FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hyundai Electronics Industries Co Ltd/
  3. CKLHWP-220

CKLHWP-220PCS CDMA WLL Phone

Hyundai Electronics Industries Co Ltd
PCS CDMA WLL Phone - FCC ID CKLHWP-220 - Hyundai Electronics Industries Co Ltd
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Aug 31, 2000
Application Purpose
Original Equipment
Date of Application
Jul 09, 2000
Equipment Note
PCS CDMA WLL Phone
Frequency Range
1851.25000000 - 1908.75000000
Company
Hyundai Electronics Industries Co Ltd
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

June 28, 2000 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: HYUNDAI Electronics Industries, Co., Ltd. FCC ID: CKLHWP-220 Part 24 Certification Gentlemen: Attached herewith, on behalf of HYUNDAI Electronics Industries, Co., Ltd. is an application for Part 24 Certification of the following: FCC ID: CKLHWP-220 TRADE / MODEL(s): HYUNDAI HWP-220 Equipment Class: Licensed Base Station for Part 24 Equipment Type: Single-Mode PCS CDMA WLL Phone Tx Freq. Range: 1851.25 – 1908.75 MHz Rx Freq. Range: 1931.25 – 1988.75 MHz Max. RF Output Power: 0.322 W EIRP (25.072 dBm) Attached is the Letter of Authorization, Confidentiality Request, measurement report data and plots, RF Exposure measurement report & photographs, FCC ID label and location, test setup photographs, internal and external photographs, block diagrams (confidential), schematic diagrams (confidential), operational description (confidential), parts list & tune-up procedure (confidential), and the user's manual. Should you have any questions or comments concerning the above, please contact the undersigned. cc: Mr. Ki Soo Kim Assitant Manager, Quality Assurance Office

External Photos

© 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone

ID Label/Location Info

© 2000 PCTEST Lab FCC ID SAMPLE LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. (SEE NEXT PAGE)

Internal Photos

© 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: HWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone

RF Exposure Info

© 2000 PCTEST Engineering Lab., Inc. PCTEST Engineering Laboratory, Inc. 66606660--B Dobbin Road B Dobbin Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290TEL (410) 290--6652 6652 •• FAX (410) 290 FAX (410) 290--66546654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE (SAR EVALUATION) HYUNDAI Electronics Industries Co., Ltd. Dates of Tests: June 27-30, 2000 San 136-1, Ami-Ri, Bubal-Eub Test Report S/N: SAR.200626310.CKL Ichon-Si, Kyungki-Do, Korea 467-701 Test Site: PCTEST Lab, Columbia, MD USA Attn: Mr. Ki Soo Kim, Asst. Manager Quality Assurance Office FCC ID CKLHWP-220 APPLICANT HYUNDAI Electronics Industries Co., Ltd. EUT Type: PCS CDMA WLL Phone Tx Frequency: 1851.25 – 1908.75 MHz Rx Frequency: 1931.25 – 1988.75 MHz Max. RF Output Power: 0.322 W EIRP (25.072 dBm) Trade Name/Model(s): HYUNDAI HWP-220 FCC Classification: Licensed Base Station for Part 24 (PCB) Application Type: Certification Serial Number: n/a (pre production) FCC Rule Part(s): 2.1093; ET Docket 96.326 This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and had been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1992. (See Test Report). I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. NVLAP accreditation does not constitute any product endorsement by NVLAP or any agency of the United States Government. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a) 200626310.CKL FCC Part 24 Certification PCTEST Engineering Laboratory, Inc. i Table of Contents SCOPE 1 INTRODUCTION / SAR DEFINITION 2 SAR MEASUREMENT SET-UP 3 E-FIELD PROBE SYSTEM 4 E-FIELD PROBE CALIBRATION PROCESS 5 DATA EXTRAPOLATION 6 PHANTOM & EQUIVALENT TISSUE 7 SYSTEM SPECIFICATIONS 8 MEASUREMENT PROCESS 9 TEST POSITION OF THE EUT 10 ANSI/IEEE C95.1 RF EXPOSURE LIMITS 11 MEASUREMENT UNCERTAINTIES 12 TEST DATA SUMMARY 13 SAR TEST EQUIPMENT LIST 14 CONCLUSION 15 REFERENCES 16 Test Report S/N: SAR.200626310.CKL SAR Measurement Report Test Date(s): June 26-30, 2000 FCC Part 24 Certification FCC ID: CKLHWP-220 (Tx 1851.25 – 1908.75 MHz) © 2000 PCTEST Lab HYUNDAI PCS CDMA WLL Phone 1 SAR MEASUREMENT REPORT 1.1 Scope Environmental evaluation measurements of specific absorption rate 1 (SAR) distributions in simulated human tissues exposed to radiofrequency (RF) radiation from wireless portable devices for compliance with the rules and regulations of the U.S. Federal Communications Commission (FCC). 2 Company Name: HYUNDAI Electronics Industries Co., Ltd. Address: San 136-1, Ami-Ri, Bubal-Eub Ichon-Si, Kyungki-Do, KOREA 467-701 Attention: Mr. Ki Soo Kim, Assistant Manager - Quality Assurance Office • EUT Type: PCS CDMA WLL Phone • Trade Name: HYUNDAI • Model(s): HWP-220 • FCC IDENTIFIER: CKLHWP-220 • S/N: Pre-production • Tx Frequency: 1851-25 – 1908.75 MHz • Rx Frequency: 1931.25 – 1988.75 MHz • Application Type: Certification • FCC Classification: Licensed Base Station for Part 24 (PCB) • FCC Rule Part(s): § 2.1093, Docket 96-326 • Modulation(s): CDMA • Max RF. Output Power: 0.322 W EIRP (25.072 dBm) • Antenna Type: Helical (λ/2) • Antenna Dimensions: 16.5 cm. (Length) • Date(s) of Tests: June 27-30, 2000 • Place of Tests: PCTEST Engineering Lab. Columbia, MD, U.S.A. • Report Serial No.: SAR.200626310.CKL 1 Specific Absorption Rate (SAR) is a measure of the rate of energy absorption due to exposure to an RF transmitting source (wireless portable device). 2 IEEE/ANSI Std. C95.1-1992 limits are used to determine compliance with FCC ET Docket 93-62. Fig. 1 SAR Test Setup Test Report S/N: SAR.200626310.CKL SAR Measurement Report Test Date(s): June 26-30, 2000 FCC Part 24 Certification FCC ID: CKLHWP-220 (Tx 1851.25 – 1908.75 MHz) © 2000 PCTEST Lab HYUNDAI PCS CDMA WLL Phone 2 2.1 INTRODUCTION The FCC has adopted the guidelines for evaluating the environmental effects of radiofrequency radiation in ET Docket 93-62 on Aug. 6, 1996 to protect the public and workers from the potential hazards of RF emissions due to FCC-regulated portable devices.[1] The safety limits used for the environmental evaluation measurements are based on the criteria published by the American National Standards Institute (ANSI) for localized specific absorption rate (SAR) in IEEE/ANSI C95.1-1992 Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. (c) 1992 by the Institute of Electrical and Electronics Engineers, Inc., New York, New York 10017.[2] The measurement procedure described in IEEE/ANSI C95.3-1992 Recommended Practice for the Measurement of Potentially Hazardous Electromagnetic Fields - RF and Microwave[3] is used for guidance in measuring SAR due to the RF radiation exposure from the Equipment Under Test (EUT). These criteria for SAR evaluation are similar to those recommended by the National Council on Radiation Protection and Measurements (NCRP) in Biological Effects and Exposure Criteria for Radiofrequency Electromagnetic Fields,” NCRP Report No. 86 (c) NCRP, 1986, Bethesda, MD 20814.[4] SAR is a measure of the rate of energy absorption due to exposure to an RF transmitting source. SAR values have been related to threshold levels for potential biological hazards. 2.2 SAR Definition Specific Absorption Rate (SAR) is defined as the time derivative (rate) of the incremental energy (dU) absorbed by (dissipated in) an incremental mass (dm) contained in a volume element (dV) of a given density (ρ). It is …

Text truncated - open the document above for the full version.

RF Exposure Info

HYUNDAI FCC ID:CKLHWP-220 -- PCS CDMA Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.38 mW/g, SAR (10g): 0.796 mW/g HYUNDAI WLL Model: HWP-220 PCS Mode, Ch.0025 [1851.25MHz]; Conducted Power = 25.0dBm Antenna Extended up-right = normal operating condition; Spacing = 2.5cm from flat phantom to antenna Test Date = 06-28-2000 SAR Tot [mW/g] 1.04E-1 3.13E-1 5.21E-1 7.30E-1 9.39E-1 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHWP-220 -- PCS CDMA Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.12 mW/g, SAR (10g): 0.645 mW/g HYUNDAI WLL Model: HWP-220 PCS Mode, Ch.0600 [1880.00MHz]; Conducted Power = 25.0dBm Antenna Extended up-right = normal operating condition; Spacing = 2.5cm from flat phantom to antenna Test Date = 06-28-2000 SAR Tot [mW/g] 1.78E-1 5.33E-1 8.89E-1 1.24E+0 1.60E+0 PCTEST Engineering Laboratory, Inc. HYUNDAI FCC ID:CKLHWP-220 -- PCS CDMA Body SAR Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 1.32 mW/g, SAR (10g): 0.753 mW/g HYUNDAI WLL Model: HWP-220 PCS Mode, Ch.1175 [1910.25MHz]; Conducted Power = 25.0dBm Antenna Extended up-right = normal operating condition; Spacing = 2.5cm from flat phantom to antenna Test Date = 06-28-2000 SAR Tot [mW/g] 8.46E-2 2.54E-1 4.23E-1 5.92E-1 7.61E-1 PCTEST Engineering Laboratory, Inc.

RF Exposure Info

© 2000 PCTEST Lab HYUNDAI FCC ID: CKLHWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone © 2000 PCTEST Lab HYUNDAI FCC ID: CKLHWP-220 NVLAP Lab Code: 100431-0 PCS CDMA only WLL Phone

RF Exposure Info

Probe ET3DV5 SN:1370 Manufactured: February 1999 Calibrated: February 2000 Calibrated for System DASY3 Page 1 of 8 ET3DV5 SN:1370 Introduction The performance of all probes is measured before delivery. This includes an assessment of the characteristic parameters, receiving patterns as a function of frequency, frequency response and relative accuracy. Furthermore, each probe is tested in use according to a dosimetric assessment protocol. The sensitivity parameters (NormX, NormY, NormZ), the diode compresion parameter (DCP) and the conversion factor (ConvF) of the probe and some of the measurement diagrams are given in the following. The performance of the individual probes varies slightly due to tolerances arising from the manufacturing process. Since the lines are highly resistive (several MOhms), the offset and noise problem is greatly increased if signals in the low μ V range are measured. Accurate measurement below 10 μW/g are possible if the following precautions are taken. 1) check the current grounding with the multimeter 1 , i.e., low noise levels, 2) compensate the current offset 1 , 3) use long integration time (approx. 10 seconds), 4) calibrate 1 before each measurement, 5) persons should avoid moving around the lab while measuring. Since the field distortion caused by the supporting material and the sheath is quite high in the θ direction, the receiving pattern is poor in air. However, the distortion in tissue equivalent material is much less because of its high dielectricity. In addition, the fields induced in the phantoms by dipole structures close to the body are dominently parallel to the surface. Thus, the error due to non-isotropy is much better than 1 dB for dosimetric assessments. The probes are calibrated in the TEM cell ifi 110 although the field distribution in the cell is not very uniform and the frequency response is not very flat. To ensure consistency, a strict protocol is followed. The conversion factor (ConF) between this calibration and the measurement in the tissue simulation solution is performed by comparison with temperature measurements and computer simulations. This conversion factor is only valid for the specified tissue simulating liquids at the specified frequencies. If measurements have to be performed in solutions with other electrical properties or at other frequencies, the conversion factor has to be assessed by the same procedure. As the probes have been constructed with printed resistive lines on ceramic substrates (thick film technique), the probe is very delicate with respect to mechanical shocks. Attention: Do not drop the probe or let the probe collide with any solid object. Never let the robot move without first activating the emergency stop feature (i.e., without first turning the data acquisition electronics on). 1 Feature of the DASY Software Tool. Fig 1: Due to the field distortion caused by the supporting material, the probe has two charac- teristic directions, referred to as angle ψ and θ . Page 2 of 8 ET3DV5 SN:1370 DASY3 - Parameters of Probe: ET3DV5 SN:1370 Sensitivity in Free Space NormX1.58μV/(V/m) 2 NormY1.64μV/(V/m) 2 NormZ1.80μV/(V/m) 2 Diode Compression DCP X96mV DCP Y96mV DCP Z96mV Sensitivity in Tissue Simulating Liquid 450 MHzConvF X6.5extrapolated ε r = 48 ± 5% ConvF Y6.5extrapolated σ =0.50 ± 10%mho/m ConvF Z6.5extrapolated(brain tissue simulating liquid) 900 MHz ConvF X6.0± 10% ε r = 42.5 ± 5% ConvF Y6.0± 10% σ =0.86 ± 10%mho/m ConvF Z6.0± 10%(brain tissue simulating liquid) 1500 MHz ConvF X5.4interpolated ε r = 41 ± 5% ConvF Y5.4interpolated σ =1.32 ± 10%mho/m ConvF Z5.4interpolated(brain tissue simulating liquid) 1800 MHz ConvF X5.1± 10% ε r = 41 ± 5% ConvF Y5.1± 10% σ =1.69 ± 10%mho/m ConvF Z5.1± 10%(brain tissue simulating liquid) Sensor Offset Probe Tip to Sensor Center2.7mm Surface to Probe Tip1.6 ± 0.2mm Page 3 of 8 ET3DV5 SN:1370 Receiving Pattern (φ), θ = 0° f = 30 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 100 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 300 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 900 MHz, TEM cell ifi110 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot Page 4 of 8 ET3DV5 SN:1370 Isotropy Error (φ), θ = 0° -1.00 -0.80 -0.60 -0.40 -0.20 0.00 0.20 0.40 0.60 0.80 1.00 060120180240300360 error[dB] 30 MHz 100 MHz 300 MHz 900 MHz 1800 MHz 2500 MHz f = 1800 MHz, WG R22 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot f = 2500 MHz, WG R26 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 XYZTot Page 5 of 8 ET3DV5 SN:1370 Frequency Response of E-Field ( TEM-Cell:ifi110, Waveguide R22, R26 ) 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 050010001500200025003000 f [MHz] frequency response TEMR22R26 Page 6 of 8 ET3DV5 SN:1370 Dynamic Range f(SAR brain ) ( TEM-Cell:ifi110 ) 1.E+0 1.E+1 1.E+2 1.E+3 1.E+4 1.E+5 1.E+6 1.E+7 0.00010.0010.010.11.10.100. mW/cm 3 μ V not compensatedcompensated -3 -2 -1 0 1 0.00010.0010.010.1110100 mW/cm 3 errror[dB] not compensated diode characteristic compensated relative accuracy Page 7 of 8 ET3DV5 SN:1370 Conversion Factor Assessment Receiving Pattern (φ) ( in brain tissue, z = 5 mm ) -1.00 -0.80 -0.60 -0.40 -0.20 0.00 0.20 0.40 0.60 0.80 1.00 060120180240300360 error[dB] 900 MHz1800 MHz f = 900 MHz, WG R9 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0204060 z[mm] SAR[mW/cm 3 ] / W AnalyticalMeasuremets f = 1800 MHz, WG R22 0.00 0.50 1.00 1.50 2.00 2.50 020…

Text truncated - open the document above for the full version.

RF Exposure Info

1900MHz Muscle Dipole Validation Generic Twin Phantom; Flat Section; Probe: ET3DV5 - SN1370 -- Probe Cal Date 02/00 Med. Parameters 1900 MHz Muscle: σ = 1.85 mho/m ε r = 54.2 ρ = 1.00 g/cm 3 ; Antenna Position -- Out; Crest Factor 1.0 SAR (1g): 10.5 mW/g, SAR (10g): 5.42 mW/g 1900MHz Muscle Dipole Validation (D1900V2 S/N: 502) Frequency: 1900 MHz; Antenna Input Power: 250 [mW] PCTEST Muscle Tissue Simulating Liquid SAR Tot [mW/g] 1.17E+0 3.33E+0 5.64E+0 7.81E+0 1.09E+1 PCTEST Engineering Laboratory, Inc.

RF Exposure Info

August 24, 2000 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 Attn: Mr. Errol Chang/Kwok Chan SUBJECT: HYUNDAI Electronics Industries Co., Ltd. FCC ID: CKLHWP-220 731 Confirmation No.: EA98147 Correspondence Reference No.: 15660 Request for Tech. Info.: 8/17/00 Dear Errol/Kwok: Transmitted herewith, on behalf of HYUNDAI Electronics Industries Co., Ltd. is an amendment provided in response to the request for technical information dated August 17, 2000. 1. Attached is the revised tune-up procedure (24.7dBm ± 0.3dB) and technical description (322mW EIRP), which agree with the max conducted output (+25.0dBm) as indicated in the SAR report. 2. Please find attached the revised instructions for the external panel antenna option. To clarify the MPE categorical exclusion requirements, the output power is 25dBm conducted. The cable loss of the optional external cable is 4dB (@1880MHz). The antenna gain is 10dBi. The EIRP with the external panel antenna is 31dBm or 1.25W. Therefore, the HWP-220 is categorically excluded from routine evaluation per Section 2.1091. 3. Attached is the revised RF exposure warning statement, which will be place towards the front location in the user’s manual. We trust this information is sufficient to issue the grant ASAP. If you have any further questions, please do not hesitate to contact us. cc: HYUNDAI Electronics Industries Co., Ltd.

RF Exposure Info

For more information about RF exposure, please visit the FCC website at www.fcc.gov FCC RF EXPOSURE INFORMATION In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this phone complies with the FCC guidelines and these international standards. To comply with FCC RF exposure requirements, a minimum separation distance of 2.5cm (1inch) must be maintained between the user/bystander and the back of the unit, including the antenna. When using the optional external antenna please note the following precautions: This system is designed to be operated as a fixed system device and must be located either on the roof top site, or up on or near the ceiling away from the user. It must be mounted in a manner to ensure that all user’s and bystanders are kept a minimum of 20cm away from the antennas at all times. WARNING! Read this information before using your phone

Test Report

© 2000 PCTEST Engineering Lab., Inc. PCTEST Engineering Laboratory, Inc. 66606660--B Dobbin Road B Dobbin Road •• Columbia, MD 21045 Columbia, MD 21045 •• U.S.A. U.S.A. TEL (410) 290TEL (410) 290--6652 6652 •• FAX (410) 290 FAX (410) 290--66546654 http://www.pctestlab.comhttp://www.pctestlab.com CERTIFICATE OF COMPLIANCE FCC Part 24 Certification HYUNDAI Electronics Industries Co., Ltd. Dates of Tests: June 27-30, 2000 San 136-1, Ami-Ri, Bubal-Eub Test Report S/N: 24.2006311.CKL Ichon-Si, Kyungki-Do, KOREA 467-701 Test Site: PCTEST Lab, Columbia MD U.S.A. Attn: Mr. Ki Soo Kim, Asst. Manager Quality Assurance Office FCC ID CKLHWP-220 APPLICANT HYUNDAI Electronics Industries Co., Ltd. Classification: Licensed Base Station for Part 24 (PCB) FCC Rule Part(s): §24(E), §2 EUT Type: PCS CDMA WLL Phone Trade Name/Model(s): HYUNDAI HWP-220 Frequency Range: Tx: 1851.25 – 1908.75MHz Rx: 1931.25 – 1988.75MHz Max. RF Output Power: 0.322 Watts EIRP (25.072 dBm) Frequency Tolerance: 0.00025% (2.5 ppm) Emission Designator: 1M25F9W This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in §2.947. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a) 200104032.CKL Certification © 2000 PCTEST Engineering Laboratory, Inc.FCC Part 24 TABLE OF CONTENTS ATTACHMENT A: COVER LETTER(S) ATTACHMENT B: ATTESTATION STATEMENT(S) ATTACHMENT C: TEST REPORT 1.1 SCOPE 1 2.1 INTRODUCTION (SITE DESCRIPTION) 2 3.1 INSERTS PER §2.1033 3 4.1 DESCRIPTION OF TESTS 4-5 5.1 TEST DATA (Equivalent Isotropic Radiated Power) 6 6.1 TEST DATA (RADIATED) 7-9 7.1 TEST DATA (FREQUENCY STABILITY) 10-11 8.1 PLOTS OF EMISSIONS 12 9.1 LIST OF TEST EQUIPMENT 13 10.1 SAMPLE CALCULATIONS 14 11.1 CONCLUSION 15 ATTACHMENT D: TEST PLOTS ATTACHMENT E: FCC ID LABEL & LOCATION ATTACHMENT F: TEST SETUP PHOTOGRAPHS ATTACHMENT G: EXTERNAL PHOTOGRAPHS ATTACHMENT H: INTERNAL PHOTOGRAPHS ATTACHMENT I: BLOCK DIAGRAM(S) ATTACHMENT J: SCHEMATIC DIAGRAM(S) ATTACHMENT K: PARTS LIST/TUNE UP PROCEDURE ATTACHMENT L: OPERATIONAL DESCRIPTION ATTACHMENT M: USER’S MANUAL ATTACHMENT N: SAR MEASUREMENT REPORT ATTACHMENT O: SAR TEST DATA ATTACHMENT P: SAR TEST SETUP PHOTOGRAPHS ATTACHMENT Q: DIPOLE VALIDATION ATTACHMENT R: PROBE CALIBRATION Test Report S/N: 24.2006311.CKL FCC Part 24 Dates of Tests: June 27-30, 2000 Certification © 2000 PCTEST Lab HYUNDAI PCS CDMA WLL Phone 1 FCC ID: CKLHWP-220 (Tx 1851.25 – 1908.75 MHz) MEASUREMENT REPORT 1.1 Scope Product Evaluation and determination of electromagnetic emissions (EME) of radio frequency devices including intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal Communications Commission. §2.1033 General Information Applicant Name: HYUNDAI Electronics Industries Co., Ltd. Address: San 136-1, Ami-Ri, Bubal-Eub Ichon-Si, Kyungki-Do, KOREA 467-701 Attention: Mr. Ki Soo Kim, Asst. Manager Quality Assurance Office • FCC ID: CKLHWP-220 • Trade Name(s): HYUNDAI • Model(s): HWP-220 • Quantity: Quantity production is planned • Emission Designator: 1M25F9W • Max. RF Output Power: 0.322 W EIRP (25.072 dBm) • AC Power Adapter: HYUNDAI Model: CP-402 [Output: 12VDC, 2A] • FCC Classification: Licensed Base Station for Part 24 (PCB) • Equipment (EUT) Type: PCS CDMA WLL Phone • FCC Rule Part(s): § 24(E), §2 • Application Type: Certification • Modulation: CDMA • Tx Frequency Range: 1851.25 – 1908.75 MHz • Rx Frequency Range: 1931.25 – 1988.75 MHz • Frequency Tolerance: ± 2.5 ppm • Dates of Tests: June 27-30, 2000 • Place of Tests: PCTEST Lab, Columbia, MD U.S.A. 200104032.CKL Test Report S/N: 24.2006311.CKL FCC Part 24 Dates of Tests: June 27-30, 2000 Certification © 2000 PCTEST Lab HYUNDAI PCS CDMA WLL Phone 2 FCC ID: CKLHWP-220 (Tx 1851.25 – 1908.75 MHz) 2.1 INTRODUCTION These measurement tests were conducted at PCTEST Engineering Laboratory, Inc. facility in New Concept Business Park, Guilford Industrial Park, Columbia, Maryland. The site address is 6660-B Dobbin Road, Columbia, MD 21045. The test site is one of the highest points in the Columbia area with an elevation of 390 feet above mean sea level. The site coordinates are 39° 11'15" N latitude and 76° 49'38" W longitude. The facility is 1.5 miles North of the FCC laboratory, and the ambient signal and ambient signal strength are approximately equal to those of the FCC laboratory. There are no FM or TV transmitters within 15 miles of the site. The detailed description of the measurement facility was found to be in compliance with the requirements of § 2.948 according to ANSI C63.4 on October 19, 1992. PCTEST Lab is recognized under the National Voluntary Laboratory Accreditation Program for satisfactory compliance with criteria established in Title 15, Part 285 Code of Federal Regulations. These criteria encompass the requirements of ISO/IEC Guide 25 and the relevant requirements of ISO 9002 (ANSI/ASQC Q92-1987) as suppliers of calibration or test results. The Scope of PCTEST Accreditation is for Electromagnetic Compatibility and Telecommunications and FCC. 2.2 PCTEST Location The map at right shows the location of the PCTEST Lab, its proximity to the FCC Lab, the Columbia vicinity area, the Baltimore- Washington International (BWI) airport, and the city of Baltimore, and the Washington, D.C. area. (see Figure 1). Figure 1. Map of the Greater Baltimore and Metropolitan Washington, D.C. area. Test Report S/N: 24.2006311.CKL FCC Part 24 Dates of Tests: June 27-30, 2000…

Text truncated - open the document above for the full version.

Test Setup Photos

© 2000 PCTEST Lab FCC ID: CKLHWP-220 NVLAP Lab Code: 100431-0 HYUNDAI Electronics Industries, Co., Ltd. © 2000 PCTEST Lab FCC ID: CKLHWP-220 NVLAP Lab Code: 100431-0 HYUNDAI Electronics Industries, Co., Ltd.

Contact Information

Applicant

Bong Jae Hur(Manager, QA Office)
[email protected]82 336-30-3280Fax: 82 336-3003265

Technical Contact

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652

6660-B Dobbin Road · Columbia, Maryland · United States

Non-Technical Contact

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652

Test Firm

PCTEST Engineering Laboratory, Inc.Randy Ortanez
[email protected]410-290-6652Fax: 410-290-6654

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1241.85 GHz - 1.91 GHz322.00 mW1M25F9W2.5000000000 ppm
Confidentiality
Long Term

Other Applications from Hyundai Electronics Industries Co Ltd

Single-Mode Cellular CDMA WLL Terminal - FCC ID CKLHWP-120 - Hyundai Electronics Industries Co Ltd
CKLHWP-120

Single-Mode Cellular CDMA WLL Terminal

Feb 15, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Tri-Mode Dual Band Analog/PCS Phone (AMPS/CDMA) - FCC ID CKLTX-20B - Hyundai Electronics Industries Co Ltd
CKLTX-20B

Tri-Mode Dual Band Analog/PCS Phone (AMPS/CDMA)

Jan 28, 2001

Equipment Class

PCE - PCS Licensed Transmitter held to ear
CKLA526

15-inch Color Monitor

Dec 28, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CKLC21R05110

21-inch Color Monitor

Dec 28, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
17" CRT MONITOR - FCC ID CKLC17F06090 - Hyundai Electronics Industries Co Ltd
CKLC17F06090

17" CRT MONITOR

Dec 21, 2000

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral