin Kou Laboratories, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s SAR characteristics under the conditions specified in this report. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agencies. Prepared By : Vera Huang / Specialist Approved By : Gordon Lin / Manager FCC Accredited No.: TW0003 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. SAR Test Report Report Format Version 5.0.0 Page No. : 2 of 29 Report No. : SFBGTL-WTW-P22050889 Issued Date : Sep. 01, 2022 Table of Contents Release Control Record ............................................................................................................................................................... 3 1. Summary of Maximum SAR Value ....................................................................................................................................... 4 2. Description of Equipment Under Test ................................................................................................................................. 5 3. SAR Measurement System ................................................................................................................................................... 6 3.1 Definition of Specific Absorption Rate (SAR) ............................................................................................................... 6 3.2 SPEAG DASY6 System ............................................................................................................................................... 6 3.2.1 Robot ............................................................................................................................................................... 7 3.2.2 Probes ............................................................................................................................................................. 8 3.2.3 Data Acquisition Electronics (DAE) .................................................................................................................. 8 3.2.4 Phantoms ......................................................................................................................................................... 8 3.2.5 Device Holder .................................................................................................................................................. 9 3.2.6 System Validation Dipoles ............................................................................................................................. 10 3.2.7 Power Source ................................................................................................................................................ 10 3.2.8 Tissue Simulating Liquids .............................................................................................................................. 11 3.3 SAR System Verification .....................................................................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Plots of System Verification Annex A. Plots of System Verification The plots for system verification are shown as follows. Report No.: SFBGTL-WTW-P22050889 Plots of System Verification Test Laboratory: Bureau Veritas ADT SAR/HAC Testing Lab Date: 2022/08/06 S01 System Check_H1900_220806 DUT: Dipole 1900 MHz; Type: D1900V2; SN: 5d036 Communication System: UID 0, CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium: H16T20N1_0806 Medium parameters used: f = 1900 MHz; σ = 1.459 S/m; ε r = 38.633; ρ = 1000 kg/m 3 Ambient Temperature:23.6 °C ; Liquid Temperature:23.2 °C DASY5 Configuration: - Probe: EX3DV4 - SN7537; ConvF(8.24, 8.24, 8.24) @ 1900 MHz; Calibrated: 2022/04/27 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1585; Calibrated: 2022/04/21 - Phantom: Twin SAM Phantom_1986; Type: QD 000 P40 CD; - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 3.20 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 47.74 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 3.82 W/kg SAR(1 g) = 1.97 W/kg; SAR(10 g) = 1.03 W/kg (SAR corrected for target medium) Maximum value of SAR (measured) = 3.22 W/kg Report No.: SFBGTL-WTW-P22050889 Plots of System Verification Test Laboratory: Bureau Veritas ADT SAR/HAC Testing Lab Date: 2022/08/10 S02 System Check_H2450_220810 DUT: Dipole 2450 MHz; Type: D2450V2; SN: 737 Communication System: UID 0, CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: H19T27N1_0810 Medium parameters used: f = 2450 MHz; σ = 1.827 S/m; ε r = 37.475; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C ; Liquid Temperature:23.3 °C DASY5 Configuration: - Probe: EX3DV4 - SN7537; ConvF(7.61, 7.61, 7.61) @ 2450 MHz; Calibrated: 2022/04/27 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1585; Calibrated: 2022/04/21 - Phantom: Twin SAM Phantom_1986; Type: QD 000 P40 CD; - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) Pin=50mW/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 4.41 W/kg Pin=50mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 49.64 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 5.51 W/kg SAR(1 g) = 2.6 W/kg; SAR(10 g) = 1.21 W/kg (SAR corrected for target medium) Maximum value of SAR (measured) = 4.47 W/kg Report No.: SFBGTL-WTW-P22050889 Plots of System Verification Test Laboratory: Bureau Veritas ADT SAR/HAC Testing Lab Date: 2022/08/10 S03 System Check_H2450_220810 DUT: Dipole 2450 MHz; Type: D2450V2; SN: 737 Communication System: UID 0, CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: H19T27N1_0810 Medium parameters used: f = 2450 MHz; σ = 1.827 S/m; ε r = 37.475; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C ; Liquid Temperature:23.3 °C DASY5 Configuration: - Probe: EX3DV4 - SN7537; ConvF(7.61, 7.61, 7.61) @ 2450 MHz; Calibrated: 2022/04/27 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1585; Calibrated: 2022/04/21 - Phantom: Twin SAM Phantom_1986; Type: QD 000 P40 CD; - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) Pin=50mW/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 4.41 W/kg Pin=50mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 49.64 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 5.51 W/kg SAR(1 g) = 2.6 W/kg; SAR(10 g) = 1.21 W/kg (SAR corrected for target medium) Maximum value of SAR (measured) = 4.47 W/kg Report No.: SFBGTL-WTW-P22050889 Plots of System Verification Test Laboratory: Bureau Veritas ADT SAR/HAC Testing Lab Date: 2022/08/06 S04 System Check_H1900_220806 DUT: Dipole 1900 MHz; Type: D1900V2; SN: 5d036 Communication System: UID 0, CW; Frequency: 1900 MHz;Duty Cycle: 1:1 Medium: H16T20N1_0806 Medium parameters used: f = 1900 MHz; σ = 1.459 S/m; ε r = 38.633; ρ = 1000 kg/m 3 Ambient Temperature:23.6 °C ; Liquid Temperature:23.2 °C DASY5 Configuration: - Probe: EX3DV4 - SN7537; ConvF(8.24, 8.24, 8.24) @ 1900 MHz; Calibrated: 2022/04/27 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1585; Calibrated: 2022/04/21 - Phantom: Twin SAM Phantom_1986; Type: QD 000 P40 CD; - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) Pin=50mW/Area Scan (61x61x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm Maximum value of SAR (interpolated) = 3.20 W/kg Pin=50mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 47.74 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 3.82 W/kg SAR(1 g) = 1.97 W/kg; SAR(10 g) = 1.03 W/kg (SAR corrected for target medium) Maximum value of SAR (measured) = 3.22 W/kg Report No.: SFBGTL-WTW-P22050889 Plots of System Verification Test Laboratory: Bureau Veritas ADT SAR/HAC Testing Lab Date: 2022/08/10 S05 System Check_H2450_220810 DUT: Dipole 2450 MHz; Type: D2450V2; SN: 737 Communication System: UID 0, CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: H19T27N1_0810 Medium parameters used: f = 2450 MHz; σ = 1.827 S/m; ε r = 37.475; ρ = 1000 kg/m 3 Ambient Temperature:23.5 °C ; Liquid Temperature:23.3 °C DASY5 Configuration: - Probe: EX3DV4 - SN7537; ConvF(7.61, 7.61, 7.61) @ 2450 MHz; Calibrated: 2022/04/27 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1585; Calibrated: 2022/04/21 - Phantom: Twin SAM Phantom_1986; Type: QD 000 P40 CD; - Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) Pin=50mW/Area Scan (81x81x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm Maximum value of SAR (interpolated) = 4.41 W/kg Pin=50mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 49.64 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 5.51 W/kg SAR(1 g) = 2.6 W/kg; SAR(10 g) = 1.21…

Text truncated - open the document above for the full version.

Test Report

-------------------------------------------------------------------------------------------------------------------------- Antenna Type:Inverted-L Type Antenna Issue Date:July 29, 2022 FCC IDAPYHRO00320 ANTENNA GAIN / PATTERN TEST REPORT 1. Cellular 1.1 Antenna Gain (Open) 1.2 Antenna Pattern (Open) 1.3 Antenna Gain (Close) 1.4 Antenna Pattern (Close) 2. WiFi/BT 2.1 Antenna Gain (Open) 2.2 Antenna Pattern (Open) 2.3 Antenna Gain (Close) 2.4 Antenna Pattern (Close) Table of contents Cellular 1.1 Antenna Gain (Open) FrequencyPlane185018801910 XY1.00.40.6 YZ1.71.11.7 XZ0.90.51.1 XY-2.7-3.6-3.5 YZ-3.1-3.6-3.0 XZ-2.7-3.1-2.5 Unit [dBi] Cellular Figure 1 Peak Gain Avg. Gain Cellular 1.2 Antenna Pattern (Open) Cellular XY Plane YZ Plane XZ Plane XY PlaneEθ 1850 XY Plane Eθ 1880 XY Plane Eθ 1910 XY Plane Eθ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 XY PlaneEφ 1850 XY Plane Eφ 1880 XY Plane Eφ 1910 XY Plane Eφ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 YZPlane Eθ 1850 YZ Plane Eθ 1880 YZ Plane Eθ 1910 YZ Plane Eθ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 YZ Plane Eφ 1850 YZ Plane Eφ 1880 YZ Plane Eφ 1910 YZ Plane Eφ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 XZPlane Eθ 1850 ZX Plane Eθ 1880 ZX Plane Eθ 1910 ZX Plane Eθ 90270 X 0 180 Z -40 -30 -20 -10 0 +5 XZ Plane Eφ 1850 ZX Plane Eφ 1880 ZX Plane Eφ 1910 ZX Plane Eφ 90270 X 0 180 Z -40 -30 -20 -10 0 +5 Cellular 1.3 Antenna Gain (Close) FrequencyPlane185018801910 XY-2.7-3.1-2.4 YZ-2.2-2.3-1.4 XZ-0.1-0.20.5 XY-5.1-5.3-4.4 YZ-5.6-5.5-4.5 XZ-3.8-3.8-3.2 Unit [dBi] Cellular Peak Gain Avg. Gain Cellular 1.4 Antenna Pattern (Close) Cellular XY Plane YZ Plane XZ Plane XY PlaneEθ 1850 XY Plane Eθ 1880 XY Plane Eθ 1910 XY Plane Eθ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 XY PlaneEφ 1850 XY Plane Eφ 1880 XY Plane Eφ 1910 XY Plane Eφ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 YZPlane Eθ 1850 YZ Plane Eθ 1880 YZ Plane Eθ 1910 YZ Plane Eθ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 YZ Plane Eφ 1850 YZ Plane Eφ 1880 YZ Plane Eφ 1910 YZ Plane Eφ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 XZPlane Eθ 1850 ZX Plane Eθ 1880 ZX Plane Eθ 1910 ZX Plane Eθ 90270 X 0 180 Z -40 -30 -20 -10 0 +5 XZ Plane Eφ 1850 ZX Plane Eφ 1880 ZX Plane Eφ 1910 ZX Plane Eφ 90270 X 0 180 Z -40 -30 -20 -10 0 +5 WiFi/BT 2.1 Antenna Gain (Open) FrequencyPlane240024502500 XY-4.6-3.1-3.1 YZ-0.60.50.2 XZ-1.60.0-0.2 XY-6.6-6.0-6.1 YZ-5.5-4.1-4.2 XZ-4.3-3.0-3.0 Unit [dBi] Peak Gain Avg. Gain Figure 2 WiFi/BT ANT WiFi/BT 2.2 Antenna Pattern (Open) WiFi ANT (2400-2500MHz) XY Plane YZ Plane XZ Plane XY PlaneEθ 2400 XY Plane Eθ 2450 XY Plane Eθ 2500 XY Plane Eθ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 XY PlaneEφ 2400 XY Plane Eφ 2450 XY Plane Eφ 2500 XY Plane Eφ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 YZPlane Eθ 2400 YZ Plane Eθ 2450 YZ Plane Eθ 2500 YZ Plane Eθ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 YZ Plane Eφ 2400 YZ Plane Eφ 2450 YZ Plane Eφ 2500 YZ Plane Eφ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 XZPlane Eθ 2400 ZX Plane Eθ 2450 ZX Plane Eθ 2500 ZX Plane Eθ 90270 X 0 180 Z -40 -30 -20 -10 0 +5 XZ Plane Eφ 2400 ZX Plane Eφ 2450 ZX Plane Eφ 2500 ZX Plane Eφ 90270 X 0 180 Z -40 -30 -20 -10 0 +5 WiFi/BT 2.3 Antenna Gain (Close) FrequencyPlane240024502500 XY-3.0-2.0-2.3 YZ-2.9-0.8-0.9 XZ-2.3-0.6-0.6 XY-6.0-5.0-5.1 YZ-7.7-6.0-6.1 XZ-5.1-4.4-4.4 Unit [dBi] WiFi/BT ANT Peak Gain Avg. Gain WiFi/BT 2.4 Antenna Pattern (Close) WiFi ANT (2400-2500MHz) XY Plane YZ Plane XZ Plane XY PlaneEθ 2400 XY Plane Eθ 2450 XY Plane Eθ 2500 XY Plane Eθ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 XY PlaneEφ 2400 XY Plane Eφ 2450 XY Plane Eφ 2500 XY Plane Eφ 27090 Y 0 180 X -40 -30 -20 -10 0 +5 YZPlane Eθ 2400 YZ Plane Eθ 2450 YZ Plane Eθ 2500 YZ Plane Eθ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 YZ Plane Eφ 2400 YZ Plane Eφ 2450 YZ Plane Eφ 2500 YZ Plane Eφ 90270 Y 0 180 Z -40 -30 -20 -10 0 +5 XZPlane Eθ 2400 ZX Plane Eθ 2450 ZX Plane Eθ 2500 ZX Plane Eθ 90270 X 0 180 Z -40 -30 -20 -10 0 +5 XZ Plane Eφ 2400 ZX Plane Eφ 2450 ZX Plane Eφ 2500 ZX Plane Eφ 90270 X 0 180 Z -40 -30 -20 -10 0 +5

Test Report

Report No.: RFBGTL-WTW-P22050889-3 R1 Page No. 1 / 35 Report Format Version: 6.1.1 Cancels and replaces the report no. : RFBGTL-WTW-P22050889-3 dated on Sep. 06, 2022 FCC Test Report (PART 24) Report No.: RFBGTL-WTW-P22050889-3 R1 FCC ID: APYHRO00320 Received Date: 2022/7/21 Test Date: 2022/8/8 ~ 2022/8/19 Issued Date: 2022/9/8 Applicant: SHARP Corporation Mobile Communication BU Address: 2-13-1 Iida Hachihonmatsu Higashi-hiroshima City, Hiroshima 730-0192, Japan Manufacturer: Sharp Corporation Address: 1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location (1): No.19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City 33383, Taiwan Test Location (2): B2F., No.215, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan FCC Registration / Designation Number: 788550 / TW0003 427177 / TW0011 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission ca…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Taihei Ohtsuka(Division Manager, ESG & Q promotion div.)
[email protected]+81-50-5433-4157Fax: -

Test Firm

Bureau Veritas CPS(H.K.) Ltd., Taoyuan BranchLiu Ken
[email protected]+886-3-2600609Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz1.442 W244KGXW0.002 ppm
Confidentiality
Long Term
Grant Notes
Output Power is EIRP and ERP for above and below 1 GHz, respectively. SAR compliance for body-worn operating configurations is limited to belt-clips and holsters that have no metallic components in the assembly and cause the device to operate with the minimum separation distance of 1.0 cm, as described in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router) and simultaneous transmission exposure conditions are 0.37 W/kg, 0.65 W/kg, 0.65 W/kg and 0.80 W/kg, respectively. This device contains functions that are not operational in U.S. Territories; this filing is applicable only for U.S. operations.

Other Applications from Sharp Corporation

APYHRO00344

Smart phone

Sep 10, 2026

Equipment Class

NII - Unlicensed National Information Infrastructure TX
APYHRO00343

Smartphone

Aug 17, 2026

Equipment Class

DTS - Digital Transmission System
APYHRO00342

Smart phone

Jul 29, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
APYHRO00341

Smart phone

May 28, 2026

Equipment Class

DTS - Digital Transmission System
APYHRO00340

BT remote control

Dec 01, 2025

Equipment Class

DTS - Digital Transmission System