FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Rosslare Enterprises Ltd/
  3. GCD-AYK35

GCD-AYK35Multi-Smart Readers

Rosslare Enterprises Ltd
Multi-Smart Readers - FCC ID GCD-AYK35 - Rosslare Enterprises Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 01, 2021
Application Purpose
Original Equipment
Date of Application
Aug 01, 2021
Equipment Note
Multi-Smart Readers
Frequency Range
2402.00000000 - 2480.00000000
Company
Rosslare Enterprises Ltd
Country
Hong Kong

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Des cription Qua ntity Sel f-adhesivemounting labeltemplate 1 Fla tscrewM3.5 x25 mm 2 Pla sticanchorM6 x30 mm 2 Torxtamperproofscrewdriver1 TorxscrewM3 x5 mm1 2. Technical Specifications ElectricalCharacteristics PowerSupply TypeRegulated Operating VoltageRange8 to 16 VDC Current@ 12 VStandby:110 mA,max:185 mA @ 12 VDC Blu etooth BLE Read Range Fro m 1 m to 12 m (3.2 to 39.3 ft)(lineofsight) RFIDand NFC Read Range* ISO 14443A –MIFARE®Classic®EV1:SectorRead Contactless13.56 MHz:Up to 7 cm (2.75 in.) Contactless125 kHz:up to 8 cm (3.15 in.) Multi- Smart™ Rea ders 125 kHz, 13.56 MHz, Bluetooth® and NFC 1. Int roduction The innovative Multi-Smart™ Readers from Rosslare support multiple technologies: BLE (Bluetooth Low Energy), 13.56 MHz RFID. Multi-technology Multi-Smart™ Readers are especially suited for sites that need more than one RFID credential or use more than one CSN Select credential. The readers supports ASK and FSK for 125 kHz and 13.56 MHz smartcards to read the RFID transponder UID and output the ID to the control panel. This feature supports all RFID types in one reader without updating legacy credentials in the system. Multi-Smart™ Readers read NFC-ID™ and BLE-ID™ credentials, and issue BLE-ID credentials (iOS and Android) to smartphone users. The BLE-Admin™ app can configure which technologies are used by each reader. The readers support SIA Open Supervised Device Protocol (OSDP V2) including SCP mode (Secured Channel Protocol), allowing readers to connect to any controller that supports OSDP. The readers also have a capacitive touch button on the surface which can be assigned functions such as Door Bell, Exit, Help, Lights or other required outputs. With simple installation, the readers allow you to easily manage add-ons installations and technology migrations. They come in a modern small model that fit any architecture design, and are suitable for outdoor use. In addition, they are CE and FCC certified. 1.1. Installation Kit The installation kit consists of the following items to be used during the installation procedure. www.rosslaresecurity.com 1 DRAFT ElectricalCharacteristics LED/BuzzerControlsDryContact,N.O. TamperOutput Opencollector,activelow,max.sinkcurrent20mA@12VDC,10mA@5 VDC.Current limit:500 Ωseriesresistance MaximumCableDistanceto Controller Wiegand:150m(500ft)with18-AWGcable OSDP(RS-485):1,200m(4,000ft)with2x218AWGtwistedshieldedcable EnvironmentalCharacteristics OperatingTemp.Range-35°Cto66°C(-31°Fto150°F) OperatingHumidityRange0to95%(non-condensing) OperatingEnvironment Weather-resistant,UV-resistant,meets IP65 ,epoxy-potted,suitableforindoorand outdooruse VandalResistance IK? PhysicalCharacteristics Dimensions (HxWxD) Weight *Readrangelistedisstatisticalmeanroundedtonearestcentimeter,measuredinopenairusingRosslareMIFAREClassicEV1(ISOcard).Formfactor,technologyand environmentalconditions,includingmetallicmountingsurface,candegradereadrangeperformance;plasticspacersarerecommendedtoimproveperformanceonmetallic mountingsurfaces. 3.Installation 3.1.MountingtheMulti-Smart™Readers Whenselectinganareaformounting,ensurethelocationisflat. ToMountMulti-Smart™Readers: 1.Drill2holesinthewall,usingthemountingtemplateprovidedintheinstallation. 2.Insert2anchorsprovidedintothedrilledholes. 3.Mountthebracketonthewallusingthe2screwsprovided. Multi-Smart™ReadersInstallation&UserGuide www.rosslaresecurity.com 2 88 x 48 x 24 mm (3.5 x 1.9 x 0.9 in.) 190 g (6.7 oz) 4.MountthereaderonthebracketandfastenatbottomwithTorxscrewandTorxscrewdriverprovided. 3.2.WiringtheMulti-Smart™Readers ToWireMulti-Smart™Readers: Unitsaresuppliedwitha11 conductor56 cm(22 in.)pigtailwithexposedwirescoatedwithsolder. • TheindividualwiresfromthereaderarecolorcodedaccordingtheWiegandstandard. • Whenusingaseparatepowersupplyforthereader,thissupplyandthatofthecontrollermusthavea commonground. • Thereader’scableshieldwireshouldbepreferablyattachedtoanearthground,orasignalground connectionatthepanel,orpowersupplyendofthecable. ToConnectTheReaderToTheController: 1.Selecttheappropriateconnectionsaccordingtothetablebelow. 2.Preparethecontrollercablebycuttingitsjacketbackabout3cm(1¼in.)andstriptheinsulationfromthewires about1.3cm(½in.). 3.Splicethereader’spigtailwirestothecorrespondingcontrollerwiresandcovereachjointwithinsulatingtape. 4.Ifthetamperoutputisbeingutilized,connectthepurplewiretothecorrectinputonthecontroller. 5.Trimandinsulatetheendsofallunusedconductorsindividually.Donotshortanyunusedwirestogether. Multi-Smart™ReadersInstallation&UserGuide www.rosslaresecurity.com 3 WireColorFunction RedPower BlackGround GreenData0/Data WhiteData1/Clock OrangeGreenLEDControl BrownRedLEDControl PurpleTamperOutput YellowBuzzerControl BlueRS-485-A/OSDP GrayRS-485-B/OSDP Black(shrink)Shield 4.Configuration TheBLE-IDapplicationallowsamobiledevicetobeusedasacredential.Downloadtheapplicationfrom GooglePlayorAppStoreusingthefollowingQRcode. 1.DownloadtheRosslareBLE-AdminapplicationfromGooglePlayorAppStore. 2.Opentheapplication,selecttherequiredreaderfromthelistdisplayed. 3.Enterthepassword. • Usethedefaultpassword(12345678)whenyoulogintotheBLE-Adminapplicationforthefirst time. • Itishighlyrecommendedthatyouchangethepassword(seestep4). Multi-Smart™ReadersInstallation&UserGuide www.rosslaresecurity.com 4 4.Onthemainscreen,configurethefollowing: OptionRemarks DoorNameAssignnametoselecteddoorreader PasswordChangepassword FirmwareAllowsfirmwareupdateoverBLEfromalistofavailableversions. Asmallnumberofminutesisnecessarytoupdatethefirmware.Duringthistime,themobiledatalink mustbestable.Iftheupdateprocedurefails,thereaderwillcontinuetooperatewiththeinitial firmware. 5.TapSetConfigurationandconfigurethefollowing: ParameterOptionsRemarks ProtocolWiegand26bit,OSDP,OSDP-SC,ClockandData Wiegand:26/26R,32/32R,34/34R, 40/40R,56,56R,64/64Rbit 26bit(default) OSDP-SC:Installmode(read/write) OSDPaddresses:0-31 13(default) SectorOff,KeyA.xxxxxx Off(default) KeyA:Musttype12characterkeyinHex format Location: •Sector[0-39] •Block[0-14] •Byte[0-15]…

Text truncated - open the document above for the full version.

Cover Letter(s)

QA-FR-171-A Ro sslare Enterprises Ltd ADD: Room 905,12 Wang Tai Road , Kowloon Bay, Kowloon, Hong Kong TEL: 847-827-6330 FAX: 847-827-6433 E-mail: [email protected] FCC Confidential Authorization Date: 2021-06-17 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: GCD-AYK35 In accordance with Sections 0.457 and 0.459 of the Commission’s Rules, Rosslare Enterprises Ltd . hereby requests long-term confidential treatment of information accompanying this application as outlined below: ď‚·Block Diagram ď‚·Schematics ď‚·Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature: Printed Name: Joe LeKostaj Title: Engineering Manager

External Photos

EXHIBIT B - EUT EXTERNAL PHOTOGRAPHS

ID Label/Location Info

Label and locat Label tion

Internal Photos

EXHIBIT C - EUT INTERNAL PHOTOGRAPHS RFID Antenna Board Chip BLE Antenna

Test Report

FCC PART 15.247 TEST REPORT For Rosslare Enterprises Ltd Room 905,12 Wang Tai Road, Kowloon Bay, Kowloon, Hong Kong Report Type: Original Report Product Name: Multi-Smart™Readers Re port Number: DG2210429-14679E-00A Re port Date: 2021-06-04 Reviewed By: Ivan Cao Assistant Manager Test Laboratory: Bay Area Compliance Laboratories Corp. (Dongguan) No.12, Pulong East 1 st Road, Tangxia Town, Dongguan, Guangdong, China Tel: +86-769-86858888 Fax: +86-769-86858891 www.baclcorp.com.cn FCC ID: GCD-AYK35 Bay Area Compliance Laboratories Corp. (Dongguan) Report No.: DG2210429-14679E-00A Page 2 of 40 TABLE OF CONTENTS GENERAL INFORMATION ....................................................................................................................................... 4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ..................................................................................... 4 OBJECTIVE ................................................................................................................................................................... 4 RELATED SUBMITTAL(S)/GRANT(S) ............................................................................................................................. 4 TEST METHODOLOGY .................................................................................................................................................. 4 MEASUREMENT UNCERTAINTY .................................................................................................................................... 5 TEST FACILITY ............................................................................................................................................................. 5 DECLARATIONS ............................................................................................................................................................ 5 SYSTEM TEST CONFIGURATION .......................................................................................................................... 6 DESCRIPTION OF TEST CONFIGURATION ...................................................................................................................... 6 EQUIPMENT MODIFICATIONS ....................................................................................................................................... 6 EUT EXERCISE SOFTWARE .......................................................................................................................................... 6 SUPPORT EQUIPMENT LIST AND DETAILS .................................................................................................................... 8 SUPPORT CABLE LIST AND DETAILS ............................................................................................................................ 8 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................ 8 SUMMARY OF TEST RESULTS ............................................................................................................................... 9 FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) ....................................... 10 APPLICABLE STANDARD ............................................................................................................................................ 10 FCC §15.203 - ANTENNA REQUIREMENT ........................................................................................................... 11 APPLICABLE STANDARD ............................................................................................................................................ 11 ANTENNA CONNECTOR CONSTRUCTION .................................................................................................................... 11 FCC §15.207 (a) – AC LINE CONDUCTED EMISSIONS ..................................................................................... 12 APPLICABLE STANDARD ............................................................................................................................................ 12 EUT SETUP ................................................................................................................................................................ 12 EMI TEST RECEIVER SETUP ....................................................................................................................................... 12 TEST PROCEDURE ...................................................................................................................................................... 13 CORRECTED AMPLITUDE & MARGIN CALCULATION ................................................................................................. 13 TEST EQUIPMENT LIST AND DETAILS ......................................................................................................................... 13 TEST DATA ................................................................................................................................................................ 14 FCC §15.209, §15.205 & §15.247(d) - SPURIOUS EMISSIONS ............................................................................. 16 APPLICABLE STANDARD ............................................................................................................................................ 16 EUT SETUP ................................................................................................................................................................ 16 EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP .............................................................................................. 17 TEST PROCEDURE ...................................................................................................................................................... 17 CORRECTED AMPLITUDE & MAR…

Text truncated - open the document above for the full version.

Test Setup Photos

EXHIBIT D - TEST SETUP PHOTOGRAPHS Conducted Emission Front View Conducted Emission Side View Radiated Emission Below 1GHz View Radiated Emission Above 1GHz View

Contact Information

Applicant

Ilan Ozer(Director)
[email protected]+852-2795-5630Fax: +852-2795-1508

Test Firm

Bay Area Compliance Laboratories Corp.(Dongguan)David Zhang
[email protected]0086 0769 86858888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.

Other Applications from Rosslare Enterprises Ltd

Advanced Wireless Security Panels - FCC ID GCD-HLX24TH - Rosslare Enterprises Ltd
GCD-HLX24TH

Advanced Wireless Security Panels

Jan 27, 2016

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Advanced Wireless Security Panels - FCC ID GCD-HLX24TG - Rosslare Enterprises Ltd
GCD-HLX24TG

Advanced Wireless Security Panels

Jan 27, 2016

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Reader - FCC ID GCDAYXX0 - Rosslare Enterprises Ltd
GCDAYXX0

Reader

Sep 20, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Reader - FCC ID GCDAYQX0 - Rosslare Enterprises Ltd
GCDAYQX0

Reader

Sep 20, 2015

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Wireless Security Panel - FCC ID GCD-HLX24G - Rosslare Enterprises Ltd
GCD-HLX24G

Wireless Security Panel

Apr 28, 2015

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver