December 07, 1999 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: HYUNDAI Electronics Industries Co., Ltd. FCC ID: CKLHGP-3000E Part 24 Certification Gentlemen: Attached herewith, on behalf of HYUNDAI Electronics Industries Co., Ltd., is an application for Part 24 Certification of the following single-band PCS CDMA phone: FCC ID: CKLHGP-3000E TRADE / MODEL(s): HYUNDAI HGP-3000E EUT TYPE: Single-Band PCS CDMA Phone (PCE) Tx Freq. Range: 1851.25 – 1908.75 MHz Max. RF Output Power: 0.35 Watts (EIRP) Attached is the applicant’s Letter of Authorization, Confidentiality Request, measurement report data and plots, RF Exposure measurement report, FCC ID label and location, test setup photographs, internal and external photographs, block diagrams (confidential), schematic diagrams (confidential), operational description (confidential), parts list & tune-up procedure (confidential), and the user's manual. Should you have any questions or comments concerning the above, please contact the undersigned. cc: Mr. Ja Beom Koo, Quality Management Dept. System Quality Assurance Office HYUNDAI Electronics Industries Co., Ltd.
Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz)
© 1999 PCTEST Lab FCC ID SAMPLE LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. (SEE NEXT PAGE)
Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov.29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz)
© 1999 PCTEST Engineering Lab., Inc. PCTEST Engineering Laboratory, Inc. 6660-B 6660-B DobbinDobbin Road Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290-6652 TEL (410) 290-6652 •• FAX (410) 290-6654 FAX (410) 290-6654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE (SAR EVALUATION) HYUNDAI Electronics Industries Co., Ltd.Date(s) of Tests: Nov. 29 - Dec. 03, 1999 San 136-1, Ami-Ri, Bubal-EubTest Report S/N: SAR.991129630.CKL Ichon-Si, Kyungki-Do, Korea 467-701Test Site: PCTEST Lab, Columbia, MD USA Attn: Mr. Ja Beom Koo Quality Management Dept. System Quality Assurance Office FCC ID CKLHGP-3000E APPLICANT HYUNDAI Electronics Industries Co., Ltd. EUT Type:Single-Band PCS CDMA Phone Tx Frequency:1851.25 – 1908.75 MHz Rx Frequency:1931.25 – 1988.75 MHz Max. RF Output Power:0.35 W EIRP Trade Name/Model(s):HYUNDAI HGP-3000E FCC Classification:Licensed Portable Transmitter Held to Ear (PCE) Application Type:Certification Serial Number:n/a (pre production) FCC Rule Part(s):2.1093; ET Docket 96.326; 24(E) This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1992. (See Test Report). I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. NVLAP accreditation does not constitute any product endorsement by NVLAP or any agency of the United States Government. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a) 991129630.CKL FCC Part 24 Certification PCTEST Engineering Laboratory, Inc.i Table of Contents SCOPE 1 INTRODUCTION / SAR DEFINITION 2 SAR MEASUREMENT SET-UP 3 E-FIELD PROBE SYSTEM 4 E-FIELD PROBE CALIBRATION PROCESS 5 DATA EXTRAPOLATION 6 PHANTOM & EQUIVALENT TISSUE 7 SYSTEM SPECIFICATIONS 8 MEASUREMENT PROCESS 9 TEST POSITION OF THE PHONE 10 BODY-WORN CONFIGURATION11 ANSI/IEEE C95.1 RF EXPOSURE LIMITS 12 MEASUREMENT UNCERTAINTIES 13 TEST DATA SUMMARY 14 BODY-WORN TEST DATA SUMMARY15 SAR TEST EQUIPMENT LIST 16 CONCLUSION 17 REFERENCES 18 Test Report S/N: SAR.991129630.CKLSAR Measurement Report Test Date(s): Nov. 29 - Dec. 03, 1999FCC Part 24 Certification FCC ID: CKLHGP-3000E (Tx 1851.25 – 1908.75 MHz) © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone1 SAR MEASUREMENT REPORT 1.1 Scope Environmental evaluation measurements of specific absorption rate 1 (SAR) distributions in simulated human head & body tissues exposed to radiofrequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 2 Company Name:HYUNDAI Electronics Industries Co., Ltd. Address:San 136-1, Ami-Ri, Bubal-Eub Ichon-Si, Kyungki-Do, KOREA 467-701 Attention:Mr. Ja Beom Koo Quality Management Dept. System Quality Assurance Office • EUT Type:Single-Band PCS CDMA Phone • Trade Name:HYUNDAI • Model(s):HGP-3000E • FCC IDENTIFIER:CKLHGP-3000E • S/N:Pre-production • Tx Frequency:1851-25 – 1908.75 MHz • Rx Frequency:1931.25 – 1988.75 MHz • Application Type: Certification • FCC Classification:Licensed Portable Transmitter Held to Ear (PCE) • FCC Rule Part(s):§ 2.1093, Docket 96-326; § 24(E) • Modulation(s):CDMA • Max RF. Output Power:0.35 W EIRP • Antenna Type:Helical (λ/2) • Antenna Dimensions:7.6cm. (Length) • Date(s) of Tests:Nov. 29 - Dec. 03, 1999 • Place of Tests:PCTEST Engineering Lab. Columbia, MD, U.S.A. • Report Serial No.:SAR.991129630.CKL 1 Specific Absorption Rate (SAR) is a measure of the rate of energy absorption due to exposure to an RF transmitting source (wireless portable device). 2 IEEE/ANSI Std. C95.1-1992 limits are used to determine compliance with FCC ET Docket 93-62. Fig. 1 SAR Test Setup Test Report S/N: SAR.991129630.CKLSAR Measurement Report Test Date(s): Nov. 29 - Dec. 03, 1999FCC Part 24 Certification FCC ID: CKLHGP-3000E (Tx 1851.25 – 1908.75 MHz) © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone2 2.1 INTRODUCTION The FCC has adopted the guidelines for evaluating the environmental effects of radiofrequency radiation in ET Docket 93-62 on Aug. 6, 1996 to protect the public and workers from the potential hazards of RF emissions due to FCC-regulated portable devices.[1] The safety limits used for the environmental evaluation measurements are based on the criteria published by the American National Standards Institute (ANSI) for localized specific absorption rate (SAR) in IEEE/ANSI C95.1-1992 Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. (c) 1992 by the Institute of Electrical and Electronics Engineers, Inc., New York, New York 10017.[2] The measurement procedure described in IEEE/ANSI C95.3-1992 Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields - RF and Microwave[3] is used for guidance in measuring SAR due to the RF radiation exposure from the Equipment Under Test (EUT). These criteria for SAR evaluation are similar to those recommended by the National Council on Radiation Protection and Measurements (NCRP) in Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86 (c) NCRP, 1986, Bethesda, MD 20814.[4] SAR is a measure of the rate of energy absorption due to exposure to an RF transmitting source. SAR values have been related to threshold levels for potential biological hazards. 2.2 SAR Definition Specific Absorption Rate (SAR) is defined as the time derivative (rate) of the increme…
Text truncated - open the document above for the full version.
FCC ID: CKLHGP-3000E Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.29 mW/g, SAR (10g): 0.749 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 0025, 1851.25MHz Conducted Power -- 25.4dBm SAR Tot [mW/g] 1.30E-1 6.52E-1 1.17E+0 PCTEST ENGINEERING LAB INC. FCC ID: CKLHGP-3000E Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.11 mW/g, SAR (10g): 0.639 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 0025, 1851.25MHz Conducted Power -- 25.4dBm SAR Tot [mW/g] 1.10E-1 5.52E-1 9.94E-1 PCTEST ENGINEERING LAB INC. FCC ID: CKLHGP-3000E Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.19 mW/g, SAR (10g): 0.659 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 0600, 1880.00MHz Conducted Power -- 25.4dBm SAR Tot [mW/g] 1.28E-1 6.39E-1 1.15E+0 PCTEST ENGINEERING LAB INC. FCC ID: CKLHGP-3000E Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.48 mW/g, SAR (10g): 0.808 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 0600, 1880.00MHz Conducted Power -- 25.4dBm SAR Tot [mW/g] 1.40E-1 7.01E-1 1.26E+0 PCTEST ENGINEERING LAB INC. FCC ID: CKLHGP-3000E Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.17 mW/g, SAR (10g): 0.671 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 1175, 1908.75MHz Conducted Power -- 25.4dBm SAR Tot [mW/g] 1.12E-1 5.59E-1 1.01E+0 PCTEST ENGINEERING LAB INC. FCC ID: CKLHGP-3000E Head SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.23 mW/g, SAR (10g): 0.719 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 1175, 1908.75MHz Conducted Power -- 25.4dBm SAR Tot [mW/g] 1.37E-1 6.85E-1 1.23E+0 PCTEST ENGINEERING LAB INC.
FCC ID: CKLHGP-3000E BODY SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.881 mW/g, SAR (10g): 0.511 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 0600, 1880.00MHz Conducted Power -- 25.4dBm BODY SAR [1.5-cm spacing, no holder or belt clip] SAR Tot [mW/g] 8.60E-2 4.30E-1 7.74E-1 PCTEST ENGINEERING LAB INC. FCC ID: CKLHGP-3000E BODY SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.871 mW/g, SAR (10g): 0.499 mW/g HYUNDAI PCS Only Model: HGP-3000E Ch. 0600, 1880.00MHz Conducted Power -- 25.4dBm BODY SAR [1.5-cm spacing, no holder or belt clip] SAR Tot [mW/g] 8.38E-2 4.19E-1 7.54E-1 PCTEST ENGINEERING LAB INC.
Test Report S/N: SAR.991129630.CKLSAR Measurement Report Test Date(s): Nov. 29 - Dec. 03, 1999FCC Part 24 Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: SAR.991129630.CKLSAR Measurement Report Test Date(s): Nov. 29 - Dec. 03, 1999FCC Part 24 Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz)
Test Report S/N: SAR.991129630.CKLSAR Measurement Report Test Date(s): Nov. 29 - Dec. 03, 1999FCC Part 24 Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: SAR.991129630.CKLSAR Measurement Report Test Date(s): Nov. 29 - Dec. 03, 1999FCC Part 24 Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz)
EUT Dipole 1900 MHz Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 1900MHz Dipole Validation Antenna Position -- Out Crest Factor 1.0 SAR (1g): 10.8 mW/g ± 0.02 dB SAR Tot [mW/g] 1.15E+0 8.04E+0 PCTEST ENGINEERING LAB INC.
Validation Dipole D1900V2 SN:502, d = 10mmFrequency: 1900 MHz; Antenna Input Power: 250 [mW]Generic Twin Phantom; Flat Section; Grid Spacing: Dx = 15.0, Dy = 15.0, Dz = 10.0Probe: ET3DV5 - SN1302/DAE3; ConvF(4.55,4.55,4.55); Brain 1900 MHz: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 Cubes (2): Peak: 21.2 mW/g ± 0.01 dB, SAR (1g): 10.7 mW/g ± 0.01 dB, SAR (10g): 5.26 mW/g ± 0.01 dB, (Worst-case extrapol ation) Penetration depth: 7.0 (6.8, 7.5) [mm] SAR Tot [mW/g] 1.00E+02.00E+03.00E+04.00E+05.00E+06.00E+07.00E+08.00E+09.00E+0 Validation SN502, 12/16/98Schmid & Partner Engineering AG, Zürich Switzerland
Probe ET3DV5 SN:1368 Manufactured:December 1998 Calibrated:February 1999 Calibrated for System DASY3 Page 1 of 8 ET3DV5 SN:1368 Introduction The performance of all probes is measured before delivery. This includes an assessment of the characteristic parameters, receiving patterns as a function of frequency, frequency response and relative accuracy. Furthermore, each probe is tested in use according to a dosimetric assessment protocol. The sensitivity parameters (NormX, NormY, NormZ), the diode compresion parameter (DCP) and the conversion factor (ConvF) of the probe and some of the measurement diagrams are given in the following. The performance of the individual probes varies slightly due to tolerances arising from the manufacturing process. Since the lines are highly resistive (several MOhms), the offset and noise problem is greatly increased if signals in the low μV range are measured. Accurate measurement below 10 μW/g are possible if the following precautions are taken. 1) check the current grounding with the multimeter 1 , i.e., low noise levels, 2) compensate the current offset 1 , 3) use long integration time (approx. 10 seconds), 4) calibrate 1 before each measurement, 5) persons should avoid moving around the lab while measuring. Since the field distortion caused by the supporting material and the sheath is quite high in the θ direction, the receiving pattern is poor in air. However, the distortion in tissue equivalent material is much less because of its high dielectricity. In addition, the fields induced in the phantoms by dipole structures close to the body are dominently parallel to the surface. Thus, the error due to non-isotropy is much better than 1 dB for dosimetric assessments. The probes are calibrated in the TEM cell ifi 110 although the field distribution in the cell is not very uniform and the frequency response is not very flat. To ensure consistency, a strict protocol is followed. The conversion factor (ConF) between this calibration and the measurement in the tissue simulation solution is performed by comparison with temperature measurements and computer simulations. This conversion factor is only valid for the specified tissue simulating liquids at the specified frequencies. If measurements have to be performed in solutions with other electrical properties or at other frequencies, the conversion factor has to be assessed by the same procedure. As the probes have been constructed with printed resistive lines on ceramic substrates (thick film technique), the probe is very delicate with respect to mechanical shocks. Attention: Do not drop the probe or let the probe collide with any solid object. Never let the robot move without first activating the emergency stop feature (i.e., without first turning the data acquisition electronics on). 1 Feature of the DASY Software Tool. Fig 1: Due to the field distortion caused by the supporting material, the probe has two charac- teristic directions, referred to as angle ψ and θ. Page 2 of 8 ET3DV5 SN:1368 DASY3 - Parameters of Probe: ET3DV5 SN:1368 Sensitivity in Free Space NormX1.35μV/(V/m) 2 NormY1.29μV/(V/m) 2 NormZ1.46μV/(V/m) 2 Diode Compression DCP X78mV DCP Y78mV DCP Z78mV Sensitivity in Tissue Simulating Liquid 450 MHzConvF X6.2extrapolated ε r = 48 ± 5% ConvF Y6.2extrapolated σ =0.50 ± 10%mho/m ConvF Z6.2extrapolated(brain tissue simulating liquid) 900 MHz ConvF X5.8± 10% ε r = 42.5 ± 5% ConvF Y5.8± 10% σ =0.86 ± 10%mho/m ConvF Z5.8± 10%(brain tissue simulating liquid) 1500 MHz ConvF X5.2interpolated ε r = 41 ± 5% ConvF Y5.2interpolated σ =1.32 ± 10%mho/m ConvF Z5.2interpolated(brain tissue simulating liquid) 1800 MHz ConvF X4.9± 10% ε r = 41 ± 5% ConvF Y4.9± 10% σ =1.69 ± 10%mho/m ConvF Z4.9± 10%(brain tissue simulating liquid) Sensor Offset Probe Tip to Sensor Center2.7mm Surface to Probe Tip1.7 ± 0.2mm 1 Feature of the DASY Software Tool. Page 3 of 8 ET3DV5 SN:1368 Receiving Pattern (φ), θ = 0° f = 30 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 100 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 300 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 900 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot Page 4 of 8 ET3DV5 SN:1368 Isotropy Error (φ), θ = 0° -1.00 -0.80 -0.60 -0.40 -0.20 0.00 0.20 0.40 0.60 0.80 1.00 060120180240300360 error[dB] 30 MHz 100 MHz 300 MHz 900 MHz 1800 MHz 2500 MHz f = 1800 MHz, WG R22 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 2500 MHz, WG R26 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot Page 5 of 8 ET3DV5 SN:1368 Frequency Response of E-Field ( TEM-Cell:ifi110, Waveguide R22, R26 ) 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 050010001500200025003000 f [MHz] frequency response TEMR22R26 Page 6 of 8 ET3DV5 SN:1368 Dynamic Range f(SAR brain ) ( TEM-Cell:ifi110 ) 1.E+0 1.E+1 1.E+2 1.E+3 1.E+4 1.E+5 1.E+6 1.E+7 0.00010.0010.010.11.10.100. mW/cm 3 μ V not compensatedcompensated -3 -2 -1 0 1 0.00010.0010.010.1110100 mW/cm 3 errror[dB] not compensated diode characteristic compensated relative accuracy Page 7 of 8 ET3DV5 SN:1368 Conversion Factor Assessment Receiving Pattern (φ) ( in brain tissue, z = 5 mm ) -1.00 -0.80 -0.60 -0.40 -0.20 0.00 0.20 0.40 0.60 0.80 1.00 060120180240300360 error[dB] 900 MHz1800 MHz f = 900 MHz, WG R9 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0204060 z[mm] SAR[mW/cm 3 ] / W AnalyticalMeasuremets f = 1800 MHz, WG R22 …
Text truncated - open the document above for the full version.
i FCC RF EXPOSURE INFORMATION In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency (RF) electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this phone complies with the FCC guidelines and these international standards. Use only the supplied or an approved antenna. Unauthorized antennas, modifications, or attachments could impair call quality, damage the phone, or result in violation of FCC regulations. Do not use the phone with a damaged antenna. If a damaged antenna comes into contact with the skin, a minor burn may result. Please contact your local dealer for replacement antenna. Body-worn Operation This device was tested for typical body-worn operations with the back of the phone kept 0.6 inches (1.5 cm) from the body. To comply with FCC RF exposure requirements, a minimum separation distance of 0.6 inches (1.5 cm) must be maintained between the user’s body and the back of the phone, including the antenna, whether extended or retracted. Third-party belt-clips, holsters and similar accessories containing metallic components should not be used. Body-worn accessories that cannot maintain 0.6 inch (1.5 cm) separation distance between the user’s body and the back of the phone, and have not been tested for typical body-worn operations may not comply with FCC RF exposure limits and should be avoided. For more information about RF exposure, please visit the FCC website at www.fcc.gov WARNING! Read this information before using your phone
© 1999 PCTEST Engineering Lab., Inc. PCTEST Engineering Laboratory, Inc. 6660-B 6660-B DobbinDobbin Road Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290-6652 TEL (410) 290-6652 •• FAX (410) 290-6654 FAX (410) 290-6654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE FCC Part 24 Certification HYUNDAI Electronics Industries Co., Ltd.Dates of Tests: Nov. 29 - Dec. 03, 1999 San 136-1, Ami-Ri, Bubal-Eub Test Report S/N: 24.991129629.CKL Ichon-Si, Kyungki-Do, KOREA 467-701Test Site: PCTEST Lab, Columbia MD U.S.A. Attn: Mr. Ja Beom Koo Quality Management Dept. System Quality Assurance Office FCC ID CKLHGP-3000E APPLICANT HYUNDAI Electronics Industries Co., Ltd. Classification:Licensed Portable Transmitter Held to Ear (PCE) FCC Rule Part(s):§24(E), §2 EUT Type:Single-Band PCS CDMA Phone Trade Name/Model(s):HYUNDAI HGP-3000E Frequency Range:Tx: 1851.25 – 1908.75MHz Rx: 1931.25 – 1988.75MHz Max. RF Output Power:0.35 Watts EIRP (25.44 dBm) Frequency Tolerance:0.00025% (2.5 ppm) Emission Designator:1M25F9W This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in §2.947 with the following remarks (Note Codes): * (BC) The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a) 991129629.CKL Certification © 1999PCTEST Engineering Laboratory, Inc.FCC Part 24 TABLE OF CONTENTS ATTACHMENT A: COVER LETTER(S) ATTACHMENT B: ATTESTATION STATEMENT(S) ATTACHMENT C: TEST REPORT 1.1 SCOPE 1 2.1 INTRODUCTION (SITE DESCRIPTION) 2 3.1 INSERTS PER §2.1033 3 4.1 DESCRIPTION OF TESTS 4-5 5.1 TEST DATA (Equivalent Isotropically Radiated Power) 6 6.1 TEST DATA (RADIATED) 7-9 7.1 TEST DATA (FREQUENCY STABILITY) 10-11 8.1 PLOTS OF EMISSIONS 12 9.1 LIST OF TEST EQUIPMENT 13 10.1 SAMPLE CALCULATIONS 14 11.1 RECOMMENDATION / CONCLUSION 15 ATTACHMENT D: TEST PLOTS ATTACHMENT E: FCC ID LABEL / LOCATION ATTACHMENT F: TEST SETUP PHOTOGRAPHS ATTACHMENT G: EXTERNAL PHOTOGRAPHS ATTACHMENT H: INTERNAL PHOTOGRAPHS ATTACHMENT I: BLOCK DIAGRAM(S) ATTACHMENT J: SCHEMATIC DIAGRAM(S) ATTACHMENT K: PARTS LIST/TUNE UP PROCEDURE ATTACHMENT L:OPERATIONAL DESCRIPTION ATTACHMENT M:USER’S MANUAL ATTACHMENT N:SAR MEASUREMENT REPORT ATTACHMENT O: SAR TEST DATA ATTACHMENT P:SAR TEST SETUP PHOTOGRAPHS ATTACHMENT Q:DIPOLE VALIDATION ATTACHMENT R:PROBE CALIBRATION Test Report S/N: 24.991129629.CKL FCC Part 24 Dates of Tests: Nov. 29 - Dec. 03, 1999 Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone 1 FCC ID: CKLHGP-3000E (Tx 1851.25 – 1908.75 MHz) MEASUREMENT REPORT 1.1 Scope Product Evaluation and determination of electromagnetic emissions (EME) of radio frequency devices including intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal Communications Commission. §2.1033 General Information Applicant Name: HYUNDAI Electronics Industries Co., Ltd. Address: San 136-1, Ami-Ri, Bubal-Eub Ichon-Si, Kyungki-Do, KOREA 467-701 Attention: Mr. Ja Beom Koo Quality Management Dept. System Quality Assurance Office • FCC ID: CKLHGP-3000E • Trade Name(s): HYUNDAI • Model(s): HGP-3000E • Quantity: Quantity production is planned • Emission Designator: 1M25F9W • Max. RF Output Power: 0.35 W (EIRP) • AC Power Adapter: HYUNDAI Model: HTC-12N • FCC Classification: Licensed Portable Tx Held to Ear (PCE) • Equipment (EUT) Type: Single-Band PCS CDMA Phone • FCC Rule Part(s): § 24(E), §2 • Application Type: Certification • Modulation: CDMA • Tx Frequency Range: 1851.25 – 1908.75 MHz • Rx Frequency Range: 1931.25 – 1988.75 MHz • Frequency Tolerance: ± 2.5 ppm • Dates of Tests: Nov. 29 - Dec. 03, 1999 • Place of Tests: PCTEST Lab, Columbia, MD U.S.A. 991129629.CKL Test Report S/N: 24.991129629.CKLFCC Part 24 Dates of Tests: Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST LabHYUNDAI Single-Band PCS CDMA Phone2 FCC ID: CKLHGP-3000E (Tx 1851.25 – 1908.75 MHz) 2.1 INTRODUCTION These measurement tests were conducted at PCTEST Engineering Laboratory, Inc. facility in New Concept Business Park, Guilford Industrial Park, Columbia, Maryland. The site address is 6660-B Dobbin Road, Columbia, MD 21045. The test site is one of the highest points in the Columbia area with an elevation of 390 feet above mean sea level. The site coordinates are 39° 11'15" N latitude and 76° 49'38" W longitude. The facility is 1.5 miles North of the FCC laboratory, and the ambient signal and ambient signal strength are approximately equal to those of the FCC laboratory. There are no FM or TV transmitters within 15 miles of the site. The detailed description of the measurement facility was found to be in compliance with the requirements of § 2.948 according to ANSI C63.4 on October 19, 1992. PCTEST Lab is recognized under the National Voluntary Laboratory Accreditation Program for satisfactory compliance with criteria established in Title 15, Part 285 Code of Federal Regulations. These criteria encompass the requirements of ISO/IEC Guide 25 and the relevant requirements of ISO 9002 (ANSI/ASQC Q92-1987) as suppliers of calibration or test results. The Scope of PCTEST Accreditation are for Electromagnetic Compatibility and Telecommunications and FCC. 2.2 PCTEST Location The map at right shows the location of the PCTEST Lab, its proximity to the FCC Lab, the Columbia vicinity area, the Baltimore- Washington International …
Text truncated - open the document above for the full version.
Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz) Test Report S/N: 24.991129629.CKLFCC Part 24 Test Date(s): Nov. 29 - Dec. 03, 1999Certification © 1999 PCTEST Lab HYUNDAI Single-Band PCS CDMA Phone NVLAP Lab Code: 100431-0 FCC ID: CKLHGP-3000E (Tx 1851.25 - 1908.75 MHz)
6660-B Dobbin Road · Columbia, Maryland · United States
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 24E | 1.85 GHz - 1.91 GHz | 350.00 mW | 1M25F9W | 2.5000000000 ppm |

Single-Mode Cellular CDMA WLL Terminal
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Tri-Mode Dual Band Analog/PCS Phone (AMPS/CDMA)
Equipment Class
PCE - PCS Licensed Transmitter held to ear15-inch Color Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral21-inch Color Monitor
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
17" CRT MONITOR
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral