Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Before using Apple Watch, review the Apple Watch User Guide at support.apple.com/en-ca/guide/watch. You can also use Apple Books to download the guide (where available). Retain documentation for future reference. Safety and Handling See âSafety and handlingâ in the Apple Watch User Guide. Apple Watch, its operating systems, and the health sensors are not medical devices. Exposure to Radio Frequency For radio frequency exposure information for Apple Watch, open the Apple Watch app on iPhone and tap My Watch, then go to General > About > Legal > RF Exposure. Or go to apple.com/ca/legal/rfexposure. Battery and Charging The lithium-ion battery in Apple Watch should be serviced or recycled by Apple or an authorized service provider. You may receive a replacement Apple Watch when ordering battery service. Batteries must be recycled or disposed of separately from household waste. For information about battery service and recycling, go to apple.com/ca/batteries/ service-and-recycling. For information about charging, see âImportant safety informationâ in the Apple Watch User Guide. Medical Device Interference Apple Watch, some of the bands, the Apple Watch Magnetic Charging Cable, and the Apple Watch Magnetic Charging Dock contain magnets that may interfere with medical devices. See âImportant safety informationâ in the Apple Watch User Guide. Avoiding Hearing Damage To prevent possible hearing damage, do not listen at high volume levels for long periods. More information about sound and hearing is available online at apple.com/ca/sound and in âImportant safety informationâ in the Apple Watch User Guide. Apple One-Year Limited Warranty Summary Apple warrants the included hardware product and accessories against defects in materials and workmanship for one year from the date of original retail purchase. Apple does not warrant against normal wear and tear, nor damage caused by accident or abuse. To obtain service, call Apple or visit an Apple Store or an Apple Authorized Service Providerâavailable service options are dependent on the country in which service is requested and may be restricted to the original country of sale. Call charges and international shipping charges may apply, depending on the location. Subject to the full terms and detailed information on obtaining service available at apple.com/ca/legal/warranty and support.apple.com/en-ca, if you submit a valid claim under this warranty, Apple will either repair, replace, or refund your Apple Watch at its own discretion. Warranty benefits are in addition to rights provided under local consumer laws. You may be required to furnish proof of purchase details when making a claim under this warranty. For Australian Consumers: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Apple Pty Ltd, PO Box A2629, Sydney South, NSW 1235. Tel: 133-622. Regulatory Regulatory certification information is available on-device. Go to Settings > General > Regulatory. Additional regulatory information is in âSafety and handlingâ in the Apple Watch User Guide. FCC and ISED Canada Compliance for Apple Watch and Apple Watch Magnetic Charging Cable This device complies with part 15 of the FCC Rules and ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. EU Compliance Apple Inc. hereby declares that this wireless device is in compliance with Directive 2014/53/EU. A copy of the EU Declaration of Conformity is available at apple.com/euro/compliance. The CE marking on Apple Watch is located in the band attachment slot. Appleâs EU representative is Apple Distribution International Ltd., Hollyhill Industrial Estate, Cork, Ireland. European UnionâDisposal Information The symbol above means that according to local laws and regulations your product and/or its battery shall be disposed of separately from household waste. When this product reaches its end of life, take it to a collection point designated by local authorities. The separate collection and recycling of your product and/or its battery at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. Avant dâutiliser lâApple Watch, veuillez lire le Guide de lâutilisateur de lâApple Watch sur support.apple.com/fr-ca/ guide/watch. Vous pouvez Ă©galement utiliser Apple Books pour tĂ©lĂ©charger le guide (lorsque disponible). Conservez cette documentation pour toute rĂ©fĂ©rence ultĂ©rieure. SĂ©curitĂ© et manipulation Reportez-vous Ă la section « SĂ©curitĂ© et manipulation » du Guide de lâutilisateur de lâApple Watch. LâApple Watch, ses systĂšmes dâexploitation et les capteurs de santĂ© ne sont pas des appareils mĂ©dicaux. Exposition aux radiofrĂ©quences Pour vous renseigner sur lâexposition aux radiofrĂ©quences Ă©mises par lâApple Watch, ouvrez lâapp Watch sur lâiPhone et touchez Ma montre, puis accĂ©dez Ă GĂ©nĂ©ral > Informations > Mentions lĂ©gales > Exposition aux RF. Vous pouvez aussi vous rendre sur apple.com/ca/fr/legal/rfexposure. Batterie et chargement La maintenance ou le recyclage de la batterie lithium-ion de lâApple Watch doit ĂȘtre effectuĂ© par Apple ou un centre de services agréé. Si vous faites appel Ă un service dâassistance pour la batterie, il se peut que votre Apple Watch soit remplacĂ©e. Les batteries doivent ĂȘtre recyclĂ©es ou mises au rebut sĂ©parĂ©ment des ordures mĂ©nagĂšres. Pour plus dâinformations sur lâentretien et le recyclage des batteries, consultez la page apple.com/ca/fr/batteries/serviceâŠ
Text truncated - open the document above for the full version.
Electronic Label The regulatory information is programmed in a secured manner. Users or third parties cannot modify the regulatory information page on the device. Instructions to user Regulatory certification information is available on-device. Go to Settings > General > Regulatory. Packaging Label FCC ID: BCG-A2356 IC: 579C-A2356 One Apple Park Way, Cupertino, CA 95014 USA
FCC ID: BCG-A2356 SAR EVALUATION REPORT Approved by: Quality Manager Document S/N: Test Dates: DUT Type: Page 1 of 58 1C2004270026-01-R1.BCG 06/29/2020 â 08/26/2020 Watch © 2020 PCTEST REV 21.4 M 09/11/2019 © 2020 PCTEST All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from PCTEST. If you have any questions about this international copyright or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. Applicant Name: Date of Testing: Apple, Inc. 06/29/2020 â 08/26/2020 One Apple Park Way Test Site/Location: Cupertino, CA 95014 USA PCTEST Lab, Morgan Hill, CA, USA Document Serial No.: 1C2004270026-01-R1.BCG F C C ID: BCG-A2356 A P P L I C A N T : APPLE, I N C. DUT Type: Watch Application Type: Certification FCC Rule Part(s): CFR §2.1093 Model: A2356 Note: This revised Test Report (S/N: 1C2004270026-01-R1.BCG) supersedes and replaces the previously issued test report on the same subject device for the same type of testing as indicated. Please discard or destroy the previously issued test report(s) and dispose of it accordingly. This watch has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE C95.1-1992 and has been tested in accordance with the measurement procedures specified in Section 1.8 of this report; for North American frequency bands only. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Test results reported herein relate only to the item(s) tested. The SAR Tick is an initiative of the Mobile & Wireless Forum (MWF). While a product may be considered eligible, use of the SAR Tick logo requires an agreement with the MWF. Further details can be obtained by emailing: [email protected]. 1g Head (W/kg) 10g Extremity (W/kg) PCT UMTS 850 826.40 - 846.60 MHz < 0.1 0.18 PCT UMTS 1750 1712.4 - 1752.6 MHz 0.37 < 0.1 PCT UMTS 1900 1852.4 - 1907.6 MHz 0.68 0.10 PCT LTE Band 26 (Cell) 814.7 - 848.3 MHz < 0.1 0.20 PCT LTE Band 5 (Cell) 824.7 - 848.3 MHz < 0.1 0.18 PCT LTE Band 66 (AWS) 1710.7 - 1779.3 MHz 0.37 < 0.1 PCT LTE Band 4 (AWS) 1710.7 - 1754.3 MHz N/A N/A PCT LTE Band 25 (PCS) 1850.7 - 1914.3 MHz 0.42 0.11 PCT LTE Band 2 (PCS) 1850.7 - 1909.3 MHz N/A N/A PCT LTE Band 7 2502.5 - 2567.5 MHz 0.46 0.32 PCT LTE Band 41 2498.5 - 2687.5 MHz 0.33 < 0.1 DTS 2.4 GHz WLAN 2412 - 2472 MHz 0.14 < 0.1 DSS/DTS Bluetooth 2402 - 2480 MHz < 0.1 < 0.1 0.82 0.38 Equipment Class SAR Simultaneous SAR per KDB 690783 D01v01r03: Band & Mode Tx Frequency PCTEST 18855 Adams Ct, Morgan Hill, CA 95037 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctest.com SAR EVALUATION REPORT FCC ID: BCG-A2356 SAR EVALUATION REPORT Approved by: Quality Manager Document S/N: Test Dates: DUT Type: Page 2 of 58 1C2004270026-01-R1.BCG 06/29/2020 â 08/26/2020 Watch © 2020 PCTEST REV 21.4 M 09/11/2019 © 2020 PCTEST All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from PCTEST. If you have any questions about this international copyright or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. T A B L E O F C O N T E N T S 1 DEVICE UNDER TEST .................................................................................................................................3 2 LTE INFORMATION ......................................................................................................................................8 3 INTRODUCTION ...........................................................................................................................................9 4 DOSIMETRIC ASSESSMENT ................................................................................................................... 10 5 TEST CONFIGURATION POSITIONS....................................................................................................... 11 6 RF EXPOSURE LIMITS ............................................................................................................................. 12 7 FCC MEASUREMENT PROCEDURES ..................................................................................................... 13 8 RF CONDUCTED POWERS ...................................................................................................................... 17 9 SYSTEM VERIFICATION ........................................................................................................................... 38 10 SAR DATA SUMMARY .............................................................................................................................. 42 11 FCC MULTI-TX AND ANTENNA SAR CONSIDERATIONS ...................................................................... 50 12 SAR MEASUREMENT VARIABILITY ........................................................................................................ 53 13 EQUIPMENT LIST ...................................................................................................................................... 54 14 MEASUREMENT UNCERTAINTIES.......................................................................................................... 55 15 CONCLUSION ..................................................................................................................................âŠ
Text truncated - open the document above for the full version.
Object: Date Issued: Page 3 of 4 D1750V2 â SN: 1092 05/15/2019 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: Page 4 of 4 D1750V2 â SN: 1092 05/15/2019 Impedance & Return-Loss Measurement Plot for Body TSL Object: Date Issued: Page 1 of 4 D1750V2 â SN: 1092 5/15 /2020 Certification of Calibration Object D1750V2 â SN: 1092 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extended Calibration date: May 15, 2020 Description: SAR Validation Dipole at 1750 MHz. Calibration Equipment used: Measurement Uncertainty = ±23% (k=2) Name Function Signature Calibrated By: Parker Jones Team Lead Engineer Approved By: Kaitlin OâKeefe Managing Director Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent 8753ES S-Parameter Network Analyzer 1/16/2020Annual 1/16/2021US39170118 Agilent N5182A MXG Vector Signal Generator 8/19/2019Annual 8/19/2020MY47420837 Amplifier Research 15S1G6 Amplifier CBTN/ACBT343972 Anritsu MA2411B Pulse Power Sensor 1/21/2020Annual 1/21/20211207470 Anritsu MA2411B Pulse Power Sensor 1/21/2020Annual 1/21/20211339007 Anritsu ML2495A Power Meter 1/15/2020Annual 1/15/20211328004 Control Company 62344-734 Therm./ Clock/ Humidity Monitor 3/18/2019Biennial 3/18/2021192038436 Control Company 4352Ultra Long Stem Thermometer 8/2/2018Biennial 8/2/2020181292000 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 7/2/2019Annual 7/2/2020MY53401181 MiniCircuits VLF-6000+ Low Pass Filter CBTN/ACBTN/A Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB Attenuator CBTN/ACBTN/A Narda 4772-3 Attenuator (3dB) CBTN/ACBT9406 Pasternack PE2208-6 Bidirectional Coupler CBTN/ACBTN/A Pasternack NC-100 Torque Wrench 5/23/2018Biennial 5/23/2020N/A SPEAG DAE4 Dasy Data Acquisition Electronics 2/13/2020Annual 2/13/20211403 SPEAG DAE4 Dasy Data Acquisition Electronics 3/19/2020Annual 3/19/2021604 SPEAG DAK-3.5 Dielectric Assessment Kit 5/12/2020Annual 5/12/20211070 SPEAG EX3DV4 SAR Probe 2/19/2020Annual 2/19/20217427 SPEAG EX3DV4 SAR Probe 3/20/2020Annual 3/20/20217421 PCTEST 18855 Adams Ct, Morgan Hill, CA 95037 USA Tel. +1.410.290.6652 / Fax +1.410.290.6654 http://www.pctest.com Object: Date Issued: Page 2 of 4 D1750V2 â SN: 1092 5/15 /2020 DIPOLE CALIBRATION EXTENSION Per KDB 865664 D01, calibration intervals of up to three years may be considered for reference dipoles when it is demonstrated that the SAR target, impedance and return loss of a dipole have remained stable according to the following requirements: 1. The measured SAR does not deviate more than 10% from the target on the calibration certificate. 2. The return-loss does not deviate more than 20% from the previous measurement and meets the required 20dB minimum return-loss requirement. 3. The measurement of real or imaginary parts of impedance does not deviate more than 5Ω from the previous measurement. The following dipole was checked to pass the above 3 requirements to have 3-year calibration period from the calibration date: Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Head (1g) W/kg @ 20.0 dBm Measured Head SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Head (10g) W/kg @ 20.0 dBm Measured Head SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Head (Ohm) Real Measured Impedance Head (Ohm) Real Difference (Ohm) Real Certificate Impedance Head (Ohm) Imaginary Measured Impedance Head (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Head (dB) Measured Return Loss Head (dB) Deviation (%)PASS/FAIL 5/15/20185/15/20201.2173.613.72.49%1.91.973.68%49.246.72.5-1-21-37.8-3118.00%PASS Calibration Date Extension Date Certificate Electrical Delay (ns) Certificate SAR Target Body (1g) W/kg @ 20.0 dBm Measured Body SAR (1g) W/kg @ 20.0 dBm Deviation 1g (%) Certificate SAR Target Body (10g) W/kg @ 20.0 dBm Measured Body SAR (10g) W/kg @ 20.0 dBm Deviation 10g (%) Certificate Impedance Body (Ohm) Real Measured Impedance Body (Ohm) Real Difference (Ohm) Real Certificate Impedance Body (Ohm) Imaginary Measured Impedance Body (Ohm) Imaginary Difference (Ohm) Imaginary Certificate Return Loss Body (dB) Measured Return Loss Body (dB) Deviation (%)PASS/FAIL 5/15/20185/15/20201.2173.643.773.57%1.9423.09%44.843.71.1-0.6-0.10.5-25.2-23.66.30%PASS Object: Date Issued: Page 3 of 4 D1750V2 â SN: 1092 5/15 /2020 Impedance & Return-Loss Measurement Plot for Head TSL Object: Date Issued: Page 4 of 4 D1750V2 â SN: 1092 5/15 /2020 Impedance & Return-Loss Measurement Plot for Body TSL Object: Date Issued: Page 1 of 4 D1900V2 â SN: 5d181 09/07/2018 Certification of Calibration Object D1900V2 â SN: 5d181 Calibration procedure(s) Procedure for Calibration Extension for SAR Dipoles. Extended Calibration date: September 07, 2018 Description: SAR Validation Dipole at 1900 MHz. Calibration Equipment used: Measurement Uncertainty = ±23% (k=2) Name Function Signature Calibrated By: Sangmin Cha Team Lead Engineer Approved By: Kaitlin OâKeefe Senior Technical Manager Manufacturer Model Description Cal Date Cal Interval Cal Due Serial Number Agilent 8753ES S-Parameter Network Analyzer 9/14/2017 Annual 9/14/2018 US39170118 Agilent N5182A MXG Vector Signal Generator 3/19/2018 Annual 3/19/2019 US46240505 Amplifier Research 15S1G6 Amplifier CBT N/A CBT 343972 Anritsu ML2496A Power Meter 10/9/2017 Annual 10/9/2018 1138001 Anritsu MA2411B Pulse Power Sensor 11/15/2017 Annual 11/15/2018 1339007 Anritsu MA2411B Pulse Power Sensor 11/22/2017 Annual 11/22/2018 1339008 Control Company 4040 Temperature / Humidity Monitor 2/28/2018 Biennial 2/28/2020 150761911 Control Company 4352 Ultra Long Stem Thermometer 2/14/2017 Biennial 2/14/2019 170112507 Keysight 772D Dual Directional Coupler CBT N/A CBT MY52180215 Keysight Technologies 85033E Standard Mechanical Calibration Kit (DC to 9GHz, 3.5mm) 6/4/2018 Annual 6/4/2019 MY53401181 Mini-Circuits BW-N20W5+ DC to 18 GHz Precision Fixed 20 dB AttenuâŠ
Text truncated - open the document above for the full version.
FCC ID: BCG-A2356 MEASUREMENT REPORT (CERTIFICATION) Approved by: Quality Manager Test Report S/N: Test Dates: EUT Type: Page 1 of 60 1C2004270026-08.BCG 05/01/2020 - 09/01/2020 Watch © 2020 PCTEST V 10.1 02/01/2020 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from PCTEST. If you have any questions about this international copyright or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. Applicant Name: Apple Inc. One Apple Park Way Cupertino, CA 95014 United States Date of Testing: 05/01/2020 - 09/01/2020 Test Site/Location: PCTEST Lab. Morgan Hill, CA, USA Test Report Serial No.: 1C2004270026-08.BCG FCC ID: BCG-A2356 IC: 579C-A2356 APPLICANT: Apple Inc. Application Type: Certification Model/HVIN: A2356 EUT Type: Watch Max. RF Output Power: 56.885 mW (17.55 dBm) Peak Conducted Frequency Range: 2402 â 2480MHz Type of Modulation: GFSK, ï°/4-DQPSK, 8DPSK FCC Classification: FCC Part 15 Spread Spectrum Transmitter (DSS) FCC Rule Part(s): Part 15 Subpart C (15.247) ISED Specification: RSS-247 Issue 2 Test Procedure(s): ANSI C63.10-2013 This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.10-2013. Test results reported herein relate only to the item(s) tested. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. PCTEST 18855 Adams Court, Morgan Hill, CA 95037 USA Tel. 410.290.6652 / Fax 410.290.6654 http://www.pctest.com MEASUREMENT REPORT FCC PART 15.247 / ISED RSS-247 Bluetooth FCC ID: BCG-A2356 MEASUREMENT REPORT (CERTIFICATION) Approved by: Quality Manager Test Report S/N: Test Dates: EUT Type: Page 2 of 60 1C2004270026-08.BCG 05/01/2020 - 09/01/2020 Watch © 2020 PCTEST V 10.1 02/01/2020 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from PCTEST. If you have any questions about this international copyright or have an enquiry about obtaining additional rights to this report or assembly of contents thereof, please contact [email protected]. T A B L E O F C O N T E N T S 1.0 INTRODUCTION ...........................................................................................................................................3 1.1 Scope ................................................................................................................................................................... 3 1.2 PCTEST Test Location ......................................................................................................................................... 3 1.3 Test Facility / Accreditations ................................................................................................................................. 3 2.0 PRODUCT INFORMATION ...........................................................................................................................4 2.1 Equipment Description ......................................................................................................................................... 4 2.2 Device Capabilities ............................................................................................................................................... 4 2.3 Antenna Description ............................................................................................................................................. 6 2.4 Test Support Equipment ....................................................................................................................................... 6 2.5 Test Configuration ................................................................................................................................................ 7 2.6 Software and Firmware ........................................................................................................................................ 7 2.7 EMI Suppression Device(s)/Modifications ............................................................................................................ 7 3.0 DESCRIPTION OF TESTS ...........................................................................................................................8 3.1 Evaluation Procedure ........................................................................................................................................... 8 3.2 AC Line Conducted Emissions ............................................................................................................................. 8 3.3 Radiated Emissions .............................................................................................................................................. 9 3.4 Environmental Conditions ..................................................................................................................................... 9 4.0 ANTENNA REQUIREMENTS .................................................................................................................... 10 5.0 MEASUREMENT UNCERTAINTY ............................................................................................................. 11 6.0 TEST EQUIPMENT CALIBRATION DATA ................................................................................................ 12 7.0 TEST RESULTS ........âŠ
Text truncated - open the document above for the full version.
Apple Inc. FCC ID: BCG-A2356; IC: 579C-A2356 Model: A2356 Test Set-Up Photos EUT Type: Watch Page 1 of 7 © 2020 PCTEST V 10.1 02/01/2020 T E S T S E T U P P H O T O G R A P H S Apple Inc. FCC ID: BCG-A2356; IC: 579C-A2356 Model: A2356 Test Set-Up Photos EUT Type: Watch Page 2 of 7 © 2020 PCTEST V 10.1 02/01/2020 Apple Inc. FCC ID: BCG-A2356; IC: 579C-A2356 Model: A2356 Test Set-Up Photos EUT Type: Watch Page 3 of 7 © 2020 PCTEST V 10.1 02/01/2020 Apple Inc. FCC ID: BCG-A2356; IC: 579C-A2356 Model: A2356 Test Set-Up Photos EUT Type: Watch Page 4 of 7 © 2020 PCTEST V 10.1 02/01/2020 Apple Inc. FCC ID: BCG-A2356; IC: 579C-A2356 Model: A2356 Test Set-Up Photos EUT Type: Watch Page 5 of 7 © 2020 PCTEST V 10.1 02/01/2020 Apple Inc. FCC ID: BCG-A2356; IC: 579C-A2356 Model: A2356 Test Set-Up Photos EUT Type: Watch Page 6 of 7 © 2020 PCTEST V 10.1 02/01/2020 Apple Inc. FCC ID: BCG-A2356; IC: 579C-A2356 Model: A2356 Test Set-Up Photos EUT Type: Watch Page 7 of 7 © 2020 PCTEST V 10.1 02/01/2020
One Apple Park Way · Cupertino, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 57.00 mW |
Smartphone
Equipment Class
6VL - 15E 6 GHZ Very Low Power DeviceMagnetic Charging Cable
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzMagnetic Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzMagnetic Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzSmartphone
Equipment Class
PCE - PCS Licensed Transmitter held to ear