FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ALPS ALPINE CO., LTD./
  3. CWTWB1U818

CWTWB1U818Passive Entry System (Hand Unit)

ALPS ALPINE CO., LTD.
Passive Entry System (Hand Unit) - FCC ID CWTWB1U818 - ALPS ALPINE CO., LTD.
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
Feb 23, 2010
Application Purpose
Original Equipment
Date of Application
Feb 23, 2010
Equipment Note
Passive Entry System (Hand Unit)
Frequency Range
314.97500000 - 314.97500000
Company
ALPS ALPINE CO., LTD.
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

Internal Photos

Test Report

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CONTENTS 1. PREFACE 2. PASSSIVE ACCSESS ENTRY FUNCTIONALITY 2.1. Door Unlocking 2.2. Engine Start 2.3. Engine Stop 2.4. Door Locking (Push switch) 3. ACTIVE ACCESS ENTRY FUNCTIONALITY 3.1. Door Unlocking 3.2. Engine Start 3.3. Engine Stop 3.4. Door Locking 3.5. Trunk Open 4. ENTRY SYSTEM OPTIONS 4.1. System Schematic 4.2. Modules 4.2.1. FOB ECU 4.2.2. Entry System ECU 5. SYSTEM CHARACTERISTICS 5.1. Antenna Areas 5.2. Exciter Locations 5.3. Switch Input Locations (Door handle) 6. ELECTRICAL CHARACTERISTICS 6.1. FOB 6.2. Entry System ECU FCC WARNING NOTICE 1.Preface This document describes the requirements and operation of the Passive Entry System. However, this document is especially for the Entry system ECU (acronym for Electric Control Unit) and the FOB. The FOB consists the following functionality for passive access and active access: • • • • • • • • • • • • • • • • Door unlocking / locking (however, only for request by means of switch operation) Trunk open (however, only for request by means of switch operation) LF decoding RF encoding Communication data encryption (cryptograph, anti-collision, rolling code and stuff) And the entry system ECU consists of the following functionality: Door unlocking / locking Trunk open Engine start (/ stop) LF encoding RF encoding Communication data encryption (cryptograph, anti-collision, rolling code and stuff) LF antenna unit control Communication with the node ECUs connected to the body bus (e.g. CAN, J1850, customer dependent bus) As a further function, both the FOB and the entry system ECU provides the following function: Learning mode for programming the manufacturing data and stuff Data locking and password protection Diagnostic (based upon ISO9141 if required) 2.Passsive Accsess Entry Functionality A handle sw located on, for example the door handles, mirrors and trunk lid will be used for proximity check if user is in neighborhood of the vehicle. The switch input will trigger for unlocking and open the doors and trunk. Door Handle SW Figure 1 2.1.Door Unlocking User pushes door handle sw. • • • • • ECU sends LF-challenge via exterior antenna. FOB sends RF-response to the ECU. Door unlocking status is engaged. Doors are opened. RF LF FOB Figure 2 2.2.Engine Start User operates the engine start knob. • • • • • • ECU sends LF-challenge via interior antenna. FOB sends RF-response to the ECU. Immobilizer ECU receives and authorize the response. Engine controller ECU receives the authorization for engine strat. FOB RF LF Start the engine. Figure 3 2.3.Engine Stop User operates the engine stop knob. • • • • ECU communicates with the other ECU for engine start request. Engine controller ECU receives the request. Stop the engine Figure 4 2.4.Door Locking (Push switch) User closes the door and pushes the switch (sensing of door locking switch). • • • • • • ECU sends LF-challenge via exterior antenna. FOB sends RF-response to the ECU. Door locking status is engaged. Doors are locked. (Indicates the door locking status by means of Flasher / Buzzer or stuff) Figure 5 3.Active Access Entry Functionality 3.1.Door Unlocking Same functionality as the current one. 3.2.Engine Start This function does not effect on the active entry system. 3.3.Engine Stop This function does not have influence on the active entry system. 3.4.Door Locking Same functionality as the current one. 3.5.Trunk Open Same functionality as the current one. 4.Entry System Options 4.1.System Schematic 4.2.Modules Body Bus OTHER ECUS LF (>2Kbps) Local Bus ECUECUECU 314.975MHz RF Tuner Tuner signal 125kHz FOB ENTRY SYSTEM ECU RF (>2Kbps) 4.2.1.FOB ECU 314.975 MHz 125kHz Emergency key (Transponder) Panic Unlock Lock Z FOB RF Amp LF Amp Y X ASIC 4.2.2.Entry System ECU Tuner signal Interior Antenna LF Excite r LF Excite r LF Excite r LF Excite r Room1 Dr As Trunk Exterior Antenna 125kHz Dr : Driver Door Antenna As : Assist Door Antenna Trunk : Bumper Antenna Room1: Console Antenna Room2: Inst. Antenna Room3: Trunk Antenna LF Excite r LF Excite r Room2 Room3 Local Bus Body Bus Push knob (Engine start knob) Dr Door handle As Door handle Trunk MCU ENTRY SYSTEM ECU 5.System Characteristics 5.1.Antenna Areas Exterior operating range: 0.8m to 1.5m Interior operating range: Only inside the car Number of the exterior exciters : typ.3, however, it is depending on the type of the vehicle. Number of the interior exciters: max.4 (min.2) Dr Interior Exterior As Back Figure 6 Exterior antenna functionality: Unlock / lock doors. • • • • • • Open trunk. Activate / deactivate alarm system. Activate immobilizer Interior antenna functionality: Deactivate immobilizer Engine start 5.2.Exciter Locations Exterior exciters: 3 doors Interior exciters: 1 Center Console 2 Inst panel 3 Trunk Bumper Interior Exterior Dr As Figure 7 Antenna location can be different among of type of the vehicle (e.g. coupe, sedan, mini and stuff). 5.3.Switch Input Locations (Door handle) There are some switches, for instance the door handle contact switch will be used as a triggering for unlocking and open the door. Switch inputs: 3 doors Dr As Trunk Figure 8 Switch inputs can be different among of type of the vehicle (e.g. coupe, sedan, mini and stuff). 6.Electrical Characteristics 6.1.FOB • • • • • • • • • • • • ASK / FSK modulation Transmission:FSK Reception:ASK Operating supply voltage 2.5V ~ 3.3V (3.0V Battery) Operating supply current < 35mA Stand-by current < 10.0uA Operating ambient temperature -10 o C to +60 o C Antenna direction 3-Dimension (X, Y, Z), to be considered Battery life 2 Years (Low battery indication is considered) 6.2.Entry System ECU Operating supply voltage 9.0V ~ 16.0V Operating supply current < 55mA Stand-by current < 4.0mA Operating ambient temperature -30 o C to +80 o C FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTICE This device complies with Part 15 of the FCC Rules and RSS-Gen of IC Rules. Operatio…

Text truncated - open the document above for the full version.

External Photos

External Photo ALPS ELECTRIC CO.,LTD. Passive Entry System (Hand Unit) [Model: TWB1U818] Front Rear External Photo ALPS ELECTRIC CO.,LTD. Passive Entry System (Hand Unit) [Model: TWB1U818] Top Bottom External Photo ALPS ELECTRIC CO.,LTD. Passive Entry System (Hand Unit) [Model: TWB1U818] Right Left

Test Setup Photos

Test report No. : 30CE0171-HO-01-A-R1 Page : 12 of 22 Issued date : February 2, 2010 Revised date : February 24, 2010 FCC ID : CWTWB1U818 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 APPENDIX 1: Photographs of test setup Radiated emission Photo 1 Photo 2 Test report No. : 30CE0171-HO-01-A-R1 Page : 13 of 22 Issued date : February 2, 2010 Revised date : February 24, 2010 FCC ID : CWTWB1U818 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst case position (Horizontal: X-axis/Vertical : Y-axis) X-axis Y-axis Z-axis Test report No. : 30CE0171-HO-01-A-R1 Page : 14 of 22 Issued date : February 2, 2010 Revised date : February 24, 2010 FCC ID : CWTWB1U818 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 Worst case position Mechanical Key (Not Inserted) Worst Mechanical Key (Inserted)

Contact Information

Applicant

Yuji Ouchi
[email protected]229 23 5111Fax: 229 24 6334

Technical Contact

UL Japan IncMakoto Kosaka
[email protected]81-596-24-8116

4383-326 Asama-cho · Ise-shi, Mie-ken · Japan

Non-Technical Contact

UL Japan IncYoshinobu Asai
[email protected]81-596-24-8116

Test Firm

UL Japan, IncMitsuru Fujimura
[email protected]81-596-24-8116Fax: 81-596-24-8124

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231314.975 MHz - 314.975 MHz-
Confidentiality
Long Term

Other Applications from ALPS ALPINE CO., LTD.

CWTUMNZ1A2

5G Communication Module

Oct 06, 2024

Equipment Class

PCB - PCS Licensed Transmitter
CWTB2311

Automatic access gesture control

Apr 09, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Sensor for opening and closing doors in cars - FCC ID CWTB230X - ALPS ALPINE CO., LTD.
CWTB230X

Sensor for opening and closing doors in cars

Feb 07, 2024

Equipment Class

FDS - Part 15 Field Disturbance Sensor
Automatic access gesture control - FCC ID CWTB2211 - ALPS ALPINE CO., LTD.
CWTB2211

Automatic access gesture control

Dec 26, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
KEYLESS ENTRY SYSTEM - FCC ID CWTB1G496 - ALPS ALPINE CO., LTD.
CWTB1G496

KEYLESS ENTRY SYSTEM

Aug 01, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter