FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ascom (Sweden) AB/
  3. BXZIP6000

BXZIP6000VoIP Gateway (PoE)

Ascom (Sweden) AB
VoIP Gateway (PoE) - FCC ID BXZIP6000 - Ascom (Sweden) AB
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Jan 15, 2006
Application Purpose
Original Equipment
Date of Application
Jan 15, 2006
Equipment Note
VoIP Gateway (PoE)
Company
Ascom (Sweden) AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DRAFT TD 92326GB 2005-09-13/ Ver. PA3 Installation and Operation Manual ISDN – VoIP Gateway DRAFT TD 92326GB 2005-09-13/ Ver. PA3 Installation and Operation Manual ISDN – VoIP Gateway Contents 1 Introduction............................................................................................................. 1 1.1 Channel Associated Signalling ............................................................................ 1 1.2 Requirements ..................................................................................................... 1 1.3 About this manual ............................................................................................. 1 1.3.1 Important, Notes and Tips .......................................................................... 2 2 Description............................................................................................................... 2 2.1 Connections and Indicators on the Front ............................................................ 2 2.2 Connections on the Rear Side ............................................................................ 3 2.3 Switching the Gateway On/Off .......................................................................... 3 2.4 Pin assignments for the ISDN and RS232 interfaces ............................................ 4 2.5 The MAC address/Serial number ........................................................................ 5 3 Installation............................................................................................................... 5 3.1 Installation Steps ................................................................................................ 5 3.2 Access to the Local Area Network (LAN) ............................................................. 6 3.2.1 Generating the default configuration ......................................................... 6 3.2.2 Setting the IP-interface parameters via DHCP ............................................. 6 3.2.3 Setting the IP-interface parameters without DHCP ..................................... 8 4 Configuration Information ................................................................................... 10 4.1 General ............................................................................................................ 10 4.2 Configuration Steps ......................................................................................... 10 4.3 Configuration User Interface ............................................................................ 11 4.4 Changing and Saving the Configuration .......................................................... 12 5 IP Interfaces ........................................................................................................... 13 5.1 Ethernet interface ............................................................................................ 13 5.1.1 DHCP configuration options ..................................................................... 15 5.1.2 Full duplex Ethernet ................................................................................. 15 5.1.3 Priority on Ethernet .................................................................................. 15 5.2 WAN Interfaces ................................................................................................ 16 5.2.1 General considerations on the configuration of the PPP connections ........ 18 5.2.2 Settings for outgoing ISDN PPP dial-up connections ................................. 19 5.2.3 Settings for incoming ISDN PPP dial-up connections ................................. 20 5.2.4 Settings for incoming and outgoing ISDN PPP dial-up connections ........... 21 5.2.5 Special features of WAN connections via Ethernet (PPPoE) ........................ 21 5.2.6 Settings for VPN connections with PPTP ................................................... 22 5.2.7 The remote maintenance facility in the standard configuration ................. 23 5.2.8 Allowing dial-up access to the entire network .......................................... 24 5.2.9 The ENUM protocol ................................................................................. 24 5.2.10 To set up the ENUM protocol on a VoIP gateway .................................... 25 5.2.11 Rerouting outgoing calls ........................................................................ 27 DRAFT TD 92326GB 2005-09-13/ Ver. PA3 Installation and Operation Manual ISDN – VoIP Gateway 6 ISDN Interfaces ...................................................................................................... 28 6.1 IP 6000 ISDN interfaces .................................................................................... 29 6.2 Considerations on the configuration of the ISDN interfaces .............................. 29 6.2.1 Usage at a public exchange line (dial-up or permanent connection) .......... 32 6.2.2 Usage as connection for a telephone or another piece of ISDN-terminal equipment ................................................................................................ 33 6.2.3 Use as a public exchange line for an ISDN-PBX ......................................... 35 6.2.4 Use as a subscriber to an ISDN-PBX .......................................................... 36 6.2.5 Use on a PBX tie line ................................................................................ 37 6.2.6 Looping the gateway into an existing public exchange line ....................... 39 6.2.7 Dealing with the various ISDN address types ............................................ 39 7 VoIP Interfaces....................................................................................................... 42 7.1 General considerations on the configuration of the VoIP interfaces .................. 42 7.1.1 Understanding your gateway's gatekeeper ............................................... 43 7.1.2 Gatekeeper discovery ..........................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

innovaphone AG, Böblinger Str. 76, 71065 Sindelfingen To whom it may concern  innovaphone AG Christoph KĂĽnkel Böblinger Str. 76 D71065 Sindelfingen +49 (7031) 73009 – 28 @ [email protected] http://www.innovaphone.com Âť Sindelfingen, den 2. Dezember 2005 ckl101107 Declaration of Equivalence innovaphone Gateway IP6000, original FCC ID TGC 8IP6000 This is to confirm that the equipment bearing the new FCC ID BXZIP6000 (Ascom) is identical to the original equipment and the original test results continue to be representative of and applicable to the equipment bearing the new FCC ID. Original equipment: TGC8IP6000 Equivalent equipment: BXZIP6000 Regards innovaphone i.A. Christoph KĂĽnkel innovaphone AG Böblinger Str. 76 71065 Sindelfingen Tel + 49 (70 31) 7 30 09 - 0 Fax + 49 (7031) 7 30 09 – 99 Sitz der Gesellschaft: Sindelfingen, HRB Nr.5196 Amtsgericht Böblingen Vorsitzender des Aufsichtsrates: Gebhard Michel Vorstand: Dagmar Geer (Vorsitzende) Carsten Bode, Guntram Diehl, Gerd Hornig Bankverbindung: KSK Waiblingen BLZ 602 500 10 Kto.-Nr. 7 263 778, Deutsche Bank AG Böblingen BLZ 600 700 70 Kto-Nr.: 8733065 Ust-IdNr.: DE186790876, Internet: www.innovaphone.com

Cover Letter(s)

November 29,2005 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 2 1046 Request for Confidentiality Ascom Tateco AB FCC Registration Number (FRN): 0013904214 FCC ID: BXZIP6000 FCC Part 15 Certification In accordance with 0.457 and 0.459 of CFR 47, Ascom Tateco AB hereby requests confidentiality of all: attachments for the subject application. These documents contain detailed system and equipment description and related information about the product which Ascom Tateco AB considers to be proprietary, confidential and a custom design and otherwise would not release to the general public. Since the design is a basis from which future technological products will evolve, Ascom Tateco AB considers that this information would be of benefit to its competitors and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Sincerely, Signature Name Title Company L\J& Tania Ottebrink d%ii!& Approval & Certifcation Engineer Ascom Tateco AB Ascom, Wireless Solutions PO Box 8783, SE402 76 Gothenburg, Sweden T +46 3 1 55 93 00, F +46 3 1 55 20 31 www.ascom.com~ws Org.nr./F-skatt 556336-6292, VAT No. SE556336629201, REG. Office: G~TEBORG

Cover Letter(s)

Gothenburg, 2 December 2005. Ta wham if may cancern Declaration of Equivalence Ascam Tateca hereby declare that the equipment bearing the new FCC ID BXZIP6000 is identical to the original equipment Innovaphone Gateway IP6000, FCC ID TGC81P600 Test results continue to be representative of and applicable to the equipment bearing the new FCC ID. / ( '") ~ O~itk1Ă…A, (J.AWJ Tania Ottebrink Approval & Certification Engineer R&D Department Ascom, Wireless Solutions PO Box 8783, SE402 76 Gothenburg, Sweden T +46 31 559300, F +46 31 55 2031 www.ascom.com/ws Org.nr./F-skatt 556336-6292, VAT No. SE556336629201, REG. Office: GĂ–TEBORG

Test Report

EMC Test Report No.: 06-004 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-06-004-V01.00 Page 2 of 24 Client: Innovaphone AG Böblinger Str. 76 D-71065 Sindelfingen Germany Test house: HERBERG Service Plus GmbH European Compliance Laboratory (ECL) Nordostpark 51 D-90411 Nürnberg Tel.: +49 0911 59835 91 Fax: +49 0911 59835 90 General: The purpose of the performed inspections and tests was to demonstrate that an equipment under defined environmental conditions can survive without irreversible failures and perform according to requirements. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. EMC Test Report No.: 06-004 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-06-004-V01.00 Page 3 of 24 Table of contents 1 INTRODUCTION....................................................................................................................................4 1.1 PURPOSE..........................................................................................................................................4 1.2 SUMMARY.........................................................................................................................................4 2 EQUIPMENT UNDER TEST ..................................................................................................................5 2.1 EUT DESIGNATION............................................................................................................................5 2.2 DESCRIPTION....................................................................................................................................5 2.2.1 CONNECTIONS...........................................................................................................................6 2.3 CONFIGURATION TESTED WITH ADDITIONAL EQUIPMENT.......................................................................6 2.4 OPERATING STATES...........................................................................................................................6 3 DESCRIPTION OF EMC TEST CENTRE..............................................................................................7 3.1 REGISTRATIONS................................................................................................................................7 3.2 SEMI ANECHOIC CHAMBER (SAC) WITH MAXIMUM 10M MEASUREMENT DISTANCE..................................7 3.3 FULLY ANECHOIC CHAMBER (FAC) WITH MAXIMUM 5M MEASUREMENT DISTANCE..................................8 3.4 FULLY ANECHOIC CHAMBER (FAC2) WITH MAXIMUM 3M MEASUREMENT DISTANCE................................9 3.5 SHIELDED TEST CABINS......................................................................................................................9 3.6 INSTRUMENT ROOM.........................................................................................................................11 3.7 MEASUREMENT UNCERTAINTY.........................................................................................................11 3.8 GROUND PLAN.................................................................................................................................12 4 MEASUREMENT OF EMISSION.........................................................................................................14 4.1 CONDUCTED EMISSION FROM THE POWER PORT (IN POE MODE) ........................................................14 4.1.1 SET-UP AND TEST METHOD.......................................................................................................14 4.1.2 TEST RESULTS.........................................................................................................................17 5 CALIBRATION LIST.............................................................................................................................19 6 ACCREDITATION CERTIFICATE .......................................................................................................23 EMC Test Report No.: 06-004 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-06-004-V01.00 Page 4 of 24 1 Introduction 1.1 Purpose This report documents the qualification testing for the "IP6000" system to FCC 47CFR Part 15 Subpart B Class "B". The system is referred to as the EUT from here on for the purpose of this report. All emission testing was performed per ANSI C63.4 (methods of measurement of radio-noise emissions from low- voltage electrical and electronic equipment in the range of 9 kHz to 40 GHz). 1.2 Summary The EUT met the conducted emission requirement per FCC 47CFR part 15 Subpart B for class B device. The conducted emissions were met with a minimum 2,5 dB margin. This report should be read in conjunction with the test report ECL-EMC-TR-05-125-V01.00, which contains further radiated emission and conducted emission measurement results of the IP6000. EMC Test Report No.: 06-004 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-06-004-V01.00 Page 5 of 24 2 Equipment under test 2.1 EUT designation Ascom / Innovaphone IP 6000 Ser. No.: 00-90-33-08-00-47 2.2 Description The “Innovaphone VoIP Gateway” is a powerfull and extreme stable VoIP Gateway for connection to the classic telephony using four T1(DS1) PRI interfaces. The VoIP-Gateway is available as desktop unit. At the network side, the IP 6000 has four integrated T1 interfaces. With the integrated T1 interfaces, connection to the international leased lines are possible. Technical Specification Interfaces T1 PRI 4 x TE mode for trunk interface or 2 x TE and 2 x NT to insert in trunk lines Step-by-step license regist…

Text truncated - open the document above for the full version.

Test Report

EMC Test Report No.: 05-125 FCC ID: 96997 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-05-125-V01.00 Page 2 of 33 Client: Innovaphone AG Böblinger Str. 76 D- 71065 Sindelfingen Germany Testhouse: HERBERG Service Plus GmbH European Compliance Laboratory (ECL) Nordostpark 51 D-90411 Nürnberg Tel.: +49 0911 59835 91 Fax: +49 0911 59835 90 General: The purpose of the performed inspections and tests was to demonstrate that an equipment under defined environmental conditions can survive without irreversible failures and perform according to requirements. This report informs about the results of the EMC tests, it only refers to the equipment under test. No part of this report may be reproduced in any form, without written permission. EMC Test Report No.: 05-125 FCC ID: 96997 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-05-125-V01.00 Page 3 of 33 Table of contents 1 INTRODUCTION ..............................................................................................................................4 1.1 PURPOSE....................................................................................................................................4 1.2 SUMMARY...................................................................................................................................4 2 EQUIPMENT UNDER TEST.............................................................................................................5 2.1 EUT DESIGNATION.......................................................................................................................5 2.2 DESCRIPTION...............................................................................................................................5 2.3 CONFIGURATION..........................................................................................................................6 2.3.1 CONNECTIONS......................................................................................................................7 3 DESCRIPTION OF EMC TEST CENTRE..........................................................................................8 3.1 REGISTRATIONS...........................................................................................................................8 3.2 SEMI ANECHOIC CHAMBER (SAC) W ITH MAXIMUM 10M MEASUREMENT DISTANCE................................9 3.3 FULLY ANECHOIC CHAMBER (FAC) W ITH MAXIMUM 5M MEASUREMENT DISTANCE...............................10 3.4 FULLY ANECHOIC CHAMBER (FAC2) W ITH MAXIMUM 3M MEASUREMENT DISTANCE.............................11 3.5 FULLY ANECHOIC CHAMBER (STRIPLINE) .......................................................................................12 3.6 SHIELDED TEST CABINS...............................................................................................................13 3.7 INSTRUMENT ROOM....................................................................................................................14 3.8 MEASUREMENT UNCERTAINTY.....................................................................................................15 3.9 GROUND PLAN...........................................................................................................................16 MEASUREMENT OF EMISSION ...........................................................................................................18 3.10 ELECTRIC FIELD RADIATED EMISSION IN THE FREQUENCY RANGE 30 MHZ - 1 GHZ.........................18 3.10.1 SET-UP AND TEST METHOD...................................................................................................18 3.10.2 TEST RESULTS....................................................................................................................20 3.11 CONDUCTED EMISSION FROM THE POWER PORT.........................................................................22 3.11.1 SET-UP AND TEST METHOD...................................................................................................22 3.11.2 TEST RESULTS....................................................................................................................25 4 CALIBRATION LIST........................................................................................................................28 5 ACCREDITATION CERTIFICATE ................................................................................................... 32 EMC Test Report No.: 05-125 FCC ID: 96997 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-05-125-V01.00 Page 4 of 33 1 Introduction 1.1 Purpose This report documents the qualification testing for the IP 6000 system to FCC 47CFR Part 15 Subpart B Class "B". The system is referred to as the EUT from here on for the purpose of this report. All emission testing was performed per ANSI C63.4 (methods of measurement of radio-noise emissions from low- voltage electrical and electronic equipment in the range of 9 kHz to 40 GHz). 1.2 Summary The EUT met the emission requirement per FCC 47CFR part 15 Subpart B for class B computing device. The radiated emissions were met with the EUT configured as stated here in this report with a minimum 0,5 dB margin below the specified limits. The conducted emissions met with a minimum 7dB margin. EMC Test Report No.: 05-125 FCC ID: 96997 The test report shall not be reproduced except in full without the written approval of the testing laboratory. ECL-EMC-TR-05-125-V01.00 Page 5 of 33 2 Equipment under test 2.1 EUT designation IP 6000 2.2 Description classic telephony using four T1(DS1) PRI interfaces. The VoIP-Gateway is available as desktop unit. At the network side, the IP 6000 has four integrated T1 interfaces. With the integrated T1 interfaces, connection to the international leased lines are possible. .…

Text truncated - open the document above for the full version.

Test Setup Photos

IP 6000

Contact Information

Applicant

Peter Soderberg
[email protected]004631559579Fax: +46 31 552031

Test Firm

Bureau Veritas Consumer Products Services GermanyMario Lehmann
[email protected]49-40-74041-2702Fax: 49-175-575-4778

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term

Other Applications from Ascom (Sweden) AB

Narrow band alarm transceiver - FCC ID BXZCHAT2 - Ascom (Sweden) AB
BXZCHAT2

Narrow band alarm transceiver

Sep 27, 2023

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Myco 4 WiFi, Myco 4 Slim - FCC ID BXZSH4 - Ascom (Sweden) AB
BXZSH4

Myco 4 WiFi, Myco 4 Slim

Aug 02, 2023

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
DECT Handset with Bluetooth - FCC ID BXZDH9 - Ascom (Sweden) AB
BXZDH9

DECT Handset with Bluetooth

Apr 16, 2023

Equipment Class

PUE - Part 15 Unlicensed PCS portable Tx held to ear
DECT Handset with Bluetooth - FCC ID BXZDH10 - Ascom (Sweden) AB
BXZDH10

DECT Handset with Bluetooth

Apr 16, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
DECT Handset with Bluetooth and BLE - FCC ID BXZDH8 - Ascom (Sweden) AB
BXZDH8

DECT Handset with Bluetooth and BLE

Aug 09, 2021

Equipment Class

JAB - Part 15 Class B Digital Device