ζΉθ¨οΌ2014/01/21 User Manual Since this device is always used with vehicle, it is not sold to general end users separately. Therefore there is no user manual of this device by alone. The following statements must be described on the user manual of the vehicle; FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the userβs authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Photograph_TWD1G776 External photograph
Internal photograph Photograph_TWD1G776 Antenna
Test report No. : 10620455H-R1 Page : 2 of 15 Issued date : January 20, 2015 Revised date : January 29, 2015 FCC ID : CWTWD1G776 UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 REVISION HISTORY Original Test Report No.: 10620455H Revision Test report No. Date Page revised Contents - (Original) 10620455H January 20, 2015 - - 1 10620455H-R1 January 29, 2015 P.1, 5 Update of FCC15 version 1 10620455H-R1 January 29, 2015 P.5 Deleted RSS-Gen section number in section 3.2 Test report No. : 10620455H-R1 Page : 3 of 15 Issued date : January 20, 2015 Revised date : January 29, 2015 FCC ID : CWTWD1G776 UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ...................................................................................... 4 SECTION 2: Equipment under test (E.U.T.) ........................................................................ 4 SECTION 3: Test specification, procedures & results ......................................................... 5 SECTION 4: Operation of E.U.T. during testing ................................................................. 7 SECTION 5: Radiated Emission ............................................................................................ 8 APPENDIX 1: Data of EMI test ............................................................................................. 9 Radiated Emission .............................................................................................................................. 9 APPENDIX 2: Test instruments ........................................................................................... 13 APPENDIX 3: Photographs of test setup............................................................................. 14 Radiated Emission ............................................................................................................................ 14 Worst Case Position (Horizontal: X-axis/ Vertical:X-axis) ........................................................... 15 Test report No. : 10620455H-R1 Page : 4 of 15 Issued date : January 20, 2015 Revised date : January 29, 2015 FCC ID : CWTWD1G776 UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : ALPS ELECTRIC CO., LTD. Address : 6-3-36, Nakazato, Furukawa, Osaki-city, Miyagi-pref, 989-6181, Japan Telephone Number : +81-229-23-5111 Facsimile Number : +81-229-23-5129 Contact Person : Toshiya Ikarashi SECTION 2: Equipment under test (E.U.T.) Type of Equipment : TPMS/RKE Receiver Model No. : TWD1G776 Serial No. : Refer to Section 4, Clause 4.2 Receipt Date of Sample : December 24, 2014 Country of Mass-production : Japan Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product description Model No: TWD1G776 (referred to as the EUT in this report) is the TPMS/RKE Receiver. Feature of EUT : This TPMS/RKE Receiver receives and detects RF signal from keyless transmitter, and performs locking or unlocking of a door. It also receives RF signal from TPMS censor, warns trouble of air pressure. General Specification Clock frequencies in the system : 17.77MHz Radio Specification Frequency of operation : 433.92MHz Type of modulation : FSK Antenna Type : Built-in transformation whip antenna Method of Frequency Generation : Crystal, PLL Local frequency : 433.6896MHz IF frequency : 230kHz Operating voltage (inner) : DC 9.0V to 16.0V Operating Temperature : -30 deg. C to +80 deg. C FCC15.111(b) The receiving antenna (of this EUT) is installed inside the EUT and cannot be removed (permanently attached). Therefore, Radiated emission test was performed. Test report No. : 10620455H-R1 Page : 5 of 15 Issued date : January 20, 2015 Revised date : January 29, 2015 FCC ID : CWTWD1G776 UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test specification Test specification : FCC Part 15 Subpart B: 2015, final revised on January 21, 2015 Title : FCC 47CFR Part15 Radio Frequency Device Subpart B Unintentional Radiators * The revision on January 21, 2015 does not affect the test specification applied to the EUT. 3.2 Procedures and results Item Test Procedure Limits Deviation Worst margin Result Conducted emission FCC: ANSI C63.4: 2003 7. AC powerline conducted emission measurements FCC: Part 15 Subpart B 15.107(a) N/A *1) N/A N/A Radiated emission FCC: ANSI C63.4: 2003 8. Radiated emission measurements FCC: Part 15 Subpart B 15.109(a) N/A 8.7dB 36.559MHz Vertical, QP Complied *Note: UL Japan, Incβs EMI Work Procedure 13-EM-W0420. *1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power line. 3.3 Addition to standard No addition, exclusion nor deviation has been made from the standard. 3.4 Uncertainty EMI The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2. Test room (semi- anechoic chamber) Radiated emission (3m*)(+dB) (1m*)(+dB) (0.5m*)(+dB) 9kHz -30MHz 30MHz -300MHz 300MHz -1GHz 1GHz -10GHz 10GHz -18GHz 18GHz -26.5GHz 26.5GHz -40GHz No.1 4.0dB 5.1dB 5.0dB 5.1dB 6.0dB 4.9dB 4.3dB No.2 3.9dB 5.2dB 5.0dB 4.9dB 5.9dB 4.7dB 4.2dB No.3 4.3dB 5.1dB 5.2dB 5.2dB 6.0dB 4.8dB 4.2dB No.4 4.6dB 5.2dB 5.0dB 5.2dB 6.0dB 5.7dB 4.2dB *3m/1m/0.5m = Measurement distance Radiated emission test(3m) The data listed in this test report has enough margin, more than the site margin. Test report No. : 10620455H-R1 Page : 6 of 15 Issued date : January 20, 2015 Revised date : January β¦
Text truncated - open the document above for the full version.
Test report No. : 10620455H-R1 Page : 14 of 15 Issued date : January 20, 2015 Revised date : January 29, 2015 FCC ID : CWTWD1G776 UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Radiated Emission Photo 1 Photo 2 Test report No. : 10620455H-R1 Page : 15 of 15 Issued date : January 20, 2015 Revised date : January 29, 2015 FCC ID : CWTWD1G776 UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst Case Position (Horizontal: X-axis/ Vertical:X-axis) X-axis Y-axis Z-axis End of Report
4383-326 Asama-cho, Ise-shi Β· Mie-ken Β· Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.92 MHz - 433.92 MHz | - |
5G Communication Module
Equipment Class
PCB - PCS Licensed TransmitterAutomatic access gesture control
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Sensor for opening and closing doors in cars
Equipment Class
FDS - Part 15 Field Disturbance Sensor
Automatic access gesture control
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
KEYLESS ENTRY SYSTEM
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter