FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Timex Group USA, Inc./
  3. EP9-TMXM010

EP9-TMXM010Digital Heart Rate Monitor (HRM) Strap

Timex Group USA, Inc.
Digital Heart Rate Monitor (HRM) Strap - FCC ID EP9-TMXM010 - Timex Group USA, Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Feb 15, 2013
Application Purpose
Original Equipment
Date of Application
Feb 15, 2013
Equipment Note
Digital Heart Rate Monitor (HRM) Strap
Frequency Range
0.13750000 - 0.14100000
Company
Timex Group USA, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

©2013 Timex Group USA, Inc. TIMEX, INDIGLO, ROAD TRAINER and NIGHT-MODE are trademarks of Timex Group B.V. and its subsidiaries. IRONMAN ® and MDOT are registered trademarks of World Triathlon Corporation. Used here by permission. HEART ZONES is a registered trademark of Sally Edwards. W290-NA 014-095000 English page 1 Français page 49 Español página 101 Português página 151 ROAD TRAINER ™ DIGITAL HEART RATE MONITOR digital heart rate monitor Contents Overview ..............................................................................................................1 A Fit Heart ......................................................................................................1 Watch Buttons ................................................................................................3 INDIGLO ® night-light with NIGHT-MODE ® feature ............................................3 Display Icons ..................................................................................................4 Resources ......................................................................................................5 Determining Your Optimal Heart Rate Zone.....................................................6 Digital Heart Rate Monitor ..................................................................................7 Before You Begin ............................................................................................7 To Use Your Digital Heart Rate Monitor ...........................................................7 Digital Heart Rate Monitor Notes & Tips ..........................................................9 Time of Day ........................................................................................................10 To Set or Adjust the Time, Date, and Audibles ..............................................11 To Switch Time Zones ..................................................................................14 Time of Day Notes & Tips .............................................................................14 Chrono ................................................................................................................16 Chrono Terminology .....................................................................................16 To Operate the Chrono .................................................................................17 Chrono Mode Notes & Tips ...........................................................................18 Interval Timer ....................................................................................................19 To Set the Interval Timer ..............................................................................20 To Operate the Interval Timer .......................................................................21 Interval Timer Mode Notes & Tips .................................................................22 Overview Congratulations! With your purchase of the Timex ® IRONMAN ® Digital Heart Rate Monitor you have hired a new personal trainer. Your Digital Heart Rate Monitor offers you the ability to track, store, and analyze key indicators of your personal fitness level for up to 50 laps. You will find your Digital Heart Rate Monitor to be a user-friendly fitness tool. But, like any new device, you should take the time to familiarize yourself with its components to optimize its usefulness. So, check out the features and functions of your Digital Heart Rate Monitor to develop a basic understanding of this fitness tool. But most of all, enjoy your new partner on the road to increased fitness! A Fit Heart Recent fitness findings indicate that anyone can get fit and stay fit without being overzealous. It can be as simple as: v Exercising 3 to 4 times per week. v Exercising for 30 to 45 minutes during each exercise session. v Exercising at the appropriate heart rate. Heart rate represents the effects of exercise on all parts of the body. Recovery ............................................................................................................23 About Recovery Heart Rate ...........................................................................23 To Manually Determine a Recovery Heart Rate .............................................24 Review ................................................................................................................26 To Review Workout Data ..............................................................................27 Review Mode Notes & Tips ...........................................................................28 Alarm ..................................................................................................................29 To Set the Alarm ..........................................................................................30 Alarm Mode Notes & Tips .............................................................................31 HRM Setup .........................................................................................................32 To Set a Target Heart Rate Zone...................................................................33 To Set Other HRM Setup Options ..................................................................34 User Info .............................................................................................................34 Digital Heart Rate Monitor Notes & Tips ........................................................35 Care & Maintenance ..........................................................................................36 Digital Heart Rate Monitor ............................................................................36 Heart Rate Sensor Battery ............................................................................37 Watch Battery Replacement .........................................................................38 INDIGLO ® night-light ..................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

1(1) Attention: Application Examiner Re: Request for confidentiality Applicant: Timex Group USA Inc. FCC ID: EP9-TMXM010 To whom it may concern, Permanent Confidentiality Request Request is hereby submitted by Timex Group USA Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential:  Schematics  Detailed Block diagrams  Detailed Operational/Functional Description Rationale for request for confidentiality: Timex Group USA Inc. has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. The fee for confidentiality has been submitted along with the fee for certification.] If you have questions or need further information, please contact the undersigned. Sincerely, Quality Regulatory Engineer Timex Group USA Inc.

