Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
USER MANUAL_TWD1U848-1/2
USER MANUAL_TWD1U848-1/2
Photograph TWD1U848
Label Drawing LabelContents of Marking detaled/刻印部詳細 (69) Serial number label Identification mark/機種識別マーク Customer part number/顧客部品番号 (15) (43)
Internal photograph Photograph_TWD1U848 Antenna Soldering
Test report No. : 10017512H-A Page : 2 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 REVISION HISTORY Original Test Report No.: 10017512H-A Revision Test report No. Date Page revised Contents - (Original) 10017512H-A June 24, 2013 - - Test report No. : 10017512H-A Page : 3 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ...................................................................................... 4 SECTION 2: Equipment under test (E.U.T.) ........................................................................ 4 SECTION 3: Test specification, procedures & results ......................................................... 5 SECTION 4: Operation of E.U.T. during testing ................................................................. 7 SECTION 5: Radiated Emission ............................................................................................ 8 APPENDIX 1: Data of EMI test ............................................................................................. 9 Radiated Emission ............................................................................................................................ 9 APPENDIX 2: Test instruments ........................................................................................... 13 APPENDIX 3: Photographs of test setup............................................................................. 14 Radiated Emission .......................................................................................................................... 14 Worst Case Position (Horizontal: X-axis/ Vertical:Y-axis) ........................................................ 16 Test report No. : 10017512H-A Page : 4 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 1: Customer information Company Name : Alps Electric Co., Ltd. Address : 6-3-36, Nakazato, Furukawa, Osaki-city, Miyagi-pref, 989-6181, Japan Telephone Number : +81-229-23-5111 Facsimile Number : +81-229-24-6334 Contact Person : Toru Kinoshita SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : TPMS/KEYLESS RECEIVER Model No. : TWD1U848 Serial No. : Refer to Section 4, Clause 4.2 Receipt Date of Sample : June 8, 2013 Country of Mass-production : Estados Unidos Mexicanos Condition of EUT : Production prototype (Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product description Model No: TWD1U848 (referred to as the EUT in this report) is the TPMS/KEYLESS RECEIVER. General Specification Feature of EUT : This TPMS TUNER CONT receives and detects RF signal from remote control, and performs locking or unlocking of a door. It also receives RF signal from TPMS censor, warns trouble of air pressure. Clock frequency in the system : 35.55MHz (Oscillator circuit) Radio Specification Frequency of operation : 315MHz Oscillator Frequency : 29.5098MHz Local Oscillator Frequency : 314.77MHz Intermediate Frequency : 230kHz Type of modulation : ASK Operating voltage : DC 9 to 16V Antenna Type : Built-in Antenna Operating Temperature : -30 to +80 deg. C FCC15.111(b) The receiving antenna (of this EUT) is installed inside the EUT and cannot be removed (permanently attached). Therefore, Radiated emission test was performed. Test report No. : 10017512H-A Page : 5 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 SECTION 3: Test specification, procedures & results 3.1 Test specification Test specification : FCC Part 15 Subpart B: 2012, final revised on December 27, 2012 and effective January 28, 2013 Title : FCC 47CFR Part15 Radio Frequency Device Subpart B Unintentional Radiators 3.2 Procedures and results Item Test Procedure Limits Deviation Worst margin Result Conducted emission FCC: ANSI C63.4: 2003 7. AC powerline conducted emission measurements FCC: Part 15 Subpart B 15.107(a) N/A *1) N/A N/A IC: RSS-Gen 7.2.4 IC: RSS-Gen 7.2.4 Radiated emission FCC: ANSI C63.4: 2003 8. Radiated emission measurements FCC: Part 15 Subpart B 15.109(a) N/A 3.9dB 431.863MHz Vertical, QP Complied IC: RSS-Gen 4.10 IC: RSS-Gen 6.1 *Note: UL Japan, Inc’s EMI Work Procedure 13-EM-W0420. *1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power line. 3.3 Addition to standard No addition, exclusion nor deviation has been made from the standard. 3.4 Uncertainty EMI The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2. Test room (semi- anechoic chamber) Radiated emission (3m*)(+dB) (1m*)(+dB) (0.5m*)(+dB) 9kHz -30MHz 30MHz -300MHz 300MHz -1GHz 1GHz -10GHz 10GHz -18GHz 18GHz -26.5GHz 26.5GHz -40GHz No.1 4.3dB 5.0dB 5.1dB 4.9dB 5.8dB 4.4dB 4.3dB No.2 4.3dB 5.2dB 5.1dB 5.0dB 5.7dB 4.3dB 4.2dB No.3 4.6dB 5.0dB 5.1dB 5.0dB 5.7dB 4.5dB 4.2dB No.4 4.8dB 5.2dB 5.0dB 5.0dB 5.7dB 5.2dB 4.2dB *3m/1m/0.5m = Measurement distance Radiated emission test(3m) The data listed in this report meets the limits unless the uncertainty is taken into consideration. Test report No. : 10017512H-A Page : 6 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 3.5 Test Location UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. code: 200…
Text truncated - open the document above for the full version.
Test report No. : 10017512H-A Page : 14 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Radiated Emission (Below 1GHz) Photo 1 Photo 2 Test report No. : 10017512H-A Page : 15 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Radiated Emission (Below 1GHz) Photo 1 Photo 2 Test report No. : 10017512H-A Page : 16 of 16 Issued date : June 24, 2013 FCC ID : CWTWD1U848 UL Japan, Inc. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst Case Position (Horizontal: X-axis/ Vertical:Y-axis) X-axis Y-axis Z-axis End of Report
4383-326 Asama-cho, Ise-shi · Mie-ken · Japan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 315 MHz - 315 MHz | - |
5G Communication Module
Equipment Class
PCB - PCS Licensed TransmitterAutomatic access gesture control
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Sensor for opening and closing doors in cars
Equipment Class
FDS - Part 15 Field Disturbance Sensor
Automatic access gesture control
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
KEYLESS ENTRY SYSTEM
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter