
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
47.5mm 3.5mm
SGS-CSTC Standards Technical Services Co., Ltd. No.198 Kezhu Road, Science Town Economic& Technology Development District Guangzhou, China 510663 Telephone: +86 (0) 20 8215 5555 Fax: +86 (0) 20 8207 5059 Email: [email protected] Report No.: SZEMO060400784AVB Page: 1 of 8 FCC ID: G95RS2100B Robinson Lo Laboratory Manager This report refers to the General Conditions for Inspection and Testing Services, printed overleaf. This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the SGS PRODUCT CERTIFICATION MARK. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical Approvals in writing. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. All test results in this report can be traceable to National or International Standards. Member of the SGS Group (SGS SA) FCC Part15B Test Report Application No.: SZEMO060400784AV Applicant: FCC ID: Thomson Industry (Shenzhen) Co., Ltd. G95RS2100B Equipment Under Test (EUT): EUT Name: audio system with 2.4G wireless* Item No.: RS2100 * This report is only about the USB dungle of the audio system with 2.4G wireless. Standards: FCC PART15 SUBPART B:2006 Date of Receipt: 25 April 2006 Date of Test: 26 April to 24 June 2006 Date of Issue: 25 June 2006 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Report No.: SZEMO060400784AVB Page: 2 of 8 FCC ID: G95RS2100B 2 Test Summary Test Test Requirement Test Method Class / Severity Result Radiated Emission (30MHz to 1GHz) FCC PART 15, SUBPART B: 2006 ANSI C63.4:2003 Class B PASS Conducted Emission (150KHz to 30MHz) FCC PART 15, SUBPART B: 2006 ANSI C63.4:2003 Class B PASS The test result is only about the USB dungle of the audio system with 2.4G wireless. SGS-CSTC Standards Technical Services Co., Ltd. Report No.: SZEMO060400784AVB Page: 3 of 8 FCC ID: G95RS2100B 3 Contents Page 1 COVER PAGE............................................................................................................................................1 2 TEST SUMMARY....................................................................................................................................................2 3 CONTENTS..............................................................................................................................................................3 4 GENERAL INFORMATION....................................................................................................................................4 4.1 CLIENT INFORMATION.......................................................................................................................................4 4.2 GENERAL DESCRIPTION OF E.U.T...................................................................................................................4 4.3 DETAILS OF E.U.T............................................................................................................................................4 4.4 DESCRIPTION OF SUPPORT UNITS...................................................................................................................4 4.5 STANDARDS APPLICABLE FOR TESTING...........................................................................................................4 4.6 TEST LOCATION................................................................................................................................................4 4.7 TEST FACILITY..................................................................................................................................................5 4.8 DEVIATION FROM STANDARDS..........................................................................................................................5 4.9 ABNORMALITIES FROM STANDARD CONDITIONS..............................................................................................5 5 EQUIPMENTS USED DURING TEST..................................................................................................................6 6 TEST RESULTS......................................................................................................................................................7 6.1 CONDUCTED EMISSIONS MAINS TERMINALS, 150KHZ TO 30MHZ.................................................................7 6.1.1 E.U.T. Operation........................................................................................................................................7 6.1.2 Measurement Data....................................................................................................................................7 6.2 RADIATED EMISSIONS, 30MHZ TO 1GHZ........................................................................................................8 6.2.1 E.U.T. Operation........................................................................................................................................8 6.2.2 Measurement Data....................................................................................................................................8 SGS-CSTC Standards Technical Services Co., Ltd. Report No.: …
Text truncated - open the document above for the full version.
Conducted Emission Test Setup Radiated Emission Test Setup
198 KEZHU Road, SCIENTECH Park · Guangzhou, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

Wi-Fi 7 XGS-PON Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX
DOCSIS 3.1
Equipment Class
NII - Unlicensed National Information Infrastructure TXWi-Fi 6E Extender
Equipment Class
6PP - 15E 6 GHz Subordinate Indoor Device
Wireless Access Point
Equipment Class
DTS - Digital Transmission System
DOCSIS 3.1 Residential Voice Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX