Hardware Requirement Specification (HRS) Orion Energy Management Doc.No: 61 8003 011 Valid from Revision P5 Approved by: Date: Orion Energy Management 61 8003 011 HARDWARE REQUIREMENT SPECIFICATION HRS Hardware Requirement Specification (HRS) Orion Energy Management Doc.No: 61 8003 011 Valid from Revision P7 Author(s): Jan Elfstrom Page 2/25 CONFIDENTIAL ©TIMELOX AB TABLE OF CONTENTS TABLE OF CONTENTS................................................................................................................. 2 1 DOCUMENT HISTORY .......................................................................................................... 4 2 INTRODUCTION ..................................................................................................................... 5 2.1 PROJECT NAME.................................................................................................................... 5 2.2 PROJECT NUMBER................................................................................................................ 5 3 REFERENCES .......................................................................................................................... 5 4 DEFINITIONS........................................................................................................................... 5 5 GENERAL REQUIREMENTS ............................................................................................... 5 5.1 USER INTERFACE................................................................................................................. 5 5.1.1 Introduction ..................................................................................................................... 5 5.1.2 Housing............................................................................................................................ 6 5.1.3 Display............................................................................................................................. 7 5.1.4 User Controls ..................................................................................................................7 5.1.5 Electrical interface levels ................................................................................................ 8 5.1.6 Module Communications Interface ................................................................................. 8 5.1.7 Service Interface ..............................................................................................................8 5.1.8 Power supply ...................................................................................................................9 5.1.9 Temperature sensor ......................................................................................................... 9 5.1.10 Firmware ................................................................................................................... 10 5.2 THERMOSTAT CONTROLLER.............................................................................................. 10 5.2.1 Introduction ...................................................................................................................10 5.2.2 Housing.......................................................................................................................... 11 5.2.3 Electrical interfaces....................................................................................................... 11 5.2.4 I/O Connector ................................................................................................................ 11 5.2.5 Module Communications Interface ............................................................................... 12 5.2.6 Power supply ................................................................................................................. 14 5.2.7 Firmware .......................................................................................................................14 5.2.8 Parameters - CT The following parameters in NV memory is to control the TC. These values are to be filled in by AAH and used by Computime. ...................................................... 14 5.2.9 Parameters - AAH ......................................................................................................... 16 5.2.10 Audit Trail ................................................................................................................. 16 5.2.11 HVAC Control Chart – Standard Control ................................................................. 16 5.2.12 Real Time Clock (RTC) ............................................................................................. 17 5.2.13 Counters .................................................................................................................... 17 5.3 MOTION DETECTOR........................................................................................................... 18 5.3.1 Introduction ...................................................................................................................18 5.3.2 Housing.......................................................................................................................... 19 5.3.3 PIR Detector .................................................................................................................. 19 5.4 RF DEVICE......................................................................................................................... 21 5.4.1 RF Device for User Interface (Phase 2) ........................................................................ 21 5.4.2 RF Device for Motion Detector ..................................................................................... 21 5.4.3 RF Device for Thermostat Controller ........................................................................... 21 Hardware Requirement Specification (HRS) Orion Energy Management Doc.No: 61 8003 011 Valid from Revision P7 …
Text truncated - open the document above for the full version.
SCS-F18: Project and Product Certification Representative Authorization Letter Page 1 of 2 Rev 2.0 2206 Ringwood Avenue San Jose, CA 95131 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Project and Product Certification Representative Authorization Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 Revised wording (current) 1.0 2.0 Sept–25-2007 SCS-F18: Project and Product Certification Representative Authorization Letter Page 2 of 2 Rev 2.0 Computime Limited 2010-08-18 To: SIEMIC, INC. 2206 Ringwood Avenue, San Jose, CA 95131 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We, __ Computime Limited _ hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Motion Sensor (AAHMS01) We affirm that between SIEMIC and __ Computime Limited ___, any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Client’s Client’s name / title: Contact information / address 17/F, Great Eagle Centre, 23 Harbour Road, Wanchai, Hong Kong
SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 Confidentiality Request Letter Revision History Reason for Amendment (current / obsolete) From To Approved Date Initial Release (current) 1.0 1.0 Nov-14-2006 SCS-F19: Confidentiality Request Letter Rev 1.0 Nov 14, 2006 Computime Limited 2010-08-18 To: Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: DI2AAHMS01 We hereby request confidential treatment of information accompanying this application as outlined below: - Schematics - Block Diagram - Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Client’s Client’s name / title: Contact information / address: 17/F, Great Eagle Centre, 23 Harbour Road, Wanchai, Hong Kong
Label location
EUT RF Exposure The Max Conducted Peak Output Power is -8.21dBm(0.151mW) in highest channel (2.480GHz); The best case gain of the antenna is 2dBi. 2dBi logarithmic terms convert to numeric result is nearly 1.58 According to the formula. calculate the EIRP test result: EIRP= P x G = 0.151mW x 1.58 = 0.239mW ① SAR requirement: S= 60 / f(GHz) = 60/2.480 = 24.19 mW ②; ① < ②. So the SAR report is not required.
Global United Technology Service Co., Ltd. Report No: GTSE10080014802 Authorized Signature: Robinson Lo Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the GTS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of GTS International Electrical Approvals or testing done by GTS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by GTS International Electrical Approvals in writing. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.” 1 Cover Page FCC REPORT Applicant: Computime Limited Address of Applicant: 17/F, Great Eagle Centre, 23 Harbour Road, Wanchai, Hong Kong Equipment Under Test (EUT) Name: Motion Sensor Model No.: AAHMS01 FCC ID: DI2AAHMS01 Standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247: 2008 Date of Receipt: 12 Aug., 2010 Date of Test: 13-17 Aug., 2010 Date of Issue: 18 Aug., 2010 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No: GTSE10080014802 Global United Technology Service Co., Ltd. Project No.: GTSE100800148RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 34 2 Contents Page 1 COVER PAGE..................................................................................................................................................... 1 2 CONTENTS.......................................................................................................................................................... 2 3 TEST SUMMARY................................................................................................................................................ 3 4 GENERAL INFORMATION...............................................................................................................................4 4.1 CLIENT INFORMATION................................................................................................................................... 4 4.2 GENERAL DESCRIPTION OF E.U.T............................................................................................................... 4 4.3 TEST ENVIRONMENT AND MODE.................................................................................................................... 5 4.4 TEST FACILITY............................................................................................................................................... 5 4.5 TEST LOCATION............................................................................................................................................ 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER.............................................................................. 5 4.7 TEST INSTRUMENTS LIST.............................................................................................................................. 6 5 TEST RESULTS AND MEASUREMENT DATA............................................................................................ 7 5.1 ANTENNA REQUIREMENT:............................................................................................................................. 7 5.2 CONDUCTED EMISSIONS...............................................................................................................................8 5.3 CONDUCTED PEAK OUTPUT POWER.......................................................................................................... 11 5.4 6DB OCCUPY BANDWIDTH.......................................................................................................................... 14 5.5 POWER SPECTRAL DENSITY....................................................................................................................... 17 5.6 BAND EDGE................................................................................................................................................. 20 5.7 RF ANTENNA CONDUCTED SPURIOUS EMISSIONS..................................................................................... 22 5.8 RADIATED EMISSION................................................................................................................................... 29 5.8.1 Radiated emission below 1GHz.............................................................................................................. 31 5.8.2 Transmitter emission above 1GHz ......................................................................................................... 32 Report No: GTSE10080014802 Global United Technology Service Co., Ltd. Project No.: GTSE100800148RF 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 34 3 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203/15.247 (c) Passed AC Power Line Conducted Emission 15.207 Passed Conducted Peak Output Power 15.247 (b)(3) Passed 6dB Occupied Bandwidth 15.…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 151.00 µW |

Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Receiver
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Thermostat Controller
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Thermostat
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
US SMART PLUG
Equipment Class
DTS - Digital Transmission System