FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Climax Technology Co Ltd/
  3. GX9TDL919

GX9TDL919Tedee doorlock 919

Climax Technology Co Ltd
Tedee doorlock 919 - FCC ID GX9TDL919 - Climax Technology Co Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jun 01, 2026
Application Purpose
Original Equipment
Equipment Note
Tedee doorlock 919
Frequency Range
918.03750000 - 924.48000000
Company
Climax Technology Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Agent letter FCC attestation statement Kiwa Page 1 of 2 RF_753, Issue 4 17-07-2025 [Climax Technology Co Ltd] U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) TO: Kiwa Nederland B.V. Wilmersdorf 50 7327 AC Apeldoorn Postbus 137 7300 AC Apeldoorn Netherlands ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company name: Climax Int'I Corp. FRN: ☒ 10 digit number: 0033602137 ☐ The US Agent does not have a FRN because this person does not do business with the FCC Contact person name: George Lin (& Shirley Wang) Street address: 5661 Palmer Way, Ste K ZIP/City/State Carlsbad, CA 92010 Telephone number: 760-476-1978 Email address: [email protected] [email protected] Signature: Date: 2026-05-20 This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission- related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Climax Technology Co Ltd FCC ID: GX9TDL919 FRN: 0021168695 Contact person name: George Lin Street address: No. 258, Sinhu 2nd Rd., Neihu District ZIP/City/State/Country Taipei City 114 Telephone number: 886-2-2794-0001 Email address: [email protected] Signature: Date: 2026-05-20 Agent letter FCC attestation statement Kiwa Page 2 of 2 RF_753, Issue 4 17-07-2025 [Climax Technology Co Ltd] Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvdM 02 1 15-05-2023 Added FRN to Agent details RvdM 03 1 06-06-2024 Added FRN to Applicant details RvdM 04 1 17-07-2025 -Changed Grantee code into FCC ID -Added additional option regarding the use of a FRN for the US Agent PR Issued/modified by : Pieter Robben Function : Certification assessor Revision : 04 Date : 17-07-2025 Verified by : Willem Jan Jong Function : Team Lead Date : 17-07-2025 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 17-07-2025

Attestation Statements

Covered list attestation FCC application letter Kiwa Page 1 of 2 RF_755_03 06-06-2024 Certification Application Attestation Statements < Climax Technology Co Ltd> <FRN: 0021168695> < No. 258, Sinhu 2nd Rd., Neihu District,> <114> <Taipei City> <Taiwan ( R.O.C.)> Subject: FCC ID: <GX9TDL919> To Whom It May Concern: Statement for 47 CFR section 2.911(d)(5)(i) 1. [Climax Technology Co Ltd] certifies that as of the date of the application the equipment for which authorization is sought is not “covered” equipment 1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not “covered” equipment. 2. [Climax Technology Co Ltd] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Additional Explanation: <N/A> Statement for 47 CFR section 2.911(d)(5)(ii) [Climax Technology Co Ltd] (“the applicant”) certifies that, as of the date of the filing of this application, the applicant - is / - is not (3) identified on the Covered List as an entity producing “covered” equipment. Date: 2026/05/20 City: Taipei City 114 Name(2) : George Lin Function: Hardware Engineer Telephone number: 886-2-2794-0001 Email address: [email protected] Signature: 1 - The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist . (2): For FCC it must be the Grantee Code “owner” or the authorized agent. (3): double click on the appropriate box and select ‘’checked” then “OK” Covered list attestation FCC application letter Kiwa Page 2 of 2 RF_755_03 06-06-2024 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 01 07-02-2023 1 st version RvM 02 1 15-02-2023 Changed Applicant to Company and added “Subject: FCC ID: “ RvdM 03 1 06-06-2024 FRN added at certification application and included [Insert Company Name Here] for the statements RvdM Issued/modified by : Richard van de Meer Function : Certification assessor Revision : 03 Date : 06-06-2024 Verified by : Willem Jan Jong Function : Team Lead Date : 06-06-2024 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 06-06-2024

Cover Letter(s)

RF_160_06 Declaration of Authorisation Date of issue 13-08-2025 Declaration of Authorization We Name: Climax Technology Co Ltd Address: No. 258, Sinhu 2nd Rd., Neihu District, City: Taipei City 114, Country: Taiwan ( R.O.C.) Declare that: Name Representative of agent: Penny Lin (1) Agent Company name: Worldwide Testing Services (Taiwan) Co., Ltd. Address: 6F., No. 58, Ln. 188, Ruey-Kuang Rd., Neihu, City: Taipei City, Country Taiwan (R.O.C.) is authorized to apply for Certification of the following product(s): Product description: Tedee doorlock 919 Type designation: Tedee doorlock 919 Trademark: NA Validity/ expiry date on our behalf. Date: 2026/05/20 City: Taipei City Name: George Lin (2) Function: Hardware Engineer Signature: ............................... Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent. Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 05 1 02-01-2023 History sheet added AG 06 all 13-08-2025 Kiwa logo change AG Issued/modified by : Axel Gase Function : Manager Quality Assurance Revision : 06 Date : 13-08-2025 Verified by : Willem Jan Jong Function : Team Lead Date : 13-08-2025 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 13-08-2025

Cover Letter(s)

FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 1 of 2 Company Name: Climax Technology Co Ltd Address: No. 258, Sinhu 2nd Rd., Neihu District, City: Taipei City 114, Country: Taiwan ( R.O.C.) To: Kiwa Netherlands B.V., Dept. FCC TCB Wilmersdorf 50 7327 AC Apeldoorn The Netherlands Subject: Request for confidentiality FCC ID: GX9TDL919 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, a pplicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Business considerations Date: 2026/05/20 Name and signature of applicant: George Lin Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should state in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Kiwa NL B.V. at least 7 days before date of actual marketing or before expiration of the STC period FCC, Request for non-disclosure Date: 18-08-2025 RF_501, Issue 12 Page 2 of 2 Revision Record Sheet: Revision Section number Page number Date Remark(s) issued by 10 1 02-01-2023 History sheet added AG 11 1 & 2 23-06-2023 Corrected date and page# WJJ 12 all 18-08-2025 Kiwa logo change AG Issued/modified by : Axel Gase Function : Manager Quality Assurance Revision : 12 Date : 18-08-2025 Verified by : Willem Jan Jong Function : Team Lead Date : 18-08-2025 Released by : Axel Gase Function : Manager Quality Assurance Date of release: : 18-08-2025

External Photos

Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 2 of 19 External Photos Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 3 of 19 Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 4 of 19 Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 5 of 19 Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 6 of 19 Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 7 of 19 Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 8 of 19 Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 9 of 19

RF Exposure Info

of Applicant: CLIMAX TECHNOLOGY CO., LTD. Address: No. 258, Sinhu 2nd Rd., Neihu District, Taipei City 114, Taiwan ( R.O.C.) Tested and Prepared by Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22604-25105-EE 6F, NO. 58, LANE 188, RUEY-KUANG RD., NEIHU TAIPEI 114, TAIWAN, R.O.C. TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] FCC RF Exposure Exemption report for Tedee doorlock 919 Model No.: Tedee doorlock 919 FCC ID: GX9TDL919 Registration number: W6M22604-25105-EE FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 1 of 7 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES .......................................................................................................................................... 2 1.2 TESTING LABORATORY ................................................................................................................ 2 1.3 A PPLICATION DETAILS ................................................................................................................. 3 1.4 G ENERAL INFORMATION OF TEST ITEM ........................................................................................ 4 1.5 T EST STANDARDS ......................................................................................................................... 4 2 TEST CONFIGURATION .............................................................................................................. 5 2.1 T EST ENVIRONMENT .................................................................................................................... 5 2.2 M EASUREMENT UNCERTAINTY .................................................................................................... 5 2.3 TEST EQUIPMENT LIST ................................................................................................................. 5 3 EQUIVALENT ISOTROPIC RADIATED POWER (EIRP)....................................................... 6 3.1 EXEMPTION LIMITS FOR ROUTINE EVALUATION .......................................................................... 6 Registration number: W6M22604-25105-EE FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 2 of 7 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. Laboratory disclaimer- 1. The test results of this test report relate exclusively to the item tested as specified in 1.5. 2. The test report may only be reproduced or published in full. 3. Reproduction or publication of extracts from the report requires the prior written approval of the Worldwide Testing Services(Taiwan) Co., Ltd. 4. Antenna gain is provided by applicant and laboratory issue relevant data and results. Tester: May 27, 2026 Sky Liu Date WTS-Lab. Name Signature Technical responsibility for area of testing: May 27, 2026 Kevin Wang Date WTS Name Signature Registration number: W6M22604-25105-EE FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 3 of 7 1.2 Testing laboratory 1.2.1 Location 10m OATS No.5-1, Lishui, Shuang Sing Village, Wanli Dist., New Taipei City 207, Taiwan (R.O.C.) 3 meter semi-anechoic chamber No. 99, Sec. 1, Balian Rd., Xizhi Dist., New Taipei City 221032, Taiwan (R.O.C.) Worldwide Testing Services (Taiwan) Co., Ltd. 6F., No. 58, Ln. 188, Ruiguang Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.) Tel: 886-2-6606-8877 1.2.2 Details of accreditation status Accredited testing laboratory FCC filed test laboratory Reg. No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Test location, where different from Worldwide Testing Services (Taiwan) Co., Ltd. : Name: ./. Accredited no.: ./. Street: ./. Town: ./. Country: ./. 1.3 Application details Approval holder Name: CLIMAX TECHNOLOGY CO., LTD. Street: No. 258, Sinhu 2nd Rd., Neihu District, Town: Taipei City 114, Country: Taiwan ( R.O.C.) Manufacturer: (if applicable) Name: ./. Street: ./. Town: ./. Country: ./. Registration number: W6M22604-25105-EE FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 4 of 7 Date of receipt of test item: April 24, 2026 Date of test: from April 27, 2026 to May 21, 2026 1.4 General information of Test item Type of test item: Tedee doorlock 919 Model number: Tedee doorlock 919 Multi-listing model number: ./. Sample no.: #01 Technical data Frequency band: 918.0375-924.48 MHz Mode Frequency (MHz) Power (dBm) 900M 918.0375 MHz 11.29 924.48 MHz 9.16 Power supply: Battery 9 Vd.c. Operation modes: Duplex Modulation type: FSK Antenna type: FPC antenna Antenna gain: -2.82636 dBi Host device: none Classification: Fixed Device Mobile Device (Human Body distance > 20cm) Portable Device (Human Body distance < 20cm) 1.5 Test standards 47 CFR FCC Part 1 Subpart I, section 1.1310 FCC KDB Publication 447498 D01 General RF Exposure Guidance v06 Registration number: W6M22604-25105-EE FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Page 5 of 7 2 Test configuration 2.1 Test environment Relative humidity content: 20 ... 75 % Air pressure: 86 ... 103 kP…

Text truncated - open the document above for the full version.

Test Report

1324 F E D 576 C B 8 A TEDEE-RF-ANT-A V1.0 2025.08.27 Frequency (MHz) 800 804 808 812 816 820 824 828 832 836 840 Point ValuesAnt. Port Input Pwr. (dBm) 00000000000 Tot. Rad. Pwr. (dBm) -13.1021 -13.4994 -13.3401 -13.0267 -12.5189 -12 .5237 -12.5911 -12.2343 -12.0768 -12.0587 -11.6536 Peak EIRP (dBm) -6.94954 -7.27284 -7.42354 -6.8912 -6.23182 -6.33912 - 6.34552 -5.91506 -5.71423 -5.56638 -5.13723 Directivity (dBi) 6.15254 6.22655 5.91659 6.13549 6.28705 6.18458 6.24 56 6.31926 6.36253 6.49233 6.51634 Efficiency (dB) -13.1021 -13.4994 -13.3401 -13.0267 -12.5189 -12.5237 -12.5911 -12.2343 -12.0768 -12.0587 -11.6536 Efficiency (%) 4.89544 4.46746 4.63434 4.98116 5.59903 5.5928 5.50665 5 .97818 6.19904 6.22484 6.83349 Gain (dBi) -6.94954 -7.27284 -7.42354 -6.8912 -6.23182 -6.33912 -6.345 52 -5.91506 -5.71423 -5.56638 -5.13723 Total Frequency (MHz)Point ValuesAnt. Port Input Pwr. (dBm)Tot. Rad. Pwr. (dBm)Peak EIRP (dBm)Directivity (dBi)Efficiency (dB)Efficiency (%)Gain (dBi) 844 848 852 856 860 864 868 872 876 880 884 00000000000 -11.026 -10.8724 -10.6044 -10.0039 -9.65853 -9.72507 -9.51259 -9.10069 -8.98519 -9.22553 -8.7435 -4.39025 -4.32875 -4.17832 -3.49169 -3.27517 -3.2775 -3.17918 -2.75869 -2.65126 -2.9935 -2.4875 6.63575 6.54367 6.42606 6.51223 6.38336 6.44757 6.33341 6.34199 6.33393 6.23203 6.256 -11.026 -10.8724 -10.6044 -10.0039 -9.65853 -9.72507 -9.51259 -9.10069 -8.98519 -9.22553 -8.7435 7.89587 8.18009 8.70086 9.99097 10.818 10.6535 11.1877 12.3007 12.6322 1 1.9522 13.3552 -4.39025 -4.32875 -4.17832 -3.49169 -3.27517 -3.2775 -3.17918 -2.75869 -2.65126 -2.9935 -2.4875 Frequency (MHz)Point ValuesAnt. Port Input Pwr. (dBm)Tot. Rad. Pwr. (dBm)Peak EIRP (dBm)Directivity (dBi)Efficiency (dB)Efficiency (%)Gain (dBi) 888 892 896 900 904 908 912 916 920 924 928 00000000000 -8.45929 -8.74372 -8.62472 -8.49353 -8.49677 -8.95881 -9.05823 -8.5273 6 -9.06581 -9.1123 -9.38913 -2.22823 -2.59964 -2.51928 -2.46111 -2.49035 -2.98825 -3.36444 -2.8263 6 -3.4975 -3.69412 -3.93101 6.23105 6.14409 6.10544 6.03242 6.00642 5.97056 5.6938 5.70101 5.56831 5 .41818 5.45812 -8.45929 -8.74372 -8.62472 -8.49353 -8.49677 -8.95881 -9.05823 -8.5273 6 -9.06581 -9.1123 -9.38913 14.2584 13.3545 13.7255 14.1464 14.1359 12.7092 12.4216 14.0367 12.3999 12.2679 11.5103 -2.22823 -2.59964 -2.51928 -2.46111 -2.49035 -2.98825 -3.36444 -2.8263 6 -3.4975 -3.69412 -3.93101 Frequency (MHz)Point ValuesAnt. Port Input Pwr. (dBm)Tot. Rad. Pwr. (dBm)Peak EIRP (dBm)Directivity (dBi)Efficiency (dB)Efficiency (%)Gain (dBi) 932 936 940 944 948 952 956 960 964 968 972 00000000000 -9.29631 -9.63582 -10.423 -10.1207 -10.5347 -11.1072 -10.9941 -11.1419 -11.008 -11.0198 -10.7334 -4.11875 -4.53735 -5.50209 -5.4539 -5.94558 -7.02762 -7.11067 -7.40872 -7.4109 -7.25465 -7.11237 5.17756 5.09847 4.92094 4.66676 4.58915 4.07963 3.88345 3.73322 3.59715 3.76517 3.62107 -9.29631 -9.63582 -10.423 -10.1207 -10.5347 -11.1072 -10.9941 -11.1419 -11.008 -11.0198 -10.7334 11.759 10.8747 9.07188 9.72599 8.84153 7.74953 7.95404 7.68787 7.92858 7 .9071 8.4461 -4.11875 -4.53735 -5.50209 -5.4539 -5.94558 -7.02762 -7.11067 -7.40872 -7.4109 -7.25465 -7.11237 Frequency (MHz)Point ValuesAnt. Port Input Pwr. (dBm)Tot. Rad. Pwr. (dBm)Peak EIRP (dBm)Directivity (dBi)Efficiency (dB)Efficiency (%)Gain (dBi) 976 980 984 988 992 996 1000 0000000 -10.4587 -10.8384 -10.5446 -10.3624 -10.7273 -10.6347 -11.1921-6.82356 -7.26206 -7.0606 -6.94804 -7.11127 -7.35104 -7.87835 3.63511 3.57639 3.48398 3.41433 3.61598 3.28365 3.31376 -10.4587 -10.8384 -10.5446 -10.3624 -10.7273 -10.6347 -11.1921 8.99773 8.24432 8.82149 9.19948 8.45813 8.64035 7.59957 -6.82356 -7.26206 -7.0606 -6.94804 -7.11127 -7.35104 -7.87835

Test Report

of Applicant: CLIMAX TECHNOLOGY CO., LTD. Address: No. 258, Sinhu 2nd Rd., Neihu District, Taipei City 114, Taiwan ( R.O.C.) Tested and Prepared By Worldwide Testing Services (Taiwan) Co., Ltd. FCC Registration No.: TW1072, TW1140, TW1146, TW1477, TW0037 Industry Canada filed test laboratory Reg. No.: 20037, 31634 Report No.: W6M22604-25105-C-1 6F., No. 58, Ln. 188, Rueiguang Rd., Neihu Dist., Taipei City , Taiwan (R.O.C.) TEL: 886-2-66068877 FAX: 886-2-66068879 E-mail: [email protected] 47 CFR PART 15 SUBPART C TEST REPORT for Tedee doorlock 919 Model No.: Tedee doorlock 919 FCC ID: GX9TDL919 Registration number: W6M22604-25105-C-1 FCC ID: GX9TDL919 Worldwide Testing Services (Taiwan) Co., Ltd. Page 1 of 28 TABLE OF CONTENTS 1 GENERAL INFORMATION .......................................................................................................... 2 1.1 NOTES ........................................................................................................................................................................ 2 1.2 TESTING LABORATORY .......................................................................................................................................... 3 1.2.1 Location .................................................................................................................................. 3 1.2.2 Details of accreditation status ................................................................................................ 3 1.3 DETAILS OF APPROVAL HOLDER ......................................................................................................................... 3 1.4 APPLICATION DETAILS ........................................................................................................................................... 3 1.5 GENERAL INFORMATION OF TEST ITEM ............................................................................................................. 4 1.6 TEST STANDARDS .................................................................................................................................................... 4 1.7 TEST PROCEDURE .................................................................................................................................................... 4 2 TECHNICAL TEST ......................................................................................................................... 5 2.1 SUMMARY OF TEST RESULTS ................................................................................................................................ 5 2.2 TEST ENVIRONMENT............................................................................................................................................... 5 2.3 TEST EQUIPMENT LIST .......................................................................................................................................... 5 2.4 GENERAL TEST PROCEDURE ................................................................................................................................ 7 3 TEST RESULTS (ENCLOSURE) .................................................................................................. 9 3.1 PEAK OUTPUT POWER (TRANSMITTER) ........................................................................................................... 10 3.2 TRANSMITTER RADIATED EMISSIONS IN RESTRICTED BANDS .................................................................. 12 3.3 SPURIOUS EMISSIONS (TX) .................................................................................................................................. 13 3.4 CARRIER FREQUENCY SEPARATION ................................................................................................................. 14 3.5 NUMBER OF HOPPING FREQUENCIES ............................................................................................................... 16 3.5.1 Pseudorandom Frequency Hopping Sequence .................................................................... 17 3.5.2 Coordination of hopping sequences to other transmitters .................................................... 17 3.5.3 System Receiver Hopping Capability ................................................................................... 17 3.6 TIME OF OCCUPANCY (DWELL TIME) .............................................................................................................. 18 3.7 20DB BANDWIDTH .............................................................................................................................................. 21 3.7.1 System Receiver Input Bandwidth ......................................................................................... 22 3.8 BAND-EDGE COMPLIANCE OF RF EMISSIONS ............................................................................................... 23 3.9 RADIATED EMISSIONS FROM DIGITAL PART ................................................................................................. 26 3.10 POWER LINE CONDUCTED EMISSION ............................................................................................................... 27 Registration number: W6M22604-25105-C-1 FCC ID: GX9TDL919 Worldwide Testing Services (Taiwan) Co., Ltd. Page 2 of 28 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained …

Text truncated - open the document above for the full version.

Test Setup Photos

Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 14 of 19 Set Up Photo of Radiated Emission EMI Below 1 GHz Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 15 of 19 Above 1 GHz Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 16 of 19 Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 17 of 19 RF Below 1 GHz Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 18 of 19 Above 1 GHz Registration number: W6M22604-25105-FCC FCC ID: GX9TDL919 Worldwide Testing Services(Taiwan) Co., Ltd. Appendix page 19 of 19

Contact Information

Applicant

George Lin(Hardware Engineer)
[email protected]Fax: 886-2-2794-5512

Technical Contact

Climax Int'I Corp.George Lin
[email protected]

5661 Palmer Way, Ste K · 92010 · United States

Test Firm

Worldwide Testing Services (Taiwan) Co., Ltd.Rex Kao
[email protected]Fax: 886-2-6606-8879

Technical Specifications

#Rule PartsFrequency RangePower Output
115C918.0375 MHz - 924.48 MHz14.00 mW
Confidentiality
Long Term
Grant Notes
Power Output is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with specific operating instructions for satisfying RF exposure compliance.

Other Applications from Climax Technology Co Ltd

Smart Home Alarm System - FCC ID GX9HSGWM8M1ZB - Climax Technology Co Ltd
GX9HSGWM8M1ZB

Smart Home Alarm System

May 25, 2026

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Garage Tilt Sensor - FCC ID GX9GDTS1 - Climax Technology Co Ltd
GX9GDTS1

Garage Tilt Sensor

Mar 11, 2026

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Outdoor Door Sensor - FCC ID GX9DC32EX - Climax Technology Co Ltd
GX9DC32EX

Outdoor Door Sensor

Mar 11, 2026

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
Smart Home Alarm System - FCC ID GX9HSGWMAXF1919 - Climax Technology Co Ltd
GX9HSGWMAXF1919

Smart Home Alarm System

Jan 27, 2026

Equipment Class

PCB - PCS Licensed Transmitter
Outdoor Bell Box - FCC ID GX9BX29F1919 - Climax Technology Co Ltd
GX9BX29F1919

Outdoor Bell Box

Jan 05, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter