Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
LG Electronics USA 1000 Sylvan Avenue Englewood Cliffs, NJ 07632 Date: May 15, 2008 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 RE: Request of Confidentiality for FCC ID: BEJAX155 Equipment Class: PCE: PCS Licensed Transmitter held to ear To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, LG Electronics USA hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give LG Electronics USA temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Temporary Confidential exhibits are listed as follows: PERMANENT AND SHORT-TERM CONFIDENTIAL LIST Exhibit Description 1 Block Diagram 2 Operational Descriptions 3 Parts Lists and Tune-Up Procedure PERMANENT 4 Schematics 5 External Photos 6 Internal Photos 7 Test-Setup Photos SHORT-TERM 8 User’s Manual The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Sincerely, Daniel Kim General Manager LG Electronics USA
Date: May 15, 2008 Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 SUBJECT: LG Electronics Inc. FCC ID: BEJAX155 Part 20.19 Certification Gentlemen: We, LG Electronics USA, hereby declare the samples evaluated in this application are equivalent to production samples. Should you have any questions or comments concerning the above, please contact the undersigned. Sincerely, Daniel Kim General Manager LG Electronics USA LG Electronics Inc. LGE LG Electronics USA 1000 Sylvan Avenue Englewood Cliffs, NJ 07632
Reviewed by: FCC ID: BEJAX155 CERTIFICATION REPORT Quality Manager SAR Filename: Test Dates: EUT Type: 0804140483.BEJ 04/19/08 - 04/28/08 Cellular/PCS CDMA Phone Page 1 of 26 © 2008 PCTEST Engineering Laboratory, Inc. REV 5.1C 04/21/08 Applicant Name: Date of Testing: LG Electronics USA 04/19/08 - 04/28/08 1000 Sylvan Avenue Test Site/Location: Englewood Cliffs, NJ 07632 PCTEST Lab, Columbia, MD, USA United States Test Report Serial No.: 0804140483.BEJ F C C I D : BE J AX 1 5 5 AP P L I C AN T : LG E LE CT RO NI CS US A EUT Type: Cellular/PCS CDMA Phone Application Type: Certification FCC Rule Part(s): §2.1093; FCC/OET Bulletin 65 Supplement C [July 2001] FCC Classification: Licensed Transmitter Held to Ear (PCE) Model(s): AX155 Tx Frequency: 824.70 - 848.31 MHz (Cellular CDMA) / 1851.25 - 1908.75 MHz (PCS CDMA) Conducted Power: 24.51 dBm Cellular CDMA / 25.12 dBm PCS CDMA Max. SAR Measurement: 1.26 W/kg CDMA Head SAR / 0.368 W/kg CDMA Body SAR 0.787 W/kg PCS Head SAR / 0.234 W/kg PCS Body SAR Test Device Serial No.: Pre-Production [S/N: A0000007DC26FC] This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-2005 and has been tested in accordance with the measurement procedures specified in FCC/OET Bulletin 65 Supplement C (2001) and IEEE Std. 1528-2003 and in applicable Industry Canada Radio Standards Specifications (RSS). I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Grant Conditions: Power output listed is ERP for Part 22 and EIRP for Part 24. SAR compliance for body-worn operating configuration is based on a separation distance of 2.0 cm between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters not specified in this filing may not contain metallic components. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. PCTEST ENGINEERING LABORATORY, INC. 6660-B Dobbin Road, Columbia, MD 21045 USA Tel. 410.290.6652 / Fax 410.290.6554 http://www.pctestlab.com CERTIFICATE OF COMPLIANCE (SAR EVALUATION) Reviewed by: FCC ID: BEJAX155 CERTIFICATION REPORT Quality Manager SAR Filename: Test Dates: EUT Type: 0804140483.BEJ 04/19/08 - 04/28/08 Cellular/PCS CDMA Phone Page 2 of 26 © 2008 PCTEST Engineering Laboratory, Inc. REV 5.1C 04/21/08 T A B L E O F C O N T E N T S 1 INTRODUCTION ..............................................................................................................................3 2 TEST SITE LOCATION ....................................................................................................................4 3 SAR MEASUREMENT SETUP ........................................................................................................5 4 DASY E-FIELD PROBE SYSTEM ...................................................................................................7 5 PROBE CALIBRATION PROCESS .................................................................................................8 6 PHANTOM AND EQUIVALENT TISSUES.......................................................................................9 7 DOSIMETRIC ASSESSMENT & PHANTOM SPECS....................................................................10 8 DEFINITION OF REFERENCE POINTS .......................................................................................11 9 TEST CONFIGURATION POSITIONS ..........................................................................................12 10 RF EXPOSURE LIMITS .................................................................................................................15 11 MEASUREMENT UNCERTAINTIES .............................................................................................16 12 SYSTEM VERIFICATION...............................................................................................................17 13 FCC 3G MEASUREMENT PROCEDURES ...................................................................................18 14 SAR DATA SUMMARY ..................................................................................................................20 15 EQUIPMENT LIST..........................................................................................................................23 16 CONCLUSION................................................................................................................................24 17 REFERENCES ...............................................................................................................................25 Reviewed by: FCC ID: BEJAX155 CERTIFICATION REPORT Quality Manager SAR Filename: Test Dates: EUT Type: 0804140483.BEJ 04/19/08 - 04/28/08 Cellular/PCS CDMA Phone Page 3 of 26 © 2008 PCTEST Engineering Laboratory, Inc. REV 5.1C 04/21/08 1 I N T R O D U C T I O N The FCC has adopted the guidelines for evaluating the environmental effects of radio frequency (RF) radiation in ET Docket 93-62 on Aug. 6, 1996 to protect the public and workers from the potential hazards of RF emissions due to FCC-regulated portable devices.[1] The safety limits used for the environmental evaluation measurements are based on the criteria published by the American National Standards Institute (ANSI) for localized specific absorption rate (SAR) in IEEE/ANSI C95.1-2005 Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz[2] and Health Canada RF Exposure Guidelines Safety Code …
Text truncated - open the document above for the full version.
Reviewed by: FCC ID: BEJAX155 FCC Pt. 22/24 CDMA MEASUREMENT REPORT (CERTIFICATION) Quality Manager Test Report S/N: Test Dates: EUT Type: 0804140482.BEJ April 30, 2008 Cellular/PCS CDMA Phone Page 1 of 35 © 2008 PCTEST Engineering Laboratory, Inc. REV 7.4C 02/19/2008 Applicant Name: Date of Testing: LG Electronics USA April 30, 2008 1000 Sylvan Avenue Test Site/Location: Englewood Cliffs, NJ 07632 PCTEST Lab., Columbia, MD, USA United States Test Report Serial No.: 0804140482.BEJ FCC ID: BEJAX155 APPLICANT: LG ELECTRONICS USA Application Type: Certification FCC Classification: PCS Licensed Transmitter Held to Ear (PCE) FCC Rule Part(s): §2; §22(H), §24(E) EUT Type: Cellular/PCS CDMA Phone Model(s): AX155 Tx Frequency Range: 824.70 - 848.31MHz (Cell. CDMA) / 1851.25 - 1908.75MHz (PCS CDMA) Max. RF Output Power: 0.258 W ERP Cell. CDMA (24.11 dBm) 0.509 W EIRP PCS CDMA (27.07 dBm) Emission Designator(s): 1M27F9W (CDMA) / 1M27F9W (PCS) Test Device Serial No.: identical prototype [S/N: 0515-0027] This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in §2.947. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Grant Conditions: Power output listed is ERP for Part 22 and EIRP for Part 24. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. PCTEST ENGINEERING LABORATORY, INC. 6660-B Dobbin Road, Columbia, MD 21045 USA Tel. 410.290.6652 / Fax 410.290.6554 http://www.pctestlab.com CERTIFICATE OF COMPLIANCE FCC Part 22 & 24 Certification Reviewed by: FCC ID: BEJAX155 FCC Pt. 22/24 CDMA MEASUREMENT REPORT (CERTIFICATION) Quality Manager Test Report S/N: Test Dates: EUT Type: 0804140482.BEJ April 30, 2008 Cellular/PCS CDMA Phone Page 2 of 35 © 2008 PCTEST Engineering Laboratory, Inc. REV 7.4C 02/19/2008 TABLE OF CONTENTS FCC PART 22 & 24 MEASUREMENT REPORT...........................................................................3 1.0 INTRODUCTION ..............................................................................................................................4 1.1 SCOPE ................................................................................................................................................ 4 1.2 TESTING FACILITY............................................................................................................................. 4 2.0 PRODUCT INFORMATION..............................................................................................................5 2.1 EQUIPMENT DESCRIPTION .............................................................................................................. 5 2.2 EMI SUPPRESSION DEVICE(S)/MODIFICATIONS ........................................................................... 5 2.3 LABELING REQUIREMENTS.............................................................................................................. 5 3.0 DESCRIPTION OF TESTS ..............................................................................................................6 3.1 MEASUREMENT PROCEDURE......................................................................................................... 6 3.2 OCCUPIED BANDWIDTH EMISSION LIMITS .................................................................................... 6 3.3 CELLULAR - BASE FREQUENCY BLOCKS....................................................................................... 6 3.4 CELLULAR - MOBILE FREQUENCY BLOCKS................................................................................... 7 3.5 PCS - BASE FREQUENCY BLOCKS .................................................................................................. 7 3.6 PCS - MOBILE FREQUENCY BLOCKS .............................................................................................. 7 3.7 SPURIOUS AND HARMONIC EMISSIONS AT ANTENNA TERMINAL.............................................. 7 3.8 RADIATED SPURIOUS AND HARMONIC EMISSIONS ..................................................................... 8 3.9 FREQUENCY STABILITY / TEMPERATURE VARIATION ................................................................. 8 4.0 TEST EQUIPMENT CALIBRATION DATA ......................................................................................9 5.0 SAMPLE CALCULATIONS ............................................................................................................10 6.0 TEST RESULTS .............................................................................................................................11 6.1 SUMMARY......................................................................................................................................... 11 6.2 EFFECTIVE RADIATED POWER OUTPUT DATA ........................................................................... 12 6.3 EQUIVALENT ISOTROPIC RADIATED POWER OUTPUT DATA .................................................... 13 6.4 CELLULAR CDMA RADIATED MEASUREMENTS........................................................................... 14 6.5 PCS CDMA RADIATED MEASUREMENTS...................................................................................... 17 6.6 CELLULAR CDMA FREQUENCY STABILITY MEASUREMENTS ................................................... 20 6.7 PCS CDMA FREQUENCY STABILITY MEASUREMENTS............................................................... 22 7.0 PLOT(S) OF EMISSIONS ..............................................................................................................24 8.0 CONCLUSIO…
Text truncated - open the document above for the full version.
Reviewed by: COMPANY NAME:LG Electronics USA Quality Manager Test Date(s): EUT Type: FCC ID: BEJAX155 April 30, 2008 Cellular/PCS CDMA Phone Page 1 of 2 TEST SETUP PHOTOGRAPHS Reviewed by: COMPANY NAME:LG Electronics USA Quality Manager Test Date(s): EUT Type: FCC ID: BEJAX155 April 30, 2008 Cellular/PCS CDMA Phone Page 2 of 2
6660-B Dobbin Road · Columbia, Maryland · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 24E | 1.85 GHz - 1.91 GHz | 509.00 mW | 1M27F9W | 2.5 ppm |

Telematics
Equipment Class
DTS - Digital Transmission SystemNotebook Computer
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterStylus Pen
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzRF Module
Equipment Class
FDS - Part 15 Field Disturbance SensorTelematics
Equipment Class
NII - Unlicensed National Information Infrastructure TX