Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 29, 2023
Application Purpose
Original Equipment
Date of Application
Oct 29, 2023
Equipment Note
Level Bridge
Frequency Range
2405.00000000 - 2475.00000000
Company
Primax Electronics Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗
↗
↗
↗

Test Setup Photos

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

LevelBridgeInstructions What'sintheBox? LevelBridge,Wallmountingadhesivetape Step1:PoweringuptheBridge PlugintheBridge ThelogoonthefrontoftheLevelBridgeisbacklitwithanRGBWLED.Oncepluggedin theLEDwillbegintoindicatestatus. TheBridgetakesupto2minutestotaltobootup.OncebootedtheBridgeLEDwillflash red. Step2:BridgeConfigurationandSpaceAssociation AssoonastheBridgeisbootedup,beginconfigurationintheLevelInstallerApp. EntertheBridgeSerialNumber ScantheQRcodeorentertheBridgeserialnumberintheLevelInstallerapptotrigger theautomatedprocessforBridgeconfigurationaswellastheassociationoftheBridge withtheselectedspace. ConfigurationErrors “Matchingbridgesetupdatanotfound.Pleasecheckyourentryorrebootyourbridge andwaitforittocomeonlineagain.” Iftheserialnumberwasenteredmanually,thiserrorcouldbeduetoatypo.Pleasekeep inmindthatBridgeserialnumbersaretendigitslongandcontainnumbersandletters. Theseshouldbeenteredexactlyasseenonthelabelincludingthecase-sensitiveletters. Sometimestheerrorcanbecausedbyanincompletebootupprocess.Ifyouencounter thiserror,waitapproximately2minutesandresubmittheserialnumberintheLevelapp. SpaceAssociationErrors WhenassociatingaBridgetoanewspacethesearethepossibleerrorsthatausermay encounter: “BridgeDoesNotExist” Thiserrortypicallyoccurswhentheuserhasenteredtheserialnumberincorrectly.When enteringtheserialnumbermanually,ensureexactnessincludingcase-sensitiveletters. “SpaceAlreadyHasabridge” Thiserroroccurswhenaspaceyou’reinstallingthebridgeintoalreadyhasabridge. BridgeTroubleshooting:PowerCycling/RebootingBridge OneofthemostbasictroubleshootingstepstotakewhenworkingwithaBridgeisto Reboot/powercyclethebridge. BridgeRebootviatheInstallerapp: AccessthebridgeviatheLevelInstallerapp. a.Fromthe“SpaceDetails”pageintheInstallerapp,selectthe“bridge”tab. 2.Onceinsidethe“bridge”tab,selectthethree-dotmenuintheupperrightcorner. 3.Selectingthe“Rebootbridge”option. Thisisnottobeconfusedwith“Restartbridge” BridgeRebootviaPowerCycle Unplugthebridge,wait10secondsandplugthebridgeinagaintoreboot. FederalCommunicationCommissionInterferenceStatement ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowing twoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevice mustacceptanyinterferencereceived,includinginterferencethatmaycauseundesired operation. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovide reasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.This equipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalled andusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnotoccurina particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor televisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,the userisencouragedtotrytocorrecttheinterferencebyoneofthefollowingmeasures: ● Reorientorrelocatethereceivingantenna. ● Increasetheseparationbetweentheequipmentandreceiver. ● Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe receiverisconnected. ● Consultthedealeroranexperiencedradio/TVtechnicianforhelp. FCCCaution:Anychangesormodificationsnotexpresslyapprovedbytheparty responsibleforcompliancecouldvoidtheuser'sauthoritytooperatethisequipment. Thistransmittermustnotbeco-locatedoroperatinginconjunctionwithanyother antennaortransmitter. RadiationExposureStatement: ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithminimumdistance 20cmbetweentheradiator&yourbody. IndustryCanadaStatement ThisdevicecomplieswithISED’slicense-exemptRSSs.Operationissubjecttothe followingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)this devicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesiredoperation. LeprésentappareilestconformeauxCNRd’ISEDapplicablesauxappareilsradio exemptsdelicence.L’exploitationestautoriséeauxdeuxconditionssuivantes:(1)le dispositifnedoitpasproduiredebrouillagepréjudiciable,et(2)cedispositifdoit acceptertoutbrouillagereçu,ycomprisunbrouillagesusceptibledeprovoquerun fonctionnementindésirable. RadiationExposureStatement: ThisequipmentcomplieswithISEDradiationexposurelimitssetforthforanuncontrolled environment.Thisequipmentshouldbeinstalledandoperatedwithgreaterthan20cm betweentheradiator&yourbody. Déclarationd'expositionauxradiations:Cetéquipementestconformeauxlimites d'expositionauxrayonnementsISEDétabliespourunenvironnementnoncontrôlé.Cet équipementdoitêtreinstalléetutiliséàplusde20cmentreleradiateuretvotrecorps. Certification FCCID:EMJOH1 IC:4251A-OH1 CANICES-003(B)/NMB-003(B)

Attestation Statements

No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: 2023-10-04 FCC ID:EMJOH1 To the attention of Federal Communications Commission Authorization and Evaluation Division Attestation Statements Attestation Statements Part 2.911(d)(5)(i) Filing PRIMAX ELECTRONICS LTD. certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Attestation Statements Part 2.911(d)(5)(ii) Filing PRIMAX ELECTRONICS LTD. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely yours, ------------------------------------------------------------------- Nelson Chou Compliance Dept. / Manager PRIMAX ELECTRONICS LTD. TEL: 886-2-2798-9008 ext. 1681 FAX:886-2-8797-1565 Email: [email protected]

Cover Letter(s)

No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 886-2-2798-9008 Fax: 886-2-8798-1565 Date: 2023/10/4 FCC ID:EMJOH1 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Block Diagram Schematics Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, ------------------------------------------------------------------- Nelson Chou Compliance Dept. / Manager PRIMAX ELECTRONICS LTD. TEL: 886-2-2798-9008 ext. 1681 FAX:886-2-8797-1565 Email: [email protected]

Cover Letter(s)

No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 886-2-2798-9008 Fax: 886-2-8798-1565 Date:2023/10/04 FCC ID: EMJOH1 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we request short-term confidential treatment for the following information until 2023/11/15 in order to ensure sensitive business information remains confidential until the actual marketing of the device: External photos Test Setup photos User’s manual Internal Photos Sincerely yours, ------------------------------------------------------------------- Nelson Chou Compliance Dept. / Manager PRIMAX ELECTRONICS LTD. TEL: 886-2-2798-9008 ext. 1681 FAX:886-2-8797-1565 Email: [email protected]

Cover Letter(s)

No. 669, Ruey Kuang Road Neihu Taipei, Taiwan, R.O.C. Tel: 883-2-2798-9008 Fax: 886-2-8798-1565 Date: 2023-10-04 FCC ID:EMJOH1 A U T H O R I Z A T I O N L E T T E R To whom it may concern: We, the undersigned, hereby authorize Andrea Hsia / Supervisor of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all manners relating to FCC application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Andrea Hsia / Supervisor of BV CPS Taoy uan on our behalf shall have the same effect as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours, ------------------------------------------------------------------- Nelson Chou Compliance Dept. / Manager PRIMAX ELECTRONICS LTD. TEL: 886-2-2798-9008 ext. 1681 FAX:886-2-8797-1565 Email: [email protected]

External Photos

Reference No.:BDKX-WTW-P23090577_ExtPho Page 1/3 CONSTRUCTION PHOTOS OF EUT Reference No.:BDKX-WTW-P23090577_ExtPho Page 2/3 Reference No.:BDKX-WTW-P23090577_ExtPho Page 3/3

Internal Photos

Reference No.:BDKX-WTW-P23090577_IntPho Page 1/6 CONSTRUCTION PHOTOS OF EUT Reference No.:BDKX-WTW-P23090577_IntPho Page 2/6 Reference No.:BDKX-WTW-P23090577_IntPho Page 3/6 Reference No.:BDKX-WTW-P23090577_IntPho Page 4/6 Reference No.:BDKX-WTW-P23090577_IntPho Page 5/6 Reference No.:BDKX-WTW-P23090577_IntPho Page 6/6

RF Exposure Info

Report No.: MFBDKX-WTW-P23090577 Page No. 1 / 8 Report Format Version: 7.1.0 Reference No.: BDKX-WTW-P23090577 RF EXPOSURE REPORT CERTIFICATE OF CONFORMITY FCC Rule Part: FCC Part 2 (Section 2.1091) Report No.: MFBDKX-WTW-P23090577 FCC ID: EMJOH1 Product: Level Bridge Brand: Level Model No.: H1 Received Date: 2023/9/25 Test Date: 2023/10/17 Issued Date: 2023/10/24 Applicant: PRIMAX ELECTRONICS LTD. Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 Approved by: , Date: 2023/10/24 Jeremy Lin / Project Engineer This test report consists of 8 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Annie Chang / Senior Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBDKX-WTW-P23090577 Page No. 2 / 8 Report Format Version: 7.1.0 Reference No.: BDKX-WTW-P23090577 Table of Contents Release Control Record ....................................................................................................................................................... 3 1 Certificate .................................................................................................................................................................... 4 2 Applicable RF Exposure Limit .................................................................................................................................. 5 3 Test Results ................................................................................................................................................................ 7 4 Conclusion .................................................................................................................................................................. 7 5 Information of the Testing Laboratories .................................................................................................................. 8 Report No.: MFBDKX-WTW-P23090577 Page No. 3 / 8 Report Format Version: 7.1.0 Reference No.: BDKX-WTW-P23090577 Release Control Record Issue No. Description Date Issued MFBDKX-WTW-P23090577 Original release. 2023/10/24 Report No.: MFBDKX-WTW-P23090577 Page No. 4 / 8 Report Format Version: 7.1.0 Reference No.: BDKX-WTW-P23090577 1 Certificate Product: Level Bridge Brand: Level Test Model: H1 Sample Status: Engineering sample Applicant: PRIMAX ELECTRONICS LTD. Test Date: 2023/10/17 FCC Rule Part: FCC Part 2 (Section 2.1091) Standard: KDB 447498 D04 Interim General RF Exposure Guidance v01 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Report No.: MFBDKX-WTW-P23090577 Page No. 5 / 8 Report Format Version: 7.1.0 Reference No.: BDKX-WTW-P23090577 2 Applicable RF Exposure Limit § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in § 1.1307(b) of this part within the frequency range of 100 kHz to 6 GHz (inclusive). (b) The SAR limits for occupational/controlled exposure are 0.4 W/kg, as averaged over the whole body, and a peak spatialaverage SAR of 8 W/kg, averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the parts of the human body treated as extremities, such as hands, wrists, feet, ankles, and pinnae, where the peak spatial-average SAR limit for occupational/controlled exposure is 20 W/kg, averaged over any 10 grams of tissue (defined as a tissue volume in the sha…

Text truncated - open the document above for the full version.

Test Report

This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: ORBDKX-WTW-P23090577 Page: 1 of 9 Report Format Version 3.0.2 3D Antenna Measurement Summary Report REPORT NO.: ORBDKX-WTW-P23090577 MODEL NAME: H1 TESTED D AT E: 2023.10.11 ISSUED: 2023.10.24 APPLICANT : PRIMAX ELECTRONICS LTD. ADDRESS : No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. ISSUED BY: Bureau Veritas Consumer Products Services (Hong Kong) Limited, Taoyuan Branch Mobile Communications Laboratory ADDRESS: No.19, Hwa Ya 2nd Rd., Kwei shan Dist., Taoyuan City, Taiwan (R.O.C) The client to claim product certification, approval, or endorsement by TAF, CTIA or any government agencies, should not use this report. Report No.: ORBDKX-WTW-P23090577 Page: 2 of 9 Report Format Version 3.0.2 RELEASE CONTROL RECORD REPORT NO. REASON FOR CHANGE DATE ISSUED ORBDKX-WTW-P23090577 Original release 2023.10.24 TABLE OF CONTENTS GENERAL INFORMATION ................................................................................................................................. 3 1. Test Methods ............................................................................................................................................... 4 2. Description of the anechoic chamber: ........................................................................................................ 4 3. Test Equipment List ..................................................................................................................................... 5 4. Measurement Uncertainty .......................................................................................................................... 5 5. Testing Setup Photo ................................................................................................................................... 5 6. Antenna Radiation Performance ................................................................................................................ 5 7. 3D Antenna Patterns .................................................................................................................................. 6 APPENDIX. EUT Photographs .......................................................................................................................... 9 Report No.: ORBDKX-WTW-P23090577 Page: 3 of 9 Report Format Version 3.0.2 GENERAL INFORMATION APPLICANT: PRIMAX ELECTRONICS LTD. MANUFACTURER: PRIMAX ELECTRONICS LTD. MODEL NAME: H1 MEASUREMENT STATNDARD ANSI/IEEE Std 149 2021 TESTED BY : , DATE : 2023.10.24 Leo Chen / Engineer PREPARED BY : , DATE : 2023.10.24 Johnny Liu / Supervisor APPROVED BY : , DATE : 2023.10.24 Ken Chan / Manager Report No.: ORBDKX-WTW-P23090577 Page: 4 of 9 Report Format Version 3.0.2 1. Test Methods The Antenna Gain Test is performed according to The ANSI/IEEE Std 149 12.3.1 Antenna Gain (Small size (< 42cm) Linear Polarization Antennas), using a two-axis support device and one fixed measurement antenna. The EUT is positioned along the required MAPS centerline fixture holder. The EUT is then stepped between 0 and 180 degrees along the theta axis in 15-degree increments. At each theta position, the phi axis is stepped from 0-360 degrees in 15-degree increments. Data is recorded using the Network analyzer for both theta and phi polarizations at each position. Depending on the protocol, an appropriate filter is used in the EMQuest software to process the data. Upon completion of the test, test results (angular dependent EIRP) is calculated at each measurement point and the required value is automatically calculated. This test procedure is repeated for frequency and configuration as required. 2. Description of the anechoic chamber: Length: 7.32 m Width: 3.66 m Height: 3.51 m Network Analyzer Measurement Antenna EUT Phi axis Theta axis H V Report No.: ORBDKX-WTW-P23090577 Page: 5 of 9 Report Format Version 3.0.2 3. Test Equipment List TYPE OF EQUIPMENT MODEL NUMBER SERIAL NUMBER C A L I B R AT I O N DUE D AT E (OTA3-HY) ETS Anechoic Chamber ETS-Lindgren AMS-8500 CT0000411-1132 N/A Measurement Software ETS-Lindgren EMQuest V1.14 build 31654 1281 N/A Multi-Axis Positioning System ETS-Lindgren 2090-OPTI 00086248 N/A Switch Control Agilent 3499A MY42005285 N/A Network Analyzer Agilent E5071C MY46104190 2024/5/28 4. Measurement Uncertainty Expanded Uncertainty for Measurement (k=2 or 95.45% Confidence Level) at Passive antenna test over frequency range:. FR…

Text truncated - open the document above for the full version.

Test Report

This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: ORBDKX-WTW-P23090577-2 Page: 1 of 9 Report Format Version 3.0.2 3D Antenna Measurement Summary Report REPORT NO.: ORBDKX-WTW-P23090577-2 MODEL NAME: H1 TESTED D AT E: 2023.10.11 ISSUED: 2023.10.24 APPLICANT : PRIMAX ELECTRONICS LTD. ADDRESS : No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. ISSUED BY: Bureau Veritas Consumer Products Services (Hong Kong) Limited, Taoyuan Branch Mobile Communications Laboratory ADDRESS: No.19, Hwa Ya 2nd Rd., Kwei shan Dist., Taoyuan City, Taiwan (R.O.C) The client to claim product certification, approval, or endorsement by TAF, CTIA or any government agencies, should not use this report. Report No.: ORBDKX-WTW-P23090577-2 Page: 2 of 9 Report Format Version 3.0.2 RELEASE CONTROL RECORD REPORT NO. REASON FOR CHANGE DATE ISSUED ORBDKX-WTW-P23090577-2 Original release 2023.10.24 TABLE OF CONTENTS GENERAL INFORMATION ................................................................................................................................. 3 1. Test Methods ............................................................................................................................................... 4 2. Description of the anechoic chamber: ........................................................................................................ 4 3. Test Equipment List ..................................................................................................................................... 5 4. Measurement Uncertainty .......................................................................................................................... 5 5. Testing Setup Photo ................................................................................................................................... 5 6. Antenna Radiation Performance ................................................................................................................ 5 7. 3D Antenna Patterns .................................................................................................................................. 6 APPENDIX. EUT photograph ............................................................................................................................ 9 Report No.: ORBDKX-WTW-P23090577-2 Page: 3 of 9 Report Format Version 3.0.2 GENERAL INFORMATION APPLICANT: PRIMAX ELECTRONICS LTD. MANUFACTURER: PRIMAX ELECTRONICS LTD. MODEL NAME: H1 MEASUREMENT STATNDARD ANSI/IEEE Std 149 2021 TESTED BY : , DATE : 2023.10.24 Leo Chen / Engineer PREPARED BY : , DATE : 2023.10.24 Johnny Liu / Supervisor APPROVED BY : , DATE : 2023.10.24 Ken Chan / Manager Report No.: ORBDKX-WTW-P23090577-2 Page: 4 of 9 Report Format Version 3.0.2 1. Test Methods The Antenna Gain Test is performed according to The ANSI/IEEE Std 149 12.3.1 Antenna Gain (Small size (< 42cm) Linear Polarization Antennas), using a two-axis support device and one fixed measurement antenna. The EUT is positioned along the required MAPS centerline fixture holder. The EUT is then stepped between 0 and 180 degrees along the theta axis in 15-degree increments. At each theta position, the phi axis is stepped from 0-360 degrees in 15-degree increments. Data is recorded using the Network analyzer for both theta and phi polarizations at each position. Depending on the protocol, an appropriate filter is used in the EMQuest software to process the data. Upon completion of the test, test results (angular dependent EIRP) is calculated at each measurement point and the required value is automatically calculated. This test procedure is repeated for frequency and configuration as required. 2. Description of the anechoic chamber: Length: 7.32 m Width: 3.66 m Height: 3.51 m Network Analyzer Measurement Antenna EUT Phi axis Theta axis H V Report No.: ORBDKX-WTW-P23090577-2 Page: 5 of 9 Report Format Version 3.0.2 3. Test Equipment List TYPE OF EQUIPMENT MODEL NUMBER SERIAL NUMBER C A L I B R AT I O N DUE D AT E (OTA3-HY) ETS Anechoic Chamber ETS-Lindgren AMS-8500 CT0000411-1132 N/A Measurement Software ETS-Lindgren EMQuest V1.14 build 31654 1281 N/A Multi-Axis Positioning System ETS-Lindgren 2090-OPTI 00086248 N/A Switch Control Agilent 3499A MY42005285 N/A Network Analyzer Agilent E5071C MY46104190 2024/5/28 4. Measurement Uncertainty Expanded Uncertainty for Measurement (k=2 or 95.45% Confidence Level) at Passive antenna test over frequ…

Text truncated - open the document above for the full version.

Test Report

This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: ORBDKX-WTW-P23090577-1 Page: 1 of 9 Report Format Version 3.0.2 3D Antenna Measurement Summary Report REPORT NO.: ORBDKX-WTW-P23090577-1 MODEL NAME: H1 TESTED D AT E: 2023.10.11 ISSUED: 2023.10.24 APPLICANT : PRIMAX ELECTRONICS LTD. ADDRESS : No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C. ISSUED BY: Bureau Veritas Consumer Products Services (Hong Kong) Limited, Taoyuan Branch Mobile Communications Laboratory ADDRESS: No.19, Hwa Ya 2nd Rd., Kwei shan Dist., Taoyuan City, Taiwan (R.O.C) The client to claim product certification, approval, or endorsement by TAF, CTIA or any government agencies, should not use this report. Report No.: ORBDKX-WTW-P23090577-1 Page: 2 of 9 Report Format Version 3.0.2 RELEASE CONTROL RECORD REPORT NO. REASON FOR CHANGE DATE ISSUED ORBDKX-WTW-P23090577-1 Original release 2023.10.24 TABLE OF CONTENTS GENERAL INFORMATION ................................................................................................................................. 3 1. Test Methods ............................................................................................................................................... 4 2. Description of the anechoic chamber: .........................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Nelson Chou(Manager)
[email protected]+886-2-2798-1681Fax: +886-2-8797-1565

Test Firm

Bureau Veritas CPS(H.K.) Ltd., Taoyuan BranchLiu Ken
[email protected]+886-3-2600609Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
415C2.40 GHz - 2.48 GHz23.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Primax Electronics Ltd

EMJ-BHS2705

Wireless Headset

Aug 28, 2026

Equipment Class

DTS - Digital Transmission System
EMJMMOBTN5O

wegear MW1 Creator Mouse

Aug 22, 2024

Equipment Class

DTS - Digital Transmission System
EMJDDGRFN5

wegear MW1 2.4G Dongle

Aug 22, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Dongle - FCC ID EMJDTPA-P002D - Primax Electronics Ltd
EMJDTPA-P002D

Dongle

Jan 14, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Mouse - FCC ID EMJMTPA-P007M - Primax Electronics Ltd
EMJMTPA-P007M

Wireless Mouse

Jul 18, 2023

Equipment Class

DTS - Digital Transmission System