3-BUTTON REMOTE CONTROLS MODELS 890MAX, 893MAX, AND 895MAX To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door: β’ ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with remote controls. β’ Activate gate or door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel. β’ ALWAYS keep gate or garage door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door. LED LED Locate the Program button on the remote control. Locate the Learn button on the garage door opener. NOTE: Your garage door opener may look different. OROR Learn LED Learn LED Learn LED Green or Red/Orange Purple Yellow Program Button 2 3 Press and release the remote control button you want to use... 4 To exit programming mode, press any remote control button except the button that was just programmed. Install the visor clip (not applicable for Model 890MAX). 6 The garage door opener will activate. To test, press the programmed button on the remote control... 1 Press and release the Learn button on the garage door opener. Within 30 seconds... The Learn LED will light. Check to see if the garage door opener light bulb blinks. If not, wait for the remote control LED to light solid then slowly press and release the remote control button again. Repeat until the light bulb blinks. DO NOT press the button after the light bulb blinks. 5 To enter programming mode, press the Program button until the LED on the front of the remote control turns on. Safety Pin or Paper Clip Visor Clip MODEL 893MAX MODEL 890MAX PREPARE PROGRAMMING THE REMOTE CONTROL 893MAX 890MAX MODEL 895MAX 895MAX LEDs 890MAX 895MAX 893MAX Can be used as a replacement remote control for 80 Series, 970 Series, and 370 Series LiftMaster remote controls. Compatible with 315 MHz or 390 MHz garage door openers manufactured after January 1, 1993. Make sure the garage door opener has a working light bulb because it is a programming indicator. For use with gate operators, commercial door operators, or other products that are 315 MHz or 390 MHz and have a Learn button. Refer to your product manual for the location of the Learn button. NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards for Home or office use. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. BATTERY The LED(s) on your remote control will stop flashing when the battery is low and needs to be replaced. To replace battery, open the case as shown. Insert battery positive side up (+). Replace the battery with only 3V2032 or 3V2016 coin cell batteries (depending on the model). Dispose of old battery properly. To prevent possible SERIOUS INJURY or DEATH: β’ NEVER allow small children near batteries. β’ If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn: β’ Replace ONLY with 3V2032 coin batteries. β’ DO NOT recharge, disassemble, heat above 212Β° F (100Β° C) or incinerate. 1-800-528-9131 114A3930 Β© 2011, The Chamberlain Group, Inc. All Rights Reserved REPLACEMENT PARTS 3V2032 Lithium Battery (Models 893MAX & 890MAX) . . . . . . . . . . 10A20 3V2016 Lithium Battery (Model 895MAX) . . . . . . . . . . . . . . . . . . . . 10A19 Visor Clip (Model 893MAX) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29B137 Visor Clip (Model 895MAX) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29C151 1 2 3 WARRANTY www.liftmaster.com ONE YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the first consumer purchaser of this product that it is free from defect in materials and/or workmanship for a period of 1 year from the date of purchase. Pry open the case with a screwdriver blade. 890MAX Pry open the case fi rst in the middle (1), then at each side (2 and 3) with the visor clip. 893MAX Remove the two screws and open the case. 895MAX 3V2032 3V2016 Additional buttons on the remote control can be programmed to operate up to 3 devices such as additional garage door openers, light controls, gate operators or access control systems. Press and hold the button down until the door or gate starts to move. The remote control will operate from up to 3 car lengths away on typical installations. Installations and conditions vary, contact an installing dealer for more information. HOW TO USE THE REMOTE CONTROL
845 Larch Ave. Elmhurst, IL 60126 Phone 630.993.6306 Fax 630.516.6863 Email: [email protected] April 18, 2011 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, Maryland 21046 c.c. Underwriters Laboratories Inc. 333 Pfingsten Road Norhtbrook, IL 60062 To whom it may concern: I, the undersigned, hereby authorize Bart Mucha of Underwriters Laboratories Inc to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by Bart Mucha of UL on our behalf, shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing UL as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the productβs compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Yours sincerely, Barbara Kelkhoff Regulatory Project Manager II Chamberlain Group, Inc. 845 Larch Ave. Elmhurst, IL. 60126
845 Larch Ave. Elmhurst, IL 60126 Phone 630.993.6306 Fax 630.516.6863 Email: [email protected] March 29, 2011 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, Maryland 21046 FCC ID:HBW1D7510 Request for Confidentiality In accordance with 47 C.F.R. Section 0.457 and 0.459, we, Chamberlain Group, Inc., hereby request confidentiality for the block diagram, schematic and product description presented for certification. In support of the Request for Confidentiality, the following is stated: Enclosed within this application is technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to our disadvantage. To assist in assuring that we receive the full value of our product and protect its competitive posture, we respectfully request this grant of confidentiality. I would appreciate your prompt attention to the submittal. If there are any questions, please call me at 630-993-6306 or send a fax to 630-516- 6863. Sincerely, Barbara Kelkhoff Regulatory Project Manager II Chamberlain Group, Inc. 845 Larch Ave. Elmhurst, IL. 60126
Chamberlain Group Inc. FCC ID: HBW1D7510 β External Photos
Chamberlain Group Inc FCC ID: HBW1D7510 β Internal Photos
Underwriters Laboratories Inc. A not-for-profit organization dedicated 333 Pfingsten Rd. to public safety and committed to Northbrook, IL 60062 quality service for over 100 years Tel: (847) 272-8800 Underwriters Laboratories Inc. 333 Pfingsten Rd. Northbrook, IL 60062 www.ul.com/emc (847) 272-8800 Job Number: 1001339652 Project Number: 11CA06144 File Number: MC3181 Date: March 3, 2011 Model: 1D7510 Electromagnetic Compatibility Test Report For Chamberlain Group Inc. Copyright ο 2010 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Job #:1001339652 Project #: 11CA06144 File #: MC3181 Page 2 of 37 Model Number: 1D7510 FCC ID: HBW7510 Client Name: Chamberlain Group Inc. Underwriters Laboratories Inc. 333 Pfingsten Rd. Northbrook, IL 60062 USA Tel.: 847 272-8800 Rev. No 1.0 EMC Report 2010-87-EM-F0042 Test Report Details Tests Performed By: Underwriters Laboratories Inc. 333 Pfingsten Rd. Northbrook, IL 60062 Tests Performed For: Chamberlain Group Inc. 845 Larch Av Elmhurst, IL 60126 Applicant Contact: Hank Sieradzki Phone: (630) 993-6564 E-mail: [email protected] Test Report Date: March 3, 2011 Product Type: Periodic Transmitter Product standards FCC Part 15, Subpart C, 15.231 & RSS-210 Model Number: 1D7510 EUT Category: Periodic Low Power 3 channel Transmitter Testing Start Date: January 24, 2011 Date Testing Complete: February 25, 2011 Overall Results: Compliant Underwriters Laboratories Inc. reports apply only to the specific samples tested under stated test conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. Underwriters Laboratories Inc. shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Underwriters Laboratories Inc. issued reports. This report shall not be used to claim, constitute or imply product certification, approval, or endorsement by NVLAP, NIST, A2LA, or any agency of the US government. This report may contain test results that are not covered by the NVLAP or A2LA accreditation. The scope of accreditation is limited to the specific tests that are listed on the NVLAP and/or A2LA websites referenced at the end of this report. Job #:1001339652 Project #: 11CA06144 File #: MC3181 Page 3 of 37 Model Number: 1D7510 FCC ID: HBW7510 Client Name: Chamberlain Group Inc. Underwriters Laboratories Inc. 333 Pfingsten Rd. Northbrook, IL 60062 USA Tel.: 847 272-8800 Rev. No 1.0 EMC Report 2010-87-EM-F0042 Report Directory 1.0 G E N E R A L - Product Description ..................................................................................................................4 1.1 Equipment Description ...................................................................................................................................4 1.2 Device Configuration During Test ..................................................................................................................4 1.2.1 Equipment Used During Test: ....................................................................................................................4 1.2.2 Input/Output Ports: .....................................................................................................................................4 1.2.3 Power Interface: .........................................................................................................................................4 1.3 EUT Configurations ........................................................................................................................................5 1.4 EUT Operation Modes ....................................................................................................................................5 2.0 Summary ............................................................................................................................................................5 2.1 Deviations from standard test methods ..........................................................................................................5 2.2 Device Modifications Necessary for Compliance ...........................................................................................5 2.3 Reference Standards .....................................................................................................................................6 2.4 Results Summary ...........................................................................................................................................6 3.0 Calibration of Equipment Used for Measurement ..............................................................................................7 4.0 EMISSIONS TEST RESULTS ............................................................................................................................7 4.1 Test Conditions and Results β Occupied Bandwidth .....................................................................................8 4.2 Test Conditions and Results β Cease Operation ........................................................................................ 14 4.3 Test Conditions and Results β Pulse Train ................................................................................................. 17 4.4 Test Conditions and Results β RADIATED EMISSIONS Fundamental and Spurious ............................... 24 Appendix A - Accreditations and Authorizations .......................................................................................................... 35 Appendix B β Test Setup Photos .................................................................................................................................. 37 Job #:1001339652 Projectβ¦
Text truncated - open the document above for the full version.
333 Pfingsten Road Β· Northbrook Β· United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 390 MHz | - |

iDock Link 2
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterSMART GARAGE VIDEO KEYPAD
Equipment Class
DTS - Digital Transmission System
Wireless Chime
Equipment Class
DTS - Digital Transmission SystemVEHICULAR GATE OPENER
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterHandheld Remote
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter