FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Chamberlain Group LLC, The/
  3. HBW0635

HBW0635Part 15 Spread Spectrum Transmitter Commercial Door Operator Radio

Chamberlain Group LLC, The
Part 15 Spread Spectrum Transmitter Commercial Door Operator Radio - FCC ID HBW0635 - Chamberlain Group LLC, The
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 31, 2023
Application Purpose
Original Equipment
Date of Application
Jul 30, 2023
Equipment Note
Part 15 Spread Spectrum Transmitter Commercial Door Operator Radio
Frequency Range
2412.00000000 - 2462.00000000
Company
Chamberlain Group LLC, The
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗
↗
↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Industrial DC Operators Models JDC, JHDC, and TDC DC Jackshaft, Hoist, and Trolley For Doors up to 700, 1200, and 2200 lbs NOT FOR RESIDENTIAL USE NOT FOR RESIDENTIAL USE • Please read this manual and the enclosed safety materials completely, prior to installation and use! • This product is to be installed and serviced by a trained door systems technician ONLY. • These operators are compatible with myQ®, myQ® Smart Facility Access™, and Security+ 2.0® accessories. • These operators are Wi-Fi® compatible. LiftMaster 300 Windsor Drive Oak Brook, IL 60523 2 YEAR WARRANTY Serial # Installation Date Scan here for LiftMaster support videos and content. 2 Table of Contents Safety Information 3 Safety Symbol and Signal Word Review..................3 Planning 4 Introduction 5 Voltage Selection .......................................5 Amperage ..............................................5 Operator Specifications 6 Operator Dimensions 7 Jackshaft (JDC) and Hoist (JHDC).......................7 TDC Trolley .............................................8 Battery Backup .........................................8 TDC Trolley Operators 9 Carton Inventory........................................9 Description .............................................9 Hardware ...............................................9 TDC Trolley Assembly 10 Assemble the Operator ...............................10 Install the Chain.......................................11 TDC Trolley Installation 12 Install the Header Bracket.............................12 Attach the Track to the Header Bracket and Hang the Operator..............................................13 Attach the Door Arm and Bracket .....................14 Jackshaft (JDC) and Hoist (JHDC) Operators 15 Carton Inventory......................................15 Description ...........................................15 Door Sprockets.......................................15 JDC/JHDC Assembly 16 Configure the Operator ...............................16 JDC/JHDC Installation 17 Determine Mounting Location.........................17 Mount the Operator...................................18 Secure the Chain Hoist................................18 Cable Tension Monitors 19 Install the Cable Tension Monitor(s) (Optional) .........19 Manual Release 20 Emergency Disconnect System Model TDC ...........20 Emergency Disconnect System Model JHDC..........20 Wiring 21 Power and Ground ....................................21 Voltage Selection .....................................21 Wall Controller Installation 22 Factory Wiring Diagram 23 Accessory Wiring Diagram 25 Power Wiring Diagram 26 Entrapment Protection 27 Monitored Entrapment Protection.....................27 Install the Monitored Light Curtain.....................28 Battery Backup Wiring 29 Testing 30 Test all Entrapment Protection Devices................30 Test Wall Controller Menu Access .....................30 Test Limit Adjustment .................................30 Programming 31 Quick Start Commissioning ...........................31 Manual Commissioning Program Flow.................31 Operating Modes .....................................34 Determine Operating Mode ...........................35 Determine and Set Operating Mode . . . . . . . . . . . . . . . . . . . 36 Programmable Inputs .................................44 Radio .................................................44 Programming Remote Controls and myQ® Devices ....44 Erasing Programmed Devices . . . . . . . . . . . . . . . . . . . . . . . . . 44 Reset Defaults ........................................44 myQ® Smart Facility Access...........................45 Setup a myQ® Smart Facility Access Account .........45 Provisioning Wi-Fi.....................................45 Auxiliary Relays Accessory Kit ([XXXXX]) 46 Configure the Relay Adapter ..........................46 Loop Detector Board 47 Troubleshooting 48 Maintenance 51 Maintenance Schedule................................51 Accessories 52 Field Installable Accessory Kits 55 Service Parts 56 Model TDC............................................56 Model JHDC ..........................................57 Model TDC, JDC, and JHDC Common Parts ...........57 Warranty 58 MYQ® CONNECTIVITY • myQ® Smart Facility Access Technology enables secure monitoring and control of door operators and other myQ® Smart Facility Access devices with a smartphone, tablet or computer. • Alerts can be received as email notifications, ensuring the status of a commercial door. SAFETY AND SECURITY Security+ 2.0® – with every press of the button, a new code is sent to the commercial door operator, ensuring a door will only open for the remote control programmed. UL 325 requires all commercial door operators to be either constant pressure to close or be equipped with a primary external monitored entrapment protection device. LiftMaster® is the leading brand of professionally installed commercial door operators and access control products for businesses worldwide. We are committed to quality products, innovative designs and comprehensive services which exceed our Customers’ expectations. 3 Safety Information Safety Symbol and Signal Word Review WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www. P65Warnings.ca.gov. WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. 2. Install door operator ONLY on properly balanced and lubricated door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH. 3. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing operator. 4. Disable ALL locks and remove ALL ropes connected to door BEFORE installing operator to avoid entanglement. 5. Install an operator, a minimum of 8 feet (2.44 …

Text truncated - open the document above for the full version.

Users Manual

18 JDC/JHDC Installation (continued) Mount the Operator The wall or mounting surface MUST provide adequate support for the operator. The surface must: • Be rigid to prevent play between the operator and the door shaft. • Provide a level base. • Permit the operator to be fastened securely and with the drive shaft parallel to the door shaft. 1. Mount the operator to the wall or mounting plate with the appropriate hardware (not supplied). 2. Place the door sprocket on the door shaft. 3. Wrap the drive chain around the door sprocket and the drive sprocket then secure with the master link. 4. Align the door and the drive sprockets. Insert keys and fasten the sprockets with the set screws (recommended torque for the set screws is 34-45 in/lb). NOTE: It is highly recommended to add a thread adhesive to secure the set screws in place. Secure the Chain Hoist 1. Fasten the door retaining bracket 4 feet (1.2 m) above the floor. NOTE: If the position of the operator causes the hand chain to hang in the door opening hook the chain to the side near the top of the door jamb. 1 2 3 Door retaining bracket Door retaining bracket 19 Cable Tension Monitors Install the Cable Tension Monitor(s) (Optional) TWO CABLE TENSION MONITORS MAY BE CONNECTED TO THIS OPERATOR. THE CABLE TENSION MONITORS DETECT ANY SLACK THAT MAY OCCUR IN THE CABLES AND WILL RESPOND ACCORDINGLY. NOTE: ONLY USE THE LIFTMASTER CABLE TENSION MONITORS, AS THEY HAVE BEEN TESTED AND APPROVED FOR THIS SYSTEM. See "Accessories" on page 52. 1. Make sure the door cable is approximately 1"-2" (25-50 mm) from the mounting surface. Door adjustments or shimming may be required to achieve proper depth for the door cable. The bracket must be flush with the mounting surface. 2. Position the cable tension monitor as close to the drum as possible. The optimal distance of the cable from the wall surface is no more than 2.5" (6.35 cm), and be sure the roller extends 1/8"-1/4" past the cable. Make sure the cable tension monitor and roller is free from any obstructions in all positions of operation. NOTE: There must be no obstructions in the installation area that prevent the cable tension monitor from closing completely when slack is detected. NOTE: Cable tension monitors must either be anchored to concrete, or a wood stud with appropriate fasteners. If neither are available, toggle bolt style drywall anchors with at least a 50 lbs rating are acceptable. 3. Run bell wire to the door operator junction box, and down to the control box through conduit as shown on the right. 4. Once the controller is installed, connect the bell wires parallel to the CTM and CMN terminals on the terminals on the controller (polarity is not important). See "Wall Controller Installation" on page 22 for installation information. Once installed, follow these steps to connect the wiring. 5. Connect the bell wires in parallel to the CTM and CMN terminals on the controller (polarity is not important). To simplify installation, the cable tension monitors can be wired together in the operator junction box, with only one pair of bell wires running down to the controller. 6. Repeat steps 1-5 for the opposite side of the door. Both cable tension monitors must be installed for proper operation. NOTE: Cable must have tension through entire door travel. Make sure there is no slack in cable on opposite side of door during normal operation. If slack occurs during door travel, adjust cables as required. Drum Cable Cable Tension Monitor Cable Tension Monitor Roller 1/4"-3/8" (6.4-95 mm) Cable Tension Monitors a e Drum Cable tension monitor Approx. 1-2" 25-60cm (when door is closed) OVERVIEW 21 22 23 24 SBC CMN CTM CMN CABLE TENSION MONITORS SBC Drum Cable Cable Tension Monitor Cable Tension Monitor Roller 1/4"-3/8" (6.4-95 mm) Cable Tension Monitors a e Drum Cable tension monitor Approx. 1-2" 25-60cm (when door is closed) OVERVIEW 21 22 23 24 SBC CMN CTM CMN CABLE TENSION MONITORS SBC Drum Cable Cable Tension Monitor Cable Tension Monitor Roller 1/4"-3/8" (6.4-95 mm) Cable Tension Monitors a e Drum Cable tension monitor Approx. 1-2" 25-60cm (when door is closed) OVERVIEW 21 22 23 24 SBC CMN CTM CMN CABLE TENSION MONITORS SBC 20 Manual Release Emergency Disconnect System Model TDC TO DISCONNECT DOOR FROM OPERATOR The door should be in the fully closed position if possible. 1. Pull emergency release handle straight down. Emergency disconnect will open. TO RECONNECT DOOR ARM TO TROLLEY 2. Lift free end of door arm to trolley. Pull emergency release handle to allow arm to engage roll pin. Release handle. Emergency disconnect will close. Emergency Disconnect System Model JHDC These operators have provisions for manually operating the door in case of emergency or power failure. These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. This operator includes Engage rope (green) and a disengage rope (red) with manual hoist to electrically disable the operator controls. 1. To disengage, pull the disconnect rope (red). 2. Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain. 3. Pull the engage rope (green) to operate the door again electrically. OPERATE A MANUAL HOIST 1. Pull down on the hoist engagement rope, engaging the hoist/interlock. NOTE: F96 SAFETY CIRC will be displayed. 2. Operate the door in the desired direction by pulling on one side or the other of the continuous loop chain. 3. To restore standard electrical operation to the operator, pull the hoist disengagement rope to disengage the hoist/interlock. WARNING To prevent possible SERIOUS INJURY or DEATH from a falling door or arm: • DISCONNECT electric power to the operator BEFORE manually operating your door. • DO NOT stand under the door arm when pulling the emergency release. • If possible, use emergency disconnect ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open doo…

Text truncated - open the document above for the full version.

Users Manual

54 Accessories (continued) MOUNTING BRACKETS CHAIN TENSIONERS (FOR JACKSHAFT TYPE OPERATORS) OPTION CARDS Pluggable Loop Detector Board (Accessory Kit: LPEXPKIT) Plug-in connector, LOOPDETLM, No wiring needed. 12VDC/3mA low power draw includes diagnostic and test feature, Prevents the door from closing on a vehicle in the path. Power efficient for maximum cycles on Battery Backup. Auxiliary Relay Board (Accessory Kit: HPAHAUX) Easy to install accessory board to use for Auxiliary Limit Switches, other auxiliary devices such as lights, bells, horn/strobes and other warning devices. ADDITIONAL CONTROL ACCESSORIES 86LM (15' [4.6 m])/86LMT (25' [7.6 m]) - Antenna Extension Kit The antenna extension kit can be used with EXT-ANT for maximum radio receiver range. RGL24LY - Red/Green Traffic Light TLS1CARD 50-HERK2 50450 02-103L RGL24LY 02-401M Indicates when a commercial door reaches the open position. Provides assurance of safe entering and exiting of the facility, reducing the potential for costly accidents. RGL-CTL - Red/Green Traffic Light-Compact Similar to RGL24LY function, but high- intensity LEDs and fully sealed enclosure. Ideal for single lane operations that require focused visibility. 50-HERK2 - Motion Detector 24V TLS1CARD 50-HERK2 50450 02-103L RGL24LY 02-401M Microwave motion detector with two independently programmable channels. 50450 - Switch Sectional Door Interlock TLS1CARD 50-HERK2 50450 02-103L RGL24LY 02-401M NEMA 4 switch disables operator control circuit when door is locked preventing electrical operation of the door. 55 Field Installable Accessory Kits DC45AH DC7AH DCWALLCTL - 6-Pack Ctn. XF208VDC - 208V Transformer Kit XF600VDC - 600V Transformer Kit AUXREL - Auxiliary Relay Board LPEXP - Loop Detector Board SLIDEKIT - Slide Door Accessory Kit DUALAUXTROLLEY - Dual Aux Trolley Kit BRAKEKITDCOPS - Brake Kit(s) HORIZMODDC - Horizontal Mount Accessory Kit CENTERMODDC - Center Mount Accessory Kit HANDCRANKDC - Hand Crank Accessory Kit DISCONNECTJDC - Disconnect for Jackshaft Operator Kit HTRCOMMDC - Heater Kit FOHMODDC - Front of Hood Mount CHAINTENSDC - Chain Tensioner HOISTMOUNTMODDC - GH to JHDC Mount Mode Plate Sprocket Kits See "Door Sprockets" on page 15 56 Service Parts Model TDC SERVICE KITS ItemPart #Description K41-0372-000Drive Sprocket 41 (1200/2200) K41-0373-000Drive Sprocket 48 (700) DOOR DRIVE CHAIN KITS ItemPart #DescriptionItemPart #Description 022-0033#48 Chain (1/3 & 1/2 HP) Doors 8' to 10' 1515-48B10G1Sprocket, 41B10x3/4" 022-0034#41 Chain (3/4 & 1 HP) Doors 8' to 10' 1619-41047Roller Chain, #41x47 Pitches 022-0035#48 Chain (1/3 & 1/2 HP) Doors to 12' 1719-48033MLimit Chain, #48x33 Pitches 022-0036#41 Chain (3/4 & 1 HP) Doors to 12'1875-10170Trolley 022-0037#48 Chain (1/3 & 1/2 HP) Doors to 14' 1975-10174Front Idler Assembly 022-0038#41 Chain (3/4 & 1 HP) Doors to 14'20K75-10259Tracker Spacer 022-0039#48 Chain (1/3 & 1/2 HP) Doors to 16' 2110-10205Header Bracket 022-0040#41 Chain (3/4 & 1 HP) Doors to 16'2211-10130Header Pivot Pin 022-0041#48 Chain (1/3 & 1/2 HP) Doors to 18' K5K75-12870Door Arm Kit Complete with: Curved Arm, Straight Arm, Door Bracket and Hardware. 022-0042#41 Chain (3/4 & 1 HP) Doors to 18'24Door Track* (Call for pricing and availability) 022-0043#48 Chain (1/3 & 1/2 HP) Doors to 20' 2510-10011M1Frame 022-0044#41 Chain (3/4 & 1 HP) Doors to 20'26K75-10030Frame Spacer 022-0455271110197Take Up Bolt 28K75-17034Heavy Duty Straight Arm K5 18 19 20 22 21 24 27 28 57 Service Parts Model JHDC SERVICE KITS ItemPart #Description 190925FT12Hoist Chain (verify part number 25' and 29') K41-0269-000Disengage Rope (red), Engage Rope (green), two screws 15-50B12LGHDrive Sprocket Model TDC, JDC, and JHDC Common Parts SERVICE KITS ItemPart #DescriptionItemPart #Description K41-0374-00024 DC Motor, Gear Box & Encoder (Jack Shaft 700) K41-0394-000EMI Board 2200 (480Vac) K41-0375-00024 DC Motor, Gear Box & Encoder (Jack Shaft 1200) K41-0395-000Control Box with Cover K41-0376-00024 DC Motor, Gear Box & Encoder (Jack Shaft 2200) K41-0380-000Bridge Rectifier 700/1200 K41-0377-00024 DC Motor, Gear Box & Encoder (Trolley 700) TBDBridge Rectifier 2200 K41-0378-00024 DC Motor, Gear Box & Encoder (Trolley 1200) K41-0381-000Toroidal Transformer 700Lb/120Vac-240VAC K41-0379-00024 DC Motor, Gear Box & Encoder (Trolley 2200) K41-0382-000Toroidal Transformer 700Lb/480VAC K41-0409-0001200 Extended duty Motor, Gear Box & Encoder Trolley K41-0383-000Toroidal Transformer 1200Lb/120Vac-240VAC K41-0410-0001200 Extended duty Motor, Gear Box & Encoder Hoist K41-0384-000Toroidal Transformer 1200Lb/480VAC K41-0388-000Main board (with Battery Backup)K41-0385-000Toroidal Transformer 2200Lb/120Vac-240VAC K41-0389-000EMI Board 700 (120VAC 240VAC)K41-0386-000Toroidal Transformer 2200Lb/480VAC K41-0390-000EMI Board 700 (480Vac)K77-36541Antenna K41-0391-000EMI Board 1200 (120VAC 240VAC) K41-0387-000Encoder (with drive sprocket, snap ring, mounting plate, screws) K41-0392-000EMI Board 1200 (480Vac)TBDBrake 24VDC (for 2200 operators) K41-0393-000EMI Board 2200 (120VAC 240VAC) 58 Warranty LIFTMASTER® LIMITED WARRANTY LiftMaster (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defects in materials and/or workmanship for a specific period of time as defined below (the “Warranty Period”). The warranty period commences from the date of purchase. WARRANTY PERIOD PartsMotor and ControllerAccessories 1 Year2 years1 year The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, and maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety. If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131, toll free, before dismantling this product. You will be advised of disassembly and shipping…

Text truncated - open the document above for the full version.

Users Manual

300 Windsor Dr. Oak Brook, IL 60523 chamberlaingroup.com 1 Industry Canada / ISED May 22, 2023 3701 Carling Ave., Bldg. 94, Ottawa, ON, K2H 8S2 FCC ID: HBW0635 and IC: 2666A-0635 Letter of Attestation to confirm French manual version To whom it may concern, Please use this letter as confirmation that prior to placing the products to the market and available for sale, the appropriate reference to the appropriate RSS standard will be completed and available in the French language also. It contains the RF exposure statements and appropriate references. Below is the exact wording that is placed in our instruction manuals. This has been previously approved by both the FCC and IC. I would appreciate your prompt attention to the submittal. If there are any questions, please call me at 630-516-6613. Sincerely, David Bornemann Staff Regulatory Engineer

Attestation Statements

TO: Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd Columbia, MD 21046 Regards, Signature: Thomas DeSilvia Date: February 10, 2023 Signed by: Thomas DeSilvia This Agreement is valid until rescinded by the Applicant FRN number: 0004301545 Email: [email protected] Telephone No: 1-630-993-8618 Oak Brook, IL. 60523 Address: 300 Windsor Drive Contact Name: Tom DeSilvia, Director Corporate Compliance The Chamberlain Group LLC (“the applicant”) consent to accept the service of process. An applicant located in the United States may designate itself as the agent f or service of process. agent f or service of process, regardless of whether the applicant is a domes tic or f oreign entity. applicant must designate a contact located in the United States f or purposes of acting as the applicant’s Certif ication designating a U.S. agent f or service of process. As required by section 2.911(d)(7), the Covered List. equipment and video surveillance equipment produced by entities identif ied on the Commission’s the Commission adopted rules that prohibit equipment authorization f or “covered” telecommunications equipment that poses an unacceptable risk to national security or the saf ety of U.S. person s. Specif ically, Commission adopted new FCC requirements to protect the nation’s networks and supply chains f rom Pursuant to FCC 22-84 Report and Order and KDB 986446 D01 Covered Equipment v01, the Date: February 10, 2023

Attestation Statements

TO: Elite Electronic Engineering 1516 Centre Cir Downers Grove, IL 60515 Date: July 11, 2023 Please let this letter of attestation serve to authorize David Bornemann, Staff Regulatory Engineer at Chamberlain, to sign off of the FCC Letter of Confidentiality, Agency Authorization Letter, the Certification Agreements, FCC Certification Cover Letter, Manual Warning Statement, FCC application. The Chamberlain Group LLC (“the applicant”) and myself, Tom DeSilvia, consent to this authorization. Contact Name: Tom DeSilvia, Director Regulatory Engineering Address: 300 Windsor Drive Oak Brook, IL. 60523 Telephone No: 1-630-993-8618 Email: [email protected] Regards, Signature: Thomas DeSilvia Date: July 11, 2023 Signed by: Thomas DeSilvia This Agreement is valid until rescinded by the Applicant

Attestation Statements

TO: Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd Columbia, MD 21046 Date: February 10, 2023 Thank you. Regards, Signature: Thomas DeSilvia Date: February 10, 2023 Signed by: Thomas DeSilvia is not identified on the covered list as an entity producing covered equipment. The Chamberlain Group LLC (“the applicant”) that as of the date of the filing of the application, the applicant authorization pursuant to section 2.903 of the FCC rules. sought is not “covered” equipment prohibited f rom receiving an equipment The Chamberlain Group LLC (“the applicant”) certif ies that the equipment f or which authorization is Certif ications concerning “covered” equipment. Section 2.911(d)(5)(i)-(ii). Covered List. equipment and video surveillance equipment produced by entities identif ied on the Commission’s the Commission adopted rules that prohibit equipment authorization f or “covered” telecommunications equipment that poses an unacceptable risk to national security or the saf et y of U.S. persons. Specif ically, Commission adopted new FCC requirements to protect the nation’s networks and supply chains f rom Pursuant to FCC 22-84 Report and Order and KDB 986446 D01 Covered Equipment v01, the

Cover Letter(s)

300 Windsor Dr. Oak Brook, IL 60523 chamberlaingroup.com 1 May 22, 2023 TO: Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd Columbia, MD 21046 ATTENTION: Federal Communication Commission Equipment Authorization To whom it may concern, We would like to submit for Certification to FCC: HBW0635. Please find in the following application all related documentation to support this New Single Certification. We would appreciate your prompt attention to the submittal. Applicant Company name: The Chamberlain Group, LLC Contact Name: David Bornemann Address: 300 Windsor Dr., Oak Brook, IL 60523 Telephone No: 630-516-6613 Fax No: 630-516-6813 Email: [email protected] FCC ID Number: HBW0635 Signature: Date: 05/22/2023 Signed by (printed name): David Bornemann

Cover Letter(s)

Date: May 22, 2023 Subject: Confidentiality Request for: HBW0635 and 2666A-0635 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 10, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit X Permanent Block Diagrams X Short Term External Photos Internal Photos Operation Description/Theory of Operation Parts List & Placement/BOM Tune-Up Procedure X Permanent X Permanent X Permanent X Permanent Schematics X Short Term Test Setup Photos User’s Manual *Note: The Chamberlain Group LLC has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ELITE ELECTRONIC ENGINEERING, INC. in the event information regarding the product or the product is made available to the public. ELITE ELECTRONIC ENGINEERING, INC. will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications: The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, By: David Bornemann Staff Regulatory Engineer X Short Term* X Short Term* *

ID Label/Location Info

300 Windsor Dr. Oak Brook, IL 60523 chamberlaingroup.com 1 FCC/IC Label Artwork

RF Exposure Info

Engineering Test Report No. 2301031-03 Report Date July 18, 2023 Manufacturer Name The Chamberlain Group, Inc. Manufacturer Address 300 Windsor Dr Oak Brook, IL 60523 Product Name Model No. Industrial DC Operator JHDC7S1BMC, JHDC7S4BMC, JHDC12S1BMC, JHDC12S4BMC Date Received June 1, 2023 Assessment Dates June 5 – July 11, 2023 Specifications FCC 47 CFR Part 1 §1.1310 & Part 2 §2.1091 and §2.1093 KDB 447498 D01 OET Bulletin 65:1997 RSS-102 Issue 5, Amend. 1 Test Facility Elite Electronic Engineering, Inc. 1516 Centre Circle, Downers Grove, IL 60515 FCC Reg. Number: 269750 IC Reg. Number: 2987A CAB Identifier: US0107 Signature Tested by Tylar Jozefczyk Signature Approved by Raymond J. Klouda, Registered Professional Engineer of Illinois – 44894 PO Number 4900090806 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. This report shall not be reproduced, except in full, without the written approval of Elite Electronic Engineering Inc. Engineering Test Report No. 2301031-03 This report shall not be reproduced, except in full, without the written approval of Elite Electronic Engineering Inc. Page 2 of 15 Table of Contents 1. Report Revision History ............................................................................................................................ 3 2. Introduction ............................................................................................................................................... 4 3. Subject of Investigation ............................................................................................................................. 4 4. Standards and Requirements ................................................................................................................... 4 5. Sample Calculations ................................................................................................................................. 5 6. Photographs of EUT .................................................................................................................................. 6 7. Limits and Requirements .......................................................................................................................... 8 7.1. Requirements mandated by the FCC ....................................................................................................... 8 7.2. Requirements mandated by Innovation, Science and Economic Development Canada ....................... 11 8. Assessment Results ................................................................................................................................ 13 8.1. RF Exposure Evaluation Relevant to the Requirements of the FCC ...................................................... 13 8.2. RF Exposure Evaluation Relevant to the Requirements of the ISED ..................................................... 14 8.2.1. Assessment Results for General/Uncontrolled Environments ............................................................ 14 9. Statement of Compliance ........................................................................................................................ 15 Engineering Test Report No. 2301031-03 Page 3 of 15 1 . R e p o r t R e v i s i o n H i s t o r y Revision Date Description – 19 JUL 2023 Initial Release of Engineering Test Report No. 2301031-03 Engineering Test Report No. 2301031-03 Page 4 of 15 2 . I n t r o d u c t i o n The FCC, Innovation, Sc…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Thomas DeSilvia(Director Corporate Compliance)
[email protected]630 993 8618Fax: 630 516 6871

Technical Contact

The Chamberlain Group, Inc.David Bornemann
[email protected]6305012269

300 Windsor Drive · Oak Brook · United States

Test Firm

Elite Electronic Engineering Inc.Kevin Halpin
[email protected]630-495-9770Fax: 630-495-9785

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz151.00 mW
Confidentiality
Long Term
Grant Notes
Power Output is conducted. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures and RF Exposure compliance.

Other Applications from Chamberlain Group LLC, The

iDock Link 2 - FCC ID HBW73514 - Chamberlain Group LLC, The
HBW73514

iDock Link 2

Jul 06, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
HBW-VKP2K

SMART GARAGE VIDEO KEYPAD

Jun 23, 2026

Equipment Class

DTS - Digital Transmission System
Wireless Chime - FCC ID HBWCHM1 - Chamberlain Group LLC, The
HBWCHM1

Wireless Chime

Dec 03, 2025

Equipment Class

DTS - Digital Transmission System
HBWN519

VEHICULAR GATE OPENER

Oct 10, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
HBWN329

Handheld Remote

Sep 22, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter