Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX H : USERβS MANUAL FCC ID: BEJL196WTQ Make sure to read the Important Precautionsbefore using the product. Keep the User's Guide(CD) in an accessible place for future reference. See the label attached on the product and give the information to your dealer when you ask for service. L196WTG L206WTG L196WTQ L206WTQ Userβs Guide A1 This unit has been engineered and manufactured to ensure your personal safety, however improper use may result in potential electrical shock or fire hazards. In order to allow the proper operation of all safeguards incorporated in this display, observe the following basic rules for its installation, use, and servicing. On Safety Use only the power cord supplied with the unit. In case you use another power cord, make sure that it is certified by the applicable national standards if not being provided by the supplier. If the power cable is faulty in any way, please contact the manufacturer or the nearest authorized repair service provider for a replacement. The power supply cord is used as the main disconnection device. Ensure that the socket-outlet is easily accessible after installation. Operate the display only from a power source indicated in the specifications of this manual or listed on the display. If you are not sure what type of power supply you have in your home, consult with your dealer. Overloaded AC outlets and extension cords are dangerous. So are frayed power cords and broken plugs. They may result in a shock or fire hazard. Call your service technician for replacement. Do not Open the Display. There are no user serviceable components inside. There are Dangerous High Voltages inside, even when the power is OFF. Contact your dealer if the display is not operating properly. To Avoid Personal Injury : Do not place the display on a sloping shelf unless properly secured. Use only a stand recommended by the manufacturer. To Prevent Fire or Hazards: Always turn the display OFF if you leave the room for more than a short period of time. Never leave the display ON when leaving the house. Keep children from dropping or pushing objects into the display's cabinet openings. Some internal parts carry hazardous voltages. Do not add accessories that have not been designed for this display. During a lightning storm or when the display is to be left unattended for an extended period of time, unplug it from the wall outlet. Important Precautions A2 Important Precautions On Installation Do not allow anything to rest upon or roll over the power cord, and do not place the display where the power cord is subject to damage. Do not use this display near water such as near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. Displays are provided with ventilation openings in the cabinet to allow the release of heat generated during operation. If these openings are blocked, built-up heat can cause failures which may result in a fire hazard. Therefore, NEVER: Block the bottom ventilation slots by placing the display on a bed, sofa, rug, etc. Place the display in a built-in enclosure unless proper ventilation is provided. Cover the openings with cloth or other material. Place the display near or over a radiator or heat source. Do not rub or strike the Active Matrix LCD with anything hard as this may scratch, mar, or damage the Active Matrix LCD permanently. Do not press the LCD screen with your finger for a long time as this may cause some afterimages. Some dot defects may appear as Red, Green or Blue spots on the screen. However, this will have no impact or effect on the display performance. If possible, use the recommended resolution to obtain the best image quality for your LCD display. If used under any mode except the recommended resolution, some scaled or processed images may appear on the screen. However, this is characteristic of the fixed-resolution LCD panel. On Cleaning Unplug the display before cleaning the face of the display screen. Use a slightly damp (not wet) cloth. Do not use an aerosol directly on the display screen because over-spraying may cause electrical shock. On Repacking Do not throw away the carton and packing materials. They make an ideal container in which to transport the unit. When shipping the unit to another location, repack it in its original material. On Disposal The fluorescent lamp used in this product contains a small amount of mercury. Do not dispose of this product with general household waste. Disposal of this product must be carried out in accordance to the regulations of your local authority. A3 Connecting the Display Important This illustration depicts the general model of connection. Your monitor may differ from the items shown in the picture. Do not carry the product upside down holding only the stand base. The product may fall and get damaged or injure your foot. Before setting up the monitor, ensure that the power to the monitor, the computer system, and other attached devices is turned off. Connecting the stand 1.Place the monitor with its front facing downward on a soft cloth. 2 . Assemble the Stand Body into the product in the correct direction as shown in the picture. 3.Assemble the Stand Base(Front, Rear) into the Stand Body in the correct direction. But,Assemble the Stand Body with Stand Base to fix firmly. 4.Once assembled take the monitor up carefully and face the front side Stand Body Stand Base Stand Body Hinge Body A4 Connecting the Display Disassembling the stand 1.Put a cushion or soft cloth on aflat surface. 3.Pushing Latch inside, Take the stand base from stand body. 4.Pull Stand Body lightly to separate from Hinge Body. 2.Place the monitor face Down on the cushion or soft cloth. A5 Connecting the Display Before setting up the monitor, ensure that the power to the monitor, the computer system, and other attached devices is turned off. Positioning your display 1.Adjust the position of the β¦
Text truncated - open the document above for the full version.
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX A : ATTESTATION STATEMENT FCC ID: BEJL196WTQ September 5, 2006 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 U.S.A To whom it may concern: We, the undersigned, hereby authorize GUMI College EMC Center to act on our behalf in all matters relating to applications for equipment authorization, including the signing of all documents relation to these matters. Any and all acts carried out by GUMI College EMC Center on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to the application is subject of a denial of benefits, including FCC benefits, pursuant 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Sincerely, Sang-Wook Lee, Chief research engineer LG Electronics Inc.
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX D : BLOCK DIAGRAM FCC ID: BEJL196WTQ Bl ock di agr a m L V D S L V D S L V D S An a l og I ( R/G/B ) D-Sub LIPS Fil t er 5V 12V 5V R e g u lato r R e g u lato r 3.3V Vcc5V In v e rt er(1 2L a m p s ) 12V 12V Flash RO M Flash RO M DVI-D DVI ( T M DS) KEY 1.8V 1.8V 3.3V Module SDA/S CL EEPROM (EDID ) EEPROM (EDID ) EEPROM (S ystem) EEPROM (S ystem) 3.3V ADC TMDS Rx Scaler MStarACE LVDS Tx OS D MCU SSC Li ne Buffer 12V TSUM O 5 P W H J -L F EEPROM (EDID ) EEPROM (EDID ) Cryst a l Cryst a l X50 1 : 14.31MHz 68MH z DESCRIPTION OF BLOCK DIAGRAM 1. Video Controlle r P art . This part amplifies the level of video signal for the digital c onversion and converts from the analog vi deo signal to the digi t al vid eo si g nal using a pix e l clo c k. The pixel clock for each mode is g e nerate d by the P LL. The range of the pixe l clock i s 2 5 MHz to 1 36MHz In L19 6 WTQ. This part consis t s of the Scale r , ADC converto r, TMD S receiv er and LVDS transmit t er. The Scaler gets the video signal converted analog to digital, in terpol ate s i n put to 1440X900( L196WTQ) re solution signal a nd outputs 8-bi t R, G , B signal to t r ansmitt e r . . 2. Pow er P art . This part consists of the one 3. 3V, and one 1.8V regulators to convert po wer which is p r ovid e d 5V in Power bo a rd . 12V is pro v ided for i nverter in L19 6WTQ. Also, 5V is converted 3.3V and 1.8V by re g ulator. Converted p o w er i s provided for IC in the main board. The inverter converts from DC 12V to AC 700Vrms and operate s b a ck-lig ht lamps o f module in L19 6 WTQ. 3. MICOM Part.This part i s include v ideo controller part. And this p art consi s t s of EEPROM IC whi ch store s FRC(OD) memory, control dat a , Re s e t IC and the Micom. The Micom d istinguishe s pol ari t y and freq uency of the H/V sync a re supplied from signal cabl e. The controlled d a t a o f each modes i s st ored in EEP ROM.
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX F : EXTERNAL PHOTOGRAPHS FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX C : ID SAMPLE LABEL & LOCATION FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor LABELLING REQUIREMENTS The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. Β ID Label Β ID Label Location of EUT I.D Label FCC ID: BEJL196WTQ
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX G : INTERNAL PHOTOGRAPHS FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor FCC ID: BEJL196WTQ
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX B : PLOTS OF CONDUCTED EMISSIONS FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor Β Test Mode: 1440* 900/ 75Hz(Analog) < Hot line > < Neutral line > FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor Β Test Mode: 1440* 900/ 75Hz(Digital) < Hot line > < Neutral line > FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor Β Test Mode:1024 *768 / 75Hz (Analog) < Hot line > < Neutral line > FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor Β Test Mode: 640*480 / 60Hz (Analog) < Hot line > < Neutral line > FCC ID: BEJL196WTQ
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor CONTENTS 1. GENERAL INFORMATION......................................................................................................................................3 2. INTRODUCTION........................................................................................................................................................4 3. PRODUCT INFORMATION......................................................................................................................................5 3.1 DESCRIPTION OF EUT..............................................................................................................................................5 3.2 SUPPORT EQUIPMENT / CABLES USED.....................................................................................................................6 3.3 MODIFICATION ITEM(S)...........................................................................................................................................6 4. DESCRIPTION OF TESTS.........................................................................................................................................7 4.1 TEST CONDITION......................................................................................................................................................7 4.2 CONDUCTED EMISSION............................................................................................................................................8 4.3 RADIATED EMISSION................................................................................................................................................9 5. CONDUCTED EMISSION........................................................................................................................................10 5.1 OPERATING ENVIRONMENT...................................................................................................................................10 5.2 TEST SET-UP............................................................................................................................................................10 5.3 MEASUREMENT UNCERTAINTY..............................................................................................................................10 5.4 LIMIT......................................................................................................................................................................11 5.5 TEST EQUIPMENT USED..........................................................................................................................................11 5.6 TEST DATA FOR POWER LINE CONDUCTED EMISSION............................................................................................12 6. RADIATED EMISSION............................................................................................................................................16 6.1 OPERATING ENVIRONMENT...................................................................................................................................16 6.2 TEST SET-UP............................................................................................................................................................16 6.3 MEASUREMENT UNCERTAINTY..............................................................................................................................16 6.4 LIMIT......................................................................................................................................................................17 6.5 TEST EQUIPMENT USED..........................................................................................................................................17 6.6 TEST DATA FOR RADIATED EMISSION.....................................................................................................................18 7. SAMPLE CALCULATIONS.....................................................................................................................................22 7.1 EXAMPLE 1 :...........................................................................................................................................................22 7.2 EXAMPLE 2 :...........................................................................................................................................................22 8. RECOMMENDATION & CONCLUSION..............................................................................................................23 APPENDIX A β ATTESTATION STATEMENT APPENDIX B β PLOTS OF CONDUCTED EMISSIONS APPENDIX C β ID SAMPLE LABEL & LOCATION APPENDIX D β BLOCK DIAGRAM APPENDIX E β TEST SET-UP PHOTOGRAPHS APPENDIX F β EXTERNAL PHOTOGRAPHS APPENDIX G βINTERNAL PHOTOGRAPHS APPENDIX H β USERβS MANUAL FCC ID: BEJL196WTQ Page 2 of 23 Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor Scope: Measurement and determination of electromagnetic emissions (EME) of radio frequency devices including intentional and / or unintentional radiators for compliance with technical rules and regulations of the Federal Communications Commission. 1. General Information Applicant: LG Electronics Inc. Applicant Address: 642, Jinpyeong-Dong, Gumi-Si, Gyeongsangbuk-do, Korea Manufacturer: LG Electronics Inc. Manufacturer Address: 642, Jinpyeong-Dong, Gumi-Si, Gyeongsangbuk-do, Korea Contact Person: Sang -Wook Lee, Chief research engineer Tel. & Fax No.: Tel No.: +82-54-470-5640 Fax No.: +82-54-470-5629 z FCC ID BEJL196WTQ z EUT Type 19β LCD Monitor z Model No. L196WTQ z Tra de Na me LG z Serial No. Prototype z Rule Part(s) FCC Part 15 Subpart B z Type of Authority Certification z Test Procedure(s) ANSI C63.4 (2003) / Canadian standard ICES-003 z Dates of Test December 19, 2006 z Place of Test Gumi College EMC Center ( FCC Registration No.: 1β¦
Text truncated - open the document above for the full version.
Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor APPENDIX E : TEST SET UP PHOTOGRAPHS FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor The Conducted Test Picture and Radiated Test Picture show the worst-case configuration and cable placement. Β Conducted Test Picture (Front) Β Conducted Test Picture (Rear) FCC ID: BEJL196WTQ Test Report No.: GETEC-E3-06-073 FCC Class B Certification EUT Type: 19β LCD Monitor Β Radiated Test Picture (Front) Β Radiated Test Picture (Rear) FCC ID: BEJL196WTQ
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Telematics
Equipment Class
DTS - Digital Transmission SystemNotebook Computer
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterStylus Pen
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzRF Module
Equipment Class
FDS - Part 15 Field Disturbance SensorTelematics
Equipment Class
NII - Unlicensed National Information Infrastructure TX