FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Evenflo Company, Inc./
  3. EHKEVENFLOTS624R

EHKEVENFLOTS624RBaby Monitor 900MHz (Parent Unit)

Evenflo Company, Inc.
Baby Monitor 900MHz (Parent Unit) - FCC ID EHKEVENFLOTS624R - Evenflo Company, Inc.
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Mar 20, 2003
Application Purpose
Original Equipment
Date of Application
Mar 20, 2003
Equipment Note
Baby Monitor 900MHz (Parent Unit)
Frequency Range
905.80000000 - 906.40000000
Company
Evenflo Company, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Block Diagram

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Operational Description

β†—

Schematics

β†—

Test Report

β†—
β†—

Test Setup Photos

β†—
β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

Test Setup FCC ID : EHKEVENFLOTS624R External Photo -front External Photo - rear

Internal Photos

Test Setup FCC ID : EHKEVENFLOTS624R Internal Photo - 1 Internal Photo - 2 Test Setup FCC ID : EHKEVENFLOTS624R Internal Photo - 3 Internal Photo - 4

Test Report

β€’ The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. β€’ This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited. β€’ For Terms And Conditions of the services, it can be provided upon request. β€’The evaluation data of the report will be kept for 3 years from the date of issuance. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2371 0521 Evenflo Company, Inc. Application For Certification (FCC ID: EHKEVENFLOTS624R) Superheterodyne Receiver WO# 0217063 DL/Sandy February 26, 2003 INTERTEK TESTING SERVICES FCC ID: EHKEVENFLOTS624R i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1:General Description EXHIBIT 2:System Test Configuration EXHIBIT 3:Emission Results EXHIBIT 4:Equipment Photographs EXHIBIT 5:Product Labelling EXHIBIT 6:Technical Specifications EXHIBIT 7:Instruction Manual EXHIBIT 8:Miscellaneous Information INTERTEK TESTING SERVICES FCC ID: EHKEVENFLOTS624R ii MEASUREMENT/TECHNICAL REPORT Evenflo Company, Inc. MODEL: Constant Care 4000 Parent Pager Monitor 624000 FCC ID: EHKEVENFLOTS624R This report concerns (check one:)Original Grant X Class II Change ____ Equipment Type: Superheterodyne Receiver (example: computer, printer, modem, etc.) Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37?Yes No X If no, assumed Part 15, Subpart B for unintentional radiator - the new 47 CFR [12-18-01 Edition] provision. Report prepared by:Derek Leung Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576, Castle Peak Road, Kowloon, Hong Kong. Phone:852-2173-8504 Fax:852-2371-0521 INTERTEK TESTING SERVICES FCC ID: EHKEVENFLOTS624R iii Table of Contents 1.0 General Description............................................................................................................2 1.1 Product Description............................................................................................................2 1.2 Related Submittal(s) Grants.................................................................................................2 1.3 Test Methodology...............................................................................................................3 1.4 Test Facility........................................................................................................................3 2.0 System Test Configuration.................................................................................................5 2.1 Justification.........................................................................................................................5 2.2 EUT Exercising Software....................................................................................................5 2.3 Special Accessories............................................................................................................5 2.4 Equipment Modification......................................................................................................6 2.5 Measurement Uncertainty....................................................................................................6 2.6 Support Equipment List and Description..............................................................................6 3.0 Emission Results.................................................................................................................8 3.1 Field Strength Calculation....................................................................................................9 3.2 Radiated Emission Configuration Photograph.....................................................................10 3.3 Radiated Emission Data....................................................................................................11 3.4 Conducted Emission Configuration Photograph..................................................................13 3.5 Conducted Emission Data.................................................................................................14 4.0 Equipment Photographs....................................................................................................16 5.0 Product Labelling..............................................................................................................18 6.0 Technical Specifications....................................................................................................20 7.0 Instruction Manual............................................................................................................22 8.0 Miscellaneous Information...............................................................................................24 8.1 Discussion of Pulse Desensitization....................................................................................25 8.2 Calculation of Average Factor...........................................................................................26 8.3 Emissions Test Procedures................................................................................................27 INTERTEK TESTING SERVICES FCC ID: EHKEVENFLOTS624R iv List of attached file Exhibit typeFile Descriptionfilename Test ReportTest Reportreport.pdf Operation DescriptionTechnical Descriptiondescri.pdf Test Setup PhotoRadiated Emissionradiated photos.pdf Test Setup PhotoConducted Emissionconducted photos.pdf Test ReportConducted Emission Test Resultconducted.pdf External PhotoExternal Photoexternal photos.pdf Internal PhotoInternal Photointernal photos.pdf Block DiagramBlock Diagramblock.pdf SchematicsCircuit Diagramcircuit.…

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup FCC ID : EHKEVENFLOTS624R Radiated -front Radiated - rear

Test Setup Photos

Test Setup FCC ID : EHKEVENFLOTS624R Conduct Photo - 1 Conduct Photo - 2 Test Setup FCC ID : EHKEVENFLOTS624R Conduct Photo – 3

Contact Information

Applicant

Thomas A Sparno(Executive Vice President, Gen Counsel & Secy.)
[email protected]937-415-3300Fax: 937-415-3127

Technical Contact

Intertek Testing Services Hong Kong Ltd.Derek Leung
[email protected]852-2173-8504

2/F., Garment Centre, Β· Kowloon, Β· Hong Kong

Non-Technical Contact

Intertek Testing Services Hong Kong Ltd.Derek Leung
[email protected]852-2173-8504

Test Firm

Intertek Testing Services Hong KongC. Yuen
[email protected]852-2173-8565Fax: 852-2742-5716

Technical Specifications

#Rule PartsFrequency RangePower Output
115B905.8 MHz - 906.4 MHz-

Other Applications from Evenflo Company, Inc.

Remote Control Door Gate - FCC ID EHK315463GMMPGATE - Evenflo Company, Inc.
EHK315463GMMPGATE

Remote Control Door Gate

Feb 04, 2006

Equipment Class

CRR - Superregenerative Receiver
Wall Mounted Remote Control - FCC ID EHK315463WMHFGATE - Evenflo Company, Inc.
EHK315463WMHFGATE

Wall Mounted Remote Control

Feb 04, 2006

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control Door gate - FCC ID EHK315463GMOPGATE - Evenflo Company, Inc.
EHK315463GMOPGATE

Remote Control Door gate

Feb 04, 2006

Equipment Class

CRR - Superregenerative Receiver
Removable Remote Control - FCC ID EHK315463RHFGATE - Evenflo Company, Inc.
EHK315463RHFGATE

Removable Remote Control

Feb 04, 2006

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
900MHz Transceiver - FCC ID EHK900646TTRIA - Evenflo Company, Inc.
EHK900646TTRIA

900MHz Transceiver

Jul 02, 2004

Equipment Class

DXT - Part 15 Low Power Transceiver, Rx Verified