FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ALPS ALPINE CO., LTD./
  3. CWTR74P0

CWTR74P0Passive Keyless Entry

ALPS ALPINE CO., LTD.
Passive Keyless Entry - FCC ID CWTR74P0 - ALPS ALPINE CO., LTD.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
May 14, 2014
Application Purpose
Original Equipment
Date of Application
May 14, 2014
Equipment Note
Passive Keyless Entry
Frequency Range
315.00000000 - 315.00000000
Company
ALPS ALPINE CO., LTD.
Country
Japan

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Since this device is always used with vehicle, it is not sold to general end users separately. Therefore there is no user manual of this device by alone. The following statements must be described on the user manual of the vehicle; This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the userโ€™s authority to operate the equipment.

External Photos

And Machanical KeyWith Machanical Key ่ฃฝๅ“ๅค–่ฆณๅ†™็œŸ External Photo 3 Switch Type 4 Switch Type M Mark LP Mark ใƒใƒชใ‚จใƒผใ‚ทใƒงใƒณ้•ใ„ๅ†™็œŸ photos of each types

ID Label/Location Info

ไบไžŠไ„ไžŠเน‰เผณ ใปฒใปฏใปฏใปŒใปตใปฐใปŒใปฆใปŒใปฏใผƒใผ€ใปพใปฃใป ใปผใปœใปธใผใผŸใผ‘ใผžใปŒใปนใผใผžใผ—ใผ•ใผšใผ“ ใปนใปปใปฐใปฑใปธใปŒใปบใปญใปนใปฑใปฆใปพใปฃใป ใปผใปœ ใปญใปธใปผใปฟใปŒใปฑใปธใปฑใปฏใผ€ใปพใปตใปฏใปŒใปฏใปปใปšใป˜ใปธใผ€ใปฐใปš ใปœใปœใปฃใป™ใผ„ใผ„ใผ„ใผ„ใผ„ใผ„ ใปฒใปฏใปฏใปŒใปตใปฐใปŒใปฆใปŒใผ„ใผ„ใผ„ใผ„ใผ„ใผ„ใผ„ใผ„ ใปนใปปใปฐใปฑใปธใปŒใปบใปญใปนใปฑใปฆใปพใปฃใป ใปผใปœ ใปญใปธใปผใปฟใปŒใปฑใปธใปฑใปฏใผ€ใปพใปตใปฏใปŒใปฏใปปใปšใป˜ใปธใผ€ใปฐใปš ใปœใปœใปฃใผ…ใผใผใปธใป–ใป–ใป–ใป– 007-XXXXXX CWTR74P0 ไž‰แชฅแฎใŸแผผแผฒไ›พใ„†เพโ’เพ•ไ›ฟไšธใ„†เพเฝถแš“แš‹ไšธเฏœเญšไ›ฅไœœไ›ฏใ„†เพโ’ เพ•ไœขใ‚ฐใ•ไ›ฉไœ› ไž‰แขใบไฌไžŠไœฝไ›พโ”คแš„ไ›ฟ3mmเฏจเญ–

Internal Photos

ๅ›ž่ทฏใ‚ซใƒใƒผๅ–ใ‚Šๅค–ใ—ใŸ็Šถๆ…‹ Removing Cover ้›ปๆฑ ๅ–ใ‚Šๅค–ใ—ใŸ็Šถๆ…‹ Removing Battery ่ฃฝๅ“ ๅ†…้ƒจ้…็ฝฎ Internal Photo RFๅ›ž่ทฏ้ƒจ RF Circuit ๅŸบๆฟใƒ‘ใ‚ฟใƒผใƒณใ‚ขใƒณใƒ†ใƒŠ Pattern Antenna LFใ‚ณใ‚คใƒซ LF Coil Internal Antennas [X,Y, Z โ€ antenna] described in Block Diagram are LF Coils and located as follows. They are not for radio transmitting . ใ‚ซใƒใƒผๅ†…ๅด Reverse side of Cover

Test Report

Test report No. : 10242184H Page : 2 of 18 Issued date : May 9, 2014 FCC ID : CWTR74P0 UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 REVISION HISTORY Original Test Report No.: 10242184H Revision Test report No. Date Page revised Contents - (Original) 10242184H May 9, 2014 - - Test report No. : 10242184H Page : 3 of 18 Issued date : May 9, 2014 FCC ID : CWTR74P0 UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 SECTION 2: Equipment under test (E.U.T.) ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 4 SECTION 3: Test specification, procedures & resultsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 SECTION 4: Operation of E.U.T. during testing ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission) 9 SECTION 6: Automatically deactivate ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 SECTION 7: -20dB and 99% Occupied Bandwidth ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 APPENDIX 1: Data of EMI test ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 11 Automatically deactivate................................................................................................................... 11 Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 12 -20dB and 99% Occupied Bandwidth ............................................................................................... 13 Duty Cycle ........................................................................................................................................ 14 APPENDIX 2: Test Instruments ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 APPENDIX 3: Photographs of test setup ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 16 Radiated emission ............................................................................................................................. 16 Worst case position ........................................................................................................................... 17 Test report No. : 10242184H Page : 4 of 18 Issued date : May 9, 2014 FCC ID : CWTR74P0 UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Alps Electric Co., Ltd. Address : 6-3-36, Nakazato, Furukawa, Osaki-city, Miyagi-pref, 989-6181, Japan Telephone Number : +81-229-23-5111 Facsimile Number : +81-229-23-5129 Contact Person : Toru Kinoshita SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Passive Keyless Entry (Hand Unit) Model No. : R74P0 Serial No. : Refer to Section 4, Clause 4.2 Receipt Date of Sample : April 29, 2014 Country of Mass-production : China Condition of EUT : Engineering prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Model No: R74P0 (referred to as the EUT in this report) is the Passive Keyless Entry (Hand Unit). General Specification Clock frequency in the system : 18.370366MHz Radio Specification Equipment Type : Transceiver Frequency of operation : 315MHz Type of modulation : FSK Antenna Type : PWB Pattern antenna Method of Frequency Generation : Crystal + PLL IC Operating voltage (inner) : DC 3.0V Operating Temperature : -30 to +60 deg. C * Original model No.: R74P0 has 4 switches. Variation models have 2 switches and 3 switches. The difference of Original mode and Variation models is only the number of switches. They are completely identical in EMC characteristics. Therefore the test was performed with the representative original type which was the worst one. Test report No. : 10242184H Page : 5 of 18 Issued date : May 9, 2014 FCC ID : CWTR74P0 UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test Specification Test Specification : FCC Part 15 Subpart C: 2014, final revised on March 6, 2014 and effective April 7, 2014 Title : FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators Section 15.231 Periodic operation in the band 40.66 - 40.70MHz and above 70MHz 3.2 Procedures and results Item Test Procedure Specification Worst margin Results Remarks Conducted emission FCC: ANSI C63.4:2003 7. AC powerline conducted emission measurements FCC: Section 15.207 N/A N/A *1) - IC: RSS-Gen 7.2.4 IC: RSS-Gen 7.2.4 Automatically Deactivate FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.231(a)(1) N/A Complied Radiated IC: - IC: RSS-210 A1.1.1 Electric Field Strength of Fundamental Emission FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.231(b) 0.2dB 315.000MHz Horizontal, PK with Duty factor Complied Radiated IC: RSS-Gen 4.8 IC: RSS-210 A1.1.2 Electric Field Strength of Spurious Emission FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.205 Section 15.209 Section 15.231(b) 0.1dB 3150.000MHz Horizontal, PK with Duty factor Complied Radiated IC: RSS-Gen 4.9 IC: RSS-210 A1.1.2, 2.5.1 RSS-Gen 7.2.5 -20dB Bandwidth FCC: ANSI C63.4:2003 13. Measurement of intentional radiators FCC: Section 15.231(c) N/A Complied Radiated IC: - IC: Reference data Note: UL Japan, Inc.โ€™s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422. *1) The test is not applicable since the EUT does not hโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 10242184H Page : 16 of 18 Issued date : May 9, 2014 FCC ID : CWTR74P0 UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Radiated emission Photo 1 Photo 2 Test report No. : 10242184H Page : 17 of 18 Issued date : May 9, 2014 FCC ID : CWTR74P0 UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst case position (Below 1GHz : Horizontal: X-axis/Vertical : Z-axis) (Above 1GHz : Horizontal: Z-axis/Vertical : Y-axis) X-axis Y-axis Z-axis Test report No. : 10242184H Page : 18 of 18 Issued date : May 9, 2014 FCC ID : CWTR74P0 UL Japan, Inc. Ise HQ EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst case position With Key (Worst) Without Key End of Report

Contact Information

Applicant

Yuji Ouchi
[email protected]229 23 5111Fax: 229 24 6334

Technical Contact

UL Japan, Inc.Takashi Nakazawa
[email protected]81-596-24-8999

4383-326 Asama-cho, Ise-shi ยท Mie-ken ยท Japan

Test Firm

UL Japan, Inc. Head office EMC Lab.Tetsuya Hashimoto
[email protected]+81-596-24-8116Fax: +81-596-24-8095

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from ALPS ALPINE CO., LTD.

CWTUMNZ1A2

5G Communication Module

Oct 06, 2024

Equipment Class

PCB - PCS Licensed Transmitter
CWTB2311

Automatic access gesture control

Apr 09, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Sensor for opening and closing doors in cars - FCC ID CWTB230X - ALPS ALPINE CO., LTD.
CWTB230X

Sensor for opening and closing doors in cars

Feb 07, 2024

Equipment Class

FDS - Part 15 Field Disturbance Sensor
Automatic access gesture control - FCC ID CWTB2211 - ALPS ALPINE CO., LTD.
CWTB2211

Automatic access gesture control

Dec 26, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
KEYLESS ENTRY SYSTEM - FCC ID CWTB1G496 - ALPS ALPINE CO., LTD.
CWTB1G496

KEYLESS ENTRY SYSTEM

Aug 01, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter