FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hyundai Electronics Industries Co Ltd/
  3. CKLHGT-1000E

CKLHGT-1000ETri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA)

Hyundai Electronics Industries Co Ltd
Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA) - FCC ID CKLHGT-1000E - Hyundai Electronics Industries Co Ltd
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Mar 29, 2000
Application Purpose
Original Equipment
Date of Application
Feb 24, 2000
Equipment Note
Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA)
Frequency Range
1931.25000000 - 1988.75000000
Company
Hyundai Electronics Industries Co Ltd
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Page 1-1 FCC RF EXPOSURE INFORMATION In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this phone complies with the FCC guidelines and these international standards. Use only the supplied or an approved antenna. Unauthorized antennas, modifications, or attachments could impair call quality, damage the phone, or result in violation of FCC regulations. Do not use the phone with a damaged antenna. If a damaged antenna comes into contact with the skin, a minor burn may result. Please contact your local dealer for replacement antenna. Body-worn Operation This device was tested for typical body-worn operations with the back of the phone kept 0.79 inches (2cm) from the body. To comply with FCC RF exposure requirements, a minimum separation distance of 0.79 inches (2cm) must be maintained between the user’s body and the back of the phone, including the antenna, whether extended or retracted. Third-party belt-clips, holsters and similar accessories containing metallic components should not be used. Body-worn accessories that cannot maintain 0.79 inch (2cm) separation distance between the user’s body and the back of the phone, and have not been tested for typical body-worn operations may not comply with FCC RF exposure limits and should be avoided. For more information about RF exposure, please visit the FCC website at www.fcc.gov WARNING! Read this information before using your phone

Attestation Statements

l HYUNDAI HYUNDAI ELECTRONICS IND. CO., LTD Quality Assurance Off ice Quality Assistance De t. San 136-1, Ami-Ri, Buba -Eub, P Ichon-Si Kyoungki-Do, 467-fO1, Korea AFFIDAVIT FOR ESN PROTECTION OF CELLULAR MOBILE TELEPHONES We hereby certify that the Handheld Portable Cellular Phone (FCC ID: CKLHGT-1000E) is so designed that it complies with all the requirements for ESN protection specified in Section 22.919 of the FCC Rules. a) The transmitter in service has a unique ESN. b) The ESN host component is permanently attached to a main circuit board of the mobile transmitter and the integrity of the unit operating software cannot be altered. The ESN is plated from fraudulent contact and tampering. The ESN is encoded using multiplication by a polynomial and the ESN data programmed in the memory with other information. C) The ESN is factory-set and cannot be altered, transfered, removed or otherwise able to be manipulated. Cellular mobile equipment is specifically designed such that any attempt to remove, tamper with, or change the ESN chip, its logic system, or firmware originally programmed by the manufacturer will render the mobile transmitter inoperative. Sincerely, I Ki Soo Kim EMC Test Lab. / Section Chief Quality Assistance Dept. Quality Assurance Office Hyundai Electronics Industries Co., Ltd.

Cover Letter(s)

February 25, 2000 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT:HYUNDAI Electronics Industries Co., Ltd. FCC ID: CKLHGT-1000E Part 24/22 Certification Gentlemen: Attached herewith, on behalf of HYUNDAI Electronics Industries Co., Ltd. is an application for Part 24/22 Certification of the following Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA): FCC ID:CKLHGT-1000E TRADE / MODEL(s):HYUNDAI HGT-1000E EUT TYPE:Licensed Portable Transmitter Held to Ear (PCE) Tx Freq. Range:824.04-849.97 MHz (AMPS), 824.70-848.31 MHz (CDMA), 1851.25-1908.75 MHz (PCS CDMA) Rx Freq. Range:869.04-893.97 MHz (AMPS), 869.70-893.31 MHz (CDMA), 1931.25-1988.75MHz (PCS CDMA) Max. RF Output Power:0.6 W ERP AMPS (27.8 dBm) / 0.37 W ERP CDMA (25.67 dBm) 0.33W EIRP PCS CDMA (25.12 dBm) Attached is the Letter of Authorization, Confidentiality Request, ESN Affidavit, measurement report data and plots, RF Exposure measurement report, FCC ID label and location, test setup photographs, internal and external photographs, block diagrams (confidential), schematic diagrams (confidential), operational description (confidential), parts list & tune-up procedure (confidential), and the user's manual. Should you have any questions or comments concerning the above, please contact the undersigned. cc:Mr. Ki-Soo Kim Section Chief, QA Office HYUNDAI Electronics Industries Co., Ltd.

External Photos

Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone

ID Label/Location Info

© 2000 PCTEST Lab FCC ID SAMPLE LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. (SEE NEXT PAGE) IDENTIFICATION LABEL with regard to the FCC Rule Part 2.983 According to the requirement section 2.925 and 2.926, the sample label shown below shall be permanently affixed at a conspicuous location on the device supplied to the user and be readily visible to the purchaser at the time of purchase. Cellular/PCS Phone MODEL : HGT-1OOOE FCC ID : CKLHGT-1000E Serial No. : MADE IN KOREA HYUNDAI ELECTRONICS IND. CO., LTD.

Internal Photos

Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone Test Report S/N: 24/22.991228690.CKLFCC Parts 24 & 22 Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab FCC ID: CKLHGT-1000E (Model: HGT-1000E) NVLAP Lab Code: 100431-0 HYUNDAI Tri-Mode Dual-Band Analog/PCS Phone

RF Exposure Info

© 2000 PCTEST Engineering Lab., Inc. PCTEST Engineering Laboratory, Inc. 6660-B Dobbin Road 6660-B Dobbin Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290-6652 TEL (410) 290-6652 •• FAX (410) 290-6654 FAX (410) 290-6654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE (SAR EVALUATION) HYUNDAI Electronics Industries Co., Ltd.Dates of Tests: February 07-11, 2000 San 136-1, Ami-Ri, Bubal-EubTest Report S/N: SAR.991228690.CKL Ichon-Si, Kyungki-Do, KOREA 467-701Test Site: PCTEST Lab, Columbia, MD USA Attn: Mr. Ja Beom Koo, QM Dept. System Quality Assurance Office FCC ID CKLHGT-1000E APPLICANT HYUNDAI Electronics Industries Co., Ltd. EUT Type:Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA) Tx Frequency:824.04 – 848.97 MHz (AMPS) / 824.70 – 848.31 MHz (CDMA) 1851.25 – 1908.75 MHz (PCS CDMA) Rx Frequency:869.04 – 893.97 MHz (AMPS) / 869.70 – 893.31 MHz (CDMA) 1931.25 – 1908.75 MHz (PCS CDMA) Max. RF Output Power:0.6 W ERP AMPS (27.8 dBm) / 0.37 W ERP CDMA (25.67 dBm) 0.33 W EIRP (25.12 dBm) Trade Name/Model(s):HYUNDAI HGT-1000E FCC Classification:Licensed Portable Transmitter Held to Ear (PCE) Application Type:Certification FCC Rule Part(s):§2.1093; ET Docket 96.326 This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1992. (See Test Report). I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. NVLAP accreditation does not constitute any product endorsement by NVLAP or any agency of the United States Government. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). 991228690.CKL SAR Measurement ReportFCC Part 24/22 Certification © 2000 PCTEST Labi Table of Contents 1.1 SCOPE 1 2.1 INTRODUCTION / SAR DEFINITION 2 3.1 SAR MEASUREMENT SET-UP 3 4.1 E-FIELD PROBE SYSTEM 4 5.1 E-FIELD PROBE CALIBRATION PROCESS 5-6 6.1 PHANTOM, HOLDER, & EQUIVALENT TISSUE 7 7.1 SYSTEM SPECIFICATIONS 8 8.1 MEASUREMENT PROCESS 9 9.1 TEST POSITION OF THE PHONE 10 10.1 BODY SAR TEST SETUP11 11.1 ANSI/IEEE C95.1 RF EXPOSURE LIMITS 12 12.1 MEASUREMENT UNCERTAINTIES 13 13.1 TEST DATA SUMMARY 14-17 14.1 SAR TEST EQUIPMENT LIST 18 15.1 CONCLUSION 19 16.1 REFERENCES 20 Test Report S/N: SAR.991228690.CKLSAR Measurement Report Test Date(s): February 07-11, 2000FCC Part 24/22 Certification HYUNDAI FCC ID: CKLHGT-1000E (Model: HGT-1000E) © 2000 PCTEST LabTri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA)1 SAR MEASUREMENT REPORT 1.1 Scope Environmental evaluation measurements of specific absorption rate 1 (SAR) distributions in simulated human head and body tissues exposed to radiofrequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 2 Company Name:HYUNDAI Electronics Industries Co., Ltd. Address:San 136-1, Ami-Ri, Bubal-Eub Ichon-Si, Kyungki-Do, KOREA 467-701 Attention:Mr. Ja Beom Koo, QM Dept. System Quality Assurance Office • EUT Type:Tri-Mode Dual-Band Analog/PCS Phone • Trade Name / Model:HYUNDAI HGT-1000E • FCC IDENTIFIER:CKLHGT-1000E • Tx Frequency:824.04 – 848.97 MHz (AMPS) 824.70 – 848.31 MHz (CDMA) 1851.25 – 1908.75 MHz (PCS CDMA) • Rx Frequency:869.04 – 893.97 MHz (AMPS) 869.70 – 893.31 MHz (CDMA) 1931.25 – 1988.75 MHz (PCS CDMA) • Application Type: Certification • FCC Classification:Licensed Portable Transmitter Held to Ear (PCE) • Modulation(s):AMPS / CDMA • FCC Rule Part(s):§2.1093, Docket 96-326 • Max. RF Output Power:0.6W ERP AMPS (27.8 dBm) / 0.37W ERP CDMA (25.67 dBm) 0.33W EIRP CDMA (25.12 dBm) • Antenna Type:Helical (λ/3) • Antenna Dimensions:11.9 cm. (Length) • Dates of Tests:February 07-11, 2000 • Place of Tests:PCTEST Engineering Lab. Columbia, MD, U.S.A. • Report Serial No.:SAR.991228690.CKL 1 Specific Absorption Rate (SAR) is a measure of the rate of energy absorption due to exposure to an RF transmitting source (wireless portable device). 2 IEEE/ANSI Std. C95.1-1992 limits are used to determine compliance with FCC ET Docket 93-62. Fig. 1 SAR Test Setup Test Report S/N: SAR.991228690.CKLSAR Measurement Report Test Date(s): February 07-11, 2000FCC Part 24/22 Certification HYUNDAI FCC ID: CKLHGT-1000E (Model: HGT-1000E) © 2000 PCTEST LabTri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA)2 2.1 INTRODUCTION The FCC has adopted the guidelines for evaluating the environmental effects of radiofrequency radiation in ET Docket 93-62 on Aug. 6, 1996 to protect the public and workers from the potential hazards of RF emissions due to FCC-regulated portable devices.[1] The safety limits used for the environmental evaluation measurements are based on the criteria published by the American National Standards Institute (ANSI) for localized specific absorption rate (SAR) in IEEE/ANSI C95.1-1992 Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. (c) 1992 by the Institute of Electrical and Electronics Engineers, Inc., New York, New York 10017.[2] The measurement procedure described in IEEE/ANSI C95.3-1992 Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields - RF and Microwave[3] is used for guidance in measuring SAR due to the RF radiation exposure from the Equipment Under Test (EUT). These criteria for SAR evaluation are similar to those recommended by the National Council on Radiation Protection and Measurements (NCRP) in Biological Effects and Exposure Cr…

Text truncated - open the document above for the full version.

RF Exposure Info

HYUNDAI FCC ID:CKLHGT-1000E -- FM Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.794 mW/g, SAR (10g): 0.546 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.991 [824.04MHz] Conducted Power = 27.0dBm Test Date - 02-07-00 SAR Tot [mW/g] 6.89E-2 2.07E-1 3.45E-1 4.82E-1 6.20E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.517 mW/g, SAR (10g): 0.366 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.991 [824.04MHz] Conducted Power = 27.0dBm Test Date - 02-07-00 SAR Tot [mW/g] 4.75E-2 1.43E-1 2.37E-1 3.33E-1 4.28E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.699 mW/g, SAR (10g): 0.489 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.383 [836.49MHz] Conducted Power = 27.0dBm Test Date - 02-07-00 SAR Tot [mW/g] 6.54E-2 1.96E-1 3.27E-1 4.58E-1 5.89E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.348 mW/g, SAR (10g): 0.243 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.383 [836.49MHz] Conducted Power = 27.0dBm Test Date - 02-07-00 SAR Tot [mW/g] 3.23E-2 9.69E-2 1.62E-1 2.26E-1 2.91E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.758 mW/g, SAR (10g): 0.527 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.799 [848.97MHz] Conducted Power = 27.0dBm Test Date - 02-07-00 SAR Tot [mW/g] 6.88E-2 2.06E-1 3.44E-1 4.82E-1 6.19E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.487 mW/g, SAR (10g): 0.338 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.799 [848.97MHz] Conducted Power = 27.0dBm Test Date - 02-07-00 SAR Tot [mW/g] 4.39E-2 1.32E-1 2.19E-1 3.07E-1 3.95E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- CDMA Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.18 mW/g, SAR (10g): 0.824 mW/g HYUNDAI Tri-mode Model:HGT-1000E CDMA Mode, Ch.1013 [824.70MHz] Conducted Power = 24.8dBm Test Date - 02-07-00 SAR Tot [mW/g] 1.12E-1 3.35E-1 5.59E-1 7.83E-1 1.01E+0 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- CDMA Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 MHz Brain: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.19 mW/g, SAR (10g): 0.841 mW/g HYUNDAI Tri-mode Model:HGT-1000E CDMA Mode, Ch.1013 [824.70MHz] Conducted Power = 24.8dBm Test Date - 02-07-00 SAR Tot [mW/g] 1.10E-1 3.31E-1 5.51E-1 7.72E-1 9.93E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.30 mW/g, SAR (10g): 0.722 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0025 [1851.25MHz] Conducted Power = 23.8dBm Test Date - 02-08-00 SAR Tot [mW/g] 1.36E-1 4.07E-1 6.78E-1 9.49E-1 1.22E+0 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.03 mW/g, SAR (10g): 0.580 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0025 [1851.25MHz] Conducted Power = 23.8dBm Test Date - 02-08-00 SAR Tot [mW/g] 1.08E-1 3.24E-1 5.40E-1 7.57E-1 9.73E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.30 mW/g, SAR (10g): 0.761 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0600 [1880.00MHz] Conducted Power = 23.8dBm Test Date - 02-08-00 SAR Tot [mW/g] 1.36E-1 4.08E-1 6.79E-1 9.51E-1 1.22E+0 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Brain SAR Generic Twin Phantom; Left Hand Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Brain: σ = 1.82 mho/m ε r = 40.4 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.07 mW/g, SAR (10g): 0.626 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0600 [1880.00MHz] Conducted Power = 23.8dBm Test Date - 02-08-00 SAR Tot [mW/g] 1.08E-1 3.25E-1 5.42E-1 7.59E-1 9.76E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Brain SAR Generic Twin Phantom;…

Text truncated - open the document above for the full version.

RF Exposure Info

Test Report S/N: SAR.991228691.CKLSAR Measurement Report Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHGT-1000E NVLAP Lab Code: 100431-0 Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA) Test Report S/N: SAR.991228691.CKLSAR Measurement Report Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHGT-1000E NVLAP Lab Code: 100431-0 Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA) Test Report S/N: SAR.991228691.CKLSAR Measurement Report Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHGT-1000E NVLAP Lab Code: 100431-0 Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA)

RF Exposure Info

HYUNDAI FCC ID:CKLHGT-1000E -- FM Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 Muscle: σ = 0.95 mho/m ε r = 56.2 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.962 mW/g, SAR (10g): 0.671 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.0991 [824.04MHz] Conducted Power = 27.0dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-08-00 SAR Tot [mW/g] 9.21E-2 2.76E-1 4.61E-1 6.45E-1 8.29E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 Muscle: σ = 0.95 mho/m ε r = 56.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.920 mW/g, SAR (10g): 0.640 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.0991 [824.04MHz] Conducted Power = 27.0dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-08-00 SAR Tot [mW/g] 8.69E-2 2.61E-1 4.35E-1 6.08E-1 7.82E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 Muscle: σ = 0.95 mho/m ε r = 56.2 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.905 mW/g, SAR (10g): 0.627 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.0383 [836.49MHz] Conducted Power = 27.0dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-08-00 SAR Tot [mW/g] 8.47E-2 2.54E-1 4.23E-1 5.93E-1 7.62E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 Muscle: σ = 0.95 mho/m ε r = 56.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.976 mW/g, SAR (10g): 0.677 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.0383 [836.49MHz] Conducted Power = 27.0dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-08-00 SAR Tot [mW/g] 9.08E-2 2.72E-1 4.54E-1 6.36E-1 8.17E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 Muscle: σ = 0.95 mho/m ε r = 56.2 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.754 mW/g, SAR (10g): 0.519 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.0799 [848.97MHz] Conducted Power = 27.0dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-08-00 SAR Tot [mW/g] 7.29E-2 2.19E-1 3.64E-1 5.10E-1 6.56E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- FM Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 Muscle: σ = 0.95 mho/m ε r = 56.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 0.827 mW/g, SAR (10g): 0.573 mW/g HYUNDAI Tri-mode Model:HGT-1000E FM Mode, Ch.0799 [848.97MHz] Conducted Power = 27.0dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-08-00 SAR Tot [mW/g] 8.18E-2 2.45E-1 4.09E-1 5.73E-1 7.36E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.03 mW/g, SAR (10g): 0.614 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0025 [1851.25MHz] Conducted Power = 23.8dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-09-00 SAR Tot [mW/g] 1.06E-1 3.19E-1 5.31E-1 7.44E-1 9.57E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.01 mW/g, SAR (10g): 0.539 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0025 [1851.25MHz] Conducted Power = 23.8dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-09-00 SAR Tot [mW/g] 8.73E-2 2.62E-1 4.37E-1 6.11E-1 7.86E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 0.941 mW/g, SAR (10g): 0.551 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0600 [1880.00MHz] Conducted Power = 23.8dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-09-00 SAR Tot [mW/g] 9.71E-2 2.91E-1 4.85E-1 6.80E-1 8.74E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.08 mW/g, SAR (10g): 0.533 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.0600 [1880.00MHz] Conducted Power = 23.8dBm [spacing = 2.0cm from flat phantom to phone; no holster or belt clip] Test Date -- 02-09-00 SAR Tot [mW/g] 8.96E-2 2.69E-1 4.48E-1 6.27E-1 8.06E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHGT-1000E -- PCS Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- In; Crest Factor 1.0 SAR (1g): 1.06 mW/g, SAR (10g): 0.608 mW/g HYUNDAI Tri-mode Model:HGT-1000E PCS Mode, Ch.1175 [1908.75MHz] Conducted Power = 23.8dBm [spacing = 2.0cm from flat phantom to…

Text truncated - open the document above for the full version.