Cover Letter(s)

Letter of Agency I appoint Intertek Testing Services NA Inc. to act on our behalf in front of the Federal Communications Commission with respect to all matters relating to certification of equipment under the FCC rules until further notice. I further certify that no party (as defined in 1.2002 of CFR 47, 1995) to this application, including myself, is subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.,853A. Equipment: _M010 - Digital Heart Rate Monitor (HRM) Strap ________________________________________________________________________ ________________________________________________________________________ _______________________________________________________________________ Dated this _12__day of__December___, 2012_. _____________________________________ Signature ___Sam Everett________________________ Name _Quality Regulatory Engineer_____________ Title _Timex Group USA Inc._________________ Company _(203) 346-5603 _______________________ Telephone

ID Label/Location Info

BACK VIEW FRONT VIEW Concept Sketch TIME X CONFIDENTIAL AND PROPRIETARY INFORMATION . This document and the information it gives, are the property of TIMEX Corporation. The information is given in confidence for a limited purpose. It is not to be divulged and is not to be used beyond that purpose. Program Name: HRM Digital TransmitterProject Number: 09066EModel Number: 010Business Group: Health and Fitness Brand Name: TimexIssue: 04Part Description: Color sketch Development Number: 09066E01Date: 08-Nov-2012 Designer/Location: Yiu-Fai Yan / HKDrawn by/Location: Yiu-Fai Yan / HK Style Number: 5K7240

Test Report

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Emissions Report for Timex Group USA Inc on the M010 Page 1 of 34 EMISSIONS TEST REPORT Report Number: 100961088BOX-008 Project Number: G100961088 Report Issue Date: 11/28/2012 Product Designation: M010 Standards: CFR47 FCC Part 15:2012 Subpart C Section 15.209 Industry Canada RSS-210 Issue 8 December 2010 IC RSS-Gen Issue 3 December 2010 Section 7.2.5 Table 6+Notice DRS 2012-DRS0126 Tested by: Client: Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 Timex Group USA Inc 555 Christian Road Middlebury, CT 06762 Report prepared by Report reviewed by Kouma Sinn / Senior Project Engineer, EMC Nicholas Abbondante / Transmitter Staff Engineer, EMC Intertek Report Number: 100961088BOX-008 Issued: 11/28/2012 Emissions Report for Timex Group USA Inc on the M010 Page 2 of 34 1 Introduction and Conclusion The tests indicated in section 2.0 were performed on the product constructed as described in section 3.0. The remaining test sections are the verbatim text from the actual data sheets used during the investigation. These test sections include the test name, the specified test Method, a list of the actual Test Equipment Used, documentation Photos, Results and raw Data. No additions, deviations, or exclusions have been made from the standard(s) unless specifically noted. Based on the results of our investigation, we have concluded the product tested complies with the requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s) tested. 2 Test Summary Section Test full name Result 3 Client Information -- 4 Description of Equipment Under Test -- 5 System Setup and Method -- 6 Fundamental Radiated Emissions FCC Part 15:2012 Subpart C 15.209(a) IC RSS-210 Issue 8 December 2010 and IC RSS-Gen Issue 3 December 2010 Section 7.2.5 Table 6 Pass 7 Transmitter Spurious Emissions Below 30MHz FCC Part 15:2012 Subpart C 15.209(a) IC RSS-210 Issue 8 December 2010 and IC RSS-Gen Issue 3 December 2010 Section 7.2.5 Table 6 Pass 8 Transmitter Spurious Emissions Above 30MHz FCC Part 15:2012 Subpart C 15.209(a) IC RSS-210 Issue 8 December 2010 and IC RSS-Gen Issue 3 December 2010 Section 7.2.5 Table 6 Pass -- Receiver Spurious Emissions Below 30MHz FCC Part 15:2012 Subpart B 15.109, IC RSS-Gen Issue 3 December 2010: Section 6.0 N/A* -- Receiver Spurious Emissions Above 30MHz FCC Part 15:2012 Subpart B 15.109, IC RSS-Gen Issue 3 December 2010: Section 6.0 N/A* 9 20dB Bandwidth FCC Part 15:2012 Subpart C 15.215 IC RSS-Gen Issue 3 December 2010 Section 4.6 Pass 10 Revision History -- * - The device is a transmitter only Intertek Report Number: 100961088BOX-008 Issued: 11/28/2012 Emissions Report for Timex Group USA Inc on the M010 Page 3 of 34 3 Client Information This EUT was tested at the request of: Company: Timex Group USA Inc 555 Christian Road Middlebury, CT 06762 Contact: Sam Everett Telephone: (203) 346-5603 Fax: (203) 573-5139 Email: [email protected] 4 Description of Equipment Under Test Equipment Under Test Description Manufacturer Model Number Serial Number Heart Rate Monitor Timex M010 204 Receive Date: 11/19/2012 Received Condition: Good Type: Production Description of Equipment Under Test (provided by client) The device is a Heart Rate Monitor. It utilizes an integrated antenna. Equipment Under Test Power Configuration Rated Voltage Rated Current Rated Frequency Number of Phases 3V Lithium Battery N/A N/A N/A Operating modes of the EUT: No. Descriptions of EUT Exercising 1 During testing, the 137.5-141 kHz transmitter was operating as near to continuously as possible. A modulated carrier was used. Intertek Report Number: 100961088BOX-008 Issued: 11/28/2012 Emissions Report for Timex Group USA Inc on the M010 Page 4 of 34 5 System Setup and Method Cables ID Description Length (m) Shielding Ferrites Termination None Support Equipment Description Manufacturer Model Number Serial Number None 5.1 Method: Configuration as required by ANSI C63.4-2009. 5.2 EUT Block Diagram: Intertek Report Number: 100961088BOX-008 Issued: 11/28/2012 Emissions Report for Timex Group USA Inc on the M010 Page 5 of 34 6 Fundamental Frequency Radiated Emissions 6.1 Method Tests are performed in accordance with FCC Part 15:2012 Subpart C 15.209(a) IC RSS-210 Issue 8 December 2010 and IC RSS-Gen Issue 3 December 2010 Section 7.2.5 Table 6, and ANSI C63.4-2009. TEST SITE: 10m ALSE The 10m ALSE is 13m (Length) x 21m (Depth) x 10m (Height) with the effective size in terms of space from the tips of the absorber is 12m (Length) x 20m (Depth) x 8.5m (Height). This chamber achieves broadband performance using a unique arrangement of hybrid and ferrite tile absorber. This chamber has a built in 3m diameter turntable (Embedded type). The metal structure of the table makes electrical connection around the entire circumference of the turntable to the ground plane with a metal brush type connection. The turntable is located on one end of the chamber and the antennas are mounted 3 and 10 meters away at the other end of the chamber on the adjustable an Antenna Mast. The antenna m…

Text truncated - open the document above for the full version.

Test Setup Photos

Fundamental Test Setup Photos, Orthogonal # 1 Fundamental Test Setup Photo, Orthogonal # 2 Fundamental Test Setup Photo, Orthogonal # 3

Contact Information

Applicant

Sam Everett(Quality Regulatory Engineer)
[email protected](203) 346-5603Fax: (203) 346-7136

Technical Contact

Timex Group USA Inc.Ron Derosa
[email protected]203.346.4333

555 Christian Road · Middlebury, Connecticut · United States

Test Firm

Intertek Testing Services NA Inc.Yaqing Liu
[email protected]978 635 8662

Technical Specifications

#Rule PartsFrequency RangePower OutputEmission
115C0.1375 MHz - 0.141 MHz-26K0F1D
Confidentiality
Long Term

Other Applications from Timex Group USA, Inc.

modular - FCC ID EP9-TMXM05L - Timex Group USA, Inc.
EP9-TMXM05L

modular

Jan 30, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
modular - FCC ID EP9-TMXM05J - Timex Group USA, Inc.
EP9-TMXM05J

modular

Jan 30, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Timex Metropolitan+ - FCC ID EP9-TMXM372 - Timex Group USA, Inc.
EP9-TMXM372

Timex Metropolitan+

Sep 18, 2015

Equipment Class

DTS - Digital Transmission System
M053 - Ironman Classic 50 Move+ - FCC ID EP9-TMXM053 - Timex Group USA, Inc.
EP9-TMXM053

M053 - Ironman Classic 50 Move+

Feb 18, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
M049 - Ironman Classic 50 Move+ - FCC ID EP9-TMXM049 - Timex Group USA, Inc.
EP9-TMXM049

M049 - Ironman Classic 50 Move+

Feb 18, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter