
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
28.04.2010 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Subject: User ́s Manual for WRTZ-1000 RDR US, Front Store Back Store System US Dear Sir/Madam, Checkpoint Systems, Inc., the manufacturer of models WRTZ-1000 RDR US, Front Store Back Store System US, under FCC ID: DO4WRTZ1000, does not provide an installation manual to the customer since the system is professionally installed by trained Checkpoint personnel or designated Representatives. Customers are trained on general system use and operation at the time of system installation. Sincerely, Mr. Thomas Ring Manager Certification mikes-testingpartners gmbh Ohmstrasse 2-4 94342 Strasskirchen Germany Phone: 0049 9424 9481 0 Fax: 0049 9424 9481 240
iii Important Information to our Users in North America FCC Regulatory Compliance Statement Checkpoint Systems, Inc., offers Electronic Article Surveillance equipment that have been FCC certified or verified to 47 CFR Part 15 Subparts B/C and/or 47 CFR Part 18. Appropriately, one of the following labels will apply to the approval: NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. - OR - This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) including this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation, which may include intermittent decreases in detection and/or intermittent increases in alarm activity. - OR - NOTE: This equipment has been tested and found to comply with the limits for a miscellaneous type ISM device, pursuant to Part 18 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio communications reception, which can be determined by turning the equipment off and on, please contact Checkpoint Systems, Inc., at 1 (800) 257-5540 for further assistance. Equipment Safety Compliance Statement Checkpoint Systems Electronic Article Surveillance equipment has been designed to be safe during normal use and, where applicable, certain components of the system or accessory sub-assemblies have been certified, listed or recognized in accordance with one or more of the following Safety standards: UL 60950-1, CSA C22.2 No. 60950-1. Additional approvals may be pending. WARNING: Changes or modifications to Checkpoint’s Electronic Article Surveillance equipment not expressly approved by the party responsible for assuring compliance could void the user’s authority to operate the equipment in a safe or otherwise regulatory compliant manner.
05.05.2010 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Re: Change of documentation Dear Sirs, because of the following described reasons, we have issued new documents. Please be so kind to upload these at the FCC page. (FCC ID: DO4WRTZ1000) - change of type designation of the power supply in the test report - modification of the test report because of some spelling mistakes - adding of some words (example: “Refer to section 5.5.5.1 for test data”) page 37 Sincerely, Mr. Thomas Ring Manager Certification mikes-testingpartners gmbh Ohmstrasse 2-4 94342 Strasskirchen Germany Phone: 0049 9424 9481 0 Fax: 0049 9424 9481 240
ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Photo documentation of the EUT Model: WRTZ - 1000 and Antenna Type No. 520 10073 External Views: - Test Setup: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 External Views – Reader: Front: Top: Rear: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Bottom: Side view left: Side view right: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Antenna Typ (5.2 dBi): Front view: Rear view: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Side view right: Side view left: Top view: Bottom view: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Label and antenna connector: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Power supply units and Converter: EOS – Red Rocket – LFZVC60NP12E4 XP Power Supply – AEB70US24117
ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Bottom: Side view left: Side view right:
ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Internal Views: Open housing bottom view: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Open housing bottom detail view: ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 ATTACHMENT A to File No.: T34121-01 mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Open housing bottom view:
ATTACHMENT B to File No.: T34121-01-00HU mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 Maximum permissible exposure (MPE) Model: WRTZ - 1000 and Antenna Type No. 520 10073 1.1 For test instruments and accessories used see section 6 Part CPC 2. 1.1.1 Description of the test location Test location: AREA4 1.1.2 Applicable standard According to FCC Part 15, Section 15.247(i): Systems operating under the provisions of this section shall be operated in a manner that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. The test methods used comply with ANSI/IEEE C95.1, “IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz”. This test report shows the compliance with the limits for Maximum Permissible Exposure (MPE) specified in FCC Part 1, Section 1.1310 and the criteria to evaluate the environmental impact of human exposure to radio- frequency (RF) radiation as specified in FCC Part 1, Section 1.1307(b). 1.1.3 Description of Measurement The maximum total power input to the antenna has been measured conducted as described in clause 5.3 of this document. Through the Friis transmission formula, the known maximum gain of the antenna and the maximum power, the MPE can be calculated in a defined distance away from the product. Friis transmission formula: P d = 2 **4 * r GP out Π where P d =power density (mW/cm 2 ) P out = output power to antenna (mW) G = gain of antenna (linear scale) r = distance between antenna and observation point (cm) ATTACHMENT B to File No.: T34121-01-00HU mikes-testingpartners gmbh Ohmstrasse 2-4 D-94342 Strasskirchen Tel:+49-9424-9481-0 Fax:+49-9424-9481-240 Rev. No 1.0 1.1.4 Test result Power setting 30 dBm Antenna gain 8.2 dBic (5.2 dBi) Channel No. Frequency Max power output to antenna Antenna gain Cable loss Power density Limit of power density (MHz) (dBm) (mW) (dBi) (dB) (mW/cm 2 ) (mW/cm 2 ) 1 902.75 28.3 676.1 5.2 1.0 0.354 0.602 25 914.75 28.0 631.0 5.2 1.0 0.330 0.610 50 927.25 27.4 549.5 5.2 1.0 0.288 0.618 Limits for maximum permissible exposure (MPE): Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Averaging Time (minutes) (B) Limits for General Population / Uncontrolled Exposure 0.3 – 3.0 614 1.63 100 30 3.0 – 30 824/f 2.19/f 180/ f 2 30 30 - 300 27.5 0.073 0.2 30 300-1500 --- --- f/1500 30 1500-100000 --- --- 1.0 30 f = Frequency (MHz) According to FCC Rules 47CFR 2.1093(b) the EUT is not a portable device. The EUT is designed to be used that radiating structures are more than 20 cm outside of the body of the user. (r = 20 cm). Note: The manufacturer shall state in the manual the minimum cable length for each antenna. Aditionally this shall be stated on the label of the EuT. The requirements are FULFILLED. Remarks:
FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 1 of 54 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 EMI -- T E S T R E P O R T - FCC Part 15.247 FHSS- Test Report No. : T34121-01-00HU 03. May 2010 ______________________________________________________________________________________________ Date of issue Type / Model Name : WRTZ - 1000 Product Description : RFID UHF Reader Applicant : Checkpoint Systems, Inc. Address : 101 Wolf Drive, Thorofare New Jersey, USA 08086 Manufacturer : Checkpoint Systems, Inc. Address : 101 Wolf Drive, Thorofare New Jersey, USA 08086 Licence holder : Checkpoint Systems, Inc. Address : 101 Wolf Drive, Thorofare New Jersey, USA 08086 Test Result according to the standards listed in clause 1 test standards: POSITIVE The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test results without the written permission of the test laboratory. DAT-P-207/05-00 Registration No. DAT-P-207/05 FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 2 of 54 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 Contents 1 TEST STANDARDS 3 2 SUMMARY 4 3 EQUIPMENT UNDER TEST 5 3.1 Photo documentation of the EUT – Detailed photos see Attachment A 5 3.2 Test setup 5 3.3 Power supply system utilised 5 3.4 Short description of the EUT 5 4 TEST ENVIRONMENT 7 4.1 Address of the test laboratory 7 4.2 Environmental conditions 7 4.3 Statement of the measurement uncertainty 7 4.4 Measurement Protocol for FCC, VCCI and AUSTEL 8 5 TEST CONDITIONS AND RESULTS 9 5.1 Conducted emissions 9 5.2 20 dB bandwidth 19 5.3 Maximum peak conducted output power 24 5.4 Spurious RF conducted emissions 26 5.5 Spurious radiated emissions 32 5.6 Hopping sequence 39 5.7 Equal hopping frequency use 39 5.8 Receiver input bandwidth 39 5.9 Dwell time 40 5.10 Channel separation 43 5.11 Quantity of hopping channels 46 5.12 Antenna application - Detailed photos see Attachment A 49 5.13 Maximum permissible exposure (MPE) – See Attachment B 50 6 USED TEST EQUIPMENT AND ACCESSORIES 51 7 Constructional dataform for testing 52 FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 3 of 54 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 1 TEST STANDARDS The tests were performed according to following standards: FCC Rules and Regulations Part 15, Subpart A - General (October, 2009) Part 15, Subpart A, Section 15.31 Measurement standards Part 15, Subpart A, Section 15.33 Frequency range of radiated measurements Part 15, Subpart A, Section 15.35 Measurement detector functions and bandwidths FCC Rules and Regulations Part 15, Subpart B - Unintentional Radiators (October, 2009) Part 15, Subpart B, Section 15.107 AC Line conducted emissions, Part 15, Subpart B, Section 15.109 Radiated emissions, general requirements FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (October, 2009) Part 15, Subpart C, Section 15.203 Antenna requirement Part 15, Subpart C, Section 15.204 External radio frequency power amplifiers and antenna modifications Part 15, Subpart C, Section 15.205 Restricted bands of operation Part 15, Subpart C, Section 15.207 Conducted limits Part 15, Subpart C, Section 15.209 Radiated emission limits, general requirements Part 15, Subpart C, Section 15.247 Operation within the bands 902 - 928 MHz, 2400 - 2483.5 MHz and 5725 - 5850 MHz FCC Rules and Regulations Part 1, Subpart I - Procedures Implementing the National Environmental Policy Act of 1969 Part 1, Subpart I, Section 1.1310 Radiofrequency radiation exposure limits Part 1, Subpart 2, Section 2.1093 Radiofrequency radiation exposure evaluation: portable device OET Bulletin 65, 65A, 65B, 65C Edition 97-01, August 1997 – Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. ANSI C63.4: 2003 Methods of Measurement of Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. ANSI C95.1:1992 IEEE Standard for Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz CISPR 16-4-2: 2003 Uncertainty in EMC measurement CISPR 22: 2005 Information technology equipment EN 55022: 2006 FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 4 of 54 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 2 SUMMARY GENERAL REMARKS: The frequency range was scanned from 9 kHz to 10 GHz. All emissions not reported in this test report were more than 10 dB below the specified limit. The EuT is a frequency hopping system using 50 channels in the frequency band from 902 to 928 MHz. The antenna UHF RFID Antenna (8.2 dBic) are provided with the EuT: • UHF RFID antenna: Type 520 10073 (8.2 dBic) Measurements have been made with power settings of 30.0 dBm. The EuT is declared as Class A digital device. The EuT fulfills the requirements of a class B device. It is not possible to set the EuT only in receiving mode. FINAL ASSESSMENT: The equipment under test fulfills the EMI requirements cited in clause 1 test standards. Date of receipt of test sample : acc. to storage records Testing commenced on : 17. March 2010 Testing concluded on : 25. March 2010 Checked by: Tested by: Thomas Weise Dipl.-Ing.(FH) Laboratory Manager Markus Huber FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 5 of 54 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EUT – Detailed photos see Attachment A 3.2 Test setup 3.3 Power supply system utilised Power supply voltage: : 100-240 V / 50-60 Hz / 1φ, 12 V DC 3.4 Short description of the EUT The EuT WRTZ - 1…
Text truncated - open the document above for the full version.
FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 5 of 51 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 3 EQUIPMENT UNDER TEST 3.1 Photo documentation of the EUT – Detailed photos see Attachment A 3.2 Test setup 3.3 Power supply system utilised Power supply voltage: : 100-240 V / 50-60 Hz / 1φ, 12 V DC 3.4 Short description of the EUT The EuT WRTZ - 1000 is a UHF RFID reader. It can read active and passive Tags in the frequency range from 902 to 928 MHz. 8 antenna connectors are available. Number of tested samples: 1 Serial number: Prototype EUT operation mode: The equipment under test was operated during the measurement under the following conditions: - TAG reading mode supplying 30.0 dBm - Standby mode - FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 9 of 51 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 5 TEST CONDITIONS AND RESULTS 5.1 Conducted emissions For test instruments and accessories used see section 6 Part A 4. 5.1.1 Description of the test location Test location: Shielded Room S2 5.1.2 Photo documentation of the test set-up FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 19 of 51 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 5.2 20 dB bandwidth For test instruments and accessories used see section 6 Part MB. 5.2.1 Description of the test location Test location: AREA4 5.2.2 Photo documentation of the test set-up 5.2.1 Applicable standard According to FCC Part 15C, Section 15.247(a): Frequency hopping systems shall have hopping carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel, whichever is greater. 5.2.2 Description of Measurement The bandwidth is measured at an amplitude level reduced from the reference level by a specified ratio of -20 dB. The reference level is the level of the highest amplitude signal observed from the transmitter at either the fundamental frequency or the first-order modulation products in all typical modes of operation, including the unmodulated carrier, even if atypical. FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 24 of 51 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 5.3 Maximum peak conducted output power For test instruments and accessories used see section 6 Part CPC 2. 5.3.1 Description of the test location Test location: AREA4 5.3.2 Photo documentation of the test set-up 5.3.3 Applicable standard According to FCC Part 15C, Section 15.247(b)(2): For frequency hopping systems operating in the 902-928 MHz band the maximum peak conducted output power shall not exceed the limit of 1 watt for systems employing at least 50 hopping channels. The conducted output power limit specified in paragraph (b) of this section is based on the use of antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output power from the intentional radiator shall be reduced below the stated values in paragraphs (b)(1), (b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the antenna exceeds 6 dBi. 5.3.4 Description of Measurement A spectrum analyzer is connected to the output of the transmitter via a suitable attenuator while EUT was operating in transmit mode using the assigned frequency. Analyzer settings: Trace: Max. hold Detector: Max. peak RBW: greater than 20 dB bandwidth VBW: ≥ RBW Sweep Time: Coupled FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 26 of 51 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 5.4 Spurious RF conducted emissions For test instruments and accessories used see section 6 Part SEC1, SEC2 and SEC3. 5.4.1 Description of the test location Test location: AREA4 5.4.2 Photo documentation of the test set-up 5.4.3 Applicable standard According to FCC Part 15C, Section 15.247(d): In any 100 kHz bandwidth outside the frequency band 902 to 928 MHz, the digitally modulated radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or an radiated measurement. Attenuation below the general limits specified in Section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also comply with the radiated emission limit specified in Section 15.209(a). 5.4.4 Description of Measurement A spectrum analyzer is connected to the output of the transmitter via a suitable attenuator while EUT was operating in transmit mode at the assigned frequency. Spectrum analyzer settings: RBW 100 kHz VBW 300 kHz Detector Max. peak Trace: Max. hold Sweep time auto FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 32 of 51 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 5.5 Spurious radiated emissions For test instruments and accessories used see section 6 Part SER 1, SER 2, SER 3. 5.5.1 Description of the test location Test location: OATS1 Test distance: 3 metres Test location: Anechoic Chamber A2 Test distance: 3 metres 5.5.2 Photo documentation of the test set-up Open area test site FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 33 of 51 Ohmstrasse 2-4 x 94342 Strasskirchen Tel.:+49(0)9424-94810 x Fax:+49(0)9424-9481240 Rev. No. 1.1, 21.6.2008 Anechoic chamber FCC ID: DO4WRTZ1000 mikes-testingpartners gmbh File No. T34121-01-00HU, page 39 of 51 Oh…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.75 MHz - 927.25 MHz | 676.00 mW |
EAS RF System
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterUHF-RFID Reader WRTZ-1550
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterEAS RF Detection System
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterEAS RFDetection System
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterAntenna Pedestal
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter