FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Starkey Laboratories Inc/
  3. EOA-24EDGCIC

EOA-24EDGCICEdge AI CIC

Starkey Laboratories Inc
Edge AI CIC - FCC ID EOA-24EDGCIC - Starkey Laboratories Inc
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 17, 2024
Application Purpose
Original Equipment
Date of Application
Jul 17, 2024
Equipment Note
Edge AI CIC
Frequency Range
2402.00000000 - 2480.00000000
Company
Starkey Laboratories Inc
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗
↗
↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Your Wireless Custom Hearing Aid User Manual Wireless Products CIC (Completely-In-Canal) P00002033 Warnings, Cautions, & Notices | 32 | Warnings, Cautions, & Notices REQUIRED HEARING AID INFORMATION The following additional information is provided in compliance with U.S. Food and Drug Administration (FDA) regulations: WARNING: People younger than 18 should go to a doctor before using this. People younger than 18 years old need specialized care, and using this without a medical evaluation may worsen impairment or disability. A hearing aid user who is younger than 18 should have a recent medical evaluation from a doctor, preferably an ear-nose-throat doctor (an ENT). Before using this, a doctor should determine that the use of a hearing aid is appropriate. WARNING: to Hearing Aid Dispensers: You should advise a prospective hearing aid user to consult promptly with a doctor, preferably an ear specialist such as an ENT, before dispensing a hearing aid if you determine through inquiry, actual observation, or review of any other available information concerning the prospective user, that the prospective user has any of the following conditions: • Visible deformity of the ear, either congenital or traumatic • Fluid, pus, or blood coming out of the ear within the previous 6 months • Pain or discomfort in the ear • History of excessive ear wax or suspicion that something is in the ear canal • Dizziness, either recent or long-standing • Sudden, quickly worsening, or fluctuating hearing loss within the previous 6 months • Hearing loss or ringing (tinnitus) only in one ear or a noticeable difference in hearing between ears • Audiometric air-bone gap equal to or greater than 15 dB at 500 Hz, 1000 Hz, and 2000 Hz WARNING: to Hearing Aid Dispenser, Outputs over 132 dB SPL: You should exercise special care in selecting and fitting a hearing aid with a maximum output that exceeds 132 dB SPL because it may impair the remaining hearing of the hearing aid user. International Use Your hearing aids are approved to operate at a radio frequency that is specific to your country or region and might not be approved for use outside your country or region. Be aware that operation during international travel may cause interference to other electronic instruments, or other electronic instruments may cause interference to your hearing aids. We are required by regulations to provide the following warnings: WARNING: Use of wireless hearing aids directly next to other electronic equipment should be avoided because it could result in improper performance. If such use is necessary, note as to whether your hearing aids and the other equipment are operating normally. WARNING: Use of accessories, components or replacement parts other than those provided by the manufacturer of your hearing aids could result in increased electromagnetic emissions and decreased electromagnetic immunity and could result in degradation of performance. WARNING: If Portable Radio Frequency communications equipment is used closer than 30 cm (12 inches) from your hearing aid, degradation of the performance of your hearing aid could result. If this occurs, move away from the communications equipment. WARNING: The stability of the hearing aid is designed for normal use. Avoid physical impacts to the ear when wearing a hearing aid that may cause the device to break or component of the device to become detached. This may lead to lacerations of the ear canal or perforation of the ear drum. If this occurs, it is strongly recommended to see a physician for evaluation and safe removal. WARNING: If the hearing aid drops onto a hard surface, it could cause the hearing aid to break or become damaged. This includes mechanical stress or shock of the device. Ensure the hearing aid is intact before placing it in the ear. If you find the device is damaged, discontinue use and see your hearing professional. WARNING: Repeated stress to the removal handle may cause it to break. If the removal handle breaks and you’re unable to remove the device carefully, it is recommended to see a physician for safe removal. WARNING TO HEARING CARE PROFESSIONAL A hearing care professional should advise a prospective sound generator (tinnitus masker) user to consult promptly with a licensed physician (preferably an ear specialist) before using a sound generator if the hearing care professional determines through inquiry, actual observation or review or any other available information concerning the prospective user that the prospective user has any of the following conditions: • Visible congenital or traumatic deformity of the ear • History of active drainage from the ear within the previous 90 days • History of sudden or rapidly progressive hearing loss within the previous 90 days • Acute or chronic dizziness • Unilateral hearing loss of sudden or recent onset within the previous 90 days WARNING: There are some potential concerns associated with the use of any sound generating tinnitus therapy instrument. Among them are the potential for worsening of tinnitus, a possible change in hearing thresholds, and possible skin irritation at the point of contact with the hearing aid. Multiflex Tinnitus Technology has been designed to minimize these concerns. However, should you experience or notice any of the above conditions or any dizziness, nausea, headaches or heart palpitations, you should immediately discontinue use of the hearing aid and seek a consultation with a medical, audiology or other hearing care professional. As with any hearing aid, misuse of the tinnitus therapy instrument could present some potentially harmful effects. Care should be taken to prevent the unauthorized use and to keep the hearing aid out of the reach of children and pets. Warnings, Cautions, & Notices | 54 | Warnings, Cautions, & Notices FALL ALERT FEATURE The Fall Alert feature can be used to notify others should you fall or experience a non-fall-related event. This feature can be configured to send an SMS text …

Text truncated - open the document above for the full version.

Attestation Statements

Sta rkey 6700 Washington Avenue S Eden Prairie, Minnesota 55344 T: 1.800.328.8602 Hear better. Live better. srarkepueati 30 April 2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Attestation regarding 8covered9 equipment and the Covered List FCC ID: EOA-24EDGCIC To whom it may concern, Per 2.911(d)(5)(i), Starkey Laboratories, Inc. certifies that the equipment for which authorization is sought is not <covered= equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Per 2.911(d)(5) (ii), Starkey Laboratories, Inc. certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing <covered= equipment. Sincerely, g ee [ g r i l William J. Mitchell, PE Principal Wireless and Safety Regulatory Engineer 952-918-5683 [email protected] Starkey logo and Hear better. Live better. are registered trademarks of Starkey Laboratories, Inc.

Attestation Statements

Starkey | 6700 Washington Avenue S Eden Prairie, Minnesota 55344 T: 1.800.328.8602 Hear better. Live better. Starkey.com March 30, 2023 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: section 2.911(d)(7) filing To whom it may concern, This letter is to confirm that Starkey Laboratories, Inc. has accepted responsibility to act as the agent for service of process as acknowledged by the applicant, Starkey Laboratories, Inc. William J. Mitchell confirms he is not associated with or part of any TCB or test lab. U.S. Agent: William J. Mitchell Title: Principal Wireless and Safety Regulatory Engineer Company Name: Starkey Laboratories, Inc. Address: | 6600 Washington Avenue, South, Eden Prairie, MN 55344 Telephone No: | 952-918-5683 Email: | [email protected] FRN (FCC Registration | 0015964463 Number): The applicant accepts and acknowledges the obligation to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Signature of Applicant (must be signed by the contact of record in the FCC database for the applicant grantee code): luc J Duthil | Feb Signature of U.S. Agent (if different from applicant): Dp bet! Name: William J. Mitchell Name: Date: March 30, 2023 Date: Starkey logo and Hear better. Live better. are registered trademarks of Starkey Laboratories, Inc.

Cover Letter(s)

Sta rkey | 6700 Washington Avenue S Eden Prairie, Minnesota 55344 T: 1.800.328.8602 Hear better. Live better. Starkey.coni 30 April 2024 Federal Communications Commission 45 L Street, NE Washington, DC 20554 Attention: Application Examiner Reference: Certification: | Part 15.247 Intentional Radiator Applicant: Starkey Laboratories, Inc. Equipment: Low Power Device (2400-2483.5 MHz) Model #: Edge AI Custom CIC Hearing Aid FCC ID: EOA-24EDGCIC Dear Sir/Madam: Enclosed please find an FCC EOA-24EDGCIC certification application. The device is a wireless hearing aid intended for use by the hearing impaired. The wireless features are used during the initial fitting of a hearing aid to program the hearing aid and used during normal usage to communicate control information and digital audio to and from any properly configured Bluetooth Low Energy compliant accessory and between a binaural pair of Edge AI hearing aids. Further details and supporting documents are attached. Should you have any questions, please feel free to contact the undersigned. Sincerely, Meee y Cect hil William J. Mitchell, PE Principal Wireless and Safety Regulatory Engineer 952-918-5683 [email protected] Starkey logo and Hear better. Live better. are registered trademarks of Starkey Laboratories, Inc.

Cover Letter(s)

Sta rkey 6700 Washington Avenue S Eden Prairie, Minnesota 55344 T: 1.800.328.8602 Hear better. Live better. Starkey.com 9 July 2024 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Request for confidentiality Applicant: Starkey Laboratories, Inc. FCC ID: EOA-24EDGCIC To whom it may concern: Permanent Confidentiality Request is hereby submitted by Starkey Laboratories, Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential: e Schematics e Detailed Block diagrams e Detailed Operational/Functional Description Rationale for request for confidentiality: Starkey Laboratories, Inc. has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. Disclosure of the short-term confidential portions of this application during the period of importation and/or distribution would reveal key aspects of proprietary technology to competitors and diminish the value of our investment in research and development. Sincerely, William J. Mitchell, PE , Principal Wireless and Safety Regulatory Engineer 952-918-5683 [email protected] Starkey logo and Hear better. Live better. are registered tradernarks of Starkey Laboratories, Inc.

External Photos

Edge AI Custom wireless CIC Hearing Aid (scale in cm) Top view Side 1 Side 2 Side 3 Side 4 Bottom view

ID Label/Location Info

28 | Additional guidance • Immunity to power frequency magnetic fields at a field level of 30 A/m, as well as proximity magnetic fields as defined in table 11 of 60601-1-2. • Immunity to ESD levels of +/- 8 kV conducted discharge and +/- 15 kV air discharge. The expected service life is 3 years. WIRELESS NOTICES FCC ID: EOA-24EDGCIC IC: 6 903A-24EDGCIC (Edge AI CIC, Vitality AI CIC, OuieZen SK ED CIC) EU ADVERSE EVENT REPORTING Any serious incident that has occurred in relation to your Starkey device should be reported to your local Starkey representative and the Competent Authority of the Member State in which you are established. A serious incident is defined as any malfunction, deterioration in the characteristics and/or performance of the device, or inadequacy in the device user manual/ labeling which could lead to the death or serious deterioration in the state of health of the user, OR could do so upon recurrence. FCC information These devices comply with part 15 of the FCC rules and with ISED Canada license-exempt RSS standards. Operation is subject to the following two conditions: (1) The device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. Hereby, Starkey Laboratories, Inc. declares that the CIC is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.A copy of the Declaration of Conformity can be obtained from the address below or from docs.starkeyhearingtechnologies.com. Hereby, Starkey Laboratories, Inc. declares that the CIC is in compliance with the UK Radio Equipment Regulations SI 2017 as amended. A copy of the UK Declaration of Conformity can be obtained from the following addresses and from docs.starkeyhearingtechnologies.com. Additional guidance | 29 Regulatory information For service or repair, please contact your hearing care professional first. If necessary, you can send your hearing aids to: Starkey Laboratories, Inc. 6700 Washington Ave. South Eden Prairie, MN 55344 USA www.starkey.com Starkey Laboratories (Germany) GmbH Weg beim Jäger 218-222 22335 Hamburg Germany UK Authorised Person: Starkey UK William F. Austin House Pepper Rd, Hazel Grove Stockport SK7 5BX, UK www.starkey.co.uk Waste from electronic equipment must be handled according to local regulations Consult user manual Keep dry Instructions for Disposal of Old Electronics Starkey Laboratories, Inc. encourages, the EU requires, and your local community laws may require, that your hearing aids be disposed of via your local electronics recycling/disposal process. At the benefit of disposal/recycling personnel, please remove zinc air battery from the battery compartment according to the instructions in the battery section prior to recycling. In addition, please include this user manual when disposing of your hearing aids.

ID Label/Location Info

Sta rkey 6700 Washington Avenue S Eden Prairie, Minnesota 55344 T: 1.800.328.8602 Hear better. Live better. Starkeyicom 30 April 2024 Federal Communications Commission 45 L Street, NE Washington, DC 20554 Subject: FCC ID labeling on EOA-24EDGCIC wireless hearing aids Re: Response to Inquiry to FCC To whom it may concern, Consistent to the direction provided on a previous similar product via your July 12, 2010 Response to Inquiry to FCC concerning approval by the FCC for alternate labeling to our hearing aid under CFR 2.925(f), we are placing the FCC ID label for the EOA-24EDGCIC wireless hearing aids in the User Manual. Consistent to the direction provided on the earlier product, we are including the following documents with our submission for certification of Starkey’s wireless hearing aids having an FCC ID of EOA-24EDGCIC. ° The FCC Response to Inquiry to FCC e Supporting documents similar to those associated with that Inquiry ° Figure 1 below showing curved nature, relative size, and available printed area and FCC ID of EOA-24EDGCIC hearing aids. ° The relevant page from the User Manual showing the alternate FCC ID marking location and other Part 15 required wording. If you have any questions or comments, please do not hesitate to contact me. Sincerely, William J. Mitchell, PE Principal Wireless and Safety Regulatory Engineer 952-918-5683 [email protected] FCC ID: EOA-24EDGCIC Figure 1 (scale in inches and mm) Starkey logo and Hear better. Live better. are registered trademarks of Starkey Laboratories, Inc.

ID Label/Location Info

Outer package showing location of label Label goes here

ID Label/Location Info

2410123456 72096-SHT MX GTIN: Designed in USA 2024-05-20 IC:FCC ID: -10C 45C 10% 95% STARKEY EDGE AI 24 CIC Starkey Laboratories Inc.6700 Washington Ave. SouthEden Prairie, MN 55344 USAStarkey Laboratories(Germany) GmbHWeg beim Jäger 218-222 22335 Hamburg, Germany 205-240015 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: (1) Thisdevice may not cause harmful interference, and (2) thisdevice must accept any interference received, includinginterference that may cause undesired operation. R (01)00840388202906(11)20240520(21)2410123456 UDI: EOA-24EDGCIC 6903A-24EDGCIC (Edge AI CIC) 00840388202906 ZincAir1 PK

Internal Photos

Edge AI Custom CIC Hearing Aid Internal photos Faceplate top and shell Faceplate side 1 Faceplate side 2 Faceplate bottom showing battery door and antenna PCBA top PCBA bottom Unfolded PCBA top Unfolded PCBA bottom

RF Exposure Info

This report must not be used to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the U.S. Government. This Report shall not be reproduced, except in full without written approval of the laboratory. Starkey Laboratories, Inc. EDGE AI CIC FCC 1.1307:2023 Bluetooth Low Energy Report: STAK0333.14, Issue Date: July 9, 2024 TABLE OF CONTENTS 2023.04.17 Section Page Number Certificate of Evaluation .................................................................................. 3 Revision History .............................................................................................. 4 Accreditations .................................................................................................. 5 Facilities .......................................................................................................... 6 Product Description ......................................................................................... 7 Exposure Condition ......................................................................................... 8 Exemption From RF Exposure Evaluation ...................................................... 9 End of Report .................................................................................................. 12 Report No. STAK0333.142/12 CERTIFICATE OF EVALUATION 2018-09-14 Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. This report reflects only those tests from the referenced standards shown in the certificate of test. It does not include inspection or verification of labels, identification, marking or user information. As indicated in the Statement of Work sent with the quotation, Element’s standard process is to always use the latest published version of the test methods even when earlier versions are cited in the test specification. Issuance of a purchase order was de facto acceptance of this approach. Otherwise, the client would have advised Element in writing of the specific version of the test methods they wanted applied to the subject testing Last Date of Evaluation: July 9, 2024 Starkey Laboratories, Inc. EUT: EDGE AI CIC RF Exposure Evaluation Standards Specification Method FCC 1.1307:2024 FCC 1.1307:2024 Results Method Clause Description Applied Results Comments (b)(3)(i)(B) Exemption From RF Exposure Evaluation Yes Pass None Deviations From Evaluation Standards None Approved By: Donald Facteau, Process Architect Report No. STAK0333.143/12 REVISION HISTORY 2018.07.17 Revision Number Description Date (yyyy-mm-dd) Page Number 00 None Report No. STAK0333.144/12 ACCREDITATIONS AND AUTHORIZATIONS 2021.09.01 United States FCC - Designated by the FCC as a Telecommunications Certification Body (TCB). Certification chambers, Open Area Test Sites, and conducted measurement facilities are listed with the FCC. A2LA - Each laboratory is accredited by A2LA to ISO / IEC 17025, and as a product certifier to ISO / IEC 17065 which allows Element to certify transmitters to FCC and IC specifications. Canada ISED - Recognized by Innovation, Science and Economic Development Canada as a Certification Body (CB) and as a CAB for the acceptance of test data. European Union European Commission – Recognized as an EU Notified Body validated for the EMCD and RED Directives. United Kingdom BEIS – Recognized by the UK as an Approved Body under the UK Radio Equipment and UK EMC Regulations. Australia/New Zealand ACMA - Recognized by ACMA as a CAB for the acceptance of test data. Korea MSIT / RRA - Recognized by KCC’s RRA as a CAB for the acceptance of test data. Japan VCCI - Associate Member of the VCCI. Conducted and radiated measurement facilities are registered. Taiwan BSMI – Recognized by BSMI as a CAB for the acceptance of test data. NCC - Recognized by NCC as a CAB for the acceptance of test data. Singapore IDA – Recognized by IDA as a CAB for the acceptance of test data. Israel MOC – Recognized by MOC as a CAB for the acceptance of test data. Hong Kong OFCA – Recognized by OFCA as a CAB for the acceptance of test data. Vietnam MIC – Recognized by MIC as a CAB for the acceptance of test data. SCOPE For details on the Scopes of our Accreditations, please visit: California Minnesota Oregon Texas Washington Report No. STAK0333.145/12 FACILITIES 2023.09.21 Testing was performed at the following location(s) Location Labs (1) Address A2LA (2) ISED (3) BSMI (4) VCCI (5) CAB (6) FDA (7) ☐ California OC01-17 41 Tesla Irvine, CA 92618 (949) 861-8918 3310.04 2834B SL2-IN-E-1154R A-0029 US0158 TL-55 ☒ Minnesota MN01-11 9349 W Broadway Ave. Brooklyn Park, MN 55445 (612) 638-5136 3310.05 2834E SL2-IN-E-1152R A-0109 US0175 TL-57 ☐ Oregon EV01-12 6775 NE Evergreen Pkwy #400 Hillsboro, OR 97124 (503) 844-4066 3310.02 2834D SL2-IN-E-1017 A-0108 US0017 TL-56 ☐ Plano Texas PT01-15 1701 E Plano Pkwy, Ste 150 Plano, TX 75074 (972) 509-2566 214.19 US0054 ☐ Texas TX01-09 3801 E Plano Pkwy Plano, TX 75074 (469) 304-5255 3310.03 2834G SL2-IN-E-1158R A-0201 US0191 TL-54 ☐ Washington NC01-05 19201 120th Ave NE Bothell, WA 98011 (425) 984-6600 3310.06 2834F SL2-IN-E-1153R A-0110 US0157 TL-67 ☐ Offsite N/A See Product Description N/A N/A N/A N/A N/A N/A See data sheets for specific labs (1) The lab designations denote individual rooms within each location. (OC01, OC02, OC03, etc.) (2) A2LA Certificate No. (3) ISED Company No. (4) BSMI No. (5) VCCI Site Filing No. (6) CAB Identifier. Recognized Phase I CAB for ISED, ACMA, BSMI, IDA, KCC/RRA, MIC, MOC, NCC, OFCA (7) FDA ASCA No. Report No. STAK0333.146/12 PRODUCT DESCRIPTION 2018-07-17 Client and Equipment Under Evaluation Information Company Name: Starkey Laboratories, Inc. Address: 6600 Washi…

Text truncated - open the document above for the full version.

Test Report

Edge AI CIC Antenna Description Antenna Type The antenna is a monopole antenna containing a feedline flex and a removal handle. The peak gain of the antenna is -2.72 dBi (See Calculations at the end) Date of antenna pattern measurement: March 05, 2024 Figure 1 CIC Antenna (Scale in cm) Three-Dimensional Pattern (Scale in dBm) Figure 2a Three Dimensional Antenna Pattern Figure 2b Hearing Aid Antenna Elevation and Azimuth Cuts Antenna Pattern Measurement Information The antenna patterns shown in Figures 2a were measured using a MVG SG24L antenna test system, serial number ATL3843S located at Starkey Laboratories, Inc., 6600 Washington Avenue, South, Eden Prairie, MN 55344. The system was calibrated on October 12, 2023, and due for calibration in October 2024. Signal levels were measured using a Keysight N9020B MXA Signal Analyzer (Spectrum Analyzer). serial number MY63470227, calibrated on May 04, 2023 and due for calibration on May 04, 2025. The antenna pattern plots in Figures 2 are generated by the SG24L test system software. Figure 3a Overall view of SG24L test chamber, showing ring of receiving antennas Figure 3b Test stand in SG24L test chamber Figure 3c close-up of unit under test in test chamber Antenna Gain Measurement Information The MVG SG24L antenna test system runs internal scripts that yield the maximum EIRP from each radiated power measurement. From there, the following equation could be used to calculate the antenna gain in dBi. Max Antenna Gain = Max EIRP – Power at antenna pads Where, Power at antenna pads = BLE Chipset Power Setting – Simulated PCB Insertion Loss Subtracting the conducted power at the antenna pads from the EIRP value, yields the antenna gain as follows: • Max Antenna Gain = -2.72 dBi

Test Report

This report must not be used to claim product certification, approval, or endorsement by A2LA or any agency of the U.S. Government. This Report shall not be reproduced, except in full without written approval of the laboratory. Starkey Laboratories, Inc. Edge AI CIC FCC 15.247:2024 RSS-247 Issue 3:2023 RSS-Gen Issue 5:2018+A1:2019+A2:2021 Bluetooth Low Energy (DTS) Radio Report: STAK0333.3 Rev. 0, Issue Date: July 2, 2024 TABLE OF CONTENTS 2023.04.17 Section Page Number Certificate of Test ............................................................................................ 3 Revision History .............................................................................................. 5 Accreditations .................................................................................................. 6 Facilities .......................................................................................................... 7 Measurement Uncertainty ............................................................................... 8 Test Setup Block Diagrams ............................................................................. 9 Product Description ......................................................................................... 12 Power Settings And Antenna Information ....................................................... 13 Configurations ................................................................................................. 14 Modifications ................................................................................................... 15 Occupied Bandwidth (99%) ............................................................................. 16 Duty Cycle ....................................................................................................... 20 DTS Bandwidth (6dB) ..................................................................................... 24 Output Power .................................................................................................. 28 Equivalent Isotropic Radiated Power (EIRP) ................................................... 32 Power Spectral Density ................................................................................... 34 Band Edge Compliance .................................................................................. 38 Spurious Conducted Emissions ...................................................................... 41 Spurious Radiated Emissions ......................................................................... 47 End of Report .................................................................................................. 57 Report No. STAK0333.32/57 CERTIFICATE OF TEST 2022.04.01 Product compliance is the responsibility of the client; therefore, the tests and equipment modes of operation represented in this report were agreed upon by the client, prior to testing. The results of this test pertain only to the sample(s) tested. The specific description is noted in each of the individual sections of the test report supporting this certificate of test. This report reflects only those tests from the referenced standards shown in the certificate of test. It does not include inspection or verification of labels, identification, marking or user information. As indicated in the Statement of Work sent with the quotation, Element’s standard process is to always use the latest published version of the test methods even when earlier versions are cited in the test specification. Issuance of a purchase order was de facto acceptance of this approach. Otherwise, the client would have advised Element in writing of the specific version of the test methods they wanted applied to the subject testing. Last Date of Test: June 11, 2024 Starkey Laboratories, Inc. EUT: Edge AI CIC Radio Equipment Testing Standards Specification Method FCC 15.247:2024 ANSI C63.10:2013 RSS-247 Issue 3:2023 RSS-Gen Issue 5:2018+A1:2019+A2:2021 Guidance FCC KDB 558074 v05r02:2019 Notice 2021 - CEB0001 Results Test Description Result FCC Section(s) RSS Section(s) ANSI C63.10 Section(s) Comments Powerline Conducted Emissions N/A 15.207 RSS-Gen 8.8 6.2 Not required for a battery powered EUT. Occupied Bandwidth (99%) Pass KDB 558074 -2.1 RSS-Gen 6.7 6.9.3 Duty Cycle Pass KDB 558074 -6.0 RSS-Gen 3.2 11.6 DTS Bandwidth (6 dB) Pass 15.247(a)(2), KDB 558074 -8.2 RSS-247 5.2(a) 11.8.2 Output Power Pass 15.247(b)(3), KDB 558074 -8.3.1 RSS-247 5.4(d, f), RSS-Gen 6.12 11.9.1.1 Equivalent Isotropic Radiated Power Pass 15.247(b)(3), KDB 558074 -8.3.1 RSS-247 5.4(d, f), RSS-Gen 6.12 11.9.1.1 Power Spectral Density Pass 15.247(e), KDB 558074 -8.4 RSS-247 5.2(b) 11.10.2 Band Edge Compliance Pass 15.247(d), KDB 558074 -8.5 RSS-247 5.5 11.11 Spurious Conducted Emissions Pass 15.247(d), KDB 558074 -8.5 RSS-247 5.5 11.11 Spurious Radiated Emissions Pass …

Text truncated - open the document above for the full version.

Contact Information

Applicant

William John Mitchell(Principal Regulatory Affairs Engineer)
[email protected]952-918-5683Fax: 952 828-6972

Test Firm

Element Materials Technology Minneapolis - BrooklyRenee Walker
[email protected]503 844 4066

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. The antenna(s) used for this transmitter must not transmit simultaneously with any other co-located antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.

Other Applications from Starkey Laboratories Inc

Starlink Edge TV - FCC ID EOA-24TVE - Starkey Laboratories Inc
EOA-24TVE

Starlink Edge TV

Aug 18, 2024

Equipment Class

DTS - Digital Transmission System
Edge AI ITE right - FCC ID EOA-24EDGITERCH - Starkey Laboratories Inc
EOA-24EDGITERCH

Edge AI ITE right

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
Edge AI mRIC R - FCC ID EOA-24EDGMRIC - Starkey Laboratories Inc
EOA-24EDGMRIC

Edge AI mRIC R

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
Edge AI ITE left - FCC ID EOA-24EDGITELCH - Starkey Laboratories Inc
EOA-24EDGITELCH

Edge AI ITE left

Jul 17, 2024

Equipment Class

DTS - Digital Transmission System
Genesis AI - FCC ID EOA-24GENR312 - Starkey Laboratories Inc
EOA-24GENR312

Genesis AI

Jul 24, 2023

Equipment Class

DTS - Digital Transmission System