
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PLASMA MONITOROWNER’S MANUALPlease read this owner’s manual thoroughly before operatingthe Monitor.Retain it for future reference.Record model number and serial number of the Monitor.See the label attached on the back of the Monitor and relatethis information to your dealer if you ever require service.Model Number : Serial Number : MODEL : MU-50PZ90MQP/NO : 3828VA0410H (RF03GB) 2 Plasma Monitor Warning WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of suffi- cient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appli- ance. WARNING: TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. FCC NOTICE • A Class B digital device This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. • Any changes or modifications not expressly approved by the party responsible for compli- ance could void the user’s authority to operate the equipment. WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. W W arning arning Owner’s Manual 3 Safety Instructions Important safeguards for you and your new product Your product has been manufactured and tested with your safety in mind. However, improper use can result in potential elec- trical shock or fire hazards. To avoid defeating the safeguards that have been built into your new product, please read and observe the following safety points when installing and using your new product, and save them for future reference. Observing the simple precautions discussed in this booklet can help you get many years of enjoyment and safe operation that are built into your new product. This product complies with all applicable U.S. Federal safety requirements, and those of the Canadian Standards Association. 1. Read Instructions All the safety and operating instructions should be read before the product is operated. 2. Follow Instructions All operating and use instructions should be followed. 3. Retain Instructions The safety and operating instructions should be retained for future reference. 4. Heed Warnings All warnings on the product and in the operating instructions should be adhered to. 5. Cleaning Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 6. Water and Moisture Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet base- ment, or near a swimming pool. 7. Accessories, Carts, and Stands Do not place this product on a slippery or tilted surface, or on an unstable cart, stand, tripod, bracket, or table. The product may slide or fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart, stand, tripod, bracket, or table recommended by the manu- facturer, or sold with the product. Any mounting of the prod- uct should follow the manufacturer’s instructions, and should use a mounting accessory recommended by the manufac- turer. 8. Transporting Product A product and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the product and cart combination to overturn. 9. Attachments Do not use attachments not recommended by the product manufacturer as they may cause hazards. 10. Ventilation Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating, and these openings must not be blocked or covered. The openings should never be blocked by plac- ing the product on a bed, sofa, rug, or other similar surface. This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is pro- vided or the manufacturer’s instructions have been adhered to. 11. Power Sources This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your product dealer or local power company. For products intended to operate from battery power, or other sources, refer to the operating instructions. 12. Power-Cord Polarization This product is equipped with a three-wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into the grounding-type power outlet. This is a safety fea- ture. If you are unable to insert the plug into the outlet, con- tact your electrician to replace your obso…
Text truncated - open the document above for the full version.
IC 5 0 1 b ra n d t- I Sc a l e r V/1.8 V #11 Rem 5V /3.3 IC404 F L I2310 _in t er l a c e /2.5 V #10 De 3.3V IC201 A D 9 888 AD C 3.3 V #3 IC 4 0 1 VP C 323 0( M ) Deco d e r 5 V / 3 .3 V # 9 IC202 Sil 169B TM D S _ R X 3.3 V #4 SD R A 3. 3V M (8 M b y t e ) # 1 2 YU V 16 b i t F l a s h - R O M ( 2 MB y 3. 3V t e) SRA M (5 12 K B 3. 3V IC 3 0 1 u P D 6 40 83 3D- C o m b 9 / 5/ 3. 3/ 2. 5 #8 IC 1 0 1 CX A2 0 8 9 SW I T C H I C 302 L A 715 1 SW I T C H I C 104 O P A 3682 AMP 5V #1 SV H S BN C Mo n o s t a b le M u lt i v ib ra t o r YU V 16 b i t 5 0 ” P D P V S C B l ock D i ag ra m 5 0 ” P D P V S C Bl oc k D i ag r a m 74H C T 08 CH 1 CH0 U- C o m ID Y/C Y/ C AV Y/C F L I2310 De _in t er l a c e 3.3V /2.5 V #6 S D RA M ( 8 M by t e ) 3. 3V #7 V P C3 23 0( S ) D ecod e r 5V / 3 .3 V # 5 AV Y/ C Bu f f T541 #6 16 IC7 5 2 74 A C T 2 53 5V ST IC7 0 1 R8 820L V CP U 3.3V # 1 3 ) PD P - 5 0 SD R A M ( 8 M by te ) 3. 3V #7 IC7 5 0 DS 23 2A S RS - 2 3 2 C 5V ST P O RT_ E XT END ( 74L VC 244/ 74L V C 57 4) 3. 3V #1 4 IC6 0 1 Sil 1 6 0 TM D S _ T X 3. 3V #16
Compliance Test Report for FCC Company name Address Telephone Product name Model No. Serial No. Test date2003-10-13~ Test location Standard □Class A■Class BTest resultOK □Class A■Class BTest resultOK Tested by Reviewed by Abbreviation * Note - This is certified that the above mentioned producs have been tested for the sample provided by client - No part of this document may be duplicated or reproduced by any means without the express written permission of the Estech Co., Ltd. Report Number : ESTF150310-001 , Web : www. estech. co. kr Page 1 of 14 Report NumberESTF150310-001 Manufacturer Country of origin Applicant Product 2003-10-13 Plasma Monitor MU-50PZ90MQ NONE LG Electronics Inc. KOREA Date of issue2003-10-13 ESTECH. Co., Ltd. 97-1 Hoiuk-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea Test item ■Conducted Emission ■Radiated Emission FCC PART 15 2002 , ANSI C 63.4 2001 OK, Pass = Passed, Fail = Failed, N/A = not applicable LG Electronics USA 2000 Millbrook Dr Lincolnshire, IL 60069 United states 847-941-8373 Measurement facility registration number Senior Engineer J.M. Yang Director T.K. Lee 94696 (Signature) (Signature) 3 4 5 6 8 8 8 9 10 10 10 11 12 14 Appendix 1. Spectral diagram Appendix 2. Phorographs of EUT in side PCB Appendix 3. Block diagram of EUT Appendix 4. Circuit Diagram Report Number : ESTF150310-001 , Web : www. estech. co. kr Page 2 of 14 5. Measurement of radiated emission ............................................................... 5.1 Measurement e quipment ........................................................................ Contents 1. Laboratory Information ................................................................................. 2. Description of EUT ....................................................................................... 3. Test Standards .......................................................................................... 4. Measurement condition .............................................................................. ... 5.2 Environmental conditions ........................................................................ 5.3 Test data ............................................................................................. 7. Photo graphs of test setup ........................................................................... 8. Photo graphs of EUT .................................................................................... 6. Measurement of conducted emission ............................................................ 6.1 Measurement equipment ........................................................................ 6.2 Environmental conditions ........................................................................ 6.3 Test data ............................................................................................. 1. Laboratory Information 1.1 General 1.2 Test Lab. Corporation Name : ESTECH Co. Ltd Head Office : 3 rd Fl., Chungdam Bldg., 119-1 Chungdam-dong Kangnam-gu , Seoul, Korea (Safety & Telecom. Test Lab) EMC Test Lab : 58-1 Osan-Ri, GaNam-Myon, YeoJoo-Gun, KyungKi-Do, Korea 97-1 Hoiuk-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea 1.3 Official Qualification(s) FCC : Filed Laboratory at Federal Communications Commission This EUT (Equipment Under Test) has been shown to be capable of compliance with the applicable technical standards and is tested in accordance with the measurement procedures as indicated in this report. ESTECH attests to accuracy of test data. All measurement reported herein were performed by ESTECH Co., Ltd. ESTECH assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Report Number : ESTF150310-001 , Web : www. estech. co. kr Page 3 of 14 2. Description of EUT 2.1 Summary of Equipment Under Test Product: Model Number: Serial Number: Manufacturer: Country of origin: Rating : Receipt Date: 2.2 General descriptions of EUT Report Number : ESTF150310-001 , Web : www. estech. co. kr Page 4 of 14 The PDP (Plasma Display Panel) which is the display device of this product is composed of 0.9 to 2.2 million cells. A few cell defects normally occur in the PDP manufacturing process. Several minute colored dots visible on the screen should be acceptable. This also occurs in other PDP manufacturers' products and the dots appearing does not mean that this PDP is defective. Thus a few cell defects are not sufficient cause for the PDP to be exchanged or returned. Our production technology is designed to minimize cell defects during the manufacture and operation of this product. - Width(inches / mm) : 48.2 / 1223 - Height(inches / mm) : 28.9 / 734 - Depth(inches / mm) : 4.1 / 105 - Weight(pounds / kg) : 95.2 / 43.2 - Power requirement : AC120V, 60Hz - Resolution : 1366 × 768 (Dot) Plasma Monitor MU-50PZ90MQ NONE LG Electronics Inc. KOREA 120V, 60Hz 2003-10-11 3. Test Standards Test Standard : FCC PART 15 (2002) Test Method : ANSI C 63.4 (2001) This standard sets forth uniform methods of measurement of radio-frequency (RF) signals and noise emitted from both unintentional and intentional emitters of RF energy in the frequency range 9 kHz to 40 GHz. Methods for the measurement of radiated and AC power-line conducted radio noise are covered and may be applied to any such equipment unless otherwise specified by individual equipment requirements. These methods cover measurement of certain decides that deliberately radiate energy, such as intentional emitters, but does not cover licensed transmitters. This standard is not intended for certification/approval of avionic equipment or for industrial, scientific, and medical (ISM) equipment These method apply to the measurement of individual units or systems comprised of multiple units This Standard sets out the regulations under which an intentional, unintentional, or incidental radiator may be operated without an individual license. It also contains the technical specificati…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Telematics
Equipment Class
DTS - Digital Transmission SystemNotebook Computer
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterStylus Pen
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHzRF Module
Equipment Class
FDS - Part 15 Field Disturbance SensorTelematics
Equipment Class
NII - Unlicensed National Information Infrastructure TX