RF Exposure Info

Test Report S/N: SAR.991228691.CKLSAR Measurement Report Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHGT-1000E NVLAP Lab Code: 100431-0 Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA) Test Report S/N: SAR.991228691.CKLSAR Measurement Report Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHGT-1000E NVLAP Lab Code: 100431-0 Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA) Test Report S/N: SAR.991228691.CKLSAR Measurement Report Test Date(s): February 07-11, 2000Certification © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHGT-1000E NVLAP Lab Code: 100431-0 Tri-Mode Dual-Band Analog/PCS Phone (AMPS/CDMA)

RF Exposure Info

Validation Dipole D835V2 SN:406, d = 15mm Frequency: 835 MHz; Antenna Input Power: 250 [mW] Generic Twin Phantom; Flat Section; Grid Spacing: Dx = 20.0, Dy = 20.0, Dz = 10.0 Probe: ET3DV5 - SN1342/DAE3; ConvF(5.75,5.75,5.75); Brain 835 MHz: σ = 0.79 mho/m ε r = 41.9 ρ = 1.00 g/cm 3 Cubes (2): Peak: 3.17 mW/g ± 0.03 dB, SAR (1g): 2.11 mW/g ± 0.03 dB, SAR (10g): 1.41 mW/g ± 0.04 dB, (Worst-case extrapolation) Penetration depth: 13.4 (12.3, 14.9) [mm] Powerdrift: -0.01 dB SAR Tot [mW/g] 2.50E-1 5.00E-1 7.50E-1 1.00E+0 1.25E+0 1.50E+0 1.75E+0 2.00E+0 2.25E+0 2.50E+0 Validation SN406 Schmid & Partner Engineering AG, Zürich Switzerland 835MHz Brain Dipole Validation Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835MHz: σ = 0.86 mho/m ε r = 42.5 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 2.14 mW/g, SAR (10g): 1.29 mW/g 835MHz Brain Dipole Validation (D835V2 S/N: 406) Frequency: 835 MHz; Antenna Input Power: 250 [mW] PCTEST Brain Tissue Simulating Liquid SAR Tot [mW/g] 2.57E-1 5.79E-1 1.12E+0 1.51E+0 1.71E+0 PCTEST Engineering Laboratory, Inc. 835MHz Muscle Dipole Validation Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1368 -- Probe Cal Date 2/99 Medium Parameters 835 Muscle: σ = 0.95 mho/m ε r = 56.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 2.19 mW/g, SAR (10g): 1.33 mW/g 835MHz Muscle Dipole Validation (D835V2 S/N: 406) Frequency: 835 MHz; Antenna Input Power: 250 [mW] PCTEST Muscle Tissue Simulating Liquid SAR Tot [mW/g] 1.74E-1 5.23E-1 8.72E-1 1.22E+0 1.57E+0 PCTEST Engineering Laboratory, Inc. Validation Dipole D1900V2 SN:502, d = 10mm Frequency: 1900 MHz; Antenna Input Power: 250 [mW] Generic Twin Phantom; Flat Section; Grid Spacing: Dx = 15.0, Dy = 15.0, Dz = 10.0 Probe: ET3DV5 - SN1302/DAE3; ConvF(4…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bong Jae Hur(Manager, QA Office)
[email protected]82 336-30-3280Fax: 82 336-3003265

Technical Contact

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652

6660-B Dobbin Road · Columbia, Maryland · United States

Non-Technical Contact

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652

Test Firm

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652Fax: 410-290-6654

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
424E1.93 GHz - 1.99 GHz330.00 mW1M25F9W2.5 ppm
Confidentiality
Long Term

Other Applications from Hyundai Electronics Industries Co Ltd

Single-Mode Cellular CDMA WLL Terminal - FCC ID CKLHWP-120 - Hyundai Electronics Industries Co Ltd
CKLHWP-120

Single-Mode Cellular CDMA WLL Terminal

Feb 15, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Tri-Mode Dual Band Analog/PCS Phone (AMPS/CDMA) - FCC ID CKLTX-20B - Hyundai Electronics Industries Co Ltd
CKLTX-20B

Tri-Mode Dual Band Analog/PCS Phone (AMPS/CDMA)

Jan 28, 2001

Equipment Class

PCE - PCS Licensed Transmitter held to ear
CKLA526

15-inch Color Monitor

Dec 28, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CKLC21R05110

21-inch Color Monitor

Dec 28, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
17" CRT MONITOR - FCC ID CKLC17F06090 - Hyundai Electronics Industries Co Ltd
CKLC17F06090

17" CRT MONITOR

Dec 21, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral