FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hyundai Electronics Industries Co Ltd/
  3. CKLHGP-2200E

CKLHGP-2200ESINGLE BAND PCS CDMA PHONE

Hyundai Electronics Industries Co Ltd
SINGLE BAND PCS CDMA PHONE - FCC ID CKLHGP-2200E - Hyundai Electronics Industries Co Ltd
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Mar 25, 1999
Application Purpose
Original Equipment
Date of Application
Feb 15, 1999
Equipment Note
SINGLE BAND PCS CDMA PHONE
Frequency Range
1851.25000000 - 1908.75000000
Company
Hyundai Electronics Industries Co Ltd
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

l HYUNDAI HYUNDAI ELECTRONICS IND. CO., LTD Quality Assurance Off ice Quality Assistance De P t. San 136-1, Ami-Ri, Buba -Eub, Ichon-Si Kyoungki-Do, 467-jO1, Korea Date : JUNE 10, 1998 Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 U.S.A. In re : Hyundai Electronics Industries Co., Ltd. FCC ID : CKLHGP-2000E PCS CDMA Phone Part 24Certification Request for Confidentialy Gentlemen : I n accordance with 0.459 of CFR 47, Hyundai Electronics Industries Co., Ltd. hereby requests confidentiality of the Block Diagrams attachment, Schematic Diagrams attachment, Operational Description attachment, Part List/Tune Up Procedure attachment and Antenna Specifications for the above referenced application These documents contain detailed system and equipment description and related information about the product which Hyundai Electronics Industries Co., Ltd. considers to be proprietary,confidential, and a custom design and, otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, Hyundai Electronics Industries Co., Ltd. feels this information would be of benefit to its competitors, and that the discloure of the information in these documents would give our competitors an unfair advantage in the market. Sincerely Yours, c, +Y ________ ____________________~~~~~~~~~~~~~~ Chang Hee, Ji General Manager of QA Office Hyundai Electronics Ind. Co., Ltd.

Cover Letter(s)

February 16, 1999 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT:HYUNDAI Electronics Industries Co., Ltd. FCC ID: CKLHGP-2200E Part 24 Certification Gentlemen: Attached herewith, on behalf of HYUNDAI Electronics Industries Co., Ltd., is an application for Part 24 Certification of the following single-band PCS CDMA phone: FCC ID:CKLHGP-2200E TRADE / MODEL(s):HYUNDAI HGP-2200E EUT TYPE:Single-Band PCS CDMA Phone (PCE) Tx Freq. Range:1851.25 – 1908.75 MHz Max. Output Power:0.3 Watts (EIRP) Attached is the applicant’s Letter of Authorization, Confidentiality Request, measurement report data and plots, RF Exposure measurement report, FCC ID label and location, test setup photographs, internal and external photographs, block diagrams (confidential), schematic diagrams (confidential), operational description (confidential), parts list & tune-up procedure (confidential), and the user's manual. Should you have any questions or comments concerning the above, please contact the undersigned. cc:Mr. Ki-Soo Kim Section Chief, QA Office HYUNDAI Electronics Industries Co., Ltd.

External Photos

Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E)

ID Label/Location Info

© 1999 PCTEST Lab FCC ID SAMPLE LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. Fig 12. Sample label (SEE NEXT PAGE)

Internal Photos

Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E)

RF Exposure Info

© 1999 PCTEST Engineering Lab., Inc. PCTEST Engineering Laboratory, Inc. 6660-B 6660-B DobbinDobbin Road Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290-6652 TEL (410) 290-6652 •• FAX (410) 290-6654 FAX (410) 290-6654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE (SAR EVALUATION) HYUNDAI Electronics Industries Co., Ltd.Dates of Tests: February 08-12, 1999 136-1, Ami-Ri, Bubal-EubTest Report S/N: SAR.990119028.CKL Ichon-Si, Kyoungki-Do, KOREA 467-701Test Site: PCTEST Lab, Columbia MD Attention: Mr. Ki-Soo Kim, Section Chief, QA Office FCC ID CKLHGP-2200E APPLICANT HYUNDAI Electronics Industries Co., Ltd. EUT Type:Single-Band PCS CDMA Phone Tx Frequency:1851.25 – 1908.75 MHz Rx Frequency:1931.25 – 1988.75 MHz Max Output Power:0.2 W (Conducted) Trade Name:HYUNDAI Model(s):HGP-2200E FCC Classification:Licensed Portable Transmitter Held to Ear (PCE) Application Type:Certification Serial Number:n/a (pre production) FCC Rule Part(s):2.1093; ET Docket 96.326; 24(E) This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1992. (See Test Report). I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. NVLAP accreditation does not constitute any product endorsement by NVLAP or any agency of the United States Government. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a) 990119028.CKL SAR Measurement ReportFCC Part 24 Certification © 1999 PCTEST Labi Table of Contents SCOPE .............................................................................1 INTRODUCTION / SAR DEFINITION ......................................2 SAR MEASUREMENT SET-UP .............................................3 E-FIELD PROBE SYSTEM ...................................................4 PHANTOM & BRAIN EQUIVALENT MATERIAL ......................7 SYSTEM SPECIFICATIONS ................................................. 8 MEASUREMENT PROCESS ................................................9 TEST POSITION OF THE PHONE .........................................10 ANSI/IEEE C95.1 RF EXPOSURE LIMITS ..............................11 MEASUREMENT UNCERTAINTIES ......................................12 TEST DATA SUMMARY ...................................................... 13 SAR TEST EQUIPMENT LIST .............................................. 14 CONCLUSION / REFERENCES ...........................................15 Test Report S/N: SAR.990119028.CKLSAR Measurement Report Test Dates: February 08-12, 1999FCC Part 24 Certification FCC ID: CKLHGP-2200E (Tx 1851.25 – 1908.75 MHz) © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone1 SAR MEASUREMENT REPORT Scope - Environmental evaluation measurements of specific absorption rate 1 (SAR) distributions in simulated human head tissues exposed to radiofrequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 2 Company Name:HYUNDAI Electronics Industries Co., Ltd. ADDRESS :136-1, Ami-Ri, Bubal-Eub Ichon-Si, Kyoungki-Do, KOREA 467-701 Attention :Ki-Soo Kim, Section Chief, QA Office • EUT Type:Single-Band PCS CDMA Phone • FCC IDENTIFIER:CKLHGP-2200E • Trade Name:HYUNDAI • Model:HGP-2200E • S/N:Pre-production • Tx Frequency Range:1851.25 – 1908.75 MHz • Rx Frequency Range:1931.25 – 1988.75 MHz • Application Type: Certification • FCC Classification:Licensed Portable Transmitter Held to Ear (PCE) • FCC Rule Part(s):§ 24(E); § 2.1093, Docket 96-326 • Max. Output Power:0.2 W (Conducted) • Modulation :CDMA • Antenna:Helical (3/4λ) • Antenna Dimensions:14.4 cm. (Length) • Dates of Test(s):February 08-12, 1999 • Place of Test(s):PCTEST Engineering Lab. Columbia, MD, U.S.A. • Report Serial No.:SAR.990119028.CKL 1 Specific Absorption Rate (SAR) is a measure of the rate of energy absorption due to exposure to an RF transmitting source (wireless portable device). 2 IEEE/ANSI Std. C95.1-1992 limits are used to determine compliance with FCC ET-Docket 93-62. Lab Code 100431-0 Figure 1. SAR Test Set-up Test Report S/N: SAR.990119028.CKLSAR Measurement Report Test Dates: February 08-12, 1999FCC Part 24 Certification FCC ID: CKLHGP-2200E (Tx 1851.25 – 1908.75 MHz) © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone2 1.1 INTRODUCTION The FCC has adopted the guidelines for evaluating the environmental effects of radiofrequency radiation in ET Docket 93-62 on Aug. 6, 1996 to protect the public and workers from the potential hazards of RF emissions due to FCC-regulated portable devices.[1] The safety limits used for the environmental evaluation measurements are based on the criteria published by the American National Standards Institute (ANSI) for localized specific absorption rate (SAR) in IEEE/ANSI C95.1-1992 Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. (c) 1992 by the Institute of Electrical and Electronics Engineers, Inc., New York, New York 10017.[2] The measurement procedure described in IEEE/ANSI C95.3-1992 Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields - RF and Microwave[3] is used for guidance in measuring SAR due to the RF radiation exposure from the Equipment Under Test (EUT). These criteria for SAR evaluation are similar to those recommended by the National Council on Radiation Protection and Measurements (NCRP) in Biologica…

Text truncated - open the document above for the full version.

RF Exposure Info

File : c:/idx3/SYSTEM/SARMEAS3/data/Normal/99020817_ZOOM.VLT Start : 8-Feb-99 05:12:46 pm End : 8-Feb-99 05:25:57 pm Radio Type : HYUNDAI Model Number : CKLHGC-2200E Serial Number : 002 Frequency : 1851.25 MHz Peak Trans. Pwr : 0.200 W Start Trans. Pwr: 0.200 W Antenna Type : Helical Antenna Posn. : In Phantom Type : Head Phantom Posn. : Left Ear Scan Type : ZOOM/SAR Probe Name : PCTEST Field Type : E Field Orientation : 0 Degrees Mixture Type = Brain Mixture Dielectric Constant = 42.900 Mixture Conductivity = 1.650 Comment : HYUNDAI PCS/CDMA PHONE CHANNEL 0025 PCS MODE PCTEST Robot : PCTEST Probe Offset = 0.25 cm Sensor Factor = 0.0108 Conversion Factor = 1.200 PCTEST Amplifier Channel Settings : 0.250 0.233 0.225 Max Location : X = 2.000, Y = -0.500, Z = 0.000 (cm) Value = 12.317 Measured Values (volts) = 1.186E-002 7.961E-003 5.669E-003 3.997E-003 2.918E-003 2.127E-003 1.608E-003 1.224E-003 9.136E-004 6.491E-004 5.240E-004 3.467E-004 2.596E-004 1.626E-004 1.569E-004 8.210E-005 1.399E-004 6.034E-005 4.753E-005 4.036E-005 1.281E-005 Calc. Voltage @ Surface (Vs) = 0.0172 Voltage @ 1.00 cm (Vt) = 0.0040 Ave. Voltage (Vs+Vt)/2 = 0.0106 Ave. SAR over 1 g (mW/g) = 1.1758 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 mW/g -1012345 Z centimeters SAR Scan File : 99020817_ZOOM Start : 8-Feb-99 05:12:46 pm End : 8-Feb-99 05:25:57 pm HYUNDAI/CKLHGC-2200E/002;1851.25MHz;W;Helical/In; Head/Left Ear;ZOOM/SAR;PCTEST/E Field/0 DegreesBrain/42.900/1.650 File : 99020817_ZOOM Start : 8-Feb-99 05:12:46 pm End : 8-Feb-99 05:25:57 pm HYUNDAI/CKLHGC-2200E/002;1851.25MHz;W;Helical/In; Head/Left Ear;ZOOM/SAR;PCTEST/E Field/0 DegreesBrain/42.900/1.650 1.369 1.288 1.206 1.125 1.044 0.963 0.882 0.801 0.720 0.639 File : 99020817_ZOOM Start : 8-Feb-99 05:12:46 pm End : 8-Feb-99 05:25:57 pm HYUNDAI/CKLHGC-2200E/002;1851.25MHz;W;Helical/In; Head/Left Ear;ZOOM/SAR;PCTEST/E Field/0 DegreesBrain/42.900/1.650 1.369 1.288 1.206 1.125 1.044 0.963 0.882 0.801 0.720 0.639 File : c:/idx3/SYSTEM/SARMEAS3/data/Normal/99020822_ZOOM.VLT Start : 08-Feb-99 11:10:32 am End : 08-Feb-98 11:16:56 am Radio Type : HYUNDAI Model Number : CKLHGC-2200E Serial Number : 002 Frequency : 1851.25 MHz Peak Trans. Pwr : 0.200 W Start Trans. Pwr: 0.200 W Antenna Type : Helical Antenna Posn. : Out Phantom Type : Head Phantom Posn. : Left Ear Scan Type : ZOOM/SAR Probe Name : PCTEST Field Type : E Field Orientation : 0 Degrees Mixture Type = Brain Mixture Dielectric Constant = 42.900 Mixture Conductivity = 1.650 Comment : HYUNDAI PCS/CDMA PHONE CHANNEL 0025 PCS MODE PCTEST Robot : PCTEST Probe Offset = 0.25 cm Sensor Factor = 0.0108 Conversion Factor = 1.200 PCTEST Amplifier Channel Settings : 0.250 0.233 0.225 Max Location : X = 4.750, Y = -4.000, Z = 0.000 (cm) Value = 10.740 Measured Values (volts) = 1.017E-002 9.781E-003 8.165E-003 6.146E-003 4.637E-003 3.543E-003 2.729E-003 2.222E-003 1.694E-003 1.264E-003 1.009E-003 7.671E-004 5.291E-004 4.401E-004 3.889E-004 2.753E-004 2.294E-004 1.802E-004 1.607E-004 1.383E-004 1.157E-004 Calc. Voltage @ Surface (Vs) = 0.0114 Voltage @ 1.00 cm (Vt) = 0.0061 Ave. Voltage (Vs+Vt)/2 = 0.0088 Ave. SAR over 1 g (mW/g) = 0.9742 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 mW/g -1012345 Z centimeters SAR Scan File : 99020822_ZOOM Start : 08-Feb-99 11:10:32 am End : 08-Feb-99 11:16:56 am HYUNDAI/CKLHGC-2200E/002;835MHz;W;Helical/Out; Head/Left Ear;ZOOM/SAR;PCTEST/E Field/0 DegreesBrain/42.900/1.650 File : c:/idx3/SYSTEM/SARMEAS3/data/Normal/99020816_ZOOM.VLT Start : 8-Feb-99 05:00:15 pm End : 8-Feb-99 05:10:43 pm Radio Type : HYUNDAI Model Number : CKLHGC-2200E Serial Number : 002 Frequency : 1880.00 MHz Peak Trans. Pwr : 0.200 W Start Trans. Pwr: 0.200 W Antenna Type : Helical Antenna Posn. : In Phantom Type : Head Phantom Posn. : Left Ear Scan Type : ZOOM/SAR Probe Name : PCTEST Field Type : E Field Orientation : 0 Degrees Mixture Type = Brain Mixture Dielectric Constant = 42.900 Mixture Conductivity = 1.650 Comment : HYUNDAI PCS/CDMA PHONE CHANNEL 600 PCS MODE PCTEST Robot : PCTEST Probe Offset = 0.25 cm Sensor Factor = 0.0108 Conversion Factor = 1.200 PCTEST Amplifier Channel Settings : 0.250 0.233 0.225 Max Location : X = 1.750, Y = -0.500, Z = 0.000 (cm) Value = 13.916 Measured Values (volts) = 1.053E-002 7.393E-003 5.209E-003 3.740E-003 2.749E-003 2.053E-003 1.495E-003 1.064E-003 7.569E-004 5.758E-004 4.305E-004 2.880E-004 2.158E-004 1.591E-004 2.617E-004 9.949E-005 2.112E-005 6.194E-005 4.381E-005 3.075E-005 2.506E-005 Calc. Voltage @ Surface (Vs) = 0.0150 Voltage @ 1.00 cm (Vt) = 0.0037 Ave. Voltage (Vs+Vt)/2 = 0.0094 Ave. SAR over 1 g (mW/g) = 1.0399 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 mW/g -1012345 Z centimeters SAR Scan File : 99020816_ZOOM Start : 8-Feb-99 05:00:15 pm End : 8-Feb-99 05:10:43 pm HYUNDAI/CKLHGC-2200E/002;1880.00MHz;W;Helical/In; Head/Left Ear;ZOOM/SAR;PCTEST/E Field/0 DegreesBrain/42.900/1.650 File : c:/idx3/SYSTEM/SARMEAS3/data/Normal/99020823_ZOOM.VLT Start : 08-Feb-99 02:23:16 pm End : 08-Feb-99 02:27:50 pm Radio Type : HYUNDAI Model Number : CKLHGC-2200E Serial Number : 002 Frequency : 1880 MHz Peak Trans. Pwr : 0.200 W Start Trans. Pwr: 0.200 W Antenna Type : Helical Antenna Posn. : Out Phantom Type : Head Phantom Posn. : Left Ear Scan Type : ZOOM/SAR Probe Name : PCTEST Field Type : E Field Orientation : 0 Degrees Mixture Type = Brain Mixture Dielectric Constant = 42.900 Mixture Conductivity = 1.650 Comment : HYUNDAI PCS/CDMA PHONE CHANNEL 0600 PCS MODE PCTEST Robot : PCTEST Probe Offset = 0.25 cm Sensor Factor = 0.0108 Conversion Factor = 1.200 PCTEST Amplifier Channel Settings : 0.250 0.233 0.225 Max Location : X = 5.750, Y = -4.000, Z = 0.000 (cm) Value = 9.824 Measured Values (volts) = 9.720E-003 7.984E-003 6.124E-003 4.762E-003 3.639E-003 2.834E-003 2.245E-003 1.663E-003 1.230E-003 9.421E-004 7.295E-004 5.454E-004 4.271E-004 2.980E-004 2.038E-004 1.172E-004 9.316E-005 9.089E-005 7.151E-005 4.109E-005 2.490E-005 Calc. Voltage @ Surface (Vs) = 0.0123 Voltage @ 1.00 cm (Vt) = 0.0048 Ave. Volta…

Text truncated - open the document above for the full version.

RF Exposure Info

Test Report S/N: SAR.990119028.CKLSAR Measurement Report Test Date(s): February 08-12, 1999FCC Part 24 Certification © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-2200E (Tx 1851.25-1908.75) Test Report S/N: SAR.990119028.CKLSAR Measurement Report Test Date(s): February 08-12, 1999FCC Part 24 Certification © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-2200E (Tx 1851.25-1908.75) Test Report S/N: SAR.990119028.CKLSAR Measurement Report Test Date(s): February 08-12, 1999FCC Part 24 Certification © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-2200E (Tx 1851.25-1908.75) Test Report S/N: SAR.990119028.CKLSAR Measurement Report Test Date(s): February 08-12, 1999FCC Part 24 Certification © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-2200E (Tx 1851.25-1908.75) Test Report S/N: SAR.990119028.CKLSAR Measurement Report Test Date(s): February 08-12, 1999FCC Part 24 Certification © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-2200E (Tx 1851.25-1908.75)

Test Report

© 1999 PCTEST Engineering Lab., Inc. PCTEST Engineering Laboratory, Inc. 6660-B 6660-B DobbinDobbin Road Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290-6652 TEL (410) 290-6652 •• FAX (410) 290-6654 FAX (410) 290-6654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE (Part 24 Certification) HYUNDAI Electronics Industries Co., Ltd.Dates of Tests: February 08-12, 1999 San 136-1, Ami-Ri, Bubal-EubTest Report S/N: 24.990119027.CKL Ichon-Si, Kyoungki-Do, KOREA 467-701Test Site: PCTEST Lab, Columbia MD U.S.A. Attn: Mr. Ki-Soo Kim, Section Chief, QA Office FCC ID CKLHGP-2200E APPLICANT HYUNDAI ELECTRONICS CO., LTD. Classification:Licensed Portable Transmitter Held to Ear (PCE) FCC Rule Part(s):§§§§24(E), 2.983, 2.987 EUT Type:Single-Band PCS CDMA Phone Trade Name/Model(s):HYUNDAI HGP-2200E Frequency Range:Tx: 1851.25 – 1908.75MHz Rx: 1931.25 – 1988.75MHz Max Output Power:0.3 Watts (EIRP) Frequency Tolerance:0.00025% (2.5 ppm) This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in §2.947 with the following remarks (Note Codes): * (BC) The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a) 990119027.CKL Certification © 1999PCTEST Engineering Laboratory, Inc.FCC Part 24 TABLE OF CONTENTS ATTACHMENT A: COVER LETTER(S) ATTACHMENT B: ATTESTATION STATEMENT(S) ATTACHMENT C: TEST REPORT SCOPE 1 INTRODUCTION (SITE DESCRIPTION) 2 INSERTS PER §2.983 3 DESCRIPTION OF TESTS 4-6 TEST DATA (RADIATED) 7-9 TEST DATA (FREQUENCY STABILITY) 10-11 PLOTS OF EMISSIONS 12 LIST OF TEST EQUIPMENT 13 SAMPLE CALCULATIONS 14 RECOMMENDATION / CONCLUSION 15 ATTACHMENT D: TEST PLOTS ATTACHMENT E: FCC ID LABEL / LOCATION ATTACHMENT F: TEST SETUP PHOTOGRAPHS ATTACHMENT G: EXTERNAL PHOTOGRAPHS ATTACHMENT H: INTERNAL PHOTOGRAPHS ATTACHMENT I: BLOCK DIAGRAM(S) ATTACHMENT J: SCHEMATIC DIAGRAM(S) ATTACHMENT K: PARTS LIST/TUNE UP PROCEDURE ATTACHMENT L:OPERATIONAL DESCRIPTION ATTACHMENT M:USER’S MANUAL ATTACHMENT N:SAR MEASUREMENT REPORT ATTACHMENT O: SAR TEST DATA ATTACHMENT P:SAR TEST SETUP PHOTOGRAPHS Test Report S/N: 24.990119027.CKLFCC Part 24 Dates of Tests: February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25 – 1908.75 MHz)1 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) MEASUREMENT REPORT Scope – Product Evaluation and determination of electromagnetic emissions (EME) of radio frequency devices including intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal Communications Commission. §2983(a) General Information Applicant Name:HYUNDAI Electronics Industries Co., Ltd. Address:San 136-1, Ami-Ri, Bubal-Eub Ichon-Si, Kyoungki-Do, KOREA 467-701 Attention:Mr. Ki-Soo Kim, Section Chief, QA Office • §2983(b) FCC ID:CKLHGP-2200E • Trade Name(s):HYUNDAI • Model(s):HGP-2200E • §2983(c) Quantity:Quantity production is planned • §2.983(d) Emission Designator:1M25F9W • §2.983(d) Maximum Power Rating:0.3 W (EIRP) • Power Supply Battery:7.2 VDC mAh Li-Ion Model: HBT-2100L • AC Power Adapter:8.2V 750mA HYUNDAI Model: HTC-2000 • FCC Classification:Licensed Portable Tx Held to Ear (PCE) • Equipment (EUT) Type:Single-Band PCS CDMA Phone • FCC Rule Part(s):§§§ 24(E), 2.983, 2.987 • Application Type:Certification • Modulation:CDMA • Tx Frequency Range: 1851.25 – 1908.75 MHz • Rx Frequency Range:1931.25 – 1988.75 MHz • Frequency Tolerance:± 2.5 ppm • Dates of Tests:February 08-12, 1999 • Place of Tests:PCTEST Lab, Colubmia, MD U.S.A. 990119027.CKL Test Report S/N: 24.990119027.CKLFCC Part 24 Dates of Tests: February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25 – 1908.75 MHz)2 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) 1.1 INTRODUCTION These measurement tests were conducted at PCTEST Engineering Laboratory, Inc. facility in New Concept Business Park, Guilford Industrial Park, Columbia, Maryland. The site address is 6660-B Dobbin Road, Columbia, MD 21045. The test site is one of the highest points in the Columbia area with an elevation of 390 feet above mean sea level. The site coordinates are 39° 11'15" N latitude and 76° 49'38" W longitude. The facility is 1.5 miles North of the FCC laboratory, and the ambient signal and ambient signal strength are approximately equal to those of the FCC laboratory. There are no FM or TV transmitters within 15 miles of the site. The detailed description of the measurement facility was found to be in compliance with the requirements of § 2.948 according to ANSI C63.4 on October 19, 1992. PCTEST Lab is recognized under the National Voluntary Laboratory Accreditation Program for satisfactory compliance with criteria established in Title 15, Part 285 Code of Federal Regulations. These criteria encompass the requirements of ISO/IEC Guide 25 and the relevant requirements of ISO 9002 (ANSI/ASQC Q92-1987) as suppliers of calibration or test results. The Scope of PCTEST Accreditation are for Electromagnetic Compatibility and Telecommunications and FCC. 1.2 PCTEST Location The map at right shows the location of the PCTEST Lab, its proximity to the FCC Lab, the Columbia vicinity area, the Baltimore- Washington International (BWI) airport, and the city of Baltimore, and the Washington, D.C. area. (see Figure1). Figure 1. Map of the Greater Baltimore and Metropolitan Was…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E) Test Report S/N: SAR.990119027.CKLFCC Part 24 Test Date(s): February 08-12, 1999Certification © 1999 PCTEST LabFCC ID: CKLHGP-2200E (Tx 1851.25-1908.75 MHz.) NVLAP Lab Code: 100431-0 HYUNDAI Single-Band PCS CDMA Phone (Model: HGP-2200E)

Contact Information

Applicant

Bong Jae Hur(Manager, QA Office)
[email protected]82 336-30-3280Fax: 82 336-3003265

Technical Contact

PCTEST ENGINEERING LABORATORY, INC.RANDY ORTANEZ
[email protected]301-596-2120

6660-B DOBBIN ROAD · COLUMBIA, Maryland · United States

Non-Technical Contact

PCTEST ENGINEERING LABORATORY, INC.RANDY ORTANEZ
[email protected]301-596-2120

Test Firm

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652Fax: 410-290-6654

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz300.00 mW1M25F9W2.5000000000 ppm
Confidentiality
Long Term

Other Applications from Hyundai Electronics Industries Co Ltd

Single-Mode Cellular CDMA WLL Terminal - FCC ID CKLHWP-120 - Hyundai Electronics Industries Co Ltd
CKLHWP-120

Single-Mode Cellular CDMA WLL Terminal

Feb 15, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Tri-Mode Dual Band Analog/PCS Phone (AMPS/CDMA) - FCC ID CKLTX-20B - Hyundai Electronics Industries Co Ltd
CKLTX-20B

Tri-Mode Dual Band Analog/PCS Phone (AMPS/CDMA)

Jan 28, 2001

Equipment Class

PCE - PCS Licensed Transmitter held to ear
CKLA526

15-inch Color Monitor

Dec 28, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CKLC21R05110

21-inch Color Monitor

Dec 28, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
17" CRT MONITOR - FCC ID CKLC17F06090 - Hyundai Electronics Industries Co Ltd
CKLC17F06090

17" CRT MONITOR

Dec 21, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral