Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
VINDSTYRKA 1x 1 Min. 10 cm (Min. 4") STARKVINDSTARKVIND 3 sec 3 sec 3 sec DIRIGERAVINDSTYRKA English 10 Français 26 Español 42 10English Instructions for use Freestanding or paired VINDSTYRKA air quality sensor can be used freestanding, but also be connected to STARKVIND air purifiers and/or DIRIGERA hub for smart products. Connect VINDSTYRKA to STARKVIND air purifier Long press the pairing buttons on VINDSTYRKA and STARKVIND at the same time to connect them. See pages 6-7. When the connection is successful, the pairing icon should stop blinking on the display. Pairing button Mode button 11 Recommended power supply: 5.0 VDC, 1.0 A (Not included) Connect VINDSTYRKA to DIRIGERA hub By connecting VINDSTYRKA to DIRIGERA hub, you'll be able to see the room’s air quality in the IKEA Home smart app. If you have an iOS device: Go to the App Store and download the IKEA Home smart app. The app will show you how to connect VINDSTYRKA to DIRIGERA hub. If you have an Android device: Go to Google Play and download the IKEA Home smart app. The app will show you how to connect VINDSTYRKA to DIRIGERA hub. 12 Pairing: Connecting VINDSTYRKA air quality sensor to DIRIGERA hub and STARKVIND air purifier. • When the pairing mode is activated, the pairing icon on the display should blink until VINDSTYRKA is connected to the air purifier or the hub. • When VINDSTYRKA is connected to 1 air purifier, the following icon should be active on the display. • When VINDSTYRKA is connected to more than 1 air purifier, the following icon should be active on the display. • When VINDSTYRKA is connected to DIRIGERA hub, only the pairing icon should be visible on the screen. 13 Display on VINDSTYRKA Shows connected air purifiers. Displays level of PM2.5 particles. PM2.5 are small inhalable particles, particles with a max. size of 2.5 micrometres. Green: 0-35 μg/m 3 , Yellow: 35-120 μg/m 3 , Red: >120 μg/m 3 . Room temperature Room relative humidity Temperature and humidity can affect the indoor comfort and wellbeing. 14 Indicates increasing, stable or decreasing level of TVOC. TVOC stands for “Total Volatile Organic Compounds” (VOC). Settings mode A long press on the mode button will enter the Settings mode. Brightness A flashing symbol means that it is possible to adjust the brightness level. Press the mode button to select between level 1, 2, and 3. A long press on the mode button confirms 15 the setting and takes you to the settings for temperature. Auto off: After 1 minute, the display brightness will return to its default setting (level 2). Temperature unit A flashing symbol means that it is possible to adjust the temperature. Press the mode button to switch between Celsius and Fahrenheit. A long press on the mode button confirms the setting and takes you back to the Settings mode. 16 Important! • The product is only intended for household use under normal operating conditions. • Do not block the air intakes and outlet in the rear. • Do not leave the product in direct sunlight or near any heat source, as it may overheat. • The wall socket must be located near the equipment and must be easily accessible. • Do not subject the product to wet, moist or excessively dusty environments since this can cause damage to the unit. • Children should be supervised to ensure they do not play with the product. • The product does not measure carbon monoxide (CO) or radon (Rn). It cannot be used as a safety 17 device upon accidents involving combustion processes and hazardous chemicals. • Be sure to not exceed the maximum USB cable length recommended for the device. • Never use a damage or faulty USB cable, since this can damage or harm the power adapter or your product. • Unplug the product from the power source before cleaning and when it is not in use. Save these instructions for future use. Factory reset Quick-press the pairing button 4 times to perform a factory reset. 18 Care instructions Wipe with a soft cloth moistened with a little mild detergent. Use another soft, dry cloth to wipe dry. Note! Never use abrasive cleaners or chemical solvents as this can damage the product. Product servicing Do not attempt to repair this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risks. 19 Technical data Model: VINDSTYRKA air quality sensor Type: E2112 Input: 5.0 VDC, 1.0 A, 0.5 W, USB-C Particle detection range: 0~1000 μg/m 3 Radio range: 10 m in open air Operating frequency: 2400~2483.5 MHz Output power: 8 dBm Operation temperature: 0°C to 40°C Operating humidity: 0 to 95% RH Max USB cable length: 3.0 m/9’8” Indoor use only 20 Manufacturer: IKEA of Sweden AB Adress: Box 702, SE-343 81 Älmhult, SWEDEN This device complies with Part 15 of the FCC Rules. This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation Science and Economic Development Canada's licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference 21 received, including interference that may cause undesired operation of the device. WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 22 This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the quipment …
Text truncated - open the document above for the full version.
© Inter IKEA Systems B.V. 2014 Oct 20 th , 2022 Federal Communications Commission 445 12 th Street SW Washington, DC 20554 Subject: Limited Agency Agreement IKEA of Sweden AB FCC ID: FHO-E2112 To Whom It May Concern: We, IKEA of Sweden AB, hereby authorized Intertek Semko AB, Sweden to act as our Agent for the purpose of preparing application for FCC ID number FHO- E2112 under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is October 20, 2022. The Limited Agency Agreement expires on March 31 st , 2023, unless sooner terminated or extended by written notice to Intertek Semko AB and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of f ederal benefits pursuant to Section 5301 of t he Anti -Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of f ederal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, I van Susak Team Manager, Laws&Standards IKEA of Sweden AB [email protected] +4647681000
Internal Internal Internal TYPE: E2112 VINDSTYRKA air quality sensor IKEA of Sweden AB SE-343 81 Älmhult Input: 5.0V 0.2A VINDSTYRKA air sensor NA USB Type C - Remark: The font isand all size tolerances should be within ±0.5mm.NotoIKEALatin 5016928 5496mm.*. 5016928 6*4.4mm Made in China 50050 Indoor use only yyww FCC ID:FHO-E2112 IC:10912A-E2112 Conforms & Cert. to A/V ICTE Contains IC:5123A-MGM210L Contains FCC ID:QOQMGM210L
TYPE: E2112 VINDSTYRKA air quality sensor IKEA of Sweden AB SE-343 81 Älmhult Input: 5.0V 0.2A VINDSTYRKA air sensor NA USB Type C - Remark: The font isand all size tolerances should be within ±0.5mm.NotoIKEALatin 5016928 5496mm.*. 5016928 6*4.4mm Made in China 50050 Indoor use only yyww FCC ID:FHO-E2112 IC:10912A-E2112 Conforms & Cert. to A/V ICTE Contains IC:5123A-MGM210L Contains FCC ID:QOQMGM210L
Internal Internal Internal TYPE: E2112 VINDSTYRKA air quality sensor IKEA of Sweden AB SE-343 81 Älmhult Input: 5.0V 0.2A VINDSTYRKA air sensor NA USB Type C - Remark: The font isand all size tolerances should be within ±0.5mm.NotoIKEALatin 5016928 5496mm.*. 5016928 6*4.4mm Made in China 50050 Indoor use only yyww FCC ID:FHO-E2112 IC:10912A-E2112 Conforms & Cert. to A/V ICTE Contains IC:5123A-MGM210L Contains FCC ID:QOQMGM210L
Test report no. 2209805STO-102 Annex 1 Page 1 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se ANNEX 1 Test report no. Release no. Date of issue Description 2101144STO-102 Annex 1 1 May 11, 2022 2209805STO-101 2 November 10, 2022 Uptade of report 2101144STO-102 Annex 1 with photos for FCC part 15 B above 1 GHz and photos of PCB. Photos of EUT EUT Test report no. 2209805STO-102 Annex 1 Page 2 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Photos of test setup Test setup for conducted emission 150 kHz – 30 MHz Test set up radiated emission 30 MHz – 1 GHz Test report no. 2209805STO-102 Annex 1 Page 3 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Test set up radiated emission 1 GHz – 12.5 GHz Test report no. 2209805STO-102 Annex 1 Page 4 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Photos of EUT interior Test report no. 2209805STO-102 Annex 1 Page 5 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se
Test report No. 2209805STO-101 Page 2 (21) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Version 2.05 Revision History Test report no. Release no. Date of issue Description 2101144STO-102 1 May 11, 2022 2209805STO-101 2 November 15, 2022 Updated of report 2101144STO-102 with measurements for FCC part 15 B above 1 GHz. Correction values added to all result tables. Test report No. 2209805STO-101 Page 3 (21) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Version 2.05 Terms, definitions and abbreviations The following terms, definitions and abbreviations may be used throughout the report. Term/definition/abbreviation Meaning AAN Asymmetrical Artificial Network AC Alternating Current AE Associated Equipment AMN Artificial Mains Network ANSI American National Standards Institute AV Average BW Bandwidth CAV CISPR Average CFR Code of Federal Regulations CISPR Comité international spécial des perbutations radioélectriques CM Common Mode CMAD Common Mode Absorption Device DC Direct Current DM Differential Mode EM Electromagnetic EMC Electromagnetic Compatibility EUT Equipment Under Test F Fail FAR Fully Anechoic Room FCC Federal Communications Commission 푭 푿 Highest fundamental frequency generated or used within the EUT, or highest frequency at which it operates ICES Interference-Causing Equipment Standard H Horizontal I ref Reference Current ISN Impedance Stabilizing Network MU Measurement Uncertainty N/A Not Applicable P Pass PE Protective Earth PK Peak Pol. Polarisation QP / QPK Quasi-Peak RBW Resolution Bandwidth RF Radio Frequency RGP Reference Ground Plane RH Relative Humidity RMS Root Mean Square Rx Receiver / Receiving SAC Semi-Anechoic Chamber Tx Transmitter / Transmitting V Vertical VBW Video Bandwidth Test report No. 2209805STO-101 Page 4 (21) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Version 2.05 CONTENTS Page 1. Client Information ............................................................................................................... 5 2. Equipment under test (EUT) ............................................................................................... 5 2.1 Identification of the EUT ........................................................................................... 5 2.2 Additional information about the EUT ...................................................................... 7 2.3 Peripheral/auxiliary equipment ................................................................................. 8 2.4 Decision rule ............................................................................................................ 8 3. Test Specifications ............................................................................................................. 9 3.1 Additions, deviations and exclusions from standards and accreditation ................. 9 3.2 Test site .................................................................................................................... 9 3.3 Mode of operation during the test .......................................................................... 10 4. Test Summary .................................................................................................................. 11 5. Conducted continuous disturbances ................................................................................ 12 5.1 Test results, Conducted continuous disturbances, AC Power input port, Class B 14 5.2 Test equipment ...................................................................................................... 15 6. Radiated rf Emission in the frequency-range 30 MHz – 1 GHz ....................................... 16 6.1 Test results, 30 – 1000 MHz, FCC, Class B .......................................................... 18 6.2 Test results, 30 – 1000 MHz, ICES-001, Group 1, Class B ................................... 19 6.3 Test equipment ...................................................................................................... 21 Test report No. 2209805STO-101 Page 5 (21) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Version 2.05 1. CLIENT INFORMATION The EUT has been tested by request of Company IKEA of Sweden AB SE‐343 81 Älmhult Sweden Name of contact Jeton Salihu Client observer - 2. EQUIPMENT UNDER TEST (EUT) 2.1 Identification of the EUT Equipment: Environmental sensor Type/Model: E2112 Vindstyrka air quality sensor Brand name: IKEA S/N: 50050 Manufacturer: IKEA of Sweden AB Highest clock frequency, 퐹 푋 : 80 MHz Transmitting freq.: 2400–2483.5 MHz Software version: 1.0.005-532 Hardware version: P1.2.1 Mounting position: (during normal use) ☒ Table-top ☐ Floor-standing ☐ Wall/ceiling ☐ Hand-held ☐ Other: Supplementary information: Input ratings Voltage [V] Freq. [Hz] Current [A] Power [W] Coupling ☐ AC - - - - L1 L2 L3 N PE ☐ ☐ ☐ ☐ ☐ ☒ DC 5 - 0.2 - V+ V- PE ☒ ☒ ☐ ☐ Battery V+ V- PE ☐ ☐ ☐ ☐ Other: Test report No. 2209805STO-101 Page 6 (21) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Version 2.05 Test set up and EUT photos are enclosed in Annex 1 (2209805STO-102) to this test report. Photo/copy of marking/rating plate Test report No. 2209805STO-101 Page 7 (21) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Version 2.05 2.2 Additional information about the EUT The EUT is an environmental sensor for both indoor and outdoor values such as temperature, humidity, PM2.5, VOC and Pollen. The outdoor values will be imported from an external source. The sensor can optionally be paired to the IKEA Gateway or to the air purifier STARKVIND. The EUT consists of the following units: Unit Type/model Description Air quality sensor E2112 - The EUT has the following ports: Port type Port name Shielded AC I/O ☐ AC power input ☐ ☐ AC power output ☐ DC I/O ☒ DC power input DC input ☐ ☐ DC …
Text truncated - open the document above for the full version.
Test report no. 2209805STO-102 Annex 1 Page 1 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se ANNEX 1 Test report no. Release no. Date of issue Description 2101144STO-102 Annex 1 1 May 11, 2022 2209805STO-101 2 November 10, 2022 Uptade of report 2101144STO-102 Annex 1 with photos for FCC part 15 B above 1 GHz and photos of PCB. Photos of EUT EUT Test report no. 2209805STO-102 Annex 1 Page 2 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Photos of test setup Test setup for conducted emission 150 kHz – 30 MHz Test set up radiated emission 30 MHz – 1 GHz Test report no. 2209805STO-102 Annex 1 Page 3 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Test set up radiated emission 1 GHz – 12.5 GHz Test report no. 2209805STO-102 Annex 1 Page 4 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se Photos of EUT interior Test report no. 2209805STO-102 Annex 1 Page 5 (5) Intertek Semko AB Torshamnsgatan 43, Box 1103, SE-164 22 Kista, Sweden www.intertek.se
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |
Door window sensor
Equipment Class
JAB - Part 15 Class B Digital DeviceLED lamp
Equipment Class
JAV - Other Non-Digital SDoC DevicesLED lamp
Equipment Class
JAV - Other Non-Digital SDoC DevicesRemote Control (Scroll Wheel)
Equipment Class
JAB - Part 15 Class B Digital Device