Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
zThe screens and illustrations in this manual are shown as examples. The actual screens and illustrations may differ. zNote that “(*****)” is referred to as “handset” in this manual. zThis manual refers to microSD Card, microSDHC Card or microSDXC Card as “microSD Card” or “microSD”. zReproduction of this manual in part or in whole without prior permission is prohibited. zThe contents of this manual are subject to change without prior notice. Introduction Thank you for purchasing “(*****)” . Be sure to read this manual before and during use to ensure proper operation. 1 Contents/Precautions Basic package “(*****)” (This drawing is not final) Quick Start guide (in Japanese only) •Purchase a specified charger (sold separately). The following items are not included in the package. •Earphone •USB Type-C cable •microSD memory card •AC adapter 7 Contents/Precautions Precautions (ALWAYS FOLLOW THESE DIRECTIONS) Before use, read these “Precautions” carefully and use your handset properly. These precautions contain information intended to prevent bodily injury to the user and to surrounding people, as well as damage to proper ty, and must be observed at all times. The following symbols indicate the different degrees of injury or damage that may occur if information provided is not observed and the handset is used improperly. Danger This symbol indicates that “death or serious bodily injury ( *1 ) may directly and immediately result from improper use”. Warning This symbol indicates that “death or serious bodily injury ( *1 ) may result from improper use”. Caution This symbol indicates that “minor injury ( *2 ) and/or property damage ( *3 ) may result from improper use”. *1 Serious bodily injury: This refers to loss of eyesight, bodily injury, burns (high- and low-temperature), electric shock, broken bones, injuries with residual aftereffects from poisoning, etc., and injuries requiring hospital admission for treatment or long-term hospital attendance as an outpatient. *2 Minor injury: This refers to bodily injury, burns (high- and low-temperature), electric shock, etc. that do not require hospital admission for treatment or long-term hospital attendance as an outpatient. *3 Property damage: This refers to extended damage to buildings, furniture, livestock, pets, etc. The following symbols indicate specific directions. Indicates a prohibited action. Indicates not to handle the device with wet hands. Indicates not to disassemble the device. Indicates that instructions specified are compulsory (must be followed). Indicates not to use the device near water or get it wet. Indicates that the power cord must be unplugged from the outlet. 8 Contents/Precautions “Precautions” is explained in the following sections. zHandling the handset, adapters, nano UIM card and TV antenna cable (general) ..............................P. 8 z Handling the handset ...............................P.10 z Handling adapters .................................P.14 z Handling nano UIM card ............................P.16 z Handling near electronic medical equipment .............P.16 z Material list ......................................P.17 z Handling the sample (SIM eject tool) ...................P.18 Handling the handset, adapters, nano UIM card and TV antenna cable (general) Danger Do not use, store or leave the equipment in locations subject to high temperatures or accumulation of heat (near a fire or heating unit, in a kotatsu or bedding, under direct sunlight, inside a vehicle on a hot day, etc.). May cause fires, burns, bodily injury, electric shock, etc. Do not place the equipment inside cooking appliances such as microwave ovens and induction cookers or high pressure vessels such as pressure cookers, or near them. May cause fires, burns, bodily injury, electric shock, etc. Do not sprinkle sand, soil or dirt on the equipment or put the equipment directly on it. Also, do not touch the equipment when sand etc. is adhering to your hand. May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness/ dustproofness. ☞ P. 26 “Waterproof/Dustproof” Do not charge the equipment while it is wet with liquids such as water (drinking water, sweat, seawater, pet urine, etc.). May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness. ☞ P. 26 “Waterproof/Dustproof” Do not press the equipment strongly or broken it. Especially when you put and carry it in the pocket, do not let it hit or caught in the object . May cause fires, burns, bodily injury, etc. because of catching fire, exploding, overheating or leaking of the internal battery. ※Take particular care with the followings z Sitting or squatting down while you are putting the equipment in your pocket of trousers or skirt z Letting the equipment caught in the door or vehicular door while you are putting the equipment in your pocket of outerwear z Stepping on the equipment while it is placing on the soft object such as the sofa or bedding, floor 9 Contents/Precautions Do not attempt to disassemble or modify the equipment. May cause fires, burns, bodily injury, electric shock, etc. Do not get the equipment wet with liquids such as water (drinking water, sweat, seawater, pet urine, etc.). May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness. ☞ P. 26 “Waterproof/Dustproof” Do not allow liquids such as water (drinking water, sweat, seawater, pet urine, etc.) to get inside the charger terminal or external connection jack. May cause fires, burns, bodily injury, electric shock, etc. Refer to the following for details on waterproofness. ☞ P. 26 “Waterproof/Dustproof” Use only optional parts specified by ●●● . May cause fires, burns, bodily injury, electric shock, etc. Warning Do not subject the equipment to strong force, impacts or vibration such as letting it fall, stepping on it or throwing it. May cause fires, burns, bod…
Text truncated - open the document above for the full version.
1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 (TCB) To: Federal Communications Commission Date: 2023/04/27 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Section 2.911(d)(5)(i) and Section 2.911(d)(5)(ii) (KDB 986446 D01 Covered Equipment) Section 2.911(d)(5)(i) SHARP CORPORATION (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Section 2.911(d)(5)(ii) SHARP CORPORATION (“the applicant”) certifies that, as of the date of the filing of the application, the applicant not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Type of Equipment subject to FCC Certification: DSS/DTS/NII/PCE/JBP/DXX/UWB/6XD/DCD FCC ID: APYHRO00325 If you have any questions, please feel free to contact me ___________________________ Taihei Ohtsuka [email protected]
1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 To: Federal Communications Commission Date: 2023/04/27 7435 Oakland Mills Road Columbia, MD 21046 USA Attestation Certification designating a U.S. Agent for Service of Process Section 2.911(d)(7) (KDB 986446 D01 Covered Equipment) SHARP CORPORATION (“the applicant”) as required by section 2.911(d)(7), designate below contact located in the United States for purposes of acting as the applicant’s agent for service of process. The applicant also acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Type of Equipment subject to FCC Certification: DSS/DTS/NII/JBP/PCE/DXX/UWB/6XD/DCD FCC ID: APYHRO00325 Sincerely yours, Applicant/Grantee _________________ (Signature) SHARP CORPORATION Taihei Ohtsuka [email protected] (TCB) US Agent ___________________ (Signature) America Compliance Consulting LLC dba iCertifi Address: Bend, Oregon 97702, United States FRN :0033399411 Contact person / Title : Paul A Preston / CEO Email: [email protected]
1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 Date: April 27, 2023 Power of Attorney To whom it may concern, Please be notified that I, Taihei Ohtsuka, have designated LiuZexin in SRTC principally located at 15 th Building, No.30 Shixing Street, Shijingshan District, Beijing, China as the person being responsible for this project and to sign the form 731 and other documentation. Any and all acts carried out by LiuZexin in SRTC on the matters of relating to all processes required in the FCC approval and any communication needed with the national authority, shall have the same legal authority as acts on our own behalf. This authorization is limited to the product of as following: FCC ID: APYHRO00325 If you have any acknowledgement and response, please send it to SRTC directly. Should you have any questions or comments regarding this matter, please don’t hesitate to contact me. Sincerely yours, ______________________ Taihei Ohtsuka [email protected] (TCB) .0
1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 Date: April 27, 2023 Federal Communications Commission Office of Engineering and Technology Laboratory Division 7435 Oakland Mills Rd Columbia MD 21046-1609 Subject: Request for Confidentiality FCC ID: APYHRO00325 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR § 0.457, § 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. ⚫ Schematic Diagram ⚫ Block Diagram ⚫ Part List ⚫ Operational Description ⚫ Tune-up Procedure Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFT § 2.803 and the importation rules in 47 CFR § 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. ⚫ External Photos ⚫ Internal Photos ⚫ Test Setup Photos ⚫ User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, ______________________ Taihei Ohtsuka [email protected] (TCB) .0
1 Takumi-cho, Sakai-ku, Sakai City, Osaka 590-8522, Japan Tel : 81-50-5433-4157 (TCB) .0 WLAN Channel 12 & 13 Declaration Letter To whom it may concern: We have declared below featured for FCC equipment authorization in regard to 802.11b/g/n channel 12 & 13 operating capability for FCC ID: APYHRO00325. Please check Product hardware does not have the capability to operate on channel 12 & 13 Product hardware has the capability to operate on channel 12 & 13. However , these 2 channels will be disabled via software and user will not able to enable these 2 channels Product hardware has the capability to operate on channel 12 & 13. And meeting KDB 594280 D01 requirement. Pls explain detail here. The control of the WLAN function equipped in this device is not dependent on the information from the Access Point but is performed by "MCC" and "MNC" directly acquired from the network carrier and this operation is according to clause IV.B.1 (b) - (2) of the KDB594280 D01. Refer to a separate submitted report for actual operation of this device. 12-2_WLAN_Software configuration information for restriction_APYHRO00xxx.pdf Others Pls explain detail here. Company Name: Sharp Corporation Address : 1 Takumi-cho, Sakai-ku, Sakai City Osaka Japan 590-8522 Name / Title : Taihei Ohtsuka / Deputy Division Manager, ESG and Quality Promotion Unit, CEO Office Signature : ____________________________________ Email : [email protected] Date : April 27, 2023
External Photos FCC ID: APYHRO00325 1/ 5 External Photos FCC ID: APYHRO00325 2/ 5 External Photos FCC ID: APYHRO00325 3/ 5 External Photos FCC ID: APYHRO00325 4/ 5 External Photos FCC ID: APYHRO00325 5/ 5
FCC ID Location FCC ID : APYHRO00325 ○e-label (on the display) ○Access to the information on the e-label Users are able to access the information in no more than three steps in the device Settings menu. STEP1: Click on "About phone" STEP2: Click on "Regulatory labels" ○Instruction of e-label on the user manual * Users are provided specific instructions on how to access the information. FCC Notice (FCC ID Location) ○Labeling for Purchasing The FCC ID is printed on the package. 〇Note * The information is stored on the device, no special accessories or supplemental plug-ins (e.g., SIM/USIM card) are required to access the information. * Users are provided specific instructions on how to access the information. The user cannot modify the e-label information. FCC ID: APYHRO00325 Model Name Manufacturer
Internal Photos FCC ID: APYHRO00325 1/ 7 Internal Photos FCC ID: APYHRO00325 2/ 7 Internal Photos FCC ID: APYHRO00325 3/ 7 Internal Photos FCC ID: APYHRO00325 4/ 7 Internal Photos FCC ID: APYHRO00325 5/ 7 Internal Photos FCC ID: APYHRO00325 6/ 7 Internal Photos FCC ID: APYHRO00325 7/ 7
No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 1 of 39 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 System check 750MHz(2023.03.29) Communication System: UID 0, CW (0); Frequency: 750 MHz; Duty Cycle: 1:1 Medium parameters used: f = 750 MHz; σ = 0.87 S/m; ε r = 42.53; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3708; ConvF(9.75, 9.75, 9.75) @ 750 MHz; Calibrated: 2022/10/28 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn546; Calibrated: 2022/9/15 Phantom: Twin-SAM 1559; Type: QD 000 P40 CD; Serial: xxxx Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) 750/Dipole 750MHz/Area Scan (5x15x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.83 W/kg 750/Dipole 750MHz/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 58.50 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 3.24 W/kg SAR(1 g) = 2.06 W/kg; SAR(10 g) = 1.46 W/kg Maximum value of SAR (measured) = 2.85 W/kg SRTC performed system check by using 250mw at antenna port No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 2 of 39 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 System check 835MHz(2023.04.03) Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1 Medium parameters used (interpolated): f = 835 MHz; σ = 0.91 S/m; ε r = 39.65; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3708; ConvF(9.22, 9.22, 9.22) @ 835 MHz; Calibrated: 2022/10/28 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn546; Calibrated: 2022/9/15 Phantom: Twin-SAM 1559; Type: QD 000 P40 CD; Serial: xxxx Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) D835/Dipole 835MHz/Area Scan (5x14x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 2.71 W/kg D835/Dipole 835MHz/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 56.70 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 3.50 W/kg SAR(1 g) = 2.45 W/kg; SAR(10 g) = 1.54 W/kg Maximum value of SAR (measured) = 3.04 W/kg SRTC performed system check by using 250mw at antenna port No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 3 of 39 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 System check 900MHz(2023.04.04) Communication System: UID 0, CW (0); Frequency: 900 MHz; Duty Cycle: 1:1 Medium parameters used: f = 900 MHz; σ = 0.93 S/m; ε r = 40.03; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3708; ConvF(9.22, 9.22, 9.22) @ 900 MHz; Calibrated: 2022/10/28 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn546; Calibrated: 2022/9/15 Phantom: Twin-SAM 1559; Type: QD 000 P40 CD; Serial: xxxx Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) D900/Dipole 900MHz/Area Scan (5x13x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 3.85 W/kg D900/Dipole 900MHz/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 66.17 V/m; Power Drift = 0.00 dB Peak SAR (extrapolated) = 4.74 W/kg SAR(1 g) = 2.79 W/kg; SAR(10 g) = 1.69W/kg Maximum value of SAR (measured) = 3.99 W/kg SRTC performed system check by using 250mw at antenna port No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 4 of 39 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 System check 1800MHz(2023.04.07) Communication System: UID 0, CW (0); Frequency: 1800 MHz; Duty Cycle: 1:1 Medium parameters used: f = 1800 MHz; σ = 1.38 S/m; ε r = 39.08; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3708; ConvF(8.13, 8.13, 8.13) @ 1800 MHz; Calibrated: 2022/10/28 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn546; Calibrated: 2022/9/15 Phantom: Twin-SAM 1559; Type: QD 000 P40 CD; Serial: xxxx Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) D1800/Dipole 1800MHz/Area Scan (5x9x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 15.3 W/kg D1800/Dipole 1800MHz/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 107.8 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 18.7 W/kg SAR(1 g) = 10.07 W/kg; SAR(10 g) = 5.15 W/kg Maximum value of SAR (measured) = 15.6 W/kg SRTC performed system check by using 250mw at antenna port No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 5 of 39 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 System check 2000MHz(2023.04.10) Communication System: UID 0, CW (0); Frequency: 2000 MHz; Duty Cycle: 1:1 Medium parameters used: f = 2000 MHz; σ = 1.44 S/m; ε r = 38.04; ρ = 1000 kg/m 3 Phantom section: Flat Section DASY5 Configuration: Probe: EX3DV4 - SN3708; ConvF(8.0, 8.0, 8.0) @ 2000 MHz; Calibrated: 2022/10/28 Sensor-Surface: 1.4mm (Mechanical Surface Detection) Electronics: DAE4 Sn546; Calibrated: 2022/9/15 Phantom: Twin-SAM 1559; Type: QD 000 P40 CD; Serial: xxxx Measurement SW: DASY52, Version 52.10 (4); SEMCAD X Version 14.6.14 (7483) D2000/Dipole 2000MHz/Area Scan (5x9x1): Measurement grid: dx=15mm, dy=15mm Maximum value of SAR (measured) = 15.2 W/kg D2000/Dipole 2000MHz/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 107.6 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 18.9 W/kg SAR(1 g) = 10.09 W/kg; SAR(10 g) = 5.30 W/kg Maximum value of SAR (measured) = 15.5 W/kg SRTC performed system check by using 250mw at antenna port No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 6 of 39 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 System check 2450MHz(2023.04.15) Commu…
Text truncated - open the document above for the full version.
Certificate #5505.02 TEST REPORT FOR SAR TESTING Report No.: SRTC2023-9004(F)-23032901(H) Product Name: Smart Phone Applicant: Sharp Corporation FCC ID: APYHRO00325 Reference Specification Part 2.1093 IEEE Std 1528 KDB Procedures The State Radio_monitoring_center Testing Center (SRTC) 15th Building, No.30 Shixing Street, ShijingshanDistrict, Beijing,P.R.China Tel: 86-10-57996183 Fax: 86-10-5799638 No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 2 of 133 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 1 GENERAL INFORMATION ............................................................................................................................................ 3 1.1 Notes of the test report .................................................................................................................................................. 3 1.2 Information about the testing laboratory ...................................................................................................................... 3 1.3 Applicant’s details ........................................................................................................................................................... 3 1.4 Manufacturer’s details .................................................................................................................................................... 3 2 DESCRIPTION OF THE EQUIPMENT UNDER TEST ................................................................................................. 4 2.1 DUT information .............................................................................................................................................................. 4 2.2 Exposure conditions ....................................................................................................................................................... 6 2.3 Other information ............................................................................................................................................................ 6 3 SPECIFICATION ............................................................................................................................................................. 7 4 TEST CONDITIONS ........................................................................................................................................................ 8 4.1 Test signal, frequencies and output power ................................................................................................................. 8 4.2 SAR measurement set-up ............................................................................................................................................. 8 4.3 Phantoms ......................................................................................................................................................................... 8 4.4 Tissue stimulants ............................................................................................................................................................ 9 4.5 Device holder .................................................................................................................................................................. 9 4.6 Scan procedure ............................................................................................................................................................. 10 4.7 SAR averaging methods .............................................................................................................................................. 10 5 RESULT SUMMARY ..................................................................................................................................................... 11 6 TEST RESULTS ............................................................................................................................................................ 13 6.1 Scenario ......................................................................................................................................................................... 13 6.2 Average conducted power with Tune up tolerance ................................................................................................. 14 7 SAR RESULTS .............................................................................................................................................................. 90 7.1 T-issue and System Check ......................................................................................................................................... 90 7.2 SAR Test result ............................................................................................................................................................. 92 7.3 Simultaneous Transmission SAR Analysis ............................................................................................................. 126 8 MEASUREMENT UNCERTAINTY ............................................................................................................................. 128 9 TEST EQUIPMENTS ................................................................................................................................................... 129 No. SRTC2023-9004(F)-23032901(H) The State Radio_monitoring_center Testing Center (SRTC) Page number: 3 of 133 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 1 GENERAL INFORMATION 1.1 Notes of the test report The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written permission of The State Radio_monitoring_center Testing Center (SRTC).The certification and accreditation identifiers used in this report shall not be applicable to the tested or calibrated samples thereof. The manufacturer shall not mark the tested samples or …
Text truncated - open the document above for the full version.
No.:SRTC2023-9004(F) -23032901(S) The State Radio_monitoring_center Testing Center (SRTC) Page number: 1 of 2 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 ANNEX A – TEST PLOTS Plots of System Check Measurement Report for Device, FRONT, Validation band, CW, Channel 10000 (10000.0 MHz) Device Under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 100.0 x 100.0 x 100.0 Dipole Exposure Conditions Phantom Section Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor 5G FRONT, 10.00 Validation band CW, 0-- 10000.0, 10000 1.0 Hardware Setup Phantom Medium Probe, Calibration Date DAE, Calibration Date mmWave - 1087 Air - EUmmWV4 - SN9603_F1-55GHz, 2022-10-25 DAE4 Sn546, 2022-9-15 Scans Setup Measurement Results Scan Type 5G Scan Grid Extents [mm] 120.0 x 120.0 Grid Steps [lambda] 0.15 x 0.15 Sensor Surface [mm] 10.0 MAIA N/A Scan Type 5G Scan Date 2023-04-13, 13:53 Avg. Area [cm 2 ] 1.00 psPDn+ [W/m 2 ] 134 psPDtot+ [W/m 2 ] 136 psPDmod+ [W/m 2 ] 137 E max [V/m] 229 Power Drift [dB] -0.01 No.:SRTC2023-9004(F) -23032901(S) The State Radio_monitoring_center Testing Center (SRTC) Page number: 2 of 2 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 Plots of Test Measurement Report for Device, BACK, U-NII-5, IEEE 802.11a, Channel 45 (6175.0 MHz) Device under Test Properties Model, Manufacturer Dimensions [mm] IMEI DUT Type Device, 161.0 x 76.0 x 8.0 Phone Exposure Conditions Phantom Section Position, Test Distance [mm] Band Group, UID Frequency [MHz], Channel Number Conversion Factor 5G BACK, 2.00 U-NII-5 WLAN, 10671-AAC 6175.0, 45 1.0 Hardware Setup Phantom Medium Probe, Calibration Date DAE, Calibration Date mmWave - 1087 Air - EUmmWV4 - SN9603_F1-55GHz, 2022-10-25 DAE4 Sn546, 2022-9-15 Scans Setup Measurement Results Scan Type 5G Scan Grid Extents [mm] 25.0 x 25.0 Grid Steps [lambda] 0.0625 x 0.0625 Sensor Surface [mm] 2.0 MAIA Y Scan Type 5G Scan Date 2023-04-13 Avg. Area [cm 2 ] 4.00 psPDn+ [W/m 2 ] 2.11 psPDtot+ [W/m 2 ] 2.49 psPDmod+ [W/m 2 ] 2.81 E max [V/m] 46
Certificate #5505.02 TEST REPORT FOR PD TESTING Report No.: SRTC2023-9004(F)-23032901(S) Product Name: Smart Phone Applicant: Sharp Corporation FCC ID: APYHRO00325 Reference Specification KDB 987594 Part 2.1093 IEC/IEEE 63170 IEC/IEEE 63195-1 IEC 62479 DASY6-mmWave SYSTEM HANDBOOK DASY6 Application Note_ Interim Procedures for SAR & PD at 6 – 10 GHz The State Radio_monitoring_center Testing Center (SRTC) 15th Building, No.30 Shixing Street, ShijingshanDistrict, Beijing,P.R.China Tel: 86-10-57996183 Fax: 86-10-5799638 No. SRTC2023-9004(F)-23032901(S) The State Radio_monitoring_center Testing Center (SRTC) Page number: 2 of 32 Tel: 86-10-57996183 Fax: 86-10-57996388 V3.0.0 1 GENERAL INFORMATION ................................................................................................................................................. 3 1.1 Notes of the test report ...................................................................................................................................... 3 1.2 Information about the testing laboratory ........................................................................................................... 3 1.3 Applicant’s details ............................................................................................................................................. 3 1.4 Manufacturer’s details ....................................................................................................................................... 3 2 DESCRIPTION OF THE EQUIPMENT UNDER TEST ............................................................................................................... 4 2.1 DUT information ................................................................................................................................................ 4 2.2 Exposure Conditions ......................................................................................................................................... 4 2.3 Other information .............................…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 44.00 mW |
Smartphone
Equipment Class
DTS - Digital Transmission SystemSmart phone
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterSmart phone
Equipment Class
DTS - Digital Transmission SystemBT remote control
Equipment Class
DTS - Digital Transmission SystemSmart phone
Equipment Class
NII - Unlicensed National Information Infrastructure TX