Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
•Please read this manual and the enclosed safety materials carefully! •The door WILL NOT CLOSE unless the Protector System ® is connected and properly aligned. •Periodic checks of the garage door opener are required to ensure safe operation. •The model number is located on the front cover of the opener. •This garage door opener is ONLY compatible with myQ ® and Security+ 2.0 ® accessories. •Attach warning labels to the location indicated on label. This product is intended for installation only by trained garage door technicians. This product may require adjustments to door springs and/or track configurations. This product is not intended for use on low headroom tracks with outside pick up drums or garage doors utilizing extension springs. For Residential Use Install On Sectional Doors With Torsion Assemblies Only Wall Mount Wi-Fi ® Garage Door Opener Models 98032 LiftMaster 300 Windsor Drive Oak Brook, IL 60523 Register your garage door opener to receive updates and offers from LiftMaster Take a photo of the camera icon including the points (). Send it in by texting the photo to 71403 (US) or visit www.Liftmaster.photo (Global) SM 2 Preparation When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully. Mechanical Electrical Safety Symbol and Signal Word Review This garage door opener has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict accordance with the instructions and warnings contained in this manual. Table of Contents PREPARATION 2 myQ Serial Number ......................................2 Safety Symbol and Signal Word Review ......2 Unattended Operation ...................................2 Planning ........................................................3 Before You Connect with Your Smartphone 4 Preparing Your Garage Door ........................5 Tools Needed ................................................5 Carton Inventory ...........................................6 Additional Items You May Need ...................6 ASSEMBLY 7 Attach the Collar to the Garage Door Opener .....................................7 Attach Mounting Bracket to Garage Door Opener .....................................8 INSTALLATION 8 Position and Mount the Garage Door Opener .....................................9 Attach the Emergency Release Rope and Handle ..................................................10 Install Automatic Door Lock .......................10 Install the Door Control (Smart Control Panel ® ) ...............................11 Install myQ Remote LED Light ...................12 Install the Protector System ......................13 Connect Power ............................................16 Align the Safety Reversing Sensors ...........17 Install the Battery Backup ...........................18 ADJUSTMENT 19 Identify Door Profile ....................................19 Set Door Profile ...........................................20 Program the Travel 21 Automatic Force Set Up ..............................21 Test the Safety Reversal System ................22 Test the Protector System .........................22 Test the Power Door Lock ..........................23 Test the Emergency Release .......................23 OPERATION 24 Using Your Garage Door Opener ................25 Connect with Your Smartphone .................26 Using the Door Control ...............................27 PROGRAMMING 29 893MAX Remote Control ............................29 Program the myQ Remote LED Light .........30 To Erase the Memory ..................................30 HomeLink ® ..................................................31 MAINTENANCE 32 Care of Your Garage Door Opener ..............32 TROUBLESHOOTING 33 Diagnostic Chart ..........................................33 Additional Troubleshooting .........................34 REPAIR PARTS 36 Installation Parts .........................................36 Garage Door Opener Assembly Parts .........37 CONTACT INFORMATION 37 ACCESSORIES 38 WARRANTY 39 Automatic Garage Door Opener Safety & Maintenance Guide 40 Date of Purchase: Write down the following information for future reference: Product Serial Number: myQ Serial Number: Serial Numbers WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. The Timer-to-Close (TTC) feature, the myQ Smartphone Control app, and myQ Garage Door and Gate Monitor are examples of unattended close and are to be used ONLY with sectional doors. Any device or feature that allows the door to close without being in the line of sight of the door is considered unattended close. The Timer-to-Close (TTC) feature, the myQ Smartphone Control, and any other myQ devices are to be used ONLY with sectional doors. myQ Remote LED Light must be installed to enable use of Timer To Close or myQ Smartphone Control of the door. myQ Serial Number Unattended Operation 3 Preparation Survey your area to see if any of the conditions below apply to your installation. Take note of the drum sizes to make sure they are correct. Depending on your requirements, additional materials may be required. THIS DOOR OPENER IS COMPATIBLE WITH: • Doors that use a torsion bar and springs. The torsion bar must be 1" (2.5 cm) diameter. NOT compatible with reverse wound drums. • Standard lift sectional doors using 4-6" (10-15 cm) diameter drums. • 4-6" (10-15 cm) straight drum…
Text truncated - open the document above for the full version.
22 1 With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2x4 laid flat) on the floor, centered under the garage door. Test the Safety Reversal System 2 Press the remote control push button to close the door. The door MUST reverse when it makes contact with the board. If the door stops but does not reverse: 1. Repeat Program the Travel (see Adjustment Step 1); 2. Repeat the Safety Reversal test. If the test continues to fail, call a trained door systems technician. Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm) high object (or 2x4 laid flat) on the floor. 5 Test the Protector System ® 1 Open the door. Place an obstruction in the path of the door. The garage door opener will not close from a remote control if the LED in either safety reversing sensor is off (alerting you to the fact that the sensor is misaligned or obstructed). If the garage door opener closes the door when the safety reversing sensor is obstructed (and the sensors are no more than 6 inches [15 cm] above the floor), call for a trained door systems technician. Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. 2 Press the remote control push button to close the door. The door will not move more than an inch (2.5 cm). 6 Adjustment 23 7 Test the Power Door Lock 1. With the door fully closed, check to ensure that the power lock bolt is visible protruding through the track. 2. Press the button on the remote control to open the garage door. The power door lock should retract before the door begins to move. 3. Press the button on the remote control to close the garage door. When the door reaches the fully closed position, the power door lock should automatically activate to secure the door. NOTE: The power door lock can be manually released by sliding the manual release handle to the open position. However, if the power door lock does not function, contact Chamberlain for a replacement. 8 Test the Emergency Release OPEN THE DOOR MANUALLY: 1. Close the garage door. Slide the manual release handle on power door lock to open before proceeding. 2. Pull down on the emergency release handle until you hear a click. 3. Lift the door manually. RECONNECT THE DOOR TO THE GARAGE DOOR OPENER: 1. Pull down on the emergency release handle until you hear a click. The door will reconnect on the next UP or DOWN operation. To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage door ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. Emergency Release Handle Adjustment (continued) Power Door Lock Manual Release Lock Bolt “Locked” Power Door Lock Manual Release Lock Bolt "Locked" 24 Operation IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: 1. Read and follow all warnings and instructions. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls. 3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel. 4. ALWAYS keep garage door in sight and away from people and objects until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY OPENED DOOR. 6. If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Use caution when using this release with the door open. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly and increasing the risk of SEVERE INJURY or DEATH. 7. NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. 8. NEVER use emergency release handle to pull garage door open or closed. If rope knot becomes untied, you could fall. 9. After ANY adjustments are made, the safety reversal system MUST be tested. 10. Safety reversal system MUST be tested every month. Garage door MUST reverse on contact with 1-1/2" high (3.8 cm) object (or a 2x4 laid flat) on the floor. Failure to adjust the garage door opener properly increases the risk of SEVERE INJURY or DEATH. 11. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH. 12. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician. 13. ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers. 14. This garage door opener system is equipped with an unattended operation feature. The door could move unexpectedly. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 15. SAVE THESE INSTRUCTIONS. 25 FEATURES Your garage door opener is equipped with features to provide you with greater control over your garage door operation. Alert2Close The Alert2Close feature provides a visual and an audible alert that an unattended door is closing. TIMER-TO-CLOSE (TTC) The TTC feature automatically closes the door after a specified time period that can be adjusted using a TTC enabled door control (Models 881LMW or 880LMW). Prior to and during the door closing the garage door opener lights will blink and the garage door opener will beep. myQ Remote LED Light must be installed to use TTC or myQ to control the door. myQ myQ allows you to control your garage door opener fr…
Text truncated - open the document above for the full version.
TO: Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd Columbia, MD 21046 Date: February 10, 2023 Pursuant to FCC 22-84 Report and Order and KDB 986446 D01 Covered Equipment v01, the Commission adopted new FCC requirements to protect the nation’s networks and supply chains from equipment that poses an unacceptable risk to national security or the safety of U.S. persons. Specifically, the Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List. Certifications concerning “covered” equipment. Section 2.911(d)(5)(i)-(ii). The Chamberlain Group LLC (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The Chamberlain Group LLC (“the applicant”) certifies that as of the date of the filing of the application, the applicant is not identified on the covered list as an entity producing covered equipment. Thank you. Regards, Signature: Thomas DeSilvia Date: February 10, 2023 Signed by: Thomas DeSilvia
TO: Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd Columbia, MD 21046 Date: February 10, 2023 Pursuant to FCC 22-84 Report and Order and KDB 986446 D01 Covered Equipment v01, the Commission adopted new FCC requirements to protect the nation’s networks and supply chains from equipment that poses an unacceptable risk to national security or the safety of U.S. persons. Specifically, the Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List. Certification designating a U.S. agent for service of process. As required by section 2.911(d)(7), the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. The Chamberlain Group LLC (“the applicant”) consent to accept the service of process. The Chamberlain Group LLC (“the applicant”) acknowledges to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission- related proceeding involving the equipment. If the agent changes then the TCB and the FCC must be notified. Contact Name: Tom DeSilvia, Director Corporate Compliance Address: 300 Windsor Drive Oak Brook, IL. 60523 Telephone No: 1-630-993-8618 Email: [email protected] FRN: 004301545 Regards, Signature: Thomas DeSilvia Date: February 10, 2023 Signed by: Thomas DeSilvia This Agreement is valid until rescinded by the Applicant
Jun 16, 2023 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: HBW0350 Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: - e.g. Block Diagram - e.g. Schematics - e.g. Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Tom DeSilvia, Director Corporate Compliance The Chamberlain Group LLC. Email: [email protected]
Jun 16, 2023 To: Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Short Term Confidentiality Request for FCC ID: HBW0350 To Whom It May Concern: Pursuant to sections 0.457 and 0.459 of CFR 47, and to avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 or 180 days; or for a specified date of / / not to exceed 180 days from the Grant Date. See KDB 726920. - e.g. User Manual - e.g. Internal Photos - e.g. Test Setup photos - e.g. External Photos The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, Tom DeSilvia, Director Corporate Compliance The Chamberlain Group LLC. Email: [email protected]
Date: Jun 16, 2022 Page 1 of 1 The Chamberlain Group LLC 300 Windsor Dr Oak Brook, IL 60523 To: Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd Columbia, MD 21046 New FCC ID: HBW0350; IC 2666A-0350 for our Main Control/transceiver for use in MYQ Garage Door Opener To whom it may concern, We would like to submit for Certification to FCC a new FCC ID: HBW0350 for our Main Control/transceiver for use in MYQ Garage Door Opener. Product Description: Wall Mount Garage Door Opener Models: 98032MC, 98032RGDMC. Please find in the following application all related documentation to support this new certification. We would appreciate your prompt attention to the submittal. If there are any questions, please contact me by phone, fax or email. Sincerely, Tom DeSilvia, Director Corporate Compliance The Chamberlain Group LLC. Email: [email protected]
Artwork: 132-3455-000 Revision A 3.41” x 2.41” x .04” (W x H x R) Shown at 100% 20 April 2023 132-3455-000 98032 MC 2023-06-07
Artwork: 132-3455-000 Revision A 3.41” x 2.41” x .04” (W x H x R) Shown at 100% 20 April 2023 132-3455-000 2023-06-07 98032RGD MC
1516 Centre Circle, Downers Grove IL 60515 RF EXPOSURE EXHIBIT Manufacturer Name The Chamberlain Group LLC Manufacturer Address 300 Windsor Drive Oak Brook,IL 60523 Model No. Residential Jackshaft Opener HVIN Specifications FCC “Code of Federal Regulations” Title 47 Part 1.1307(b) FCC “Code of Federal Regulations” Title 47 Part 2.1093 Industry Canada RSS-102 Test Facility Elite Electronic Engineering, Inc. 1516 Centre Circle, Downers Grove, IL 60515 FCC Reg. Number: 269750 IC Reg. Number: 2987A CAB Identifier: US0107 Test Procedure FCC KDB 447498 D01 General RF Exposure Guidance v06 RSS-102, Issue 5 Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands ANSI/IEEE C95.1-1992, "Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz," Evaluation Distance 20 cm Radio Access Technology ƒ Transmit Frequency (MHz) ERP/P (dBm) ERP/P (mW) WIFI 2412 24.9 309.0295433 BLE 2402 1.5 1.412537545 security 2402 9 7.943282347 900MHz 914 17.56 57.01642723 Equipment is exempt from routine evaluation Radio Access Technology ƒ Transmit Frequency (MHz) ERP/P (mW) Power Threshold (mW) Calculated Power Density (mW/cm 2 ) Power Density Limit (mW/cm 2 ) Fractional Contributions ∑ Fractional Contributions WIFI2412------0.0614794741.000.06150.082 BLE2402------0.0002810151.000.0003 security2402------0.0015802661.000.0016 900MHz914------0.0113430580.610.0186 050DCRJB3 1516 Centre Circle, Downers Grove IL 60515 Radio Access Technology ƒ Transmit Frequency (MHz) S C Calculated Power Density (W/m 2 ) S L Power Density Limit (W/m 2 ) S C :S L Ratio ∑ S C :S L Ratio WIFI24120.6147946815.3660182780.1145718570.16 BLE24020.0028101545.3508045630.000525183 security24020.0158026575.3508045630.002953323 900MHz9140.1134305672.7646880070.041028343 Assessment Results Relevant to General/Uncontrolled Exposure Limits
1516 Centre Circle, Downers Grove IL 60515 ANTENNA EXHIBIT Manufacturer Name The Chamberlain Group LLC Manufacturer Address 300 Windsor Drive Oak Brook,IL 60523 Model No. Residential Jackshaft Opener Specifications FCC “Code of Federal Regulations” Title 47 Part 2.1033(b)(4), 15.203, 15.212, 15.217, 15.219, 15.255 and 15.256 KDB 353028 D01 v01 f01 Industry Canada RSS-GEN Test Facility Elite Electronic Engineering, Inc. 1516 Centre Circle, Downers Grove, IL 60515 FCC Reg. Number: 269750 IC Reg. Number: 2987A CAB Identifier: US0107 Requirement All part 15 applications will need to show how the antenna gain was derived either from a manufacturer data sheet or a measurement. Where the gain of the antenna is inherently accounted for as a result of the measurement, such as field strength measurements on a part 15.249 or 15.231 device, so the gain does not necessarily need to be verified. However, enough information regarding the construction of the antenna shall be provided. Such information maybe photographs, length of wire antenna etc. The antenna gain information shall be made public (not confidential). Any proprietary information such as construction maybe stripped from the gain information report and held confidential. The main antenna information we require is the maximum gain of the antenna for the band of operation. This information must be provided as a data sheet or a measurement report. 1516 Centre Circle, Downers Grove IL 60515 Meandering F Trace antenna 1 inch long for the Realtek WIFI BLE transmitter. 7.2 mm 20 AWG monopole wire antenna for the FHSS transmitter 1516 Centre Circle, Downers Grove IL 60515 8.5 mm 20AWG monopole wire antenna for the security 3.0 transmitter
Engineering Test Report No. 2202429-03 Report Date December 15, 2022 Manufacturer Name Chamberlain Group, LLC. Manufacturer Address 300 Windsor Drive Oak Brook, IL 60523 Test Item Name Model No. Residential Jackshaft Opener RJOA MPP Date Received November 23, 2022 Test Dates November 28, 2022 through December 5, 2022 Specifications FCC “Code of Federal Regulations” Title 47, Part 15, Subpart B FCC "Code of Federal Regulations" Title 47 Part 15, Subpart C, Section 15.247 Innovation, Science, and Economic Development Canada, RSS-GEN Innovation, Science, and Economic Development Canada, RSS-247 Test Facility Elite Electronic Engineering, Inc. 1516 Centre Circle, Downers Grove, IL 60515 FCC Reg. Number: 269750 IC Reg. Number: 2987A CAB Identifier: US0107 Signature Tested by Mark E. Longinotti Signature Approved by Raymond J. Klouda, Registered Professional Engineer of Illinois – 44894 PO Number 4900084893 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. This report shall not be reproduced, except in full, without the written approval of Elite Electronic Engineering Inc. Elite Electronic Engineering Incorporated certifies that the information contained in this report was obtained under conditions which meet or exceed those specified in the FCC “Code of Federal Regulations” Title 47, Part 15, Subpart B, FCC "Code of Federal Regulations" Title 47 Part 15, Subpart C, Section 15.247 and Innovation, Science, and Economic Development Canada, RSS-247 test specifications. The data presented in this test report pertains to the EUT on the test dates specified. Any electrical or mechanical modifications made to the EUT subsequent to the specified test date will serve to invalidate the data and void this certification. This report must not be used to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the Federal Government. Engineering Test Report No. 2202429-03 This report shall not be reproduced, except in full, without the written approval of Elite Electronic Engineering Inc. Page 2 of 102 Table of Contents 1. Report Revision History ............................................................................................................................ 3 2. Introduction ............................................................................................................................................... 4 2.1. Scope of Tests .......................................................................................................................................... 4 2.2. Purpose ..................................................................................................................................................... 4 2.3. Identification of the EUT ............................................................................................................................ 4 3. Power Input ............................................................................................................................................... 5 4. Grounding ................................................................................................................................................. 5 5. Support Equipment ................................................................................................................................... 5 6. Interconnect Leads .................................................................................................................................... 5 7. Modifications Made to the EUT ................................................................................................................. 5 8. Modes of Operation ................................................................................................................................... 5 9. Test Specifications .................................................................................................................................... 5 10. Test Plan ................................................................................................................................................... 6 11. Deviation, Additions to, or Exclusions from Test Specifications ............................................................... 6 12. Laboratory Conditions ............................................................................................................................... 6 13. Summary ................................................................................................................................................... 6 14. Sample Calculations ................................................................................................................................. 7 15. Statement of Conformity ........................................................................................................................... 7 16. Certification ......................................…
Text truncated - open the document above for the full version.
Engineering Test Report No. 2202429-03 Page 83 of 102 Test Setup for Spurious Radiated Emissions, 30MHz – 1GHz – Antenna Polarization Horizontal Test Setup for Spurious Radiated Emissions, 30MHz – 1GHz – Antenna Polarization Vertical Engineering Test Report No. 2202429-03 Page 84 of 102 Test Setup for Spurious Radiated Emissions, Above 1GHz – Antenna Polarization Horizontal Test Setup for Spurious Radiated Emissions, Above 1GHz – Antenna Polarization Vertical Engineering Test Report No. 2202429-03 Page 85 of 102 Test Details Manufacturer Chamberlain Group, LLC. EUT Residential Jackshaft Opener Model No. RJOA MPP Serial No. Radiated Sample 2 Test Peak Measurements in the Restricted Bands Mode Transmit at 902.25MHz Date Tested December 2, 2022 through December 5, 2022 Notes Meter CBL Ant Pre Total Total Limit Freq. Ant Reading Fac Fac Amp dBuV/m uV/m uV/m Margin MHz Pol (dBuV) Ambient (dB) (dB/m) (dB) at 3m at 3 m at 3 m (dB) 2706.75 H 57.0 2.8 33.4 -40.2 53.0 448.0 5000.0 -21.0 2706.75 V 55.7 2.8 33.4 -40.2 51.7 385.7 5000.0 -22.3 3609.00 H 62.5 3.2 34.6 -39.5 60.8 1098.8 5000.0 -13.2 3609.00 V 59.4 3.2 34.6 -39.5 57.7 769.0 5000.0 -16.3 4511.25 H 51.7 3.6 35.9 -39.6 51.6 380.5 5000.0 -22.4 4511.25 V 51.2 3.6 35.9 -39.6 51.1 359.2 5000.0 -22.9 5413.50 H 53.9 3.9 36.6 -39.5 54.9 556.8 5000.0 -19.1 5413.50 V 53.1 3.9 36.6 -39.5 54.1 507.8 5000.0 -19.9 8120.25 H 48.8 Ambient 4.9 38.3 -39.6 52.4 417.6 5000.0 -21.6 8120.25 V 48.8 Ambient 4.9 38.3 -39.6 52.4 417.6 5000.0 -21.6 9022.50 H 47.8 Ambient 4.9 38.6 -39.4 52.0 396.3 5000.0 -22.0 9022.50 V 48.0 Ambient 4.9 38.6 -39.4 52.2 405.5 5000.0 -21.8 Engineering Test Report No. 2202429-03 Page 86 of 102 Test Details Manufacturer Chamberlain Group, LLC. EUT Residential Jackshaft Opener Model No. RJOA MPP Serial No. Radiated Sample 2 Test Average Measurements in the Restricted Bands Mode Transmit at 902.25MHz Date Tested December 2, 2022 through December 5, 2022 Notes Average Average Average Meter CBL Ant Pre Duty Total Total Limit Freq. Ant Reading Fac Fac Amp Cycle dBuV/m uV/m uV/m Margin MHz Pol (dBuV) Ambient (d…
Text truncated - open the document above for the full version.
300 Windsor Drive · Oak Brook, Illinois · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.25 MHz - 926.75 MHz | 33.10 mW |

iDock Link 2
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterSMART GARAGE VIDEO KEYPAD
Equipment Class
DTS - Digital Transmission System
Wireless Chime
Equipment Class
DTS - Digital Transmission SystemVEHICULAR GATE OPENER
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterHandheld Remote
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter