
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
JULY. 19. 2002 560A 1 OPERATION: A. REGULAR TRANSMITTER OPERATION: Transmitter Button System Function Remark Lock Doors & Arm System with Chirp Press & release within 1 seconds Lock Doors & Arm System without Chirp Press & release over 1 seconds - Arm and Delete The 2 Stage Shock Sensor Press twice within 3 seconds. (3-second) Panic function Press and Hold for 3 seconds Unlock Doors & Disarm System with Chirp Press & release within 1 seconds Unlock Doors & Disarm System without Chirp Press & release over 1 seconds - Two Steps Door Unlock & Disarm System Press twice within 3 seconds. (2-second) Channel 2 (Trunk) Timer Control Press and Hold for 2 seconds - Activate or Turn Off The Remote Start or Press twice within 3 seconds. B. LED display: LED Function LED Function Off Disarmed Zone 1: Warn-Away Trigger Slow Flash Armed 2 flashes... pause Zone 2: Trigger on Trunk/Hood Fast Flash Passive Arming 3 flashes... pause Zone 3: Trigger on Door Switch On (Solid) Valet Mode 4 flashes... pause Zone 4: Trigger on Optional Sensor 5 flashes... pause Zone 5: Trigger on Ignition Switch C. CHIRP INDICATORS: D. PARKING LIGHT: Chirp Function Parking light Function 1 chirp Arm 1 flash Arm 2 chirps Disarm 2 flashes Disarm 3 chirps Defective Reminder 3 flashes Disarm / Triggered 4 chirps Disarm / Triggered 12 flashes Car Locator Constant On Under Remote Start E. ALARM OPERATING CONDITION: Siren, Horn Parking Light LED Doors Starter Dome Light 1. Arming 1 or 3 Chirps 1 Flash Slow Flash Locking Disable 2. Disarming 2 or 4 Chirps 2 or 3 Flashes Fast Flash Unlocking Turns on for 30-second 3. Trigger Alarming Flashes Slow Flash Disable Flashes 4. Panic Alarming Flashes Flashes F. ACTIVE LOCK & ARM: 1.Press button on the transmitter. 2.The horn will chirp once and parking light will flash once indicating that the system is now armed. The vehicle doors will lock upon arming when interfaced with the security system. SILENT ARMING / DISARMING: Press and hold the or button on the transmitter over 1 second will arm or disarm your security system, No chirp sound will be heard, arm / disarm confirmation will be through the vehicles parking lights only. DEFECTIVE SENSOR REMINDER: If the siren sounds 3 chirps, then you have left a door, trunk, or hood lid ajar. (See Alarm Feature “I - 4 Programming) SHOCK SENSOR / OPTIONAL SENSOR BY-PASS: Press the button once: The siren chirps once, The system is armed. JULY. 19. 2002 560A 2 Press the button a second time within 3 seconds: The siren chirps twice, the Shock Sensor is now bypassed. The sensor bypass feature is programmed to activate for one arming cycle only. The security system will return to normal operation during the next arming cycle. H. PASSIVE ARMING Active arming / disarming is controlling your security system via the remote transmitter. This security system is equipped with an optional Passive Arming feature, which allows the security system to arm 30 seconds after the last door is closed. Operation is as follows. 1. Turn the ignition to the “OFF” position and exit the vehicle. 2. After all entrances are closed, the security system LED will flash fast for 30 seconds. If you reopen any door / hood / trunk, the security system LED will stop flashing. It will begin flashing again once the vehicle all entrances are closed. 3. After 30-second timer has elapsed, the security system will automatically “ARM”. The siren will chirp [1] time and the parking lights will flash [1] time. PASSIVE ARMING WITH PASSIVE DOOR LOCKING (See Alarm Feature “I - 2” Programming): The vehicle doors will automatically lock after passive arming cycle has been completed. G. ACTIVE UNLOCK & DISARM: 1. Press button on the transmitter. 2. The horn will chirp twice and parking light will flash twice to indicating that the security system is now disarmed. The vehicle doors will unlock and dome light wills turns on for 30 seconds upon disarming when interfaced with the security system. TAMPER DISARMING: If alarm triggered, upon disarm the system, siren chirp 4 times, parking light flash 3 times. PATHWAY ILLUMINATION (See Alarm Feature “II - 4” Programming): This feature turns the parking light “ON” for 30 seconds upon a unlock signal and for 10 seconds upon the lock signal. TWO STEPS DOOR UNLOCK (See Alarm Feature “III - 3” Programming):: This feature will independently unlock the drives door only when disarming the security system. Pushing the button a second time within 3 seconds will unlock the entire vehicle. H. DISARMING WITHOUT A TRANSMITTER The Override function may be used if the remote transmitter is lost or inoperative. 1. Enter the vehicle and turn the ignition switch to 'ON’ position. 2. Within 10 seconds push and release the valet switch The alarm will enter the disarm mode. You can now start and operate the vehicle normally. I. VALET MODE: (System in Disarm or Valet mode) The valet switch allows you to temporarily bypass all alarm function, eliminating the need to hand your transmitter to parking attendants or garage mechanics. When the system is in valet mode, all alarm function and remote start function are bypassed, however the remote panic feature and remote door locks will remain operational. To use the valet mode, the system must first be disarmed either by using you remote transmitter, or by operating the Manual override sequence. Enter Valet Mode: 1.From the disarmed condition, turn the ignition to “ON” position. 2.Push and hold valet switch for 2 seconds until the LED turns on. The LED wills remain on as long as the system is in 'valet mode'. Exit Valet Mode: 1.Return to normal operation, turn ignition 'on'. 2.Push and hold valet switch for 2 seconds, The LED wills turns off indicate the system are exiting the valet mode. J. PANIC FUNCTION: The transmitter can be used as a remote panic switch to manually trigger the alarm in case emergency. JULY. 19. 2002 560A 3 1. Press and hold the button for 3 second. The alarm will immediately sound. 2. During panic mode, the normal functio…
Text truncated - open the document above for the full version.
Report No: 40517411 External Photos Report No: 40517411 External Photos Report No: 40517411 External Photos
FCC ID / IC LABEL FORMAT AND LOCATION Applicant: ADVANCE SECURITY INC. FCC ID: H5OR39 IC: 1640-R01 FCC ID: H5OR39 IC: 1640-R01 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. “Complies with Canada RSS-210” LABEL AREA
Report No: 40517411 Internal Photos Report No: 40517411 Internal Photos Report No: 40517411 Internal Photos
(RX-50 Receiver Module) Operational Description Model RX50 is the receivering portion of a muti- purose security device. The associated Transmitter is manufacture by Advance Security Inc. Model No:TX556, FCC ID:H5OT21 / IC ID:1640-T01. It can be used with any P- 50, P- 60 & strxxx alaxxx series alarms. The radio frequency car-alarm is a system that it controllers locking(arm) and unlocking(disarm) the door of vehicle by wireless remote controller. This system consists of transmitter and receiver. The receiver (EUT) is fixed inside the vehicle and powered 12V from car battery. It works intermittently to prevent the battery exhaustion and check the vehicle status. It is designed to operate on a single fixed frequency 433.92 MHz by frequency modulation. It runs continuously to receive the signals completely, when the receiving module in receiver detects several synchronous codes, unique identification code, security code and function code transmitted from transmitter. After receiving the signal, the 8bit CPU in receiver decides which operation will be performed. And then driving circuit in receiver performs selected operations by pressing the button of the remote transmitter. All tuning and verification are performed by the manufacturer and there are no adjustments which can be made by the user. External ground is the chassis of vehicle and receiving antenna is fixed on enclosure of the receiver.
+- +-
Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 FCC CLASS B COMPLIANCE REPORT for UNINTENTIONAL RADIATOR of CAR ALARM RECEIVER Trade Name : Advance Security Inc. Model Number : RX50 Agency Series : N/A Report Number : 40517411-RP Date : June 21, 2004 Prepared for Advance Security Inc. 3F, 48 Ta An Street, Hsi Chih, Taipei Hsien, Taiwan, R. O. C. Prepared by Compliance Certification Services Inc. No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, (338) Taiwan, R.O.C. TEL: 886-3-324-0332 FAX: 886-3-324-5235 This report shall not be reproduced, except in full, without the written approval of Compliance Certification Services Inc. Page 1 of 12 Rev. 00 Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 TABLE OF CONTENTS 1. VERIFICATION OF COMPLIANCE............................................................3 2. PRODUCT DESCRIPTION.............................................................................4 3. TEST FACILITY................................................................................................4 4. MEASUREMENT EQUIPMENT USED.......................................................4 5. TEST CONFIGURATION................................................................................5 6. TESTS CONDUCTED.......................................................................................5 7. RADIATED EMISSION TEST PROCEDURE.............................................5 8. COHERENT TESTS..........................................................................................6 9. EQUIPMENT MODIFICATIONS..................................................................6 10. TEST RESULTS.................................................................................................7 APPENDIX 1 TEST CONFIGURATION PHOTOS...............................................9 Page 2 Rev. 00 Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 1. VERIFICATION OF COMPLIANCE COMPANY NAME : Advance Security Inc. 3F, 48 Ta An Street, Hsi Chih, Taipei Hsien, Taiwan, R. O. C. CONTACT PERSON : Michael Chen / President TELEPHONE NO. : (886-2) 8648-1688 EUT DESCRIPTION : CAR ALARM RECEIVER MODEL NAME/NUMBER : RX50 DATE TESTED : May 24, 2004 REPORT NUMBER : 40517411-RP TYPE OF EQUIPMENT SECURITY EQUIPMENT (UNINTENTIONAL RADIATOR) EQUIPMENT TYPE 433.92 MHz CAR ALARM RECEIVERS MEASUREMENT PROCEDURE ANSI 63.4 / 2001 LIMIT TYPE CERTIFICATION FCC RULE CFR 47, PART 15.109 / CFR 47, PART 15.107 The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in the FCC CFR 47, PART 15. The results of testing in this report apply to the product/system which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Warning: This document reports conditions under which testing was conducted and results of tests performed. This document may not be altered or revised in any way unless done so by Compliance Engineering Services, Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by Compliance Certification Services Inc. will constitute fraud and shall nullify the document. Approved by: Reviewed by: David Wang Rick Yeo Manager Manager Compliance Certification Services Inc. Compliance Certification Services Inc. Page 3 Rev. 00 Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 2. PRODUCT DESCRIPTION Advance Security Inc., Model No: RX50 is the receiving portion of a multi-purpose security device. The associated transmitter is manufactured by Advance Security Inc., FCC ID: H5OT21. 3. TEST FACILITY The open area test sites and conducted measurement facilities used to collect the radiated data are located at No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, Taiwan, R.O.C.. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. The measuring instrument which was utilized in performing the tests documented herein has been calibrated in accordance with the manufacturer's recommendations for utilizing calibration equipment which is traceable to recognized national standards. 4. MEASUREMENT EQUIPMENT USED Open Area Test Site # 4 Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer Advantest R3132 91700456 N.C.R EMI Test Receiver R&S ESVS10 846285/016 04/25/2005 Bilog Antenna Sunol Sciences JB1 A111203 01/09/2005 Turn Table Chance Most N/A N/A N.C.R Antenna Tower Chance Most N/A N/A N.C.R Controller Chance Most N/A N/A N.C.R RF Switch Anritsu MP59B M51067 N.C.R Site NSA CCS N/A N/A 08/08/2004 Spectrum Analyzer Agilent E4446A MY43360131 01/10/2005 Spectrum Analyzer HP 8566B 2937A06102 06/25/2005 Horn Antenna EMCO 3115 5761 02/02/2005 Pre-Amplifier HP 8449B 3008A01266 02/15/2005 Page 4 Rev. 00 Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 5. TEST CONFIGURATION Set frequency generator to 433.92 MHz. EUT receiving transmission continuously. All the wires are placed on the turn table to their maximum length to simulate the worse emission conditions. 6. TESTS CONDUCTED CFR 47, 15.109 RADIATED EMISSION TESTS CONDUCTED AT 3 METERS 7. RADIATED EMISSION TEST PROCEDURE The EUT and all other support equipment are placed on a wooden table 80 cm above the ground screen. Antenna to EUT distance is 3 meters. During the test, the table is rotated 360 degrees to maximize emissions and the antenna is positioned from 1 to 4 meters above the ground screen to further maximize emissions. The antenna is polarized in both vertical and horizontal positions. Monitor the frequency range of interest at a fixed antenna height and EUT azimuth. Frequency span sh…
Text truncated - open the document above for the full version.
Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 RADIATED EMISSION TEST - X-axis Page 10 Rev. 00 Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 RADIATED EMISSION TEST - Y-axis Page 11 Rev. 00 Compliance Certification Services Inc. Date of Issue: June 21, 2004 Report No: 40517411-RP FCC ID: H5OR39 RADIATED EMISSION TEST - Z-axis Page 12 Rev. 00
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.92 MHz - 433.92 MHz | - |

Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Control
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Remote Control
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Remote Control
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Remote Control
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter