Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Agent letter FCC attestation statement Kiwa Page 1 of 2 RF_753, Issue 2 20-11-2023 U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company name: Climax Int'I Corp. FRN: 0033602137 Contact person name: George Lin (& Shirley Wang) Street address: 5661 Palmer Way, Ste K ZIP/City/State Carlsbad, CA 92010 Telephone number: 760-476-1978 Email address: [email protected] [email protected] Signature: Date: 2025-06-04 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Climax Technology Co Ltd Grantee Code: GX9 Contact person name: George Lin Street address: No. 258, Sinhu 2nd Rd., Neihu District ZIP/City/State Taipei City 114 Telephone number: 886-2-2794-0001 Email address: [email protected] Signature: Date: 2025-06-04
Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_03 06-06-2024 Certification Application Attestation Statements < CLIMAX TECHNOLOGY CO., LTD.> <FRN: 0021168695> < No. 258, Sinhu 2nd Rd., Neihu District,> <114> <Taipei City> <Taiwan ( R.O.C.)> Subject: FCC ID: <GX9BX29F1919> To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) 1. [CLIMAX TECHNOLOGY CO., LTD.] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. 2. [CLIMAX TECHNOLOGY CO., LTD.] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [CLIMAX TECHNOLOGY CO., LTD.] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2025/12/22 City: Taipei City 114, Name(2) : George Lin Function: Hardware Engineer Telephone number: 886-2-2794-0001 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_03 06-06-2024 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvM 02 1 15-02-2023 Changed Applicant to Company and added “Subject: FCC ID: “ RvdM 03 1 06-06-2024 FRN added at certification application and included [ Insert Company Name Here] for the statements RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 03 Date : 06-06-2024 Verified by : Willem Jan Jong Function : Team Lead Date : 06-06-2024 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 06-06-2024
RF_160_06 Declaration of Authorisation Date of issue 13-08-2025 Declaration of Authorization We Name: CLIMAX TECHNOLOGY CO., LTD. Address: No. 258, Sinhu 2nd Rd., Neihu District, City: Taipei City 114, Country: Taiwan ( R.O.C.) Declare that: Name Representative of agent: Penny Lin (1) Agent Company name: Worldwide Testing Services (Taiwan) Co., Ltd. Address: 6F., No. 58, Ln. 188, Ruey-Kuang Rd., Neihu, City: Taipei City, Country Taiwan (R.O.C.) is authorized to apply for Certification of the following product(s): Product description: Outdoor Bell Box Type designation: BX-29 Trademark: NA Validity/ expiry date on our behalf. Date: 2025/12/22 City: Taipei City Name: George Lin (2) Function: Hardware Engineer Signature: ............................... Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent. Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 05 1 02-01-2023 History sheet added AG 06 all 13-08-2025 Kiwa logo change AG Issued/modified by : Axel Gase Function : Manager Quality Assurance Revision : 06 Date : 13-08-2025 Verified by : Willem Jan Jong Function : Team Lead Date : 13-08-2025 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 13-08-2025
FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 1 of 2 Company Name: CLIMAX TECHNOLOGY CO., LTD. Address: No. 258, Sinhu 2nd Rd., Neihu District, City: Taipei City 114, Country: Taiwan ( R.O.C.) To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: GX9BX29F1919 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Business considerations Date: 2025/12/22 Name and signature of applicant: George Lin Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 2 of 2 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 10 1 02-01-2023 History sheet added AG 11 1 & 2 23-06-2023 Corrected date and page# WJJ 12 all 18-08-2025 Kiwa logo change AG Issued/modified by : Axel Gase Function : Manager Quality Assurance Revision : 12 Date : 18-08-2025 Verified by : Willem Jan Jong Function : Team Lead Date : 18-08-2025 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 18-08-2025
Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 21 External Photos Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 21 Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 21 Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 21 Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 21 Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 21
Model: BX-29 FCC ID. : GX9BX29F1919 THIS DEVICE COMPLIES WITH PART 15 OF THE FCCRULES. OPERATIONS IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: ( 1 ) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE ( 2 ) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFEERENCE THAT MAY UNDESIRED OPERATION . On the back
of Applicant: CLIMAX TECHNOLOGY CO., LTD. Address: No. 258, Sinhu 2nd Rd., Neihu District, Taipei City 114, Taiwan ( R.O.C.) Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22512-24857-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC RF Exposure Exemption report for Outdoor Bell Box Model No.: BX-29 FCC ID: GX9BX29F1919 Registration number: W6M22512-24857-EE FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 7 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 2 1.3 A PPLICATION DETAILS ................................................................................................................. 3 1.4 G ENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.5 T EST STANDARDS ......................................................................................................................... 4 2 TEST CONFIGURATION .............................................................................................................. 5 2.1 T EST ENVIRONMENT .................................................................................................................... 5 2.2 M EASUREMENT UNCERTAINTY .................................................................................................... 5 2.3 TEST EQUIPMENT LIST ................................................................................................................. 5 3 EQUIVALENT ISOTROPIC RADIATED POWER (EIRP)....................................................... 6 3.1 EXEMPTION LIMITS FOR ROUTINE EVALUATION .......................................................................... 6 Registration number: W6M22512-24857-EE FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 7 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: December 24, 2025 Ken Kang Date WTS-Lab. Name Signature Technical responsibility for area of testing: December 24, 2025 Kevin Wang Date WTS Name Signature Registration number: W6M22512-24857-EE FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 7 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) 3 meter semi-anechoic chamber No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Application details Approval holder Name: CLIMAX TECHNOLOGY CO., LTD. Street: No. 258, Sinhu 2nd Rd., Neihu District, Town: Taipei City 114, Country: Taiwan ( R.O.C.) Manufacturer: (if applicable) Name: ./. Street: ./. Town: ./. Country: ./. Registration number: W6M22512-24857-EE FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 7 Date of receipt of test item: December 09, 2025 Date of test: from December 10, 2025 to December 23, 2025 1.4 General information of Test item Type of test item: Outdoor Bell Box Model number: BX-29 Multi-listing model number: ./. Sample no.: #01 Technical data Frequency band: 918.0375-924.48 MHz Mode Frequency (MHz) Power (dBm) 900M 918.0375 MHz 11.95 924.48 MHz 11.93 Power supply: Battery 6 Vd.c. Operation modes: Duplex Modulation type: FSK Antenna type: Monopole antenna Antenna gain: 1.83 dBi Host device: none Classification: Fixed Device Mobile Device (Human Body distance > 20cm) Portable Device (Human Body distance < 20cm) 1.5 Test standards 47 CFR FCC Part 1 Subpart I, section 1.1310 FCC KDB Publication 447498 D01 General RF Exposure Guidance v06 Registration number: W6M22512-24857-EE FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 5 of 7 2 Test configuration 2.1 Test environment Relative humidity content: 20 ... 75 % Air pressure: 8…
Text truncated - open the document above for the full version.
of Applicant: CLIMAX TECHNOLOGY CO., LTD. Address: No. 258, Sinhu 2nd Rd., Neihu District, Taipei City 114, Taiwan ( R.O.C.) Tested and Prepared By Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22512-24857-C-1 6F., No. 58, Ln. 188, Rueiguang Rd., Neihu Dist., Taipei City , Taiwan (R.O.C.) TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for Outdoor Bell Box Model No.: BX-29 FCC ID: GX9BX29F1919 Registration number: W6M22512-24857-C-1 FCC ID: GX9BX29F1919 Worldwide Testing Services (Taiwan) Co., Ltd. Page 1 of 28 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES ........................................................................................................................................................................ 2 1.2 TESTING LABORATORY .......................................................................................................................................... 3 1.2.1 Location .................................................................................................................................. 3 1.2.2 Details of accreditation status ................................................................................................ 3 1.3 DETAILS OF APPROVAL HOLDER ......................................................................................................................... 3 1.4 APPLICATION DETAILS ........................................................................................................................................... 3 1.5 GENERAL INFORMATION OF TEST ITEM ............................................................................................................. 4 1.6 TEST STANDARDS .................................................................................................................................................... 4 1.7 TEST PROCEDURE .................................................................................................................................................... 4 2 TECHNICAL TEST ......................................................................................................................... 5 2.1 SUMMARY OF TEST RESULTS ................................................................................................................................ 5 2.2 TEST ENVIRONMENT............................................................................................................................................... 5 2.3 TEST EQUIPMENT LIST .......................................................................................................................................... 6 2.4 GENERAL TEST PROCEDURE ................................................................................................................................ 7 3 TEST RESULTS (ENCLOSURE) .................................................................................................. 9 3.1 PEAK OUTPUT POWER (TRANSMITTER) ........................................................................................................... 10 3.2 TRANSMITTER RADIATED EMISSIONS IN RESTRICTED BANDS .................................................................. 12 3.3 SPURIOUS EMISSIONS (TX) .................................................................................................................................. 13 3.4 CARRIER FREQUENCY SEPARATION ................................................................................................................. 14 3.5 NUMBER OF HOPPING FREQUENCIES ............................................................................................................... 16 3.5.1 Pseudorandom Frequency Hopping Sequence .................................................................... 17 3.5.2 Coordination of hopping sequences to other transmitters .................................................... 17 3.5.3 System Receiver Hopping Capability ................................................................................... 17 3.6 TIME OF OCCUPANCY (DWELL TIME) .............................................................................................................. 18 3.7 20DB BANDWIDTH .............................................................................................................................................. 21 3.7.1 System Receiver Input Bandwidth ......................................................................................... 22 3.8 BAND-EDGE COMPLIANCE OF RF EMISSIONS ............................................................................................... 23 3.9 RADIATED EMISSIONS FROM DIGITAL PART ................................................................................................. 26 3.10 POWER LINE CONDUCTED EMISSION ............................................................................................................... 27 Registration number: W6M22512-24857-C-1 FCC ID: GX9BX29F1919 Worldwide Testing Services (Taiwan) Co., Ltd. Page 2 of 28 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and th…
Text truncated - open the document above for the full version.
Climax °≥ Antenna OTA 3D Antenna Pattern Infomation Date45709 Start Time 45709.46944 Finish Time45709.47292 Lab Name Max860 Operator ATEN Project Nu mBX-29 ManufacturPASSIVE V1.1 Model NamF1919 P7P -2 Hardware V1 Software V3.6.1 Beta Test ConditFree Space TempuraturN/A Humidity N/A Note N/A Test List 800MHz 804MHz 808MHz 812MHz 816MHz 820MHz 824MHz 828MHz 832MHz 836MHz 840MHz 844MHz 848MHz 852MHz 856MHz 860MHz 864MHz 868MHz 872MHz 876MHz 880MHz 884MHz 888MHz 892MHz 896MHz 900MHz 904MHz 908MHz 912MHz 916MHz 920MHz 924MHz 928MHz 932MHz 936MHz 940MHz 944MHz 948MHz 952MHz 956MHz 960MHz 964MHz 968MHz 972MHz 976MHz 980MHz 984MHz 988MHz 992MHz 996MHz 1GHz Frequency 800MHz 804MHz 808MHz 812MHz 816MHz 820MHz 824MHz 828MHz 832MHz 836MHz 840MHz 844MHz 848MHz 852MHz 856MHz 860MHz 864MHz 868MHz 872MHz 876 MHz 880MHz Ant. Port Inp. Pow. (dBi) 000000000000000000000 Rad. Pow. (dBi) -4.62 -4.79 -4.66 -4.61 -4.62 -4.15 -4.15 -4.36 -4.27 -4. 55 -4.51 -4.06 -3.92 -4.01 -4.01 -4.04 -3.92 -3.38 -3.28 -3.6 -3.44 Rad. Pow. 0-90 (dBi) -9.75 -9.88 -9.69 -9.61 -9.56 -9.03 -8.97 -9.11 -8. 95 -9.15 -9.09 -8.72 -8.63 -8.73 -8.75 -8.75 -8.57 -7.95 -7.75 -7.98 -7.73 Rad. Pow. 90-180 (dBi) -6.21 -6.41 -6.29 -6.26 -6.3 -5.86 -5.88 -6.14 -6 .08 -6.41 -6.37 -5.88 -5.72 -5.79 -5.79 -5.83 -5.74 -5.24 -5.19 -5.57 -5.47 Peak EIRP (dBi) 0.72 0.53 0.71 0.82 0.84 1.31 1.36 1.17 1.27 0.92 1 1.53 1.7 7 1.74 1.75 1.73 1.91 2.44 2.47 2.08 2.11 Directivity (dBi) 5.34 5.32 5.37 5.43 5.46 5.46 5.51 5.53 5.54 5.47 5.51 5. 59 5.69 5.75 5.76 5.77 5.83 5.82 5.75 5.68 5.55 Efficiency (dB) -4.62 -4.79 -4.66 -4.61 -4.62 -4.15 -4.15 -4.36 -4.27 -4. 55 -4.51 -4.06 -3.92 -4.01 -4.01 -4.04 -3.92 -3.38 -3.28 -3.6 -3.44 Efficiency (%) 34.51 33.19 34.2 34.59 34.51 38.46 38.46 36.64 37.41 35.08 35.4 39.26 40.55 39.72 39.72 39.45 40.55 45.92 46.99 43.65 45.29 Gain (dBi) 0.72 0.53 0.71 0.82 0.84 1.31 1.36 1.17 1.27 0.92 1 1.53 1.77 1.74 1.75 1.73 1.91 2.44 2.47 2.08 2.11 NHPRP +/-30 (dBi) -9.39 -9.59 -9.45 -9.39 -9.4 -8.91 -8.89 -9.08 -8.95 -9 .19 -9.15 -8.8 -8.75 -8.93 -9.01 -9.08 -8.99 -8.42 -8.25 -8.46 -8.14 NHPRP +/-45 (dBi) -7.5 -7.71 -7.59 -7.55 -7.57 -7.1 -7.09 -7.28 -7.16 -7. 41 -7.37 -7 -6.94 -7.1 -7.18 -7.25 -7.15 -6.58 -6.42 -6.66 -6.38 Maximum H+V Value (dBi) 0.72 0.53 0.71 0.82 0.84 1.31 1.36 1.17 1.27 0.92 1 1.53 1.77 1.74 1.75 1.73 1.91 2.44 2.47 2.08 2.11 Maximum H+V @ Theta (deg.) 150 150 150 165 165 165 165 165 165 165 165 165 1 65 165 165 165 165 165 165 165 165 Maximum H+V @ Phi (deg.) 315 315 315 315 300 315 300 300 285 285 315 300 315 315 315 315 315 315 315 315 315 Minimum H+V Value (dBi) -15.08 -14.97 -14.57 -14.12 -13.77 -13.22 -12. 86 -12.89 -12.83 -13.26 -13.39 -13.32 -13.29 -13.99 -14.3 -14.45 -14.58 -1 4.39 -14.74 -15.45 -15.59 Minimum H+V @ Theta (deg.) 30 45 45 45 45 45 45 45 45 45 45 45 45 75 75 45 45 45 4 54545 Minimum H+V @ Phi (deg.) 270 270 255 270 270 255 255 255 255 240 270 240 270 90 90 270 270 240 240 240 240 Horizontal ()Ant. Port Inp. Pow. (dBi) 000000000000000000000 H Rad. Pow. (dBi) -7.91 -8.09 -7.95 -7.93 -7.94 -7.48 -7.51 -7.71 -7.6 -7 .93 -7.97 -7.58 -7.57 -7.87 -7.95 -7.98 -7.91 -7.37 -7.27 -7.57 -7.38 H Rad. Pow. 0-90 (dBi) -12.6 -12.73 -12.56 -12.54 -12.52 -12.04 -12.05 -12.22 -12.1 -12.43 -12.53 -12.27 -12.31 -12.61 -12.7 -12.68 -12.5 -11.82 -11.57 -11.73 -11.43 H Rad. Pow. 90-180 (dBi) -9.71 -9.91 -9.79 -9.78 -9.8 -9.36 -9.39 -9.61 -9.5 -9.84 -9.84 -9.38 -9.35 -9.64 -9.72 -9.78 -9.76 -9.29 -9.29 -9.67 -9.5 4 H Peak EIRP (dBi) -0.44 -0.47 -0.21 -0.12 0 0.49 0.54 0.4 0.52 0.17 0.15 0. 64 0.73 0.51 0.42 0.42 0.54 1.09 1.11 0.84 1.02 H Directivity (dBi) 7.47 7.62 7.74 7.81 7.94 7.97 8.05 8.11 8.12 8.1 8.12 8 .22 8.3 8.38 8.37 8.4 8.45 8.46 8.38 8.41 8.4 H Efficiency (dB) -7.91 -8.09 -7.95 -7.93 -7.94 -7.48 -7.51 -7.71 -7.6 -7 .93 -7.97 -7.58 -7.57 -7.87 -7.95 -7.98 -7.91 -7.37 -7.27 -7.57 -7.38 H Efficiency (%) 16.18 15.52 16.03 16.11 16.07 17.86 17.74 16.94 17.38 16 .11 15.96 17.46 17.5 16.33 16.03 15.92 16.18 18.32 18.75 17.5 18.28 H Gain (dBi) -0.44 -0.47 -0.21 -0.12 0 0.49 0.54 0.4 0.52 0.17 0.15 0.64 0.7 3 0.51 0.42 0.42 0.54 1.09 1.11 0.84 1.02 H NHPRP +/-30 (dBi) -12.33 -12.48 -12.33 -12.29 -12.29 -11.82 -11.84 -1 2.02 -11.9 -12.2 -12.3 -12.06 -12.17 -12.56 -12.73 -12.83 -12.78 -12.17 -1 1.95 -12.05 -11.63 H NHPRP +/-45 (dBi) -10.41 -10.61 -10.49 -10.49 -10.52 -10.07 -10.1 -10 .3 -10.18 -10.49 -10.57 -10.29 -10.38 -10.76 -10.93 -11.02 -10.96 -10.36 - 10.17 -10.33 -9.96 Maximum H Value (dBi) -0.44 -0.47 -0.21 -0.12 0 0.49 0.54 0.4 0.52 0.17 0. 15 0.64 0.73 0.51 0.42 0.42 0.54 1.09 1.11 0.84 1.02 Maximum H @ Theta (deg.) 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 Maximum H @ Phi (deg.) 255 255 255 255 255 255 255 255 270 255 270 255 270 27 0 255 270 255 255 75 75 75 Minimum H Value (dBi) -32.5 -30.87 -29.65 -29.22 -28.34 -27.14 -26.67 - 26.64 -26.09 -25.48 -24.9 -24.61 -24.62 -24.44 -24.54 -24.51 -25.75 -32.2 4 -32.76 -33.56 -26.6 Minimum H @ Theta (deg.) 30 30 30 30 30 30 30 30 165 30 30 165 165 165 30 165 13 5 135 150 150 150 Minimum H @ Phi (deg.) 225 225 225 210 210 210 210 210 165 210 210 165 165 16 5 210 165 15 15 0 0 0 Vertical ()Ant. Port Inp. Pow. (dBi) 000000000000000000000 V Rad. Pow. (dBi) -7.36 -7.54 -7.4 -7.33 -7.34 -6.86 -6.83 -7.06 -6.98 -7 .23 -7.11 -6.62 -6.37 -6.3 -6.26 -6.28 -6.13 -5.59 -5.48 -5.83 -5.69 V Rad. Pow. 0-90 (dBi) -12.92 -13.05 -12.85 -12.7 -12.62 -12.04 -11.91 -12.02 -11.82 -11.91 -11.71 -11.25 -11.06 -11.02 -10.98 -10.99 -10.83 -10 .24 -10.08 -10.36 -10.15 V Rad. Pow. 90-180 (dBi) -8.78 -8.98 -8.86 -8.81 -8.87 -8.42 -8.44 -8.7 2 -8.71 -9.03 -8.96 -8.45 -8.18 -8.09 -8.05 -8.07 -7.92 -7.41 -7.34 -7.71 -7 .62 V Peak EIRP (dBi) -0.27 -0.45 -0.26 -0.22 -0.21 0.31 0.33 0.08 0.21 -0.15 -0.07 0.43 0.78 0.93 1.06 1.11 1.27 1.87 1.94 1.57 1.61 V Directivity (dBi) 7.09 7.09 7.14 7.11 7.13 7.17 7.16 7.14 7.19 7.08 7.04 7.05 7.15 7.23 7.32 7.39 7.4 7.46 7.42 7.4 7.3 V Efficiency (dB) -7.36 -7.54 -7.4 -7.33 -7.34 -6.86 -6.83 -7.06 -6.98 -7 …
Text truncated - open the document above for the full version.
Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 21 Set Up Photo of Radiated Emission EMI Below 1 GHz Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 21 Above 1 GHz Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 18 of 21 Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 19 of 21 RF Below 1 GHz Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 20 of 21 Above 1 GHz Registration number: W6M22512-24857-FCC FCC ID: GX9BX29F1919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 21 of 21
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 918.0375 MHz - 924.48 MHz | 16.00 mW |

Tedee doorlock 919
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smart Home Alarm System
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Garage Tilt Sensor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Outdoor Door Sensor
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Smart Home Alarm System
Equipment Class
PCB - PCS Licensed Transmitter