DI2RCMHLManual Transmitter for Hi/Lo Type Fireplace

Computime Limited
Manual Transmitter for Hi/Lo Type Fireplace - FCC ID DI2RCMHL - Computime Limited
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Jul 17, 2002
Application Purpose
Original Equipment
Date of Application
Jul 17, 2002
Equipment Note
Manual Transmitter for Hi/Lo Type Fireplace
Frequency Range
350.00000000 - 350.00000000
Company
Computime Limited
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Operational Description

โ†—

Schematics

โ†—

Test Report

โ†—
โ†—
โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Block Diagram

3XAAA BATTERY VOLTAGE REGULATOR CIRCUIT LOW BATTERY CIRCUIT LCD MCU Temperature SENSOR 350MHz sine wave oscillation CIRCUIT 20 bit address generationRF control signal key input

External Photos

Test SetupFCCID : DI2RCMHL External Photo -front External Photo - rear

ID Label/Location Info

FCC ID : DI2RCMHL IC : 1700A-RCMHL This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undersired operation. Model : RCMHL MADE IN CHINA

Internal Photos

Test SetupFCCID : DI2RCMHL Internal Photo - 1 Internal Photo - 2 Test SetupFCCID : DI2RCMHL Internal Photo โ€“ 3 Internal Photo - 4

Operational Description

Critical Component of MHN2MH(TX) ComponentPart Number Description MCU MSM64P164U2Control all activities of the unit, detect and display temperature, PT2240U3Generate 20 bit address and encode the RF signal 103ATTH1Detect the temperature RF transistor MMBTH10Q1Generate oscillation of RF frequency 350MHz and as modulator

Schematics

-1 - Wed Jun 12 20:11:04 2002

Test Report

โ€ข The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. โ€ข This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. โ€ข For Terms And Conditions of the services, it can be provided upon request. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Computime Limited Application For Certification (FCC ID: DI2RCMHL) Transmitter WO# 0207989 WL/Sandy July 8, 2002 INTERTEK TESTING SERVICES FCC ID: DI2RCMHL i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: DI2RCMHL ii MEASUREMENT/TECHNICAL REPORT Computime Limited - MODEL: Ambient RCMHL FCC ID: DI2RCMHL July 8, 2002 This report concerns (check one:)Original Grant X Class II Change Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [12-18-01 Edition] provision. Report prepared by:Wilson Loke Intertek Testing Services 2/F., Garment Center, 576, Castle Peak Road, HONG KONG Phone:852-2173-8575 Fax:852-2371-0521 INTERTEK TESTING SERVICES FCC ID: DI2RCMHL iii Table of Contents 1.0 General Description..................................................................................................................2 1.1 Product Description..............................................................................................................2 1.2 Related Submittal(s) Grants....................................................................................................2 1.3 Test Methodology.................................................................................................................3 1.4 Test Facility.........................................................................................................................3 2.0 System Test Configuration..........................................................................................................5 2.1 Justification..........................................................................................................................5 2.2 EUT Exercising Software.......................................................................................................5 2.3 Special Accessories...............................................................................................................5 2.4 Equipment Modification.........................................................................................................6 2.5 Measurement Uncertainty......................................................................................................6 2.6 Support Equipment List and Description..................................................................................6 3.0 Emission Results.......................................................................................................................8 3.1 Field Strength Calculation.......................................................................................................9 3.2 Radiated Emission Configuration Photograph..........................................................................11 3.3 Radiated Emission Data........................................................................................................12 4.0 Equipment Photographs............................................................................................................15 5.0 Product Labelling....................................................................................................................17 6.0 Technical Specifications...........................................................................................................19 7.0 Instruction Manual..................................................................................................................21 8.0 Miscellaneous Information........................................................................................................23 8.1 Measured Bandwidth...........................................................................................................24 8.2 Discussion of Pulse Desensitization.......................................................................................25 8.3 Calculation of Average Factor...............................................................................................26 8.4 Emissions Test Procedures..................................................................................................27 INTERTEK TESTING SERVICES FCC ID: DI2RCMHL iv List of attached file Exhibit typeFile Descriptionfilename Test ReportTest Reportreport.pdf Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated photos.doc Test ReportBandwidth Plotbw.pdf External PhotoExternal Photoexternal photos.doc Internal PhotoInternal Photointernal photos.doc Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.pdf ID Label/LocationLabel Artwork and Locationlabel.pdf User ManualUser Manualmanual.pdf Timing DiagramTiming Diagramtiming.pdf INTERTEK TESTING SERVICES FCC ID: DI2RCMHL 1 EXHIBIT 1 GENERAL DESCRIPTION INTERTEK TESTING SERVICES FCC ID: DI2RCMHL 2 1.0General Description 1.1Product Description The Eqโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Test SetupFCCID : DI2RCMHL Radiated -front Radiated - rear

Contact Information

Applicant

Philip Chung(Reliability Manager)
[email protected]852 2660 0464Fax: 852 2790-3996

Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilson Loke
[email protected]852 2173 8575

2/F, Garment Centre ยท Kowloon ยท Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Wilson Loke
[email protected]852 2173 8575

Test Firm

Intertek Testing Services Hong KongBilly Chow
[email protected]852-2173-8528Fax: 852-2371-0914

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)350 MHz - 350 MHz-

Other Applications from Computime Limited

Transmitter - FCC ID DI2RCSTA-TX - Computime Limited
DI2RCSTA-TX

Transmitter

Dec 04, 2014

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Receiver - FCC ID DI2RCST-RX - Computime Limited
DI2RCST-RX

Receiver

Dec 04, 2014

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Thermostat Controller - FCC ID DI2AAHZT3A - Computime Limited
DI2AAHZT3A

Wireless Thermostat Controller

May 29, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Thermostat - FCC ID DI2AAHZT21 - Computime Limited
DI2AAHZT21

Wireless Thermostat

May 27, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
US SMART PLUG - FCC ID DI2-TDL6192 - Computime Limited
DI2-TDL6192

US SMART PLUG

Oct 07, 2012

Equipment Class

DTS - Digital Transmission System