FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Philips Consumer Lifestyle/
  3. BOUSCD600H

BOUSCD600HBaby Cam Parent Unit

Philips Consumer Lifestyle
Baby Cam Parent Unit - FCC ID BOUSCD600H - Philips Consumer Lifestyle
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 22, 2009
Application Purpose
Original Equipment
Date of Application
Dec 22, 2009
Equipment Note
Baby Cam Parent Unit
Frequency Range
2408.62500000 - 2469.37500000
Company
Philips Consumer Lifestyle
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

25 0000.0000.00.00 2 522 15 789 1011121 1 15117 18 19 20 1 2 2 21 1 16 22 21 20 15 14 17 13 12 11 10 9 1819 2 3 4 5 7 8 1 2 3 4 6 10 11 8 7 12 14 13 5 6 9 2 222225 227 usi 03 2829 01 SCD600 EngliSh 8 8 iMPORTAnT SAFETY inSTRUCTiOnS Some of the following information may not apply to your particular product; however, when using baby monitor equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1 Read these instructions. 2 Keep these instructions. 3 Heed all warnings. 4 Follow all instructions. 5 Do not use this apparatus near water. 6 Clean only with dry cloth. 7 Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8 Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat. 9 Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10 Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11 Only use attachments/accessories specified by the manufacturer. 12 Unplug this appliance during lightning storms or when unused for long periods of time. 13 Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. For assistance visit our website www.philips.com/AVENT or call 1-800-54-AVENT (1- 800-542-8368). 14 This baby monitor is intended as an aid. It is not a substitute for responsible and proper adult supervision and should not be used as such. 15 Use this appliance only for its intended use as described in this manual. 16 Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. 17 Products should not be used while you are in a bathtub, shower or pool. Immersion of the product in water could cause an electrical shock. 18 This product should be operated only from the type of power source indicated on the type plate of the adapters (A10, B5). If you are not sure of the type of power supply to your home, consult your dealer or local power company. 19 Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock. 20 Never push objects of any kind into this product through casing slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product. 21 To reduce the risk of electric shock, do not disassemble this product, but visit our website www. philips.com/AVENT or call 1-800-54-AVENT (1-800-542-8368) for assistance. Opening or removing covers (except battery compartment lids) may expose you to dangerous voltage or other risks. Incorrect reassembly can cause electric shock when the appliance is subsequently used. 22 To prevent strangulation with power cord, never place monitor within reach of child. Do not use with extension cords. if your product utilizes batteries, the following additional precautions should be observed: 1 Use only the type and size of batteries specified in the user manual. EngliSh 2 Do not dispose of batteries in fire. They may explode. Dispose of batteries according to the instructions. 3 Exercise care in handling batteries in order not to short out the batteries with conducting materials such as rings, bracelets and keys. Overcharging, short circuiting, reverse charging, mutilation, or incineration of batteries must be avoided to prevent one or more of the following occurrences: release of toxic materials, release of hydrogen and/or oxygen gas, rise in surface temperature. 4 Do not attempt to recharge batteries provided with or identified for use with this product that are not intended to be charged. The batteries may leak corrosive electrolyte or explode. 5 Do not attempt to rejuvenate the batteries provided with or identified for use with this product by heating them. Sudden release of battery electrolyte may occur, causing burns or irritation to eyes or skin. 6 If and when necessary, the batteries must be replaced with identical new ones from the same manufacturer. If a battery to be replaced is connected with other batteries in series, it is recommended that the other batteries be replaced with new ones at the same time. 7 Reverse polarity installation of the batteries in the end product must be avoided. Reverse insertion of batteries can cause charging, and that may result in leakage or explosion. 8 Remove batteries from this product if you store the product over 30 days because the batteries could leak and damage the product. 9 Discard ‘dead’ batteries as soon as possible since ‘dead’ batteries are more likely to leak in a product. If a battery has leaked or vented, it should be replaced immediately using protective gloves. 10 Do not store batteries in high-temperature areas. Batteries that are stored in a freezer or refrigerator for the purpose of extending shelf life should be protected from condensation during storage and defrosting. Batteries should be stabilized at room temperature prior to use after cold storage. 11 If your product uses rechargeable batteries, charge the batteries only in accordance with the instructions and limitations specified in the user manual. 12 There is a risk of explosion if batteries are replaced with an incorrect type. For the parent unit, always use the SCD600 Li-Ion recha…

Text truncated - open the document above for the full version.

External Photos

CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 48 of 58 8 Photographs of t he E UT Photo 1: Parent Unit Photo 2: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 49 of 58 Photo 3: Parent Unit Photo 4: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 50 of 58 Photo 5: Parent Unit Photo 6: Parent Unit

Internal Photos

CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 51 of 58 Photo 7: Parent Unit Photo 8: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 52 of 58 Photo 9: Parent Unit Photo 10: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 53 of 58 Photo 11: Parent Unit Photo 12: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 54 of 58 Photo 13: Parent Unit Photo 14: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 55 of 58 Photo 15: Parent Unit Photo 16: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 56 of 58 Photo 17: Parent Unit Photo 18: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 57 of 58 Photo 19: Parent Unit Photo 20: Parent Unit CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 58 of 58 Photo 21: Parent Unit

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of 2009-11-27 Page 1 of 29 Accredited testing laboratory DAR registration number: DAT-P-176/94-D1 Appendix to test report 1-0951-01-10/08 Calibration data, Phantom certificate and detail information of the DASY4 System CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 2 of 29 Table of Content 1 Calibration report “Probe ET3DV6” .................................................................................................................................... 3 2 Calibration report “2450 MHz System validation dipole” ................................................................................................. 12 3 Calibration certificate of Data Aquisition Unit (DAE) ...................................................................................................... 21 4 Certificate of “SAM Twin Phantom V4.0/V4.0C” ........................................................................................................... 22 5 Application Note System Performance Check ................................................................................................................... 24 2009-11-27 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 3 of 29 1 Calibration report “Probe ET3DV6” CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 4 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 5 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 6 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 7 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 8 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 9 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 10 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 11 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 12 of 29 2 Calibration report “2450 MHz System validation dipole” CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 13 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 14 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 15 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 16 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 17 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 18 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 19 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 20 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 21 of 29 3 Calibration certificate of Data Aquisition Unit (DAE) CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 22 of 29 4 Certificate of “SAM Twin Phantom V4.0/V4.0C” CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 23 of 29 CETECOM ICT Services GmbH Calibration Data and Phantom Information to test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 24 of 29 5 Application Note System Performance Check 5.1.1.1 Purpose of system performance check The system performance check verifies that the system operates within its specifica-tions. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many param-eters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY4 incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the at section of the SAM Twin Phantom) with a well characterized source (a matched dipole at a specified distance). This setup was selected to give a high sensitivity to all parameters that might fail or vary over time (e.g., probe, liquid parameters, and software settings) and a low sensitivity to external effects inherent in the system (e.g., positioning uncertainty of the device holder). The system performance check does not replace the calibration of the components. The accuracy of the system performance check is not sufficient for calibration purposes. I…

Text truncated - open the document above for the full version.

RF Exposure Info

CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, Germany Phone: +49 (0) 681 598-0 Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of 2009-11-27 Page 1 of 34 Accredited testing laboratory DAR registration number: DAT-P-176/94-D1 Test report no. : 1-0951-01-10/08 Type identification : SCD600-R Test specification : IEEE 1528-2003 FCC-ID : BOUSCD600H IC-ID : 135M-SCD600H CETECOM ICT Services GmbH Test report no.: 1-0951-01-10/08 As of 2009-11-27 Page 2 of 34 Table of Contents 1 General Information............................................................................................................................................................... 3 1.1 Notes ............................................................................................................................................................................... 3 1.1.1 Statement of Compliance ....................................................................................................................................... 3 1.2 Testing laboratory............................................................................................................................................................ 4 1.3 Details of applicant.......................................................................................................................................................... 4 1.4 Application details........................................................................................................................................................... 4 1.5 Test item .......................................................................................................................................................................... 5 1.6 Test specification(s) ........................................................................................................................................................ 6 1.6.1 RF exposure limits ................................................................................................................................................. 6 2 Technical test ......................................................................................................................................................................... 7 2.1 Summary of test results ................................................................................................................................................... 7 2.2 Test environment ............................................................................................................................................................. 7 2.3 Measurement and test set-up ........................................................................................................................................... 7 2.4 Measurement system ....................................................................................................................................................... 8 2.4.1 System Description ................................................................................................................................................ 8 2.4.2 Test environment ................................................................................................................................................... 9 2.4.3 Probe description ................................................................................................................................................... 9 2.4.4 Phantom description ............................................................................................................................................ 10 2.4.5 Device holder description .................................................................................................................................... 10 2.4.6 Scanning procedure.............................................................................................................................................. 11 2.4.7 Spatial Peak SAR Evaluation............................................................................................................................... 12 2.4.8 Data Storage and Evaluation................................................................................................................................ 13 2.4.9 Test equipment utilized........................................................................................................................................ 15 2.4.10 Tissue simulating liquids: dielectric properties.................................................................................................... 16 2.4.11 Tissue simulating liquids: parameters.................................................................................................................. 16 2.4.12 Measurement uncertainty evaluation for SAR test .............................................................................................. 17 2.4.13 Measurement uncertainty evaluation for system validation................................................................................. 18 2.4.14 System validation................................................................................................................................................. 19 2.4.15 Validation procedure............................................................................................................................................ 20 2.5 Test results (conducted power measurement)................................................................................................................ 21 2.6 Test results (Body SAR)................................................................................................................................................ 22 Annex 1 System performance verification .................................................................................................…

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH Untertürkheimer Straße 6-10 . D-66117 Saarbrücken Phone: +49 (0) 681-598-0 Fax: -9075 RSC-Laboratory 2009-12-23 Page 1 of 58 Accredited testing-laboratory DAR registration number: DAT-P-176/94-D1 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3462C-1 (IC) Certification ID: DE 0001 Accreditation ID: DE 0002 Accredited Bluetooth ® Test Facility (BQTF) The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Cetecom ICT is under license Test report no. : 1-0951-01-03/08-B Type identification : SCD600-R Applicant : Philips Consumer Lifestyle B.V. FCC ID : BOUSCD600H IC Certification No : 135M-SCD600H Test standards : 47 CFR Part 15 RSS - 210 Issue 7 CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 2 of 58 Table of contents 1 General information.................................................................................................. 3 1.1 Notes ...................................................................................................................................................................3 1.2 Testing laboratory ...............................................................................................................................................4 1.3 Details of applicant .............................................................................................................................................4 1.4 Application details ..............................................................................................................................................4 2 Test standard/s ......................................................................................................... 5 3 Technical tests.......................................................................................................... 6 3.1 Details of manufacturer.......................................................................................................................................6 3.1.1 Test item......................................................................................................................................................6 3.1.2 Additional EUT information For IC Canada (appendix 2)..........................................................................7 3.1.3 RF Technical Brief Cover Sheet acc. To RSS-102 ............................Fehler! Textmarke nicht definiert. 3.1.4 EUT operating modes..................................................................................................................................8 3.1.5 Extreme conditions testing values ...............................................................................................................8 4 Summary of Measurement Results and list of all performed test cases ......................... 9 5 RF measurement testing .......................................................................................... 10 5.1 Description of test set-up ..................................................................................................................................10 5.1.1 Radiated measurements.............................................................................................................................10 5.1.2 Conducted measurements..........................................................................................................................10 5.2 Referenced documents ......................................................................................................................................11 5.3 Additional comments ........................................................................................................................................12 5.4 Antenna gain .....................................................................................................................................................13 5.5 Carrier frequency separation §15.247(a) (1) .....................................................................................................14 5.6 Number of hopping channels §15.247(a) (1) ....................................................................................................15 5.7 Time of occupancy (dwell time) §15.247(a)(1)(iii) ..........................................................................................16 5.8 Power Spectral density (Hybrid system in Inquiry mode/Page scan) §15.247(e) .............................................18 5.9 Spectrum Bandwidth of a FHSS System / 20dB Bandwidth §15.247(a)(1)......................................................19 5.10 Maximum output power (conducted) § 15.247 (b) (1) ..................................................................................21 5.11 Max. peak output power (radiated) § 15.247 (b)(1) ......................................................................................23 5.12 Band-edge compliance of conducted emissions §15.247 (d) ........................................................................24 5.13 Band-edge compliance of radiated emissions §15.205 .................................................................................27 5.14 Spurious Emissions - conducted (Transmitter) § 15.247 (c)(1) ....................................................................28 5.15 Spurious Emissions > 30 MHz- radiated (Transmitter) § 15.247 (c)(1)........................................................30 5.16 Spurious Emissions - radiated (Receiver) § 15.109 ......................................................................................38 5.17 Spurious Emissions < 30 MHz - Transmitter radiated § 15.209 ...................................................................41 5.18 Conducted Emissions <30 MHz § 15.107/207........................…

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 46 of 58 7 Photographs of t he Test Set- up Photo 1: Photo 2: CETECOM ICT Services GmbH Test report no.: 1-0951-01-03/08-B 2009-12-23 Page 47 of 58 Photo 3:

Contact Information

Applicant

Tee Wee Jaw(Director, Project Management)
[email protected]+85224896960Fax: +85224011482

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.47 GHz44.64 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted The highest reported SAR value is Body (touched): 0.744 W/kg

Other Applications from Philips Consumer Lifestyle

BLE Activity Monitor with OHR - FCC ID BOUDL8775 - Philips Consumer Lifestyle
BOUDL8775

BLE Activity Monitor with OHR

May 21, 2015

Equipment Class

DTS - Digital Transmission System
Activity Monitor with OHR - FCC ID BOUDL8770 - Philips Consumer Lifestyle
BOUDL8770

Activity Monitor with OHR

Sep 17, 2014

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Personal Activity Monitor with Bluetooth Function - FCC ID BOUDL8725 - Philips Consumer Lifestyle
BOUDL8725

Personal Activity Monitor with Bluetooth Function

Jul 10, 2014

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
1.9GHz DECT Baby Monitor - Baby Unit - FCC ID BOUSCD501 - Philips Consumer Lifestyle
BOUSCD501

1.9GHz DECT Baby Monitor - Baby Unit

May 28, 2014

Equipment Class

PUB - Part 15 Unlicensed PCS Base Station
1.9GHz DECT Baby Monitor - Parent Unit - FCC ID BOUSCD501H - Philips Consumer Lifestyle
BOUSCD501H

1.9GHz DECT Baby Monitor - Parent Unit

May 28, 2014

Equipment Class

PUT - Part 15 Unlicensed PCS portable Tx worn on